AZM 161SK 12/12RKED/TU 024

Similar documents
Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Datasheet - MV8H Y

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety door-handle system STS

Technical data. Standards: IEC/EN BG-GS-ET-15

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Solenoid interlock AZM 200 The non-contact interlock.

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Door locking devices. 4 Schmersal Industrial Switchgear

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Safety switches with solenoid and separate actuator

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Safety switches with separate actuator

Operating instructions Solenoid interlock AZM 170

Safety switches with solenoid and separate actuator

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Safety Switches with Separate Actuator SKC

Safety switches with separate actuator

Operating instructions Solenoid interlock AZM About this document. Content

Guard locking systems for the protection of man and machine

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

LR-LX-LK-LW Safety Switches with separate actuator

Safety switches for hinges

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Safety switches / Position switches / Command devices

Safety Sensor CSS 180 Product Information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Safety switches for hinged doors

Safety rope switches with reset for emergency stop

Installation and Operating Instructions

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

MS General Information Extended Product Type: MS

Switches Unlimited Phone: * Fax:

FL series position switches

Position Switches Series 8070/2

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Installation and Operating Instructions

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Position Switches Series 8060/2

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Load disconnect switch Series 8146/5-V11

Page 2-4 Page 2-8. Page Page 2-13

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Position switches FD series

Safety rope switch without reset for simple stop

Position Switches Series 8074/2

Technical data for manual motor starters Type MS325

Safety Switches Series 8537

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

For Info: Phone: Fax:

Position switches FR series

SFS-UFS Single Foot Switches

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

Safety switches for hinged doors

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Control switch/load disconnect switch Series 8008

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Safety rope switch with reset for emergency stop

Under the aspect of simplified

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Thermal overload relay TF140DU and TF140DU-V1000

Safety Switches NP GP TP. More than safety.

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

HS1C Interlock Switches with Solenoid

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Thermal overload relay TF65 and TF96

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Operating instructions Solenoid interlock AZM About this document. Content

Safety switches with solenoid and separate actuator

Position switches FR series

Solenoid Locking Safety Switches

Switches with manual reset

Overloadrelay,10-16A,1N/O+1N/C. Articleno

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Hinged Safety Door Switch

AZM300 More than just a solenoid interlock

LK Position Switches TECHNICAL DATASHEET.

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

CI-TI Contactors and motor starters Types CI 61 - CI 98

Transcription:

10.06.2016 10:17:13h Datasheet AZM 161SK 12/12RKED/TU 024 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30 mm 6 Contacts Long life Large wiring compartment Manual release, cover side and Emergency exit, rear cable entries 4 M 16 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZM 161SK 12/12RKED/TU 024 Article number 101187866 EAN code 4030661357188 ecl@ss 27 27 26 03 Approval Approval BG USA/CAN CCC Classification Standards EN ISO 13849 1 B10d Opener (NC) 2.000.000 Mission time 20 Years notice Global Properties Product name AZM 161 Standards EN 60947 5 1, BG GS ET 19 Compliance with the Directives (Y/N) Number of actuating directions Yes 3 piece http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 1/8

Active principle electromechanical Duty cycle Magnet 100 % Materials Material of the housings Plastic, glass fibre reinforced thermoplastic, selfextinguishing Material of the contacts Silver Housing coating Weight None 500 g Mechanical data Actuating play in direction of actuation Design of electrical connection Cable section 5.5 mm Screw connection Min. Cable section 1 x 0,25 mm² Max. Cable section 1 x 1.5 mm² Mechanical life notice Emergency unlocking device (Y/N) Manual release (Y/N) Emergency release (Y/N) Latching force Positive break force positive break travel Clamping force F Max. Actuating speed Actuating frequency > 1.000.000 operations All indications about the cable section are including the conductor ferrules. Yes Yes No 30 N 20 N 10 mm 2000 N 2 m/s max. 1000 / h Ambient conditions Ambient temperature Min. environmental temperature 25 C Max. environmental temperature +60 C Protection class IP67 to IEC/EN 60529 Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Power to unlock Power to lock Rated control voltage Us Power consumption Rated impulse withstand voltage U imp Rated insulation voltage U i Thermal test current Ithe Normally open contact (NO), Opener (NC) Creep circuit element 2 piece 4 piece Yes No 24 VAC/DC max. 10 W 4 kv 250 V Utilisation category AC 15: 230 V / 4 A, DC 13: 24 V / 2,5 A Required rated short circuit current 6 A 1000 A Max. fuse rating 6 A gg D fuse To DIN EN 60269 1 ATEX Explosion protection categories for gases Explosion protected category for dusts None None Miscellaneous data http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 2/8

Applications sliding safety guard, removable guard, hinged safety guard Dimensions Dimensions of the sensor Width of sensor 130 mm Height of sensor 90 mm Length of sensor 30 mm notice Manual release For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Top side (ordering suffix ED) or rear side (ordering suffix EU) mounting possible Emergency exit The emergency exit is used where an intervention in an already locked hazardous area is required Emergency exit by pressing the red push button Resetting by pulling on the latched button Top side (ordering suffix TD) or rear side (ordering suffix TU) mounting possible A combination of manual release and emergency exit in different mounting directions in only possible for the following variants: ED/ TU and TD/ EU Diagram Note Diagram positive break NC contact active no active Normally open contact Normally closed contact Switch travel diagram http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 3/8

Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/ angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZM 161SK 12/12RKED/TU 024G...G Protected against incorrect polarity and voltage spikes. limited terminating space 0,75 mm² Diagram 14 guard open 13 +24 VDC 63 0 VDC 64 unlocked Ordering code AZM 161 (1) (2)(3)K(4) (5) (6)(7) (1) SK CC ST Screw connection Cage clamps male connector M12, 8 and 4 poles (Only for Us: 24 VAC/DC) (2) 12/12 2 Normally open contact (NO) / 4 Opener (NC) 12/11 2 Normally open contact (NO) / 3 Opener (NC) (Plug in connection) 11/12 2 Normally open contact (NO) / 3 Opener (NC) (Plug in connection) (3) without R Latching force 5 N Latching force 30 N http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 4/8

(4) without A Power to unlock Power to lock (5) without ED EU T TD TU N Manual release lateral Manual release cover side Manual release rear Emergency exit lateral Emergency exit cover side Emergency exit rear Emergency release (6) 024 Us: 24 VAC/DC 110/230 Us: 110/230 VAC (7) G with LED (Only for U s : 24 VAC/DC) Images Dimensional drawing (basic component) Operating principle http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 5/8

Operating principle System components Actuator 101145117 AZM 161 B1 101144416 AZM 161 B1E 101171859 AZM 161 B1ES 101175431 AZM 161 B1F 101171125 AZM 161 B1S 101173089 AZM 161 B1 2053 WITH BALL LATCH http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 6/8

101164100 AZM 161 B1 1747 WITH MAGNETIC LATCH 101178199 AZM 161 B1 2024 101176642 AZM 161 B1 2177 WITH CENTERING GUIDE 101174113 AZM 161 B6 2177 WITH CENTERING GUIDE For very smal actuating radii 101170375 AZM 161 B6S 101144420 AZM 161 B6 For very smal actuating radii Door handle system AZM 161 STS30 Latching handle Suitable for all types of guard Accessories 101100887 TRIANGULAR KEY TK M5 For manual release using M5 triangular key, available as accessory For maintenance, installation, etc. http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 7/8

101149213 Mounting set MS AZM 161 R/P 101150376 Mounting set MS AZM 161 P K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D 42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 10.06.2016 10:17:14h Kasbase 3.2.2.F.64I http://www.schmersal.net/datenblatt?lang=en&produkt=5je73339527dsoyaiye36563hw5rwm 8/8