LCU DX Efficient cooling with no loss of space

Similar documents
Blue e+ chillers with the principle

Outdoor system solutions

2 Rittal climate control/wall-mounted cooling units Blue e+

Compact Cooling Units

Outdoor system solutions

THE NEW TS IT RACK 8

Rittal TopTherm chiller

It s as simple as A,B,C...

More efficiency with the base/plinth system VX

TS IT Server/Network Enclosures

Baying systems TS 8. Height: 1200 mm/1400 mm, depth: 500 mm

The Rittal Flex-Block base/plinth system

Support arm system CP, with new height-adjustable support section

Rittal CS New Basic enclosure

Make IT easy: Enclosure, power and cooling solutions

Premium Quality - Value Price

Rittal console systems...

Rittal CM Compact System Enclosures

Our expertise your benefit. AE Available off the shelf.

TECHNICAL DATA MINICUBE A SMART SOLUTION, POWERFUL IN ITS SIMPLICITY

TS 8 Bayed Enclosure System

Technical System Catalogue Operating housings with handle strips

Plenty of space for intelligent solutions.

Catalog / 2016 North American Edition

SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT

TopTherm Filter Fans

VERAK S-MAX 19 standard cabinet for server

LED system light Sensationally bright

Catalog / 2016 North American Edition

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Cabinet-built single drives, ACS880-07

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

VTZ variable speed Reciprocating compressors

Technical System Catalogue Ri4Power

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Master MPS kva kva 3:1 3:3 VFI TYPE

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

19 floor rack with steel door

Railway technology solutions

ABB industrial drives ACS800, drive modules 0.55 to 2900 kw Catalog

The range is fully compatible with the PS system accessories.

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PQstorI One stop solution for energy storage and power quality

SCHÄFER IT-Systems The specialists for IT infrastructure

Electrical Control Valves

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Ri al The System. Faster be er everywhere.

ACCESSORIES FOR SZE2 CABINETS

Wall mounted cases W

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

ABB central inverters PVS to 1000 kw

High performance Vector Control. Ratings. System configuration

Product Data For FARNELL

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

SCHÄFER IT-Systems The specialists for IT infrastructure

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

TS 8 Specification Guide

Cabinets Outdoor. Optimal protection from vandalism thanks to a fixing accessible only from within. Easily exchangeable exterior cladding components.

Installation and Operating Instructions

TRIXCUBE TURNKEY SOLUTION

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

Planned Preventative Maintenance Schedule. Chilled Water Systems PPM Schedule. Data Centre Solutions Expertly Engineered

Emergency lighting units EM LED Light Engines

Models: 12 and 18. Models: 24 to 60

DIGITUS Network- and Server Cabinet Dynamic Basic Series

Master MPS kva kva 3:1 3:3 VFI TYPE

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

ABB central inverters PVS to 1000 kw

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

DIGITUS Network & Server Cabinets DYNAMIC BASIC Series

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Standby Amper VOLTAGE

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

2 The Isle of Cold Server enclosures. outdoor enclosure

NCF 60 Hz. Protection class IP 55

TE 7000, Top Efficiency: the Global IT Rack. Uncompromisingly geared to the network task

for STANDARD, HYBRID and ELECTRIC VEHICLES with R134a refrigerant For the brands OPEL CHEVROLET (Europe) VAUXHALL KONFORT 760R

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Fan coil unit NBS 100/150

HiLTO EC High efficiency heat recovery unit

483 mm (19 ) Server Cabinet Unique Series. Abstract. Features. 1.5 mm strong steel sheet. Load capacity up to 1000 kg. Standard colors grey and black

Transcription:

LCU DX Efficient cooling with no loss of space

2

Cooling for network and server enclosures Space-saving installation of the internal unit between the 482.6 mm (19 ) level and side panel Optimum support of IT-compatible, front-to-back air routing High level of fail-safeness guaranteed by availability of single and redundant variant Cooling of TS IT racks and Micro Data Center Refrigerant-based split cooling unit comprised of an internal unit (evaporator coil) and an external unit with integral compressor (inverter-controlled) External unit is sited outside the building 3

4

Benefits at a glance Maximum energy efficiency by cooling the individual rack, rather than the whole room Efficient operation thanks to EC fan technology Optimum adaptation of the compressor output to the current heat load of the IT rack with inverter control Ultimate security with optional alarm forwarding via CMC III High availability designed for continuous, 24/7 operation Absorbed thermal energy is emitted via the external unit directly to the ambient air The internal and external unit are connected with refrigerant, data and supply lines Control of the server inlet temperature 5

Network/server enclosures TS IT Cat. 34, page 90 Micro Data Center Cat. 34, page 466 Applications: Cooling unit for TS IT server enclosures and for Micro Data Center Benefits: Space-saving solution by installing the internal unit in the TS IT server enclosure or the Micro Data Center Maximum energy efficiency due to EC fan technology and ITbased control Control of the server inlet temperature The inverter-controlled compressor adapts the cooling output to the current heat loss inside the enclosure Absorbed thermal energy is emitted directly to the ambient air at the (inverter-controlled) external unit's location, without heating up the installation room Functions: The device supports "front to back" air routing typical of IT applications, and regulates the server inlet temperature to the set value Colour: Internal unit: RAL 7035 External unit: white Protection category IP to IEC 60 529: Internal unit IP 20 External unit IP X4 Supply includes: Internal unit (evaporator coil) External unit (inverter-controlled) 482.6 mm (19") mounting trim panel with display and control components Condensate hose Note: Below the operating limit, fluctuations in the air inlet temperature are possible The electrical connection is made on the external unit; the internal unit is supplied by the external unit Installation in TS IT: 482.6 mm (19") levels must be designed as mounting angles and offset in the width by 50 mm off-centre The front distance between the 482.6 mm (19") mounting angles and the front edge of the TS frame must be at least 100 mm Not suitable for combination with 482.6 mm (19") mounting frame Two punched sections with mounting flanges are required for attachment on the inner mounting level To separate the hot/cold zones within an enclosure, an air baffle plate for TS IT is required A Flex-Block base/plinth is required to route the cable downwards Further technical information: Available on the Internet 4 2 3 5 Internal unit External unit Refrigerant lines Power supply Data cable 1 6

LCU DX, single Design Packs of LCU DX 3 kw LCU DX 6.5 kw Page Model No. 1 pc(s). 3311.490 3311.492 For enclosure width mm 800 800 For enclosure height mm 1800 1800 For enclosure depth mm 1000 1000 External unit, W x H x D mm 810 x 558 x 310 845 x 700 x 320 Internal unit, W x H x D mm 105 x 1550 x 820 105 x 1550 x 820 Type of electrical connection Connection clamp Connection clamp Rated operating voltage V, ~, Hz 230, 1~, 50 230, 1~, 50 Rated current (max.) A 7 15.9 Pre-fuse A 16 20 Duty cycle % 100 100 Useful cooling output L22 L35 kw 3 6.5 Cooling medium R410a R410a Sound pressure level at a distance of 10 m (external unit) db(a) 40 40 Operating temperature range (external unit) -20 C...+45 C -20 C...+45 C Weight as delivered kg 116.0 126.0 Accessories Refrigerant lines 1 pc(s). 3311.495 3311.496 10 Any questions about our services or maintenance agreements? Rittal Service Do you need an individual, personal consultation or a service quote? Our service specialists will be happy to assist you. Manufacturers warranty Configuration and assembly Inspection Climate control pipework Commissioning Leak test Modernisation Maintenance Service agreements (SLA) Spare parts Response time Wearing parts Please direct enquiries to the local Rittal Service organisation, either by e-mail or phone. www.rittal.com/contact CMC III Processing Unit/Compact CMC III www.rittal.com/r?lcu-cmc3-en 7

Network/server enclosures TS IT Cat. 34, page 90 Micro Data Center Cat. 34, page 466 Applications: Cooling unit for TS IT server enclosures and for Micro Data Center in a redundant design Benefits: Space-saving solution by installing the redundantly designed internal unit in the TS IT server enclosure or the Micro Data Center Maximum energy efficiency due to EC fan technology and ITbased control Control of the server inlet temperature The inverter-controlled compressor adapts the cooling output to the current heat loss inside the enclosure Absorbed thermal energy is emitted directly to the ambient air at the (inverter-controlled) external unit's location, without heating up the installation room Functions: The redundant variants have two cooling circuits and controllers inside the internal unit, plus two inverter-regulated external units. The fault and operating hours changeover allows regular switching between the two external units, and ensures automatic changeover in the event of a malfunction or failure. The device supports "front to back" air routing typical of IT applications, and regulates the server inlet temperature to the set value Protection category IP to IEC 60 529: Internal unit IP 20 External unit IP X4 Supply includes: Internal unit (evaporator coil) 2 external units (inverter-controlled) 482.6 mm (19") mounting trim panel with display and control components Condensate hose Note: Below the operating limit, fluctuations in the air inlet temperature are possible The electrical connection is made on the external unit; the internal unit is supplied by the external unit A separate power supply may be needed, depending on the external unit Installation in TS IT: 482.6 mm (19") levels must be designed as mounting angles and offset in the width by 50 mm off-centre The front distance between the 482.6 mm (19") mounting angles and the front edge of the TS frame must be at least 100 mm Not suitable for combination with 482.6 mm (19") mounting frame Two punched sections with mounting flanges are required for attachment on the inner mounting level To separate the hot/cold zones within an enclosure, an air baffle plate for TS IT is required A Flex-Block base/plinth is required to route the cable downwards Further technical information: Available on the Internet 4 2 5 3 Internal unit External unit Refrigerant lines Power supply Data cable 1 2 8

LCU DX, redundant Design Packs of LCU DX 3 kw redundant LCU DX 6.5 kw redundant Page Model No. 1 pc(s). 3311.491 3311.493 For enclosure width mm 800 800 For enclosure height mm 1800 1800 For enclosure depth mm 1000 1000 External unit, W x H x D mm 810 x 558 x 310 845 x 700 x 320 Internal unit, W x H x D mm 105 x 1550 x 820 105 x 1550 x 820 Type of electrical connection Connection clamp Connection clamp Rated operating voltage V, ~, Hz 230, 1~, 50 230, 1~, 50 Rated current (max.) A 7 15.9 Pre-fuse A 16 20 Duty cycle % 100 100 Useful cooling output L22 L35 kw 3 6.5 Cooling medium R410a R410a Sound pressure level at a distance of 10 m (external unit) db(a) 40 40 Operating temperature range (external unit) -20 C...+45 C -20 C...+45 C Weight as delivered kg 154.0 174.0 Accessories Refrigerant lines 1 pc(s). 3311.495 3311.496 10 Rittal data centre health check know what s going on! Rittal Service On request, as part of a maintenance order Perform an evaluation or service agreement, we will carry out the Assess the risk following health check on your data centre, Highlight potential savings free of charge: Offer solutions Please direct enquiries to the local Rittal Service organisation, either by e-mail or phone. www.rittal.com/contact Power Distribution Unit PDU Power Distribution Unit www.rittal.com/r?lcu-pdu-en 9

Accessories/CMC III Refrigerant lines for LCU DX For connecting the internal and external unit of the LCU DX. Consisting of intake gas line and liquid line. The refrigerant lines are insulated. Further technical information: Available on the Internet Length m 20 20 Design LCU DX 3 kw LCU DX 6.5 kw Product-specific scope of supply Intake gas line ½ Liquid line ¼ Intake gas line ⅝ Liquid line ⅜ Packs of 1 pc(s). 1 pc(s). Model No. 3311.495 3311.496 CMC III Processing Unit Compact Computer Multi Control (CMC) is an alarm system for network and server enclosures, standard enclosures, containers and rooms. It monitors temperatures, humidity, access, smoke, energy and many other physical ambient parameters The system is modular in nature and can be flexibly adapted to meet specific monitoring requirements User benefits plus exceptional savings are achieved thanks to monitoring via the network and the automation of security processes Redundant voltage supply, plus Power over Ethernet (PoE) Simple wiring with CAN bus connection system (RJ 45) Connection to control desk systems via OPC UA and Modbus/TCP More information can be found on the Rittal website. Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 7035 Protection category IP to IEC 60 529: IP 30 Supply includes: Basic system Quick-start instructions 4 mounting feet Approvals: culus W x H x D mm 138 x 40 (1 U) x 120 + 12 (front assembly) Operating temperature range 0 C +45 C Operating humidity range 5 95% relative humidity, non-condensing Sensors/CAN bus connection units max. 4 Max. overall cable length for CAN bus 1 x 50 m Model No. 7030.010 CMC III accessories Model No. 7030.060 Power pack 100 240 V AC to 24 V DC 7200.215 Connection cable C13/C14 7030.070 Mounting unit, 1 U 7030.080 Programming cable USB 7030.090 CAN bus connection cable 0.5 m 7030.091 CAN bus connection cable 1 m 7030.111 Temperature/humidity sensor Further accessories can be found in Catalogue 34, from page 446 10

Configuration table Possible TS IT/LCU DX combinations The following TS IT variants from the modular TS IT system are available for installing the LCU DX internal unit in the TS IT: 482.6 mm (19 ) interior installation 482.6 mm (19 ) mounting angles Without interior installation, protection category IP 55 Front door Glazed door Glazed door Rear door Two-part, solid Onepiece, solid Roof With cable entry Solid Base Open Solid Width mm Height mm Depth mm Packs of Packs required Model No. 800 2000 1000 1 pc(s). 1 5509.120 800 2000 1200 1 pc(s). 1 5511.120 800 2200 1000 1 pc(s). 1 5514.120 800 2200 1200 1 pc(s). 1 5516.120 800 2000 1200 1 pc(s). 1 5511.790 800 2000 1000 1 pc(s). 1 5509.790 800 2200 1000 1 pc(s). 1 5514.790 800 2200 1200 1 pc(s). 1 5516.790 Also required Flex-Block trim panels, solid, W x H/D: 100 x 1000 mm 1 pc(s). 1 8100.010 Flex-Block trim panels, solid, W x H/D: 100 x 800 mm 1 pc(s). 1 8100.800 Flex-Block corner pieces, 100 mm 4 pc(s). 1 8100.000 Flex-Block trim panels, solid, W x H/D: 200 x 1000 mm 1 pc(s). 1 8200.010 Flex-Block trim panels, solid, W x H/D: 200 x 800 mm 1 pc(s). 1 8200.800 Flex-Block corner pieces, 200 mm 4 pc(s). 1 8200.000 Air baffle plate for TS IT, W x H: 800 x 2000 mm 1 pc(s). 1 5501.815 Air baffle plate for TS IT, W x H: 800 x 2200 mm 1 pc(s). 1 5501.835 TS punched section with mounting flange for depth 1000 mm 4 pc(s). 1 8612.500 TS punched section with mounting flange for depth 1200 mm 4 pc(s). 1 8612.520 Also required for TS IT 55xx.120 Gland plate, multi-piece, for depth 1000 mm Base mount for TS IT 2 pc(s). 1 5501.320 Gland plate, solid, with sliding panel, multi-piece 1 pc(s). 1 5502.550 Section for cable entry, centre 2 pc(s). 1 8802.080 Gland plate, multi-piece, for depth 1200 mm Base mount for TS IT 2 pc(s). 1 5501.350 Gland plate, solid, with sliding panel, multi-piece 1 pc(s). 1 5502.570 Section for cable entry, centre 2 pc(s). 1 8802.080 Note: Please follow the additional installation instructions on pages 8 and 10. 11

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can find the contact details of all Rittal companies throughout the world here. XWW00067EN1601 www.rittal.com/contact