New VikingTM 3, the innovation

Similar documents

New VikingTM3, the innovation Screw or automatic spring connection

Viking 3 - Screw connection Disconnect terminal blocks

Niloé. Just right for your projects

8WH2 Spring-Loaded Terminals

8WH6 ipo Plug-In Terminals

8WH2 Spring-Loaded Terminals

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

XL Distribution enclosures WORKSHOP SPECIFICATIONS

New DX 3 High rating & breaking capacity

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

Practical and completely safe

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

DX³ RCCBs - ID 4P up to 100 A

Single terminal blocks

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

Unimate Range Pitch 5.08

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

TX³ RCCBs 2P up to 100 A

CAB 3 TM marking and isolating sleeves

DPX moulded case circuit breakers

Domae. The right solution for distribution boards

Phase + Neutral, neutral on left side

Starfix TM ferrules and crimping tools

(1,5 modules per pole)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Synergy WIRING ACCESSORIES / PRODUCT GUIDE

Phase + Neutral, neutral on right side

2.7. IT system floor-standing distribution cabinet Series -IPS-F

DX³ 4-pole RCBO 6000 A/10 ka

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

Data sheet... W-Series WPE 4

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

Power distribution components

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

Datasheet. W-series terminal with clamping yoke connection WDU 2.5 RT

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

8WH6 ipo Installation Terminals

10 Load and Motor Switchgear

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Data sheet... W terminal earth terminal WPE 4

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

ZS4-SF1 Screw Clamp Terminal Block

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

COMPLETE SOLUTIONS FOR POWER PROTECTION

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Vistop TM isolating switches 63 to 160A

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Standard terminal blocks

Datasheet. W-series terminal with clamping yoke connection WDU 4

Manual Motor Starters. Meta-MEC

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

PANEL PANEL MOUNTING COMPONENTS

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Boxes and Socket-outlets for tunnel applications

USA Canada On the Internet: Toll Free wieland Product Range Electrical Connections

up to 63 A (1 module per pole)

Data sheet. W-Series WDU 4 SL/EN

P17 Tempra. and Hypra. Plugs and. Sockets PRODUCTS AND SYSTEMS FOR ELECTRICAL INSTALLATIONS AND INFORMATION NETWORKS. P17 Tempra. plugs and.

DBL distribution blocks 3x1 pole

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

- 1 - General ordering data Order No

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

AF40... AF96 3-pole contactors Technical data

NEW. Datasheet. WMF 2.5 Terminal Series

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Kaptika TM Focused on the essentials DURABILITY

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Powermate Range pitch 7.00 Powermate Range pitch 7.00

30Compact 200 A / 360 A

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

Safety switches with solenoid and separate actuator

Electronic Circuit Breaker ESS20-0..

INNOVATION IS OUR POWER.

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

ZS4-PE Screw Clamp Terminal Blocks Ground

Load and Motor Switches, Load-Break Switches Series 8549

BETA Switching Switches and Light Indicators

Transcription:

New VikingTM 3, the innovation Screw or automatic spring connection A new range, born of research & EXPERIENCE

INDEX Screw connection... 2 Automatic spring connection... 4 Common accessories... 6 Selection table... 8 Terminal blocks with screw connection and accessories Terminal blocks with spring connection and accessories 8 10 Characteristic and dimension... 12 Terminal blocks with screw connection... 12 Terminal blocks with spring connection... 14 Accessories for terminal blocks... 15

For over 30 years, Legrand has produced Viking 3 screw terminal blocks in its Normandy factories for the whole world. Millions of wiring installers have used the different generations. They are constantly providing ideas for improvement which today make them a benchmark in the connection field. Viking 3 terminal blocks are the core of a reliable and easy to use connection system, toghether with CAB 3 marking system and Starfix ferrules and crimping tools. Viking 3 terminal blocks and their CAB 3 marking system 1

NEW VIKING TM 3, THE INNOVATION Strength and security: High contact pressure using the clamp/bar system Captive screw Excellent mechanical strength with a specially selected clamp made of surfacetreated steel (1) Clamping tried and tested for strength, pulling-out, destructive torque resistance and ageing Perfect electrical conduction with the tinned brass bar (1) Permissible cross-sections: 0.25 mm 2 to 70 mm 2 (flexible wire) and 0.25 mm 2 to 95 mm 2 (rigid wire) (1) Complies with RoHS (Restriction of Hazardous Substances) requirements International approvals: UL/CSA/NF/VDE/IMQ/BV ATEX certification Conforms to IEC EN 60947-7-1, IEC EN 60947-7-2 and IEC EN 60947-7-3 2

screw connexion The other innovations Optimized size, simplified fixing and standardized end caps systems bring comfort of use for the new Viking 3 range and make installation, connection and marking easier than ever. Identical height for blocks of 16 mm 2 to 70 mm 2 Direct screwless fixing on rail for protection conductor modules (for pitches of 5 to 10) Single end caps for pitches of 5 to 10 3

NEW VIKING TM 3, THE INNOVATION Reliability and time saving: No tool required for connection: Direct insertion (1) up to pitch of 6. Disconnection with screwdriver With or without ferrule Constant contact pressure Double central marking area Better management of wires with the inclined cable entries Permissible cross-sections: 0. 5 mm 2 to 16 mm 2 (1) For a flexible wire with no ferrule, the spring is opened using a screwdriver International approvals: UL/CSA/NF/VDE/IMQ/BV ATEX certification Conforms to IEC EN 60947-7-1, IEC EN 60947-7-2 and IEC EN 60947-7-3 4

automatic spring connection The other innovations Actively listening to installers has resulted in Legrand's Research & Development department creating an innovative new Viking 3 spring terminal block which, over and above connection quality, has many advantages. Integrated end caps for pitches of 6 to 12 Pitch of 5 Pitch of 6 Bridging combs and markings are perfectly visible Optimized terminal block size. Identical electrical characteristics for blocks with a pitch of 5 and those with a pitch of 6 (one block gained every 5 blocks with a pitch of 5) 5

NEW VIKING TM 3 Screw or automatic spring: more convenient wiring and easier use End stop: screwless fixing Automatic-insertion bridging comb up to pitch of 8, 2 areas allowing pitch jumps Blown fuse indicator can be added at the last moment (12/48 V or 110/250 V) 6

thanks to common accessories. Managing cable shielding with dedicated accessories Addition of functions on module for equipping: standard, neutral or protected isolation, mini-circuit-breaker, automotive-type fuse, etc. Possibility of either manual marking (CAB 3) and computerized (Logicab 2) 7

Viking TM 3 terminal blocks with screw connection and accessories for copper cable ELECTRICAL FUNCTION 0 371 61 0 371 63 0 371 64 1 connection - 1 entries/1 outlet 0 371 66 0 371 69 0 371 68 Connecting 0 371 00 0 371 08 0 371 20 1 connection - 2 entries/2 outlets 2 connections on 2 levels 0 371 30 0 371 78 0 371 98 3 connections on 3 levels 0 371 71 0 371 76 0 371 79 For protection conductor 1 connection - 1 entry/1 outlet - metal base 1 connection - 2 entries/2 outlets - metal base Open (to be equipped) For fuse cartridge 5 x 20 with handle lever For fuse cartridge 5 x 20 with handle lever + blown fuse indicator 0 371 80 0 371 86 0 371 53 0 371 81 0 371 87 0 371 56 0 371 84 Disconnect Function blocks For sensor and actuator PNE 1 connection 1 connection 2 connections on 2 levels 3 connections on 3 levels For neutral circuit with handle lever With handle lever For standard circuit With mini lever For circuit not With handle lever broken With mini lever For fuse cartridge 5 x 20 with screwed plug Modular Diode carrier 1N4007 Diode carrier 1N4007 With voltage presence LED Sensor Actuator Phase/Neutral/Earth N 0 371 51 0 371 52 0 371 92 Measurement 1 connection Disconnect for measuring circuit 1: Blown fuse indicator 12/24/48 V = /A Cat.No 0 375 24 or 110/250 VA Cat.No 0 375 25-2: Or end stop Cat.No 0 375 10-3: Upper level only - 4: Lower level only - 5: Lower and intermediate levels 8

TERMINAL BLOCKS INSULATION EQUIPOTENTIAL LINK PROTECTION MEASURE- ASSOCIATED MENT PRODUCTS Nominal Pitch cross-section (mm) (mm 2 ) Colour End cap Separation and insulation divider Automatic insertion birdging comb 2 red blocks 10 red blocks 10 blue blocks Comb for 12 blocks, side Bar for 12 blocks, front Single pole screen Cut to length screen Test socket 0 371 60 0 371 00 2.5 5 0 375 50 0 371 20 (2) 0 375 60 0 375 02 0 375 01 0 375 00 0 375 65 0 375 68 0 375 27 (7) 0 371 30 0 371 61 0 371 01 4 6 0 371 21 0 375 50 (2) 0 375 60 0 375 05 0 375 04 0 375 03 0 375 65 0 375 68 0 375 27 (7) 0 371 31 0 371 77 0 371 62 6 8 0 375 07 0 371 02 0 375 50 (2) 0 375 60 0 375 08 (6) 0 371 78 0 375 66 0 375 68 0 375 27 0 371 63 10 10 0 375 50 (2) 0 371 03 0 375 60 0 375 40 0 375 66 0 375 68 0 375 75 0 371 64 16 12 0 371 04 0 375 51 0 375 61 0 375 42 0 375 67 0 375 69 0 375 76 0 371 98 35 15 0 371 65 0 371 05 0 375 51 0 375 61 0 375 44 0 375 67 0 375 69 0 375 76 0 371 99 70 22 0 371 66 built-in 0 371 69 4 6 0 375 52 0 371 09 0 375 62 0 375 05 0 375 04 0 375 03 0 375 27 (7) 0 371 67 2.5 5 0 375 53 0 371 07 0 375 63 0 375 02 0 375 01 0 375 00 0 375 27 (3)(7) 0 371 68 4 6 0 375 53 0 371 08 0 375 63 0 375 05 0 375 04 0 375 03 0 375 27 (3)(7) 2.5 5 0 371 51 0 375 54 0 375 54 0 375 02 (3) 0 375 01 (3) 0 375 00 (3) 0 375 46 (5) 0 375 47 (5) 2.5 5 0 371 70 4 6 0 371 71 0 375 50 (2) 6 8 0 371 72 10 10 0 371 73 0 375 27 (3)(7) End stops Label holder for end stop Handle lever mini lever Joining rods for disconnect blocks 16 12 0 371 74 0 375 51 35 15 0 371 75 35 15 0 371 76 4 6 0 371 79 0 375 52 Blown fuse indicators 2.5 6 0 371 80 0 375 55 0 375 62 0 375 05 0 375 04 0 375 03 0 375 27 (7) 0 371 81 0 371 81 + 0 375 24/25 (1) 0 371 82 0 371 83 0 375 55 0 375 62 0 375 05 0 375 04 0 375 03 0 371 84 0 375 55 0 375 62 0 375 05 0 375 04 0 375 03 0 375 27 (7) 0 371 85 0 375 55 0 375 62 0 375 05 0 375 04 0 375 03 0 371 86 0 375 55 0 375 62 0 375 05 0 375 04 0 375 03 0 375 27 (7) 10 12 0 371 87 0 375 56 Shielding CAB 3 2.5 5 4 6 0 371 53 0 375 55 0 375 02 0 375 01 0 375 00 0 375 27 (7) 0 371 54 0 371 55 0 375 53 0 375 63 0 375 05 0 375 04 0 375 03 0 375 27 (3)(7) 0 371 56 0 375 53 0 375 63 0 375 05 0 375 04 0 375 03 0 371 51 2.5 5 0 371 52 0 375 54 0 375 54 0 375 02 (3) 0 375 01 (3) 0 375 00 (3) 0 375 46 (5) 0 375 47 (5) 0 375 27 (3)(7) Logicab 2 4 8 0 371 92 0 375 57 0 375 77 6: Cat.No 0 375 07 for 3 terminal blocks - 7: Permanent measurement: side by side installation of 2 test sockets not possible Red catalogue numbers: New products 9

Viking TM 3 terminal blocks with spring connection and accessories for copper cable ELECTRICAL FUNCTION 0 372 60 0 372 61 1 connection - 2 wires - 1 entry/1 outlet 0 372 64 0 372 40 Connecting 0 372 69 0 372 68 1 connection - 3 wires - 1 entry/2 outlets 0 372 02 0 372 47 1 connection - 4 wires - 2 entries/2 outlets 0 372 21 0 372 42 2 connections - 4 wires - 2 levels 0 372 70 0 372 71 For protection conductor 1 connection - 2 wires - 1 entry/1 outlet - metal base 1 connection - 3 wires - 1 entry/2 outlets - metal base 0 372 72 0 372 12 1 connection - 4 wires - 2 entries/2 outlets - metal base Open (to be equipped) For fuse cartridge 5 x 20 with handle lever 0 372 80 0 372 82 Disconnect 1 connection 2 wires For fuse cartridge 5 x 20 with handle lever + blown fuse indicator For neutral circuit with handle lever For standard circuit With handle lever With mini lever N 0 372 83 0 372 84 0 372 54 0 372 56 Function blocks 1 connection 4 wires 2 entries/2 outlets 2 connections 4 wires 2 levels For circuit not broken Diode carrier 1N4007 Diode carrier 1N4007 With handle lever With mini lever With voltage presence LED 1: Blown fuse indicator 12/24/48V= /A Cat.No 0 375 24 or 110/250VA Cat.No 0 375 25-2: Lower level only - 3: Upper level only - 4: Current IEC 60947-7-1 : max. 24 A 5: Cat.No 0 375 07 for 3 terminal blocks - 6: Permanent measurement: side by side installation of 2 test sockets not possible 10

Nominal cross-section (mm 2 ) TERMINAL BLOCKS INSULATION EQUIPOTENTIAL LINK MEASUREMENT Pitch (mm) 4 5 4 6 6 8 10 10 16 12 4 5 4 6 4 5 4 6 4 5 4 6 Colour 0 372 60 0 372 00 0 372 20 0 372 61 0 372 01 0 372 21 0 372 62 0 372 02 0 372 63 0 372 03 0 372 64 0 372 04 0 372 40 0 372 41 0 372 42 0 372 43 0 372 44 0 372 46 0 372 47 0 372 69 0 372 09 0 372 67 0 372 07 0 372 68 0 372 08 End cap 4 5 0 372 70 0 375 86 4 6 0 372 71 6 8 0 372 72 10 10 0 372 73 16 12 0 372 74 Separation and insulation divider Atomatic insertion bridging comb 2 red blocks 10 red blocks 10 blue blocks Test socket 0 375 86 0 375 95 0 375 02 0 375 01 0 375 00 0 375 27 (6) built-in 0 375 95 0 375 05 0 375 04 0 375 03 0 375 27 (6) built-in 0 375 07/08 (5) 0 375 27 built-in 0 375 82 built-in 0 375 85 0 375 87 0 375 95 0 375 02 0 375 01 0 375 00 0 375 27 (6) built-in 0 375 95 0 375 05 0 375 04 0 375 03 0 375 27 (6) 0 375 88 0 375 95 0 375 02 0 375 01 0 375 00 0 375 27 (6) built-in 0 375 05 0 375 04 0 375 03 0 375 27 (6) 0 375 89 0 375 96 0 375 02 0 375 01 0 375 00 0 375 27 (3)(6) built-in 0 375 96 0 375 05 0 375 04 0 375 03 0 375 27 (3)(6) built-in 4 5 0 372 10 0 375 87 4 6 0 372 11 built-in 4 5 0 372 12 0 375 88 4 6 0 372 79 built-in 0 372 80 0 375 90 0 375 05 0 375 04 0 375 03 0 375 27 (6) ASSOCIATED PRODUCTS End stops Label holder for end stop Handle lever mini lever Joining rods for disconnect blocks Blown fuse indicators Shielding 0 372 81 2.5 6 0 372 81 + 0 375 24/25 (1) 0 372 82 0 375 90 0 375 05 0 375 04 0 375 03 CAB 3 0 372 83 0 372 84 0 375 90 0 375 05 0 375 04 0 375 03 0 375 27 (6) 0 372 85 0 375 90 0 375 05 0 375 04 0 375 03 0 372 86 0 375 90 0 375 05 0 375 04 0 375 03 0 375 27 (6) 0 372 54 0 375 88 0 375 95 4 5 0 372 55 0 375 89 0 375 96 0 375 02 0 375 01 0 375 00 Logicab 2 0 372 56 0 375 89 0 375 96 0 375 02 (2) 0 375 01 (2) 0 375 00 (2) Red catalogue numbers: New products 11

terminal blocks with screw connection Viking TM 3 n Characteristics and dimensions (mm) V2 polyamide according to UL 94, 960 C according to IEC EN 60695-2-11 Connecting blocks Voltage (V) Current (A) Nominal cross-section IEC CSA UL Ie IEC CSA UL IEC CSA UL (mm 2 ) (AWG) (AWG) 371 00/20/30/60 27 24 20 20 2.5 12 12 371 01/21/31/61 36 32 30 30 4 10 10 371 02/62 48 41 50 50 6 8 8 800 600 600 371 03/63 63 57 60 60 10 6 6 371 04/64 85 76 85 85 16 4 4 371 05/65 138 125 115 115 35 2 2 371 07/67 27 24 20 20 2.5 12 12 371 08/68 500 300 300 36 32 30 30 4 10 10 371 09/69 36 32 30 30 4 10 10 371 66 1000 600 600 213 192 200 200 70 000 000 371 77 36 32 30 30 4 10 10 800 600 600 371 78 48 41 50 50 6 8 8 Cat.No 371 51: see blocks for sensors IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059 Ie: Rated current NF C 15100 table 52H, column 4 371 00/01/02/ 03/20/21/30/31/60/61/ 62/63/77/78 52.2 45.8 46.4 53.9 371 04/05/64/65 57.1 54.5 62.9 70.4 Cat.No 371 66 64.6 62 63 70.5 Blocks for protection conductor Voltage (V) Nominal cross- section IEC CSA UL IEC (mm 2 ) CSA (AWG) UL (AWG) 371 70 2.5 12 12 371 71 4 10 10 371 72 6 8 8 800 600 600 371 73 (1) 10 6 6 371 74 (1) 16 4 4 371 75 (1) 35 2 2 371 76 - - - 35 - - 371 77 4 10 10 800 600 600 371 78 6 8 8 371 79 500 300 300 4 10 10 IEC 60947-7-1/7-2, CSA no. 22-2 no. 158, UL 1059 (1) PEN terminal blocks 371 70/71/72/73 371 74/75 Cat.No 371 76 52.2 45.8 46.4 53.9 371 77/78 52.2 45.8 54.5 Cat.No 371 79 57 54.4 63 70.5 46.4 53.9 49 36.8 50.5 51.2 58.7 29.3 41.5 371 09/69 57 54.4 51.2 58.7 Approved by ATEX: LCIE 07 ATEX 0010 U-0081 371 07/08/67/68 74.8 72.2 62.5 70 II 1 or 2 G or D Ex e/i/td/id II The terminal blocks with screw connection covered by this certificate are 1-, 2- and 3-level connecting terminal blocks, and blocks for protection conductor with metal (1) and plastic base (detailed list on p. 8) The main characteristics are: Operating temperature: - 30 C to + 55 C Maximum temperature of materials: + 85 C Working voltage acc. to EN 60079-7: 1-level terminal blocks: 500 V Blocks with 2 entries - 2 outlets: 250 V 2 and 3-level terminal blocks: 250 V Rated current: Conductor 2.5 cross-section (mm 2 ) 4 6 10 16 35 70 Rated current (A) 18 23 30 42 57 93 144 Attestation of conformity of component for the customer is available on request (1) Except for Cat.No 371 76 Disconnect terminals 371 80 500 300 300 15 15 15 371 81 ou 371 80 + 375 15 250 250 250 6.3 6.3 6.3 371 82 371 83 2.5 371 84 500 300 300 15 15 15 371 85 371 86 371 87 250 250 250 10 10 10 10 IEC 60947-7-1/7-3, CSA no. 22-2 no. 158, UL 1059 Power according to EN 60947-7-3 (1): With or without blown fuse indicator Cat.No 375 25 Cat.No 371 80 71.2 26.8 46.4 53.9 Voltage (V) 371 81/82/83/85 83.1 90.6 91.6 71.2 Current (A) IEC CSA UL IEC CSA UL 26.8 52.3 59.8 371 84/86 76.3 83.8 Nominal cross- section IEC (mm 2 ) CSA (AWG) 84.2 71.2 UL (AWG) 12 12 Short-circuit Short-circuit + overload Separate blocks Assembled blocks Separate blocks Assembled blocks 371 81 or 4 W / 6.3 A 1.6 W/6.3 A 1.6 W/6.3 A - 371 80 + 375 15 (1) Pvk = 4.75 W Pvk = 2 W Pv = 1.65 W - 371 87 4 W 2.5 W 1.6 W - Pvk = 5 W Pvk = 2.7 W Pv = 1.8 W - 26.8 46.5 54 Cat.No 371 87 65.5 65.5 73 12

Function blocks IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059 371 53/54 71.2 65.9 26.8 Voltage (V) Current (A) Nominal cross- section IEC CSA UL IEC CSA UL 371 55/56 74.8 72.2 IEC (mm 2 ) CSA (AWG) UL (AWG) 371 53 250 - - - - - 2.5 - - 371 54 250 - - 1 - - 2.5 - - 371 55 500 300 300 1 1 1 4 10 10 371 56 12 to 24 12 to 24 12 to 24 32 30 30 4 10 10 Block for actuator Cat.No 371 52 PNE block Cat.No 371 52 Signal Autom ation Bridging com b Cat.No 375 47 Signal To actuators common Phase Neutral 46.5 54 Schematic diagrams Cat.No 371 53 Cat.No 371 54 62.5 70 IEC EN 60947-7-1 Cat.No 371 92 Cat.No 371 55 73.2 Disconnect block for measurement Voltage (V) Current (A) Nominal cross- section IEC CSA UL IEC CSA UL IEC (mm 2 ) CSA (AWG) UL (AWG) 371 92 800 - - 24 - - 4 - - 62 69.5 Cat.No 371 56 + + - - Diode for 371 54/55-1N4007 type 1A - direct current = 1 A - peak inverse voltage 1000 V - inverse current 5 µa at 25 C Wiring principle for measurement blocks Cat.No 371 92 Ammeter circuit Wattmeter circuit Blocks for sensors and actuators/pne 371 51 371 52 IEC 60947-7-1/7-2, CSA no. 22-2 no. 158, UL 1059 Ie: Rated current NF C 15100 table 52H, column 4 371 51/52 Wiring principle Block for sensor Cat.No 371 51 Signal 84.5 Autom ation Bridging com b Cat.No 375 47 38.8 Voltage (V) 67.4 74.9 Powersupply orph -N Signal Current (A) IEC CSA UL Ie IEC CSA UL Sensors Powersupply (shared) Nominal cross- section IEC CSA UL (mm 2 ) (AWG) (AWG) 400 300 300 27 24 20 20 2.5 12 12 Normal position Test position Stripped lengths (mm) Screw terminal pitch (mm) Short-circuit position Per circuit: 2 x Disconnect blocks for measurement Cat.No 371 92 4 x Measurement sockets for Ø4 mm plug Cat.No 375 77 1 x End cap Cat.No 375 57 1 x Shunt with Ø4 mm plugs L1 L2 L3 N PE Rigid or flexible wire 5 6 6 to 8 8 10 10 to 12 12 13 to 17 15 14 to 18 22 15 to 22 10 x Disconnect blocks for measurement Cat.No 371 92 12 x Measurement sockets for Ø4 mm plug Cat.No 375 77 1 x End cap Cat.No 375 57 3 x Shunts with Ø4 mm plugs Protection against fire and panic risks in public buildings/ute C 12-201 guide Art. EL 3, definitions: "Security installations are those that have to be put into or maintained in service to ensure the evacuation of the public" or facilitate the intervention of the first-aid Art. EL 16, power supply circuits in security installations section 1a: " the corresponding junction or deviation devices and their enclosures except for the waterproofing systems must satisfy the incandescent wire test defined in the standard in force, the temperature of the incandescent wire being 960 C" Viking 3 terminal blocks satisfy the incandescent wire test 960 C according to standard IEC 60695-2-11 13

terminal blocks with spring connection Viking TM 3 n Characteristics and dimensions (mm) V2 polyamide according to UL 94, 960 C according to IEC EN 60695-2-11 Connecting blocks Voltage (V) Current (A) Nominal cross- section IEC CSA UL Ie IEC CSA UL IEC CSA UL (mm 2 ) (AWG) (AWG) 372 00 372 01 36 32 20 20 4 12 12 372 02 800 600 600 48 41 30 30 6 10 10 372 03 63 57 50 50 10 8 8 372 04 85 76 65 65 16 6 6 372 07 372 08 500 300 300 30 30 10 10 372 09 372 20 372 21 372 40 372 41 36 32 4 372 42 20 20 12 12 372 43 372 44 800 600 600 372 46 372 47 372 60 372 61 372 62 48 41 30 30 6 10 10 372 63 63 57 50 50 10 8 8 372 64 85 76 65 65 16 6 6 372 67 500 300 300 30 30 372 68 36 32 4 10 10 372 69 800 600 600 20 20 12 12 IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059 Ie: Rated current NF C 15100 table 52H, column 4 Blocks for protection conductor Voltage (V) Nominal cross- section IEC CSA UL IEC (mm 2 ) CSA (AWG) UL (AWG) 372 10 372 11 372 12 4 372 70 10 10 372 71 800 600 600 372 72 6 372 73 (1) 10 8 8 372 74 (1) 16 6 6 372 79 4 10 10 IEC 60947-7-2, CSA no. 22-2 no. 158, UL 1059 (1): PEN terminal blocks Function blocks 372 54 500 300 300 1 1 1 372 55 372 56 12 to 24 12 to 24 12 to 24 - - - IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059 372 00/01/20/ 21/60/61/70/71 372 02/62/72 54 42.1 49.6 372 04/64/74 84.9 Voltage (V) Current (A) Nominal cross- section IEC CSA UL IEC CSA UL 66.4 372 10/11/40/ 41/42/43/44 69.4 44 51.5 IEC (mm 2 ) 372 03/63/73 74.3 372 09/12/46/ 47/54/69/79 84.7 CSA (AWG) 48.7 56.2 UL (AWG) 4 14 14 Schematic diagrams Cat.No 372 54 Diode for 372 54/55-1N4007 type 1A - direct current = 1 A - peak inverse voltage 1000 V - inverse current 5 µa at 25 C 372 80 500 300 300 15 15 15 372 81 or 372 80 + 375 15 250 250 250 6.3 6.3 6.3 372 82 372 83 372 84 500 300 300 15 15 15 372 85 372 86 IEC 60947-7-1/7-3, CSA no. 22-2 no. 158, UL 1059 Cat.No 372 80 80 27 Cat.No 372 55 372 81/82/83/85 Cat.No 372 56 Approved by ATEX: LCIE 07 ATEX 0010 U-0081 II 1 or 2 G or D Ex e/i/td/id II The terminal blocks with spring connection covered by this certificate are 1- and 2-level connecting terminal blocks, and blocks for protection conductor with metal base (detailed list on p. 10) The main characteristics are: Operating temperature: - 30 C to + 55 C Maximum temperature of materials: + 85 C Working voltage acc. to EN 60079-7: 1-level terminal blocks: 500 V Blocks with 2 entries - 2 outlets: 500 V 2-level terminal blocks: 250 V Rated current: Conductor cross-section (mm 2 ) 4 6 10 16 Rated current (A) 23 30 42 57 51.3 58.8 46.6 54.1 Attestation of conformity of component for the customer is available on request Disconnect blocks 42.1 49.6 Voltage (V) Current (A) Nominal cross- section IEC CSA UL IEC CSA UL Power according to EN 60947-7-3 91.7 80 27 IEC (mm 2 ) CSA (AWG) UL (AWG) 2.5 14 14 Short-circuit Short-circuit + overload Separate blocks Assembled blocks Separate blocks Assembled blocks 372 81 ou 4 W / 6.3 A 1.6 W / 6.3 A 1.6 W / 6.3 A - 372 80 + 375 15 (1) Pvk = 4.75 W Pvk = 2 W Pv = 1.65 W - (1): With or without blown fuse indicator Cat.No 375 25 42.1 49.6 83 90.5 52.3 59.8 372 07/08/55/56/67/68 42.4 89.1 Cat.No 372 84/86 83.3 27 80 56.1 63.6 76.3 83.8 46.5 54 14

accessories for terminal blocks Viking TM 3 Stripped lengths (mm) Spring terminal pitch (mm) Rigid or flexible wire 5 6 8 to 12 8 10 8 to 13 12 8 to 15 Protection against fire and panic risks in public buildings/ute C 12-201 guide Art. EL 3, definitions: "Security installations are those that have to be put into or maintained in service to ensure the evacuation of the public" or facilitate the intervention of the first-aid Art. EL 16, power supply circuits in security installations section 1a: " the corresponding junction or deviation devices and their enclosures except for the waterproofing systems must satisfy the incandescent wire test defined in the standard in force, the temperature of the incandescent wire being 960 C" Viking 3 terminal blocks satisfy the incandescent wire test 960 C according to standard IEC 60695-2-11 n Characteristics and dimensions (mm) End stops Cat.No 375 10 52.7 45.9 46.4 53.9 Cat.No 375 12 51.5 59 114 Cat.No 375 11 48.4 31.8 39.3 Cat.No 375 13 49.7 40.3 38.8 46.3 End caps Thickness (mm) 375 50 2 375 51 2.5 375 52 2 375 53 2 375 54 2.5 375 55 2 375 56 1.4 375 57 1.4 375 86 1 375 87 1.1 375 88 1.1 375 89 1.1 375 90 2 Shielding clamps Mounting on bar 10 x 3 Cat.No 375 34 Separation and insulation dividers Thickness (mm) 375 54 2.5 375 60 2.5 375 61 2.6 375 62 2.5 375 63 2.5 375 95 2.8 375 96 2.7 Mounting on rail with accessory Cat.No 364 69 Equipotential bridging combs/bars Cross-section (mm 2 ) 375 01 2.5 375 02 2.5 375 04 4 375 05 4 375 07 6 375 08 6 375 40 10 375 42 16 375 44 35 375 46 2.5 375 47 2.5 375 82 10 375 85 16 Mounting on plate A B C M4 D A B C D 375 30 13.5 18 26 5.6 375 31 20 20.3 31.4 5.3 375 32 24.8 26 40 5.3 15

Notes

Setiabudi Building II Lt. 6 Suite 603 Jl. H.R. Rasuna Said, Kav 62 Jakarta 12920 Telp : (+62-21) 525 0608 Fax : (+62-21) 525 5935 E-mail : sales.indonesia@legrand.co.id IDNV12C/GB-Edition Dec/12 Bandung : Komp. Setrasari Plaza II /A 11 Bandung 40152 Telp. : (+62-22) 202 0751 Fax. : (+62-22) 201 1460 E-mail : legrand.bandung@legrand.co.id Surabaya : G Walk Shop House W2 No. 22 Citraland, Surabaya - Indonesia Telp. : (+62-31) 5743 1080 (Hunting) Fax. : (+62-31) 5743 1081 E-mail : legrand.surabaya@legrand.co.id Medan : Jl. Thamrin 20 B Medan - Indonesia Telp. : (+62-61) 451 7396, 451 7431 Fax. : (+62-61) 451 7431 E-mail : legrand.medan@legrand.co.id