Hybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill

Similar documents
Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Examples of Electric Drive Solutions and Applied Technologies

Pressurized Air Cooled Generators

Experiences in a Motor Protection Retrofit

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Basics of Paralleling

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Aswan high dam - Distributed control system AUTOMATION

About TECO-Westinghouse

ABB POWER SYSTEMS CONSULTING

ELECTRIC DRIVES N.K. DE P.K. SEN

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Testing Variable Speed Induction Motor

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Cost Affective Dockside Crane Retrofit Utilizing Existing SCR s

How to: Test & Evaluate Motors in Your Application

Project Summary Fuzzy Logic Control of Electric Motors and Motor Drives: Feasibility Study

Power Factor Improvement

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

CRITICAL ISSUES DOWNTOWN CONTINGENCY PORTFOLIO

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Dual Power. Protection. Protection

Remy HVH250 Application Manual Remy HVH250 Application Manual

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

International Journal of Advance Research in Engineering, Science & Technology

Battery Technology for Data Centers and Network Rooms: Site Planning

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Dead bus synchronizing. Applications

HVDC. TMT&D provides the best and most economical HVDC system.

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

Pump Station 7 Improvements

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

Service and Rehabilitation Electrical Power Systems

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Seabrook Substation Reliability Improvement Project

EMERGING REQUIREMENTS

IEEE-PES Chicago Chapter Presentation November 11, Smart Grid. Mike Born. Principal Engineer, Capacity Planning

SECTION VARIABLE FREQUENCY DRIVE UNITS

Smart FS medium frequency induction crucible furnace: Small capacity furnace solutions from ABB

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design

Power Electronics

GE Energy. Variable Frequency Transformers Grid Inter-tie

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Journal of Engineering Sciences and Innovation Volume 2, Issue 4 / 2017, pp

Scheme - I. Sample Question Paper

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers

All-weather systems that promote VFD efficiency and durability in any environment usa.siemens.com/perfectharmony

Variable Frequency Drive Basics

Benefits of a Cooling Tower VFD Retrofit

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

MOTORS, VOLTAGE, EFFICIENCY AND WIRING. A Deeper Understanding

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

Owner s Manual. PowerVerterDC-to-AC Inverter

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

Microgrid solutions Delivering resilient power anywhere at any time

Interconnection Feasibility Study Report GIP-226-FEAS-R3

Enhanced Process Efficiency Hot gas expander replacement

AC Adjustable Speed Drives (ASD s)

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

Development of Emergency Train Travel Function Provided by Stationary Energy Storage System

Variable speed control of compressors. ABB drives control the compressors of the world s longest gas export pipeline

Generation Interconnection Facilities Study For

Within the 300 GW total, the Energy Department estimates that 54 GW will be required from offshore wind to feed the large coastal demand centers.

T5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati

Inverter control of low speed Linear Induction Motors

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

World s Largest Air-cooled Turbogenerator in operation

3.0 Radial Distribution Systems

Product information. ECOSS Electronic compact starter for wound rotor drives

Review paper on Fault analysis and its Limiting Techniques.

OBJECTIVES LCC HVDC SYSTEMS VSC HVDC SYSTEMS COMMON EQUIPMENT DIFFERENT OPTIONS ECONOMIC IMPACTS CONCLUSIONS

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

PowerFlex 6000 Medium Voltage AC Drives

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

PLC Based Closed Loop Speed Control Of DC Shunt Motor

Guide. Services Document No: GD-1401 v1.0. Issue Date: Title: WIND ISLANDING. Previous Date: N/A. Author: Heather Andrew.

15 Nelson-Marlborough Regional Plan

Variable frequency transformer for asynchronous power transfer

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

Designing Drive Systems for Low Web Speeds

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Successful upgrading of old induction melting furnaces a contribution to saving energy and increasing melting rates

VFT Response to a Breaker Trip and Runback Event

Transcription:

Hybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill Michael A DeCarli TM GE Automation Systems, LLC 2060 Cook Drive Salem, VA 24153, USA Tel: 540-283-2118 Fax: 540-283-2395 E-mail: Michael.DeCarli@TMEIC-GE.com Antonio Giordano Electrical Manager, ILVA HSM #1 Taranto, Puglia, ITALY Tel: +390994813896 E-mail: Tna1Ele.Taranto@rivagroup.com Brent Jones TM GE Automation Systems, LLC 2060 Cook Drive Salem, VA 24153, USA Tel: 540-283-2121 Fax: 540-283-2395 E-mail: Brent.Jones@TMEIC-GE.com Keywords: Induction Motor, Finishing Mill, Tandem Motor, DC Motor INTRODUCTION In 2006 the ILVA #1 Hot Strip Mill in Taranto, Italy undertook a project to upgrade the existing Finishing Mill main drives. The drive systems for Finishing Mill Stands F2 and F3 were each upgraded by replacing one armature of the existing three-armature DC motor with a new higher capacity AC Induction motor. The new drive systems were successfully commissioned in 2009. This upgrade philosophy is a conservative, and potentially lower cost alternative to the traditional practice of simultaneously replacing all tandem armatures with a single large AC main drive motor. UPGRADE OVERVIEW The existing layout of the six-stand Finish Mill at ILVA HSM #1 in Taranto, Italy consisted of three-armature DC motors on stands F1-F5 and a two-armature DC motor on F6. The 17 armatures were all identical, rated 2,630 HP, 700 V, 3000 A. Each stand motor had a stub shaft with one pedestal bearing, and each armature had one pedestal bearing. Thus, F1 F5 motors had three armatures with four pedestal bearings and a combined rating of 7890 HP. The F6 motor had two armatures with three pedestal bearings and a combined rating of 5260 HP. The goal of this re-powering project was to increase the horsepower of the Finishing Mill enabling ILVA to run a more diverse product range. The upgrade was intended to be accomplished in multiple phases. The first phase of the re-powering increased the HP of stands F2, F3, and F6. Subsequent phases will upgrade the HP of the remaining stands and allow ILVA to replace all the DC motors with AC Motors. Stands F2 and F3 were selected to be upgraded first because they are set up to take the largest draft during rolling and would benefit the most from having more power available. Stand F6 was upgraded because it was possible to increase the HP of this stand without purchasing any new motors. The power of Stands F2 and F3 was increased by replacing the front 2,630 HP DC armatures with 4,000 kw (5,362 HP) AC motors. These new motors were designed to fit the existing DC motor base, operate coupled to the remaining two DC armatures, and increase the power of these two FM stands. The shaft of the AC motors was designed to transmit twice the output torque of each new AC motor. This shaft design would allow ILVA to eventually replace the two remaining DC armatures on each stand with a second induction motor in the future. New heavier pedestal bearings were supplied to accommodate the increased motor weight and shaft size. The modification of stands F2 and F3 can be seen in Figure 1. The upgrade of Stand F6 was straightforward. The foundation and motor base were already configured for a three-armature main drive. One of the customer s existing spare DC armatures was installed at Stand F6 to convert it from a two-armature to a three-armature configuration. A new single larger DC power supply was installed to support the increased power demand of the F6 AIST_ILVA-r3 page 1 of 8

stand. This conversion was made possible because the AC upgrade to stands F2 and F3 enabled ILVA to have 2 additional spare DC motors. DC 2630HP-175/450rpm DC 2630HP-175/450rpm DC 2630HP-175/450rpm New IM 5362HP-175/450rpm Existing Configuration DC 2630HP-175/450rpm DC 2630HP-175/450rpm New Tach New Configuration Figure 1: Original and Final Tandem Motor Configurations for F2 and F3 New IEGT PWM AC Main drive equipment was installed in the existing DC Thyristor Electrical Room, with new transformers mounted outdoors. A new 66 kv feeder was installed for each new AC drive. Additional 10 kv switchgear was installed to supply two new power centers, one for the new F6 motor field exciters and one for the new AC drive cooling water system. A new motor control center was installed to support the additional auxiliary loads associated with the new motors and drives. This equipment was designed to support both Phase 1 and Phase 2 of the mill re-power. The AC motor is controlled as a torque follower of the remaining two DC armatures. This control scheme minimizes the impact on the existing control system for the Finishing Mill and does not affect speed coordination between the main drives of the Finishing Mill stands. The faster response of the AC drives compared to the Thyristor Power Supplies (TPS) makes the AC drive a suitable torque or current follower. The remaining two armatures for each stand continued to be fed by the existing TPS, using a new tachometer for speed feedback. Phase 2 of this upgrade will duplicate the strategy used for the upgrade of Stands F2 and F3, upgrading the power of Stands F4 and F5. A summary of the original and upgraded main drive ratings is shown in Table 1. AIST_ILVA-r3 page 2 of 8

Original Motor Configuration Stand First Motor Second Motor Third Motor Total Power F1 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F2 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F3 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F4 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F5 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F6 DC 2630 HP DC 2630 HP None 5260 HP New Motor Configuration (including Phase 2) Stand First Motor Second Motor Third Motor Total Power F1 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP F2 IM 5362 HP DC 2630 HP DC 2630 HP 10622 HP F3 IM 5362 HP DC 2630 HP DC 2630 HP 10622 HP F4 * IM 5362 HP DC 2630 HP DC 2630 HP 10622 HP F5 * IM 5362 HP DC 2630 HP DC 2630 HP 10622 HP F6 DC 2630 HP DC 2630 HP DC 2630 HP 7896 HP *Future - Phase 2 Table 1: Original and Final Tandem Motor Power Comparison When both phases of the upgrade are complete, the total power of F1 and F6 will be 7,890 HP each, and of F2 F5 will be 10,620 HP each. The DC armatures removed from the four upgraded stands will be used as spares. Motor Type APPLICATION CONSIDERATIONS A synchronous motor was originally considered for this application, because most modern hot strip mills feature synchronous motors as the main drives for the Finishing Mill. However, the space available to install the new motor was restricted by the existing foundation and remaining DC armatures. The rotor diameter required for the new motor rating would fit the existing space regardless of motor type, but the motor length was the critical restriction. Both types of AC motor designs were carefully studied, and it was decided that there was insufficient space for the collector ring assembly required by a synchronous motor. Therefore an induction motor was selected for this installation because the required motor length would be shorter for the same desired rating. Additionally, the motor manufacturer had a great deal of experience making induction motors near this rating of 5362HP, 175/450 RPM since it is similar to the ratings of motors used in cold mill applications. These factors made an induction motor the preferred choice for this project. AIST_ILVA-r3 page 3 of 8

Figure 2: Induction Motor Designed for DC motor Base & Foundation Torque Amplification Factor Because the new motor is directly coupled to an existing drive system, and the new motor shaft would deliver the combined tandem motor output torque to the load, it was necessary to study the mechanical system to confirm that no significant mechanical resonance would occur during operation. Torque Torque Peak = Applied TAF Equation 1: Definition of Torque Amplification Factor Figure 3: Physical System Studied for TAF Analysis AIST_ILVA-r3 page 4 of 8

Figure 4: Model Representation for TAF Analysis Stand F2 Stand F3 EXISTING 3 DC 1 INDUCTION MOTOR, 2 DC FUTURE 2 INDUCTION EXISTING 3 DC 1 INDUCTION MOTOR, 2 DC FUTURE 2 INDUCTION MOTOR 1 TO MOTOR 2 1.1 1.3 1.2 1.4 1.4 1.5 MOTOR 2 TO MOTOR 3 1.5 1.5 N/A 1.7 1.7 N/A MOTOR 3 TO COUPLING 1.8 1.9 1.7 1.9 2.0 1.9 COUPLING TO GEARBOX 1.8 1.9 1.7 1.9 2.0 1.9 GEARBOX TO SHAFT 1.9 1.9 1.9 1.7 1.7 1.7 SHAFT TO PINION 1.9 1.9 1.9 1.7 1.7 1.7 PINION TO TOP SPINDLE 1.9 1.9 2.0 1.7 1.7 1.9 TOP SPINDLE TO TOP ROLL 1.9 1.9 2.0 1.7 1.7 1.9 PINION TO BOTTOM SPINDLE 1.9 1.9 1.9 1.7 1.7 1.7 BOTTOM SPINDLE TO BOTTOM ROLL 1.9 1.9 1.9 1.7 1.7 1.7 Table 2: Calculated Torque Amplification Factor The calculated TAF values are show in Table 2, above. Although in some cases the TAF of the new drive system would exceed the existing TAF, the calculated TAF values were considered to be acceptable. The new motors were designed with consideration for the calculated TAF values. Construction and Installation The existing bases were modified by installing additional anchor bolts to support the increase in power. One extra anchor bolt was added to each side of each existing base. Figure 2 illustrates the location of the additional anchor bolts. Because the bottom of the motor foundation was accessible, a hole was drilled all the way through the existing motor foundation and the new anchor bolt was inserted into this new hole and attached to a steel plate at the underside of the motor foundation. AIST_ILVA-r3 page 5 of 8

The length of the opening in the existing base was also lengthened by approximately 2 to remove interference between the base and the stator covers of the new motor. Figure 5 shows the installed view of the F2 tandem motors. Figure 5: F2 DC-DC-AC tandem motors Motor Auxiliary Systems The existing DC motors for F2 and F3 were converted from three armatures in parallel to two armatures in parallel. Existing buswork for the front motor was removed and replaced with new 3 phase AC cable. The existing front DC motor was a Drip-Proof, Separately Ventilated (DPSV) machine, while the new motors are Totally Enclosed Water-to-Air Cooled (TEWAC). This required some changes to the plant auxiliary systems. The existing cooling air ducts under the front motor were sealed off because no cooling air was required for the new TEWAC motor. The AC motors utilize plant water to cool the motor internal air through an air-to-water heat exchanger installed on top of the motor. The new AC drive cabinets are cooled directly by an integrated, self-contained de-ionized water cooling loop. This de-ionized loop is cooled by plant water through a water to water heat exchanger. Often multiple main drives are cooled by a common de-ionized water cooling loop, but in this case there was no space available for a central cooling water skid, so the cooling water equipment was close coupled to each drive cabinet lineup as shown in Figure 6. AIST_ILVA-r3 page 6 of 8

Figure 6: AC Main Drive Outline The existing bearing lubrication system was re-used with only minor piping modifications to supply the bearings for the new motors. Drive System An important consideration when implementing this new drive system was how to successfully integrate the new AC Drive into the existing system with older generation DC drives. After thorough analysis it was decided to configure the new AC drive to run as a slave (torque follower) with a torque reference from the digital front end of one of the DC drives acting as the master. The DC drive was chosen to be the master due to its slower response time. The new AC Drive has a maximum torque current response of 600 radians per second while the DC drives are limited to 300 radians per second. A diagram of the modified main drive control scheme is shown in Figure 7. Additionally, keeping the DC drive as the master controller minimized disturbances to the existing control system which reduced both the cost and risk associated with the project. Sequencing logic in the existing mill controllers was modified to accept inputs from the new motors and drives. Figure 7: Control Scheme Diagram AIST_ILVA-r3 page 7 of 8

One feature of the existing DC motor control scheme that was required to be maintained in the new system was the ability to operate the mill stand with any single motor out of service. In the previous configuration, any single DC armature could be removed from service and the stand would operate with power reduced to 5260HP. In the new configuration, either DC armature or the AC motor can be removed from service and the worst case result is the same 5260HP that was available with the DC motor scenario. However, due to the simplicity and reduced maintenance of the AC Induction motor, it is unlikely that the mill will operate with the AC motor out of service. In this case with either DC armature out of service the stand power will be reduced from 10,620 HP to 7,990 HP which is still more power than was available with three DC armatures. Another feature of the new drive system is overall improvement in system efficiency compared to the existing DC motor drive system. The new IEGT PWM AC drive efficiency is rated at >98.5%. This is an improvement of approximately 5% compared to the efficiency of the DC thyristor converters which had been used with the DC motors. The new Induction motor efficiency is roughly 94% at rated load, compared to typical DC motor efficiency of 80%. Although it is believed that the energy savings generated by this upgrade was substantial, energy savings was not used as a justification for this project and the benefits have not been rigorously analyzed. Project Schedule PROJECT EXECUTION OVERVIEW During the routine annual shutdown of 2008, the F6 stand was upgraded with the third armature and new DC drive. Preliminary work was also done to prepare for the later installation of the AC drives in 2009. New feeders were added to the mill electrical distribution system for the new drives and motors, new drive isolation transformers were installed outdoors, and new AC drives were installed in the existing TPS room of the mill and during this shutdown. Because of unusually low orders in 2008, ILVA decided to shut down the #1 HSM in December, 2008. The inboard DC armatures of Stands F2 and F3 were removed by ILVA before the end of 2008. In January 2009, work began to install the new AC motors and commission the drive system. In May 2009, the new drive system of Stands F2 and F3 had been exercised as much as possible without rolling metal through these stands, and the commissioning was declared complete. A benefit of the difficult economic times is that ILVA has been able to complete the majority of this phase of the re-powering without additional downtime and lost production. TMEIC GE will return to ILVA s #1 HSM for a period of production support after the mill is restarted in 2010. SUMMARY The front DC armatures of two three-armature Finishing Mill main drives were replaced by larger capacity AC Induction motors to increase the power of those Finishing Mill Stands with minimal disturbance to the existing DC armatures, DC drives, and mill automation system. Under special conditions like those at Ilva, this modernization philosophy has significant potential for the upgrade of other mills featuring tandem DC armatures which are facing obsolescence or power limitation issues. With proper engineering analysis to verify the feasibility of this solution, it is a conservative alternative to the traditional practice of simultaneously replacing all tandem armatures with a single large AC main drive motor. REFERENCES 1. H. Hosoda, S. Kodama, and R. Tessendorf. Large PWM Inverters for Rolling Mills, Iron & Steel Technology, Vol.5, No.1, January 2008 2. R. Tessendorf. Synchronous and Induction Motors for Main Drive Applications, Submitted for Publication in Iron & Steel Technology, February, 2010 AIST_ILVA-r3 page 8 of 8