Laser Service Factory-assembled Panelboards

Similar documents
I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels

Series Rated / Fully Rated Tables. Lighting and Appliance Panelboards. Panelboard Special Features

Panelboards Circuit Breaker / Lighting and Distribution

Jefferson Public Works Shop Building 2011

QMB Fusible Panelboards

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

PANELBOARDS SECTION 1

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Integrated Power Center

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

PowerPact B. Molded case circuit breakers and switches from A

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

Lighting and Power Distribution Panelboards

PANELBOARDS C1/C2 SECTION 6

Division 1 Explosionproof Panelboards

SECTION PANELBOARDS

2015 $22. Digest 177. digestplus-us.schneider-electric.com

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Application guide. Tmax Link OEM UL 891 Switchboard Program

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Quik-Spec Coordination Panelboard Specifications

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

NQOD Circuit Breaker Panelboards

Thermal-Magnetic For Mining Applications Class 600

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

CIRCUIT BREAKER PANELBOARDS

22.000A IR. Catalog Number. Price $

NQOD Circuit Breaker Panelboards

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers

Lighting Panelboards. P2 Panelboards

Type MP-T Type MP-HT Type MP-MT

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

A. Submit manufacturer's literature and technical data before starting work.

Service Entrance Methods

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

8 PANELBOARDS. Series Ratings For NQOD, NF and I-LINE Panelboards Class 1630, 1670,

Pow-R-Line 3E Panelboard

Cutler-Hammer. January 2001

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8

Section 4 Square D QO Loadcentres

Selection and application guide

X1PB: Explosionproof Panelboards

Fused Coordination Panelboard

Submittal Transmittal

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Proline Panelboard and breakers

For Options, Modifications and Accessories, see pages Discount Schedule A6

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Brown & Heim Reviewed by: Brandon Jachimski Brown & Heim Reviewed on:

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Miniature Circuit Breakers

I-Line Combo Panelboard

Diesel Generator Set Model DFED 60 Hz

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Panelboards and Lighting Controls

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

Intelligent Choice for Prestigious Buildings

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features

ATX DPD Series Distribution Panelboards Flameproof

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Quality and Innovation for Global Solutions

Revised P1 Panelboards

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Selection and application guide

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Integrated Power Center 2 (IPC2) Space saving designs that save time and reduce costs

Section 2 HomeLine Loadcentres

Contents. 4 Loadcentres

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Control Circuit Protection

Eylander Electric Inc

Bussmann series Quik-Spec Coordination Panelboard

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

Panelboards. Panelboards Contents

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Power distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards

Transcription:

Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page 3 Application and General Information......................... Page 3 Pricing Procedure........................................ Page 5 NQ Factory-assembled Panelboards......................... Page 6 NF Factory-assembled Panelboards......................... Page 9 I-Line Factory-assembled Panelboards...................... Page 12 Frequently Asked Questions.............................. Page 14

Product Overview Product Overview The Square D brand represents the commitment to provide the best electrical products in the industry to our customers. Now we re providing them faster and easier than anyone else. Save time and money with our new Laser Service, a quick-ship process for factory-assembled Square D NQ, NF, and I-Line panelboards. This product offering comes with a broad range of ratings and features to cover our customers lighting and distribution panelboard needs. Options are available for 3-, 5-, and 10-day on-site delivery after the day the order is placed. Laser Service Program Features Simple and easy process for short lead-time factory assembled panelboards Includes factory-assembled NQ, NF and I-Line panelboards Broad product offering to cover a majority of lighting and distribution panelboard applications Laser offers three options for on-site delivery: Laser 3-day: select offer which covers the most common options for NQ and NF panelboards Laser 5- and 10-day: broader offer for NQ, NF and I-Line panelboards Application and General Information Lighting Panelboard Product Offering NQ and NF Panelboards Voltage and System: Available for 3-, 5-, and 10-day on-site delivery: NF: 120/240 Vac, 208Y/120 Vac, 240 Vac, and 480Y/277 Vac NQ: 120/240 Vac, 208Y/120 Vac, and 240 Vac Available for 5- and 10-day on-site delivery: NF: 240 Vac 3 Phase 3-Wire Grounded B Phase NQ: 240 Vac 3 Phase 3-Wire Grounded B Phase and 48 Vdc 2-Wire s Rating: 100 600 A main circuit breaker or main lugs only Variety of branch circuit breaker options available, including specialized circuit breakers Aluminum or copper bus Type 1 available for 3-, 5- and 10-day on-site delivery and Type 3R/5/12 available for 5- and 10-day on-site delivery Special Features/Options: TVSS 200% rated neutrals Feed-through lugs Sub-feed lugs Sub-feed circuit breakers Blank end walls available for 5- and 10-day on-site delivery Padlock attachments and handle lock-offs Trim Front: Surface with door: available for 3-, 5- and 10-day on-site delivery Flush with door: available for 5- and 10-day on-site delivery Surface: hinged available for 5- and 10-day on-site delivery Flush: hinged available for 5- and 10-day on-site delivery Branch Numbering: Horizontal Adhesive: standard option available for 3-, 5- and 10-day on-site delivery 3

Application and General Information Distribution Panelboard Product Offering I-Line Panelboards Voltage Systems: 208Y/120 Vac 120/240 Vac 240 Vac 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac s Rating: 225 1200 A main circuit breaker or main lugs only Copper bus Variety of thermal-magnetic branch circuit breakers Type 1 and Type 3R/5/12 Special Features / Options: TVSS 200% rated neutrals Padlock attachment 4

Pricing Procedure Pricing Procedure NQ and NF Factory-assembled Panelboards 1. Select the base price for main lugs or main circuit breaker from Table 1 (NQ) or Table 13 (NF). Include an equipment ground bar when required. 2. List the branch circuit breakers (bolt-on), and determine the total spaces required. Select the price from Table 2 (NQ) or Table 12 (NF). Include space only charge for future requirements. 3. If total spaces required exceeds the maximum listed, price as two or more panelboards; and add price for sub-feed or feed-through lugs (Tables 5 and 7 (NQ)) or (Tables 16 and 18 (NF)), so the installer can cable between sections. 4. Add price for special features using the appropriate NQ and NF tables. Contact the field office for additional special features. 5. For complete price, total all prices. Order by description. 6. Apply appropriate discount schedule. NQ Factory-assembled Panelboards Example: 208Y/120 Vac, 3Ø4W, 10 kair, 225 A, MLO, Type 1 surface-mount, bolt-on branch circuit breakers, main sub-feed lugs Item Table Number Price 225 A MLO Base Price Table 1 $ 928. (20) 20/1 Bolt-On Table 2 1360. (2) 40/2 Bolt-On Table 2 268. (2) 30/3 Bolt-On Table 2 704. Sub-feed Lugs Table 5 128. Total Price: $3388. NF Factory-assembled Panelboards Example: 480Y/277 Vac, 3Ø4W, 25 kair, fully-rated, copper bus, 100 A, main circuit breaker, Type 1 flush-mount, bolt-on branch circuit breakers Item Table Number Price 100 A Base Price Table 13 $2416. Copper Bus Adder Table 24 458. (13) 20/1 Table 14 1612. (1) 40/2 Table 14 746. (1) 50/3 Table 14 1264. Total Price: $6496. I-Line Factory-assembled Panelboards 1. Select the base price for main lugs or main circuit breaker (Table 26 or 27). Include a solid neutral and ground bar when required. 2. List the branch circuit breakers, and determine total mounting inches required. Include space only charge and mounting inches as required. Price the branches (Table 30). 3. If total space required exceeds the maximum listed, price as two or more panels; and add price for sub-feed lugs (Table 33), so the installer can cable between sections. 4. Add price for special features using the appropriate I-Line tables. 5. For complete price, total all prices. Order by description. 6. Apply appropriate discount schedule. I-Line Factory-assembled Panelboard Example 600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4-piece surface trim without door Item Table Number Price 400 A MLO Base Price Table 26 $ 1866. (8) 60/3 Table 30 8048. (1) 100/2 Table 30 964. (3) 250/3 Table 30 14052. Total Price: $24930. 5

NQ Factory-assembled Panelboards NQ Factory-assembled Panelboards Maximum 240 Vac Lugs and s Table 1: s Rating Base Price (with Solid Neutral) Lugs 2-Pole 3-Pole Branch s NOTE: 120 Vac Shunt trip not available for the 3-day on-site delivery. Standard IC HIC 2-Pole 3-Pole 2-Pole 3-Pole 60 Aa QOB $1192. $1464. QOB-VH $1258. $ 1586. 100 Aa $ 720. $ 832. QOB 1254. 1562. QOB-VH 1382. 1712. 150 A HD 3180. 3530. HG 3840. 4190. QB 2450. 2800. 225 A 772. 928. JD 3980. 4300. JG 4510. 5100. QD 3084. 3434. 250 A JD 4390. 4640. JG 5040. 6020. 400 A 1422. 1634. LA 5366. 6106. LH 7708. 8834. 600 Ab 2082. 2326. LC 9420. 10440. a Feed-through lugs and sub-feed options are not available. b Copper bus standard. Equipment ground bar: $38.00 Table 2: Bolt-on Branch s Description Ampere Rating 1-Pole 120 Vac Bolt-On 2-Pole 120/240 Vac 2-Pole 240 Vac 3-Pole 240 Vac Space Only All Space Only (except QOB-VH see below) 28. 58. 58. 86. QOB VH, Space Only 125 150 A 116. 174. 15 60 A $ 68.c $134. $260.a $ 352. 10,000 AIR Branch s QOB, QOB-H 70 A 208. 296.a 396. 80 100 A 262. 380.a 458. 10,000 AIR Combination Arc Fault Interrupters QOB-CAFI 15 20 A 470. 10,000 AIR Qwik Gard Class A QOB-GFI 15 30 A 272. 488. 15 30 A 92. 212. 462. 40 60 A 212. 462. 22,000 AIR Branch s QOB-VH 70 A 292. 556. 80 100 A 378. 606. 110 125 A 1746.b 150 A 1746.b 22,000 AIR Combination Arc Fault Interrupters QOB-VHCAFI 15 20 A 940. 22,000 AIR Qwik-Gard Class A QOB-VHGFI 15 30 A 294. Specialty Branch s (10,000 AIR) High Intensity Discharge Lighting QOB-HID 15 30 A 78. d 30 ma Equipment Protection QOB-EPD 15 30 A 462. d a UL Listed for use on 3Ø, grounded BØ systems, (5,000 AIR for this application); QOB-H 2-pole available only from 15 100 A. b 2-pole requires 4 vertical spaces; 3-pole requires 6 vertical spaces. c QOB 1-pole available only from 15 30 A. d QOB-HID and QOB-EPD available only in 1-pole. Sub-feed s (3-pole only) lugs or main circuit breaker interior 3-phase. Maximum one (1) circuit breaker per 225 A main lug or 250 A main circuit breaker panelboard; two (2) circuit breakers per 400 600 A panelboard. Table 3: Sub-feed s (110 225 A) Price No. of Poles Ampacity QB QD JDa JGa 2 $1218. $1762. $3020. $4220. 3 110 225 A 1848. 2296. 3370. 5100. Space Only 826. 826. 826. 826. a JD and JG circuit breakers are available from 150 225 A. 6

NQ Factory-assembled Panelboards Table 4: Sub-feed Lugs An additional mains end termination point can be used to feed out to another panelboard or device from the incoming service lines. Available on mains lugs interiors only 1-phase or 3-phase. Feed-through Lugs Sub-feed Cabinet Data Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) Box Height (20 in. W x 5.75 in. D) 225 A 250 A 400 A a 600 A bc Lug Lug Lug 30 50 62 74 86 74 42 56 68 74 86 74 54 56 68 80 80 72 62 74 86 86 84 68 80 a Not available in Type 3R, 5, 12, if sub-feed circuit breaker is over 150 A. b Not available in Type 3R, 5, 12. c 6.75 in. (171 mm) deep box, surface only. Table 5: Sub-feed Lug Wire Range Per Phase not available with MCB s Rating Incoming Outgoing Price per Panel 100 one #6-2/0 Al or Cu one #6-2/0 Al or Cu $128. 225 one 1/0-350 kcmil Al or Cu one 1/0-350 kcmil Al or Cu $128. 400 one 1/0-750 kcmil Cu only one 1/0-750 kcmil Cu only $164. Table 6: Sub-feed Lug Cabinet Data Max. No. of Box Height (20 in. W x 5.75 in. D) Branch Spaces 100 A 225 A 400 A 18 MH26 30 MH32 MH38 MH50 42 MH44 MH50 72 MH50 MH62 84 MH56 MH68 A second set of lugs can be assembled at the opposite end from the mains of the panelboard. They are often used to connect another panelboard or device to the incoming lines. Available on main lugs interiors 1-phase or 3-phase, 225 600 A. Available on main circuit breaker interiors 1-phase or 3-phase, 250 600 A. Not available on panelboard with sub-feed circuit breakers. Table 7: Feed-through Lug Wire Range per Phase s Rating Feed-through Wire Range per Phase $ Price Table 8: 100 A one #6-2/0 Al or Cu 344. 225 A one #6 350 kcmil Al or Cu 344. 400 A one 1/0 750 kcmil or two 1/0 350 kcmil Al or Cu 826. 600 A two 1/0 750 kcmil Al or Cu 826. Max. No. of Branch Spaces Feed-through Lug Cabinet Data Box Height (20 in. W x 5.75 in. D) 225 A 250 A 400 A 600 A Lugs Lugs Lugs a 30 38 50 50 62 62 74 42 38 50 56 68 62 80 72 50 62 68 80 74 84 56 68 68 80 80 a 6.75 in. (171 mm) deep box, surface only. 7

NQ Factory-assembled Panelboards Surgelogic Hard Bus TVSS Model IMA Table 9: Surge Current Rating ka Surge Current Rating and Voltage Model IMA a Voltage 120/240 V; 1Ø3W 208Y/120 V; 3Ø4W 240/120 V; 3Ø4W High Leg 100 $12110. $14310. $14310. 120 13454. 15654. 15654. 160 16386. 18586. 18586. a Panelboard box height with TVSS unit contact your nearest Schneider Electric sales office. Table 10: Options Surgelogic TVSS Options Surge Counter Dry Contacts Price Standard Additional Options 8 Table 11: Enclosures: Additional Options Option Description Additional Information Price Equipment Ground Bar $ 38. Copper Ground Bar Add to Equipment Ground Bar price 52. Insulated/Isolated Ground Bar Add to Equipment Ground Bar price 86. Name Plates Standard white face/black letter laminated bakelite, 1.00 in. x 3.50 in. (25 mm x 89 mm), adhesive-backed Price includes engraving 78. 100 A, 225 A, 250 A 128. Price adder Copper Bus Bars 400 A 388. 600 A Standard 0. Copper Neutral 100 600 A Price adder 132. 200% Rated Neutrals Hinged Trim Weatherproof or Dusttight Cabinets Type 3R, 5, 12 100 A 586. 225 A Add per panel 763. 400 A 950. Trim has piano hinge down one side. Meet door in door specifications. 400 A and 600 A NQ main lugs panelboards with subfeed circuit breakers and 600 A main circuit breaker panelboards are not available with a weatherproof enclosure Door opens by latch; entire trim opens by removing screws. Price adder 646. Use I-Line Panelboard 1516. One blank end-wall and one end-wall with knockouts option available for 3-, 5-, and 10-day on-site delivery Two blank end walls option available for 5- and 10-day on-site delivery Two knockouts end-walls option available for 5- and 10-day on-site delivery Table 12: Enclosures Amperage Type Enclosure On-Site Delivery MLO Type 1 MB 100 600 A MLO Type 3R/5/12 MB No sub-feed circuit breakers allowed with 400 A or 600 A N-3R/5/12. 3-, 5-, and 10-days 5- and 10-days

NF Factory-assembled Panelboards NF Factory-assembled Panelboards Maximum 480Y/277 Vac Use I-Line Panelboards on 480 V 3Ø3W DELTA Applications Table 13: Base Price (With Solid Neutral) Lugs s Rating 3-Pole Standard IC HIC 3-Pole 3-Pole 100 A EDa $1882. EGa $ 2416. 125 A $ 972. EDa 3762. EGa 4976. 150A HD 3620. HG 4398. 225 A JD 4380. JG 5400. 250 A 1152. JD 5140. JG 6180. 400 A 1524. LA 6126. LH 8864. 600 Ab 2622. LC 10884. a Back-fed main circuit breaker. b Copper bus only. Table 14: Branch s Price Per NOTE: 120 Vac shunt trip not available for the 3-day on-site delivery. Ampere Rating Sub-feed s Standard Interrupting 25,000 AIR @ 240 Vac; 18,000 AIR @ 480Y/277 Vac ED Bolt-On Branch High Interrupting 65,000 AIR @ 240 Vac; 35,000 AIR @ 480Y/277 Vac EG Bolt-On Branch 1-Pole Price 2-Pole Price 3-Pole Price 1-Pole Price 2-Pole Price 3-Pole Price 15 60 A $192.a $ 442. $ 748. $324.a $ 746. $1264. 70 A 872. 1046. 1474. 1710. 80 100 A 872. 1046. 1474. 1710. 110 125 A 2210. 2724. 4114. 4754. Space Only 42. 84. 126. 42. 84. 126. a ED and EG 1-pole circuit breakers available only from 15 30 A. All ED and EG branch circuit breakers are UL Listed as HACR type. Table 15: Ampere Rating EDB-EPD Equipment Protection Device Branch s Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR @ 480Y/277 Vac ED Bolton Branch High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR @ 480Y/277 Vac EG Bolt-on Branch 1-pole Price 2-pole Price 3-pole Price 1-pole Price 2-pole Price 3-pole Price 15 60 A $1472. $1596. All 1-pole EDB branches use 2 poles of mounting space. For bell alarm in EPD branch breaker, add 316. to branch breaker Price. Available on 3-phase, 125 600 A main lugs or 125 600 A main circuit breaker interiors: One sub-feed JD or JG circuit breaker per 250 A panelboard Two sub-feed JD or JG circuit breakers per 400/600 A panelboard One sub-feed LA or LH circuit breaker per 600 A panelboard and one JD or JG circuit breaker Table 16: Sub-feed (150 400 A) Number of Poles JD JG LA LH Space 3 $3370. $5100. $4916. $6510. $826. 9

NF Factory-assembled Panelboards Table 17: Sub-feed Lugs An additional mains end termination point can be used to feed out to another panelboard or device from the incoming service lines. Available on main lugs interiors only. Feed-through Lugs Sub-feed Cabinet Data Maximum No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) 42 Lugs 62.00 in. (1575 mm) Box Height [20.00 in. (508 mm) W x 5.75 in. (146 mm) D] 250 A 400 A LA/H 600 A 74.00 in. (1880 mm) Lugs 74.00 in. (1880 mm) 86.00 in. (2184 mm) a 600 A main lug panelboards require a 8.75 in. (222 mm) deep box. b 600 A main circuit breaker panelboards require an 8.00 in. (203 mm) deep, 26.00 (660 mm) wide box. Table 18: Table 19: Sub-feed Lug Wire Range s Rating Sub-feed Wire Range (Per Lug) Price 125 A (2) #10 2/0 Cu or (2) #6 2/0 Al $128. 250 A (2) 1/0 350 kcmil Al/Cu 128. 400 A (2) 1/0 600 kcmil Cu 344. 600 A (4) 4/0 500 kcmil Al/Cu 344. Sub-feed Lug Cabinet Data Lugs a 74.00 in. (1880 mm) b 86.00 in. (2184 mm) Box Height [20.00 in. (508 mm) W x 5.75 in. (146 mm) D] Maximum No. of Branch Spaces 125 A 250 A 400 A 600 A 42 44.00 (1118 mm) 56.00 in. (1422 mm) 74.00 in. (1880 mm) A second set of lugs can be assembled at the opposite end from the mains of the panelboard. They are often used to connect another panelboard or device to the incoming lines. Available on main lugs and main circuit breaker panelboards. Table 20: Feed-through Lug Wire Range s Rating Table 21: Maximum No. of Branch Spaces Price 125 A (1) #6 250 kcmil Al/Cu $344. 250 A (1) #6 350 kcmil Al/Cu 344. 400 A (1) 1/0 750 kcmil Al/Cu or (2) 1/0 300 kcmil Al/Cu 826. 600 A (2) 1/0 600 kcmil Al/Cu 826. Feed-through Lug Cabinet Data Box Height [20.00 in. (508 mm) W x 5.75 in. (146 mm) D] 125 A 100/125 A 250 A 400 A LA/H 600 A (Back-Fed Only) Lugs 42 Lugs 56.00 in. (1422 mm) 68.00 in. (1727 mm) Lugs 62.00 in. (1575 mm) a 74.00 in. (1880 mm) a 600 A main circuit breaker panelboards require an 8.00 in. (203 mm) deep, 26.00 (660 mm) wide box. b 600 A main lug panelboards require a 26.00 in. (660 mm) wide box. Lugs b 62.00 in. (1575 mm) a 74.00 in. (1880 mm) 10

NF Factory-assembled Panelboards Surgelogic Hard Bus TVSS Model IMA Table 22: Surge Current Rating and Voltage Model IMA a Voltage Surge Current Rating ka 208Y/120 V; 3Ø4W 240/120 V; 3Ø4W High Leg 480Y/277 V; 3Ø4W 120 $17304. $17304. $18404. 160 20236. 20236. 21336. a Panelboard box height with TVSS unit contact your nearest Square D/Schneider Electric sales office. Table 23: Options Surgelogic TVSS Options Surge Counter Dry Contacts Price Standard Additional Options Table 24: Enclosures: Additional Options Option Description Additional Information Price Equipment Ground Bar $ 38. Copper Ground Bar Add to Equipment Ground Bar price 52. Insulated/Isolated Ground Bar Add to Equipment Ground Bar price 86. Name Plates Standard white face/black letter laminated bakelite, 1.00 in. x 3.50 in. (25 mm x 89 mm), adhesive backing Price includes engraving 78. 100 A, 250 A 458. Price adder Copper Bus Bars 400 A 624. 600 A Standard 0. Copper Neutral 100 600 A Price adder 132. 200% Rated Neutrals Hinged Trim Weatherproof or Dusttight Cabinets NEMA Type 3R, 5, 12 250 A Panelboards with 200% 762. 400 A rated neutrals are available with sub-feed Add per panel 950. 600 A lugs, feed-through lugs, and main circuit breakers 1262. Trim has piano hinge down one side. Meets door-in-door specifications. Door opens by latch; entire trim opens by removing screws. Price adder 646. (Not available with panelboards having LC/LE/LI/LX/LXI main circuit breakers) 1516. One blank end-wall and one end-wall with knockouts option available for 3-, 5-, and 10-day on-site delivery Two blank end walls option available for 5- and 10-day on-site delivery Two knockouts end-walls option available for 5- and 10-day on-site delivery Table 25: Enclosures Amperage Type Enclosure On-Site Delivery MLO Type 1 MB 100 600 A MLO Type 3R/5/12 MB No sub-feed C/B s allowed with 400 A or 600 A Type 3R/5/12. 3-, 5-, and 10-days 5- and 10-days 11

I-Line Factory-assembled Panelboards Table 27: Amps 225 A Maximum Branch Type QB, QD, QG 250 A JD, JG 600 A LC 800 A PG, PJ 1200 A PG, PJ I-Line Factory-assembled Panelboards Maximum 600 Vac Lugs and s Table 26: Base Price Lugs a Maximum Branch Lugs Amperage Type 225 A 400 A 600 A 800 A 1200 A QB 225 A QD QG $1356. $1866. $2276. 250 A JD JG 1866. 2276. $2512. 600 Ab LC 2990. 3600. 600 A LC 2456. 3056. $3968. 800 A PG PJ 3056. 3968. 1200 A PG PJ 4602. a When required, add the price of a Solid Neutral (see Table 28, Standard Solid Neutral, on page 12). b For HCP-SU panelboard only. Base Price a No. of Poles b 100 A 225 A 400 A 600 A 800 A 1000 A & 1200 A FA FH HJc JDc JGc JJc LA LH LCc LCc MGc MJc PGc PJc 2 $2100. $2100. $4956. $3956. $4146. $7126. $6132. $ 9126. 3 2418. 2958. 4710. 4440. 5550. 7466. 7196. 10666. 2 3956. 4146. 7126. 3 4440. 5550. 7466. 2 $10366. $11176. 3 11888. 12678. 2 $11846. $14778. $22542. $24336. 3 14302. 17456. 24568. 26560. 2 22542. 24336. 3 24542. 26560. a When required, add the price of a Solid Neutral ( Table 28 Standard Solid Neutral on page 10). b H- and J-frame circuit breakers will be available in I-Line panelboards in June 2005. c Standard construction back-fed main. Table 28: Standard Solid Neutral 100/225 A 400 A 600 A 800 A 1200 A $294. $384. $544. $764. $1366. 12 Table 29: Panel Type HCP-SUb I-Line 200% Rated Neutral Standard Terminal Configuration a Ampacity 800 A Type M/B MLO Branch Space Neutral Terminals Quantity & Size Type 1 Enclosure H W D Branch In mm in. mm in. mm in. mm (8) 750 kcmil 54.00 1371 (21) 350 (8) 750 kcmil kcmil (9) #14 1/0 86.00 2184 26.00 660 9.50 241 (17) #14 #4 a Available in Type 1 enclosure only; for pricing, see Table 33. b 9.00 in. (229 mm) box extension is required for HCP-SU I-Line panelboard.

I-Line Factory-assembled Panelboards Table 30: Ampere Rating a Branch s Thermal-Magnetic s 240 Vac 480 Vac 250 Vdc 3-Pole 2-Pole 1-Pole 600 Vac Space Only H 240 Vac 480 Vac 250 Vdc 600 Vac Space Only H 120 Vac 277 Vac 277 Vac 125 Vdc 15 60 A FA $ 720. $ 882.b $ 1006. $ 98. 4.50 $ 520. $ 708. (FY-1P) $ 786. $ 82. 3.00 $270.c $72. 1.50 70 100 A FA 832. 1142.b 1218. 98. 4.50 632. 956. 964. 82. 3.00 15 60 A FH 1100. 1442. 98. 4.50 1050. 1218. 98. 3.00 518.c 72. 1.50 70 100 A FH 1300. 1940. 98. 4.50 1250. 1620. 98. 3.00 15 60 A HJ 1300. 2380. 98. 4.50 2002. 98. 4.50 70 100 A HJ 1500. 2700. 98. 4.50 2364. 98. 4.50 110 150 A HJ 1500. 4500. 98. 4.50 3980. 98. 4.50 QB 1696. 98. 4.50 560. 82. 3.00 125 225 A QD 2208. 98. 4.50 1300.b 82. 3.00 QG 2870. 98. 4.50 2800. 82. 3.00 150 225 A JD 2820. 98. 4.50 2600. 98. 4.50 250 A JD 3800. 3800. 98. 4.50 3600. 3430. 98. 4.50 150 225 A JG 3780. 3990. 98. 4.50 3600. 2790. 98. 4.50 250 A JG 4000. 4180. 98. 4.50 3900. 3620. 98. 4.50 150 225 A JJ 4200. 6794.b 6110. 98. 4.50 4000. 5434. 5770. 98. 4.50 250 A JJ 4400. 8336.b 6500. 98. 4.50 4300. 6672. 6450. 98. 4.50 LA 4916. 252. 6.00 3980. 252. 6.00 300 400 A LH 5312. 252. 6.00 4500. 252. 6.00 LC 5460. 10156. 456. 7.50 450 600 A LC 10422. 456. 7.50 8920. 456. 7.50 800 A MG 10600. 446. 9.00 8180. 800 A MJ 13306. 446. 9.00 10944. 1000 1200 A PG 19966. 662. 9.00 1000 1200 A PJ 21960. 662. 9.00 a Branch circuit breaker offering does not include 25 A, 35 A and 45 A. b Ac only. c FY, FA, FH, 1-pole circuit breakers are available from 15 30 A. Space Only H Surgelogic TVSS Model IMA Surgelogic TVSS unit in I-Line plug-on construction: An integrally mounted surge protection solution that mounts onto an I-Line panelboard bus stack just like a circuit breaker. Requires 13.5 in. (343 mm) of mounting height. Table 31: Surgelogic TVSS Unit I-Line Plug-On Construction Surge Current Rating ka Voltage 100 ka 120 ka 160 ka FC FC FC 120/240 1P3W $18908. $20088. $23634. 208Y/120 3P4W 19750. 20984. 24688. 240/120 3P4W 19750. 20984. 24688. 480Y/277 3P4W 20602. 21898. 25752. 600Y/347 3P4W 13

Frequently Asked Questions Table 32: Options Surgelogic TVSS Options Surge Counter Dry Contacts Price Standard Table 33: Additional Options Option Description Additional Information Price 225 A $ 368. Sub-feed / Plug-on Lugs 400 A 2-pole or 600. 3-pole branch 800 A mounted 1490. 1200 A 1890. Equipment Ground Bar 180. Copper Ground Bar Add to Equipment Ground Bar price 148. Insulated/Isolated Ground Bar Add to Equipment Ground Bar price Price additional Neutral Assembly 100 400 A $ 868. Copper Neutral 600 A 894. Price adder 800 A 1108. 1200 A 1352. Name Plates 200% Rated Neutrals Weatherproof or Dusttight Cabinets NEMA Type 3R, 5, 12 Standard white face/black letter laminated bakelite, 1.00 in. x 3.50 in.. (25 mm x 89 mm), adhesive backing Price includes engraving 225 A 1210. 400 A Price adder per panel 1300. 800 A 2500. Maximum 26 in. (660 mm) wide box 2156. Maximum 28 in. (711 mm) wide box 3312. Maximum 42 in. (1067 mm) wide box 3312. Maximum 44 in. (1118 mm) wide box 3312. 78. Frequently Asked Questions What is Laser Service? Laser Service is a simple, quick-ship process for standard factory-assembled panelboards. What are the different delivery options available? The Laser Service has three different options for delivery: 3-day, 5-day, and 10-day. The 3-day delivery option means that the panelboard will be at the job site by the third working day; after the date the order is placed on the factory by the distributor in Q2C/EQM. The 5-day delivery option mean that the panelboard will be at the job-site by the fifth working day; after the date the order is placed on the factory by the distributor in Q2C/EQM. The 10-day delivery option means that the panelboard will be at the job-site by the tenth working day; after the date the order is placed on the factory by the distributor in Q2C/EQM. 14

Frequently Asked Questions Does this mean that the factory will air-freight the panelboard for the 5-day shipment option for the panelboard to be on the job site by the fifth working day? Not necessarily. The factory will select the best routing that meets the leadtime commitment. Via ground transportation several days before the scheduled on-site date or via air freight if the factory cannot ensure the panelboard will arrive as committed using ground transportation. What is the Laser Service panelboard product offering? The Laser Service panelboard product offering covers 100 600 A main circuit breaker / main-lugs only NQ panelboard, 100 600 A main circuit breaker/main-lugs only NF panelboard, and 225 1200 A main circuit breaker / main-lugs only I-Line panelboard. For more information on the product offerings, refer to NQ panelboards on page 6, NF panelboards on page 9, and I-Line panelboards on page 12. What if a circuit breaker that I need for my application is not covered in the Laser Service product offering? You have two options available: You can order prepared space for the circuit breaker at the time of quotation, and order the circuit breaker separately from the warehouse. Or, you can place an order for the panelboard using the standard committed delivery process. What if I require a special option with the panelboard? Most of the high volume special options, such TVSS units, 200% rated neutrals, through-feed lugs, sub-feed lugs, blank end walls, etc., have been included. If your requirement is beyond the realm of the Laser Service product offering, then order your panelboard using the standard committed delivery process. What if my customer needs the panelboard in eight days and not 10 days? Can I expedite the 10-day delivery panelboard? No, but you can place an order using the 5-day delivery option, so that the panelboard can be at your customer s location by the fifth working day. Can I do change orders on Laser Service panelboards? Change orders are allowed for Laser 10-day delivery, but not on the 3-day and 5-day delivery option. A change order is permitted up to three days after the order has been converted for a 10-day Laser. Are there any other restrictions for Laser Service panelboards? With the Laser Service, you are not allowed the following features/options: Purchase Hold for Delivery Not before dates Notepad specials and commits Instructions to Engineering What is the shipping configuration for Laser? With the Laser Service, you are allowed the following configuration: Ship together (default) option: available for 3-, 5-, and 10-day on-site delivery No box option: available for 3-, 5-, and 10-day on-site delivery Ship completely-assembled option: available for 5- and 10-day on-site delivery Box ahead option: available for 10-day on-site delivery 15

Frequently Asked Questions 16

Schneider Electric USA 252 North Tippecanoe Peru, IN 46970 USA 1-888-Square D 1-888-778-2733 www.schneider-electric.us 1600PL0701