AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

Similar documents
Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Electrical Data Supplement

Electrical Data Supplement

Electrical Data Supplement

AUXILIARY ELECTRIC HEATER KITS FOR 7.5, 10, 15 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE

Installation Instructions

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Installation Instructions

ARUF Series Multi-Position

Installation Instructions

Installation Instructions

Technical Manual. DLM Module. This manual should remain with the unit.

Owner's/Installation Manual

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Installation Instructions

installation manual imagine the possibilities Accessory Heat Kit For V-AHU VHK- A Thank you for purchasing this Samsung product.

Installation Instructions

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

INSTALLATION INSTRUCTIONS

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

TECHNICAL INFORMATION MANUAL

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Installation Instructions

Supplemental Installation Instructions -- August 2016

Supplemental Installation Instructions -- August 2016

Electrical Data Supplement

Installation Instructions For Motor Control Center (MCC) Units

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Galaxy VM. Battery Breaker Box Installation 09/

ACCESSORY KIT INSTALLATION INSTRUCTIONS

High Frequency SineWave Guardian TM

Electric. PN April Series Electric Oven

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

Installation Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

IMPORTANT ATTENTION INSTALLERS:

SERVICE INSTRUCTIONS

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

FORM NO. HSC-543 AIR HANDLERS

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Installation Instructions

GSX 16 SEER Condensing Units

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

Installation, Operation and Maintenance Manual

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

INSTALLATION INSTRUCTIONS

Installation Instructions

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

TECHNICAL MANUAL. GSC/VSC13 SEER Condensing Units with R-22

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Installation Instructions

ASPT Multi-Position Air Handler

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

AC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A.

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Owner s Information Manual

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

Installation Instructions

EXTREME R MOTOR OWNER'S MANUAL

MIL-24/2600Q MIL-24/3200DQ

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

AquaPure Ei TM Series Replacement Kits

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3, 3-Phase

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Transcription:

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400 IO-608 Houston, TN 77092 AHKD SERIES 08/02 www.goodmanmfg.com

Contents Introduction Product Description... 2 Checking Product Received... 2 Before Beginning Installation... 2 Ordering Parts... 2 Important Safety Instructions Recognize Safety Symbols, Words and Labels... Model Identification Heating kw... 4 Temperature Rise AR090 & AR20... 4 Attaching the Heat Kit... 6 Electical Connections Supply Voltage... 7 Low Voltage... 7 Single/Two-Stage Heat... 7 Wiring Diagrams AHKD5-... 8 AHKD20- & AHDK0-... 8 AHKD5-4... 9 AHKD20 & AHKD0-4... 9 Parts List... 0 Electical Supply Wire & MOP Maximum/Minimum Supply Voltage... 5 Voltage Balance... 5 MCA... 5 MOP... 6 Introduction Product Description The AHKD series of electric heat kits is an accessory designed for installation with the Goodman AR090 or AR20 Airhandler ONLY. INSTALLATIONS WITH OTHER AIRHANDLERS IS NOT PERMITTED. For installation guidelines of the AR090 or AR20, refer to the instructions which accompany the air handler, IO-227(Installation & Operating Instructions). The AHKD provides supplemental electric heat for the AR90/20. The assembly is to be installed directly to the outlet of the AR090/20 and is not to be used as an independent duct heater. The AHKD20 and AHKD0 heat kits have two stages. A two stage room thermostat determines the staging by room temperature. The heat kit s control panel is self contained and is equipped with all of the safety circuit/limits required per UL995. The heat kit employs a terminal block for installation of the high voltage wires used by both the heat kit and the airhandler (single point wiring). Checking Product Received Upon receiving the unit, inspect it for damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. Check the unit model number, specifications, electrical characteristics, and accessories to determine if they are correct. In the event an incorrect unit is shipped, it must be returned to the supplier and must NOT be installed. The manufacturer assumes no responsibility for the installation of incorrectly shipped units. Before Beginning Installation Carefully read all instructions for the installation prior to installing unit. Make sure each step or procedure is understood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally. Make sure everything needed to install AHKD Electric Resistance Heat Kits is on hand before starting. Ordering Parts When reporting shortages or damages, or ordering repair parts, give the complete unit model and serial numbers as stamped on the unit s nameplate. Order parts through your local distributor. 2

Important Safety Instructions Recognize Safety Symbols, Words, and Labels The following symbols and labels are used throughout this manual to indicate immediate or potential hazards. It is owner s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of seious personal injury or death, property damage and/or product damage. DANGER Danger - Immediate hazards which WILL result in severe personal injury or death. Warning - Hazards or unsafe practices which COULD result in severe personal injury or death. CAUTION Caution - Hazards or unsafe practices, which COULD result in minor or moderate personal injury, product damage, or property damage. Before servicing or installing this equipment, the electrical power to this unit MUST be in the OFF position. IMPORTANT NOTE: More than one disconnect may exist. Failure to observe this warning may result in an electrical shock that could cause serious personal injury or death. This installation must have an uninterrupted, unbroken electrical ground to minimize the possibility of personnel injury if an electrical fault should occur. The electrical ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box wire to the building electrical service panel. Other methods of grounding are permitted if performed in accordance with the National Electric Code (NEC)/ American National Standards Institute (ANSI)/ National Fire Protection Association (NFPA) 70 and local/state codes. In Canada, electrical grounding is to be in accordance with the Canadian Electric Code CSA C22.. Failure to observe this warning can result in electrical shock that could cause serious personal injury or death. ONLY TRAINED AND QUALIFIED PERSONNEL ARE PERMITTED TO INSTALL OR SERVICE THIS EQUIPMENT. Observe ALL warnings contained in this manual and labels/tags attached to the equipment. When installing or servicing this equipment safety clothing including hand and eye protection is strongly advised. If installing this equipment in an area that has special safety requirements (hard hats etc.) observe these requirements. Read these instructions before performing this installation or servicing this unit. All installations must be in accordance with all national, state, or local building codes.

Model Identification The electrical characteristics of the airhandler, the electric heat kit, and the building power supply must agree. Use the following table and the product s Series and Rating plate to determine the heating kw and electrical characteristics. For all supply voltages, use the correction factors in Tables 2 &, multiplied by kw and (or) temperature rise to have corrected results. Table 2. KW Correction Factors (- models) Supply Voltage 240 20 220 20 208 Correction Factor.0 0.92 0.84 0.77 0.75 Table. AHKD Model Nominal Electrical Number kw Characteristics Stages AHKD5-5 208-20//60 AHKD5-4 5 460//60 AHKD20-20 208-20//60 2 AHKD20-4 20 460//60 2 AHKD0-0 208-20//60 2 AHKD0-4 0 460//60 2 Table. KW Correction Factors (-4 models) Supply Voltage 480 460 440 45 80 Correction Factor.0 0.92 0.84 0.75 0.6 Temperature Rise The heating mode temperature rise is dependent upon the system airflow, the supply voltage, and the heat kit size (kw) selected. Use Tables 4 & 5 to determine the temperature rise ( o F): Table 4. Table 5. AR090 Temperature Rise Table (Degrees F) AR20 Temperature Rise Table (Degrees F) Airhandler AR090 Heat Kit KW 5 20 0 CFM Supply Voltage 208 240 480 2800 4 9 9 2900 4 8 8 000 8 8 00 7 7 200 2 7 7 2800 9 25 25 2900 8 24 24 000 8 24 24 00 7 2 2 200 7 22 22 2800 28 8 8 2900 27 7 7 000 27 5 5 00 26 4 4 200 25 Airhandler AR20 Heat Kit KW 5 20 0 CFM Supply Voltage 208 240 480 800 0 4 4 900 0 4 4 4000 0 400 0 4200 9 800 4 9 9 900 4 8 8 4000 8 8 400 7 7 4200 7 7 800 2 28 28 900 20 27 27 4000 20 27 27 400 9 26 26 4200 9 25 25 Note: Table 5 is calculated with both stages of electric heat engaged (2 stage heat systems). For systems using staged electric heat, divide the temperature rise from the table by 2 for st stage operation. 4

Electrical Supply Wire and MOP Before servicing or installing this equipment, the electrical power to this unit MUST be in the OFF position. IMPORTANT NOTE: More than one disconnect may exist. Failure to observe this warning may result in an electrical shock that could cause serious personal injury or death. The unit must have an uninterrupted, unbroken electrical ground to minimize the possibility of personall injury if an electrical fault should occur. The electrical ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box wire to the building electrical service panel. Other methods of grounding are permitted if performed in accordance with the National Electric Code (NEC)/ American National Standards Institute (ANSI)/ National Fire Protection Association (NFPA) 70 and local/state codes. In Canada, electrical grounding is to be in accordance with the Canadian Electric Code CSA C22.. Failure to observe this warning can result in electrical shock that could cause serious personal injury or death. To avoid the risk of fire or equipment damages use only copper conductors Inspection of the Building Electrical Service. This unit is designed for -phase operation. DO NOT OPERATE ON A SINGLE PHASE POWER SUPPLY. SEE THE ABOVE. Measure the power supply to the unit. The supply voltage MUST be in agreement with the unit nameplate power requirements and within the range shown in Table 6. Table 6. Nominal Minimum Supply Maximum Supply Voltage Voltage 208 20 87 25 460 44 506 Voltage Balance The supply voltage shall be unbalance (phase to phase) within 2%. To calculate the percentage of voltage unbalance use the following formula: Percentage Max Voltage Deviation From Avg Voltage Unbalance = 00 x Average Voltage Example. L L2 = 220 V L2 L = 26 V L L = 2 V Avg. Voltage = (220+26+2) / = 649 / = 26 Max. Deviation from Avg. = 220 26 = 4 % Voltage Unbalance = 00 x (4 / 26) = 400 / 26 =.8% Determine Wire Size The selection of the appropriate supply wire size is important to the operation of the equipment. When selecting the wire size, the following are important elements of the decision: The wire size is adequately sized to carry the Minimum Circuit Ampacity (MCA). Refer to the NEC (USA) or CSA (Canada) for wire sizing. The unit MCA for the airhandler and the optional electric heat kit can be found on the equipment S&R plate and Table 7. Table 7. AIR VOLTAGE HEAT KIT MCA AHKD5-48.6 208-20 AHKD20-6.0 AR090 AHKD0-9.9 AHKD5-4 24. 460 AHKD20-4.5 AHKD0-4 46.0 AHKD5-49.4 208-20 AHKD20-6.8 AR20 AHKD0-92.7 AHKD5-4 24.7 460 AHKD20-4.9 AHKD0-4 46.4 5

The wire size is appropriately sized to allow for no more than a 2% voltage drop from the building breaker/fuse panel to the unit. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electric Code when determining the correct wire size. Table 8 shows the current carrying capabilities for copper conductors rated at 75 o C with a 2% voltage drop. Based on NEC 996 Maximum Overcorrect Protection (MOP) Every installation must include an NEC (USA) or CEC (Canada) approved overcorrect protection device. Also check with local or state codes for any special regional requirements. This protection can be in the form of fusing or HACR style circuit breakers. The following table can be used as a guide for selecting the MAXIMUM overcurrent device. This information is also stated on the equipment S&R plate. Note: fuses or circuit breakers are to be sized larger than the equipment MCA but not to exceed the MOP listed in Table 9. Attaching the Heat Kit Table 8. Max. Allowable Length in Feet to Limit Voltage Drop to 2% Wire Size Min. Circuit Ampacity (MCA) (AWG) 0 5 20 25 0 5 40 45 4 75 50 7 NR NR NR NR NR 2 8 79 59 47 NR NR NR NR 0 88 25 95 75 6 54 NR NR 8 0 20 50 20 00 86 75 68 6 47 4 25 88 57 4 8 0 Table 9. AIR HANDLER HEAT KIT MOP AHKD5-60 AHKD20-70 AR090 AHKD0-00 AR20 AHKD5-4 0 AHKD20-4 5 AHKD0-4 50. Secure the high voltage and low voltage conduits to the heat kit electrical panel using the supplied plastic bushing nuts as shown in Figure. Figure 2. Figure. HIGH VOLTAGE WIRES LOW VOLTAGE WIRES 2. Position the heat kit onto the airhandler at the air discharge end with the control box orientated toward the airhandler front. See Figure 2. 6. Route the two electrical conduits (attached in step.) through the panel on the airhandler. Secure the conduits to the airhandler panel with the supplied plastic bushing nuts. 4. Using the supplied ½ long #0 screws, attach the heat kit to the airhandler outlet panel. Note: Open the heat kit electrical panel door to obtain access to the three screws on that side. 5. Follow the Electrical Connections section of this manual for wiring details.

Electrical Connections Supply Voltage A single point supply voltage termination is provided in the heat kit control box. Figure 4. The supply wire is to be routed through conduit from the service disconnect box to the heater kit. The heat kit is equipped with a knockout suitable for conduit. The supply voltage is to be installed on the terminal block located in the heater kit control box. Route the air handler supply voltage and ground conductors though the ½ conduit that connects the heat kit to the airhandler. Attach the supply voltage wires to the airhandler contactor and the equipment ground to the airhandler ground lug. To assist with possible troubleshooting follow the wire color conventions indicated on the wiring diagram. Figure. Single Stage Heat - Single Stage Cooling where R - Red W - White G - Green BL - Blue Note: Brown wire is not used and is to be taped. Figure 5. Two-Stage Heat - Single Stage Cooling where Low Voltage. The low voltage connection from the airhandler to the heat kit is provided through a multi-pin plug that connects to a mating plug in the airhandler. Route the heat kit low voltage harness through the ½ conduit to the airhandler control box and plug into the airhandler low voltage harness. Note: Low voltage from the room thermostat is terminated in the airhandler control box. Wiring options for the thermostat wiring are shown in the airhandler installation manual. R - Red W - White BR - Brown G - Green BL - Blue 7

L L2 L Legend FR Fan Relay FU Fuse TB Terminal Block HC Heater Contactor HTR Heater Element PLS Primary Limit Switch SLS Secondary Limit Switch L L2 L 8

L L2 L Legend FR - Fan Relay FU - Fuse TB - Terminal Block HC - Heater Contactor HTR - Heater Element PLS - Primary Limit Switch SLS - Secondary Limit Switch L L2 L 9

Repair Parts 4 5 6 2 7 8 2 ITEM PART NO. DESCRIPTION MANUFACTURER MFR. PART NO. AHKD 5-5-4 20-20-4 0-0-4 B07600 HEATER ASM. 5KW-240V-PH HEATCRAFT 04-49052-0 B0760 HEATER ASM. 20KW-240V-PH HEATCRAFT 04-49052-02 B07602 HEATER ASM. 0KW-240V-PH HEATCRAFT 04-49052-0 B0760 HEATER ASM. 5KW-480V-PH HEATCRAFT 04-49052-04 B07604 HEATER ASM. 20KW-480V-PH HEATCRAFT 04-49052-05 B07605 HEATER ASM. 0KW-480V-PH HEATCRAFT 04-49052-06 2 B608 CONTACTOR WHITE ROGERS 54-4222-5700PA PRODUCT UNLIMITED 00-0009PL FRN-R60 RELANCE FUSE ECNR-60 B70600 FUSE, 60A / 240V GOULD-SHAWMUT TR-60R 6 LITTELFUSE FLNR60 FRN-R40 6 B7060 FUSE, 40A / 240V LITTELFUSE FLNR40 JJS0 B70602 FUSE, 0A / 480V LITTELFUSE FLNR0 B7060 FUSE, 5A / 480V JJS5 LITTELFUSE JLLS5 B70604 FUSE, 50A / 480V JJS50 MARATHON JLLS50 MARATHON RF60AB B70605 FUSE BLOCK, P/60A/250V H25060-C 2 2 GOULD-SHAWMUT 20608 4 T6000-CR B70606 FUSE BLOCK, P/0A/600V MARATHON 6T0AB B70607 FUSE BLOCK, P/60A/600V B0078 MARATHON 426806 5 B68274 TERMINAL BLOCK MARATHON 42570 6220-6 B70785 RELAY AMERICAN ZETTLER AZ2280-A-24AEF(208) 7 B7098 LIMIT, MANUAL RESET 60. F. Klixon 2049L-05 2 2 2 2 8 B7099 LIMIT, AUTO RESET 40. F. Thermo-Disc 60TX-446 0

NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size of efficiency. Our designs virtually eliminate the most frequent causes of product failure. They are simple to service and forgiving to operate. We use the highest quality materials and components available because if a part fails then the unit fails. Finally, every unit is run tested before it leaves the factory. That s why we know... There s No Better Quality. Visit our website at www.goodmanmfg.com for information on: Goodman Products Warranties Customer Services Parts Contractor Programs and Training Financing Options