Power Distribution Units AP9560 & AP9561

Similar documents
Power Distribution Units

PDU Input Power Cord. Before installation. Specifications

InfraStruXure PDU Power Cable

Installation Guide. Marine Filter SURT023M SURT024M

INSTALLATION & OPERATION MANUAL

DC to DC Step Up Converter Model: VTC305

VTC610 Series Voltage Converter. Installation & Operation Manual

VTC1000 Series Voltage Converter. Installation & Operation Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

INSTALLATION & OPERATION MANUAL

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

Installation & Operation Manual PWS1000R Rack Mount Power Supply

INSTALLATION & OPERATION MANUAL

BroadBand PowerShield. 20 AHr Battery. User Manual

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Cable Ladders with Troughs and Partitions

INSTALLATION & OPERATION MANUAL VTC605 SERIES VOLTAGE CONVERTER

INSTALLATION & OPERATION MANUAL PWS1505 SERIES POWER SUPPLIES

INSTALLATION & OPERATION MANUAL VTC1505 SERIES VOLTAGE CONVERTER

WHY5690 GENERAL DESCRIPTION: WHY5690 EVALUATION BOARD for WHY5640 Temperature Controller

Broadband PowerShield. CP27U Models. User Manual

Electrical Installation

IPS1000 Series Pure-Sine Inverter

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

CTFRP Series Power Supplies

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Bottom Hose Kit for the High-Density Cooling Enclosure ARACBH1

Operation and Maintenance

Safety and General Information

NetShelter AR1000 AR1001 AR1100

AIS and 40 kva 400 V. Site Preparation and Installation Manual

User's Manual. Rack/Tower Extended Runtime Battery Packs

Installation and Operation

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

BCD600 Series Battery Charger DC. Installation & Operation Manual

ACUMENTRICS CORPORATION 1000 Watt Rugged-UPS TM with optional 24 VDC 250 Watt Output

Grid Tied Limiter User Manual

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Installation and Operation Guide

Installation Power Management Unit Battery Cables and Battery Harness

Pure Sine Wave Inverter 600W-24V User Manual

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar

Installation and Operation Guide

SPC-PANEL Simplex, Single Phase Pump Control Panel

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

INSTALLATION & OPERATION MANUAL

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range


IPS1000 INSTALLATION & OPERATION MANUAL PURE-SINE INVERTER.

Instruction Sheet. SFR Series. Swing Frame rack

APC Symmetra RM. Installation Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

Technical Specifications. Symmetra PX kw 208 V

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Users Guide for Ac-sync

BCD610 DC Source Battery Charger

ARION: 19 EIA-310E Standard Enclosure

MM-AVR UPS Series User s Manual

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors

Go to to register your product and find more information.

SUNTURA SOLAR TRACKER

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Valve Box Assembly for the High-Density Cooling Enclosure ARACVB1

SUNTURA HD SOLAR TRACKER

10 Year Limited Warranty

Stainless Steel Air Motor Conversion Kits

Power. On Your Terms.

POWER GEAR SLIDE-OUT MANUAL

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

PowerFLEX Module Limited Warranty Program

Operating Instructions for PAC800 Battery Charger

INSTALLATION, MAINTENANCE & SERVICE MANUAL

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup

UniStar II Royalton Rd. Cleveland, OH USA Voice: (440) Fax: (440) Internet:

Strap Winch Installation and Operators Instruction Manual

Stainless Steel Air Motor Conversion Kits

Type Maxi Mix III Rotary Shaker

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Pump Package Conversion Kits

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

TPAK Series COOLANT PUMP

Addendum. Remote Air-Cooled Condenser

20250 Module Installation Guide

Tank Monitor. Instruction manual DTM01. Tank Monitor

User s Manual. Complete Off-Grid Solar Kits (100 to 600 Watts) Complete Off-Grid Solar Kit Manual Revision 1.0

INSTALLATION INSTRUCTIONS

Strap Winch Installation and Operators Instruction Manual

Models P, P, P, , DANGER

OWNERS MANUAL JANUARY 2007 ISO

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Straight-Bore Clutch LSCC-32, 44, 54

User s Manual and Operating Instructions

Transcription:

Power Distribution Units AP9560 & AP9561 AP9560 and AP9561 are 30-amp Rack-mount Power Distribution Units (PDUs) that provide 120-volt or 208-volt power to rack-mount equipment. AP9560. - AP9561,, 12-foot NEMA L5-30 Power Cord - NEMA 5-20 Outlets (10). 15-amp Circuit Breakers (2). -,, 12-foot NEMA L6-30 Power Cord - IEC-320-C13 Outlets (12). 10-amp Circuit Breakers (3)

Safety and Grounding Please read the following information before installing or operating your APC Power Distribution Unit (PDU): This PDU is intended for indoor use only. Do not install this PDU where excessive moisture or heat is present. Never install any wiring, equipment, or PDUs during a lightning storm. Plug this PDU into a three-wire, grounded power outlet only. The power outlet must be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of power outlet may result in a shock hazard. Use only the supplied brackets for mounting. Do not use extension cords or adapters with this PDU. Do not work alone under hazardous conditions. Check that the power cord, plug, and socket are in good condition. To reduce the risk of electric shock when grounding cannot be verified, disconnect the PDU from the power outlet before installing or connecting equipment. Reconnect to the power outlet only after making all connections. Equipment must have a protective earth connector which carries the leakage current from the load devices (computer equipment). Do not exceed a total leakage current of 3.5 ma. Installation Horizontal Mounting (Any standard EIA-310 rack or enclosure) Attach the horizontalmounting brackets to the PDU. APC Power Distribution Units (AP9560 & AP9561) Installation Guide

Install the PDU using hardware included with your rack or enclosure. The PDU will occupy 1 U-space. Vertical Mounting (Any standard EIA-310 rack or enclosure) Attach the vertical-mounting brackets to the PDU. Install the PDU on a vertical mounting rail in your rack or enclosure.

Specifications Electrical Input voltage range AP9560: 100 120V AP9561: 200 240V Max. current draw AP9560: 24 A AP9561: 24 A Compliance Safety UL/cUL Listed; UL1950 Physical Size (h w d) Shipping size (h w d) Weight Shipping weight Environmental Elevation (above MSL) Relative Humidity Temperature 17.6 1.75 2.25in (44.7 4.45 5.72cm) 19.12 6.0 6.95in (48.6 15.2 17.65cm) 5.5lb (2.5kg) 8.0lb (3.6kg) Operating: 0 10,000ft (0 3000m) Storage: 0 50,000ft (0 15000m) Operating: 0 to 95%, non-condensing Storage: 0 to 95%, non-condensing Operating: 32 to 113 F (0 to 45 C) Storage: 13 to 149 F (-25 to 65 C) Warranty Limited warranty APC warrants the PDU to be free from defects in materials and workmanship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, APC makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction.

Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the lifesupport device or to affect significantly its safety or effectiveness. In direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. a Examples of life-support devices The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults and infants), anesthesia ventilators, infusion pumps, and any other devices designated as critical by the U.S. FDA. Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with these modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. a

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support with FAQs, knowledge base, and e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: APC headquarters U.S., Canada Latin America Europe, Middle East, Africa (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702020 (Ireland) Japan (03)5434-2021 Guidance 3 Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. 990-1202A 08/2002