Renogy MTS-TM100. Flat Roof Tilt Mount E Philadelphia St, Ontario, CA Version: 1.1

Similar documents
OUTSIDE OF VEHICLE INSIDE OF VEHICLE

Top-of-Pole Mount for 4 Modules (TPM4) For Module Types D, E, F, & G

MULTI-POLE MOUNT MULTI-POLE MOUNT. Assembly Instructions. Assembly Instructions. step-by-step assembly and installation

Top-of-Pole Mount for 6 Modules (TPM6) For Module Types A, B, & C ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

Top-of-Pole Mount for 6 Modules (TPM6) For Module Type D

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

INSTRUCTIONS INSTRUCCIONES CONSIGNES

INTRODUCTION / TABLE OF CONTENTS

Top-of-Pole Mount for 6 Modules (TPM6) For Module Types A, B, & C

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

Top-of-Pole Mount for 8 Modules (TPM8) For Module Types D, E, F, G, & H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

4' x 10' Assembly Instructions. We re Here To Help! Call Toll Free Section Roll In Dock Shown

TOYOTA TUNDRA SKID PLATE Preparation

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

202 Schwinn Recumbent Exercise Bike

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

MULTI-POLE MOUNT LARGE GROUND MOUNT. Assembly Instructions. Assembly Instructions. step-by-step assembly and installation

Top-of-Pole Mount for 2 Modules (TPM2) For Module Types C, D, E, F, G, & H

POWER RAIL TM P8. Assembly Instructions. step-by-step assembly and installation. Version 2, Rev A SP PCN

The Traveler Series TM : Adventurer

Eclipse Solar Suitcase

Top-of-Pole Mount for 12 Modules (TPM12) For Module Types D, E, F, & G When High Wind Version (HWV) or 6h x 2w, L

2 Driver/left Front/Rear Mounting Brackets 6 10mm Lock Washer 2 Passenger/right Front/Rear Mounting 6 10mm Hex Nuts

TM INSTALLATION GUIDE TM 1

INSTRUCTIONS INSTRUCCIONES CONSIGNES

Top-of-Pole Mount for 1 Module (TPM1) For Module Type H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

The Traveler Series: Wanderer

LOCKN LOAD FIRST TIME INSTALLATION

C C30120 Canopy Instructions

Hitch Receiver OEM INSTALLATION MANUAL

Multistrada (MTS) Tank Installation Notes. Tools Required. Phase 1: Remove Fairings. Phase 2: Remove Fuel Tank

PRODUCT SERVICE MANUAL

The Renogy Firefly. 20W Portable Solar System E. Philadelphia St., Ontario CA

One- Touch Installation Instructions

Top-of-Pole Mount for 15 Modules (TPM15) For Module Types E, F, & G ASSEMBLY INSTRUCTIONS

Battery Power Inverters

Duo Battery Charge Controller

RECOMMENDED SEQUENCE OF APPLICATION

WARNING NOTICE CAUTION ASSEMBLY INSTRUCTIONS

TO AVOID DOING IRREPARABLE DAMAGE TO DRIVE CIRCUITRY NEVER APPLY AC POWER DIRECTLY TO LED LIGHTBOXES!

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Camshaft Timing Chain, Sprocket, And Tensioner Replacement

PRODUCT: TJ Front Bump Stop Kit READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 7:00 AM 5:00 PM PST

INSTALLATION & OWNER S MANUAL

INSTALLATION & OWNER S MANUAL

INSTALLATION MANUAL MODEL 1200 FULL SIZE TRUCK MODEL 1205 COMPACT SIZE TRUCK

HEAVY DUTY TROLLEY JACK. Operation Manual

DeZURIK M-SERIES MANUAL ACTUATOR

INSTALLATION MANUAL ALUMINUM & STEEL SIDE BOX

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

RECOMMENDED SEQUENCE OF APPLICATION

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

TOYOTA TUNDRA SKID PLATE Preparation

INSTALLATION INSTRUCTIONS SEMI Hidden Kit Part Number: Application: Toyota Tacoma

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

panelclaw.com Polar Bear III for 10 Degree

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Top-of-Pole Mount for 12 Modules (TPM12) For Module Types D, E, F, & G

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Installation Manual for VHM-25 Series Arms Channel Mount

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

Solar collector racking system CALEFFI NAS100 series ACCREDITED Function Product range NAS100 NAS100 NAS100 NAS100

ADVANCE ADAPTERS INC. P/N: JEEP TJ & (XJ 84-01) ATLAS 4 SPEED CABLE SHIFTER units built after 5/1/12

Turning Point Pin Box. by Trailair OWNER'S MANUAL

Photovoltaic Modules Installation Manual for Australia

DR Series Radial Diaphragm Valves

PRORAC CONTRACTOR SERIES UNIVERSIAL STEEL ECONO TRUCK RACK INSTALLATION INSTRUCTIONS

Installation and Service Manual

Please read BOTH these Installation Instructions and the General Information sheet prior to installing or operating this equipment.

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

SAFETY. Your safety and the safety of others is very important.

The Traveler Series: Adventurer

AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

Toyota Hilux / fortuner BATTERY BRACKET

The Traveler Series: Wanderer

I N S T A L L A T I O N G U I D E

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

AUTO REWIND AIR HOSE REEL

RTX 2000 Thomas Compressor TG-550 Graco PN

Schletter. Solar Mounting Systems

TOYOTA HIGHLANDER RUNNING BOARD HIGHLANDER HV Preparation

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

AL625 & AL625HD INSTALLATION & OWNER S MANUAL

PRODUCT: EVAP Canister Relocation Kit: Early Model READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 7:00 AM 5:00 PM PST

INSTALLATION INSTRUCTIONS SEMI Hidden Kit Part Number: Application: 2017 Toyota 4Runner

TILT KIT - POWER RAIL P8 ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation. Version 1, Rev E SP3436 PCN

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT

REARSIGHT PART NUMBER: Code: MC1 RECOMMENDED SEQUENCE OF APPLICATION

TSS Tool Stand. Installation and Operation Manual. Document #:

Switchback Carrier Rack System

Ladder READ ME! IMPORTANT WARNING! ENG

The following information shows the steps to change the rear brake pads and rotors on an E36 chassis.

INSTRUCTIONS 360 Y-DROP

TOYOTA RAV FOG LIGHT

INTERIOR LED LIGHTING KIT

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

(31 ) ZEON CONTROL PACK RELOCATION KIT

Transcription:

Renogy MTS-TM100 Flat Roof Tilt Mount 2775 E Philadelphia St, Ontario, CA 91761 1-800-330-8678 1 Version: 1.1

Important Safety Instructions Please save these instructions. This manual contains important safety, installation, and operating instructions for the Renogy Tilt Mount hardware system. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information. WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task. CAUTION: Indicates a critical procedure for safe and proper operation of the system. NOTE: Indicates a procedure or function that is important to the safe and proper operation of the system. General Safety Information Read all of the instructions and cautions in the manual before beginning the installation. Chance to strip nuts and bolts exists. Do NOT substitute parts from other manufacture ring sources, doing so may void the warranty and/or result in an unstable system This system is NOT possess any compliance with residential structural codes and should not be used in place of a system that is, if so required by local regulations Installer Responsibilities Installation compliance with any applicable codes which are in force at the installation site Installation compliance and compatibility with all system components and the environment including but not limited to roofing, system components, etc. Verification that all project information is accurate WARNING: This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution may result in bodily injury. Protective gloves and safety glasses should be worn during installation. 2

Table of Contents General Information... 4 Compatibility... 5 Identification of Components... 5 Installation... 6 Fasten L-Joint to Back of Solar Panel... 6 Attach L-Joint to L-Bracket Foot... 8 Attach Extension Bracket to L-Joint... 9 Attach L-Bracket Foot to Extension Bracket... 10 Mounting Recommendations... 12 Dimensions... 12 3

General Information The Renogy Tilt Mount will support various mounting applications, especially in off-grid. It is suitable for most Renogy panels and can be mounted on any flat surface. This mount is designed to allow some adjustment of the panel s angle for optimum performance. The angle adjustability is dependent on the panels themselves, with bigger panel sizes decreasing angle adjustability. Key Features 5052-H32 aluminum construction Stainless steel fasteners High-tensile strength Corrosion Free Attractive brushed aluminum finish Precision hole positioning and alignment Easy, rapid assembly Angle Adjustability Note: The angles for the Renogy Tilt Mount are based off a landscape panel installation. As the solar panel size grows, the angle freedom minimizes. Note: The following angles are a general framework based on extension bracket length. The minimum angles maximizes the extension bracket length while the maximum angles minimizes the extension bracket length. Minimum Angle Maximum Angle Panel Models Minimum Angle Maximum Angle Degree Freedom 50W Mono 38 65 20 50W Poly 39 65 20 100W Mono 89 65 20 100W Poly 51 70 15 100-MB 36 64 28 150 Mono 64 77 13 250W Mono 250W Poly 270W Poly 300W Poly 64 76 12 4

Compatibility The following chart represents the Renogy Modules for which this Tilt Mount works for and is optimized for. Optimization of the module implies that there are more degrees of freedom tilting. RENOGY Solar Module RNG-10D RNG-20D RNG-30D RNG-50D RNG-100D RNG-150D RNG-250D RNG-50P RNG-100P RNG-250P RNG-300P Compatibility* INCOMPATIBLE INCOMPATIBLE INCOMPATIBLE OPTIMIZED OPTIMIZED WORKS WORKS OPTIMIZED OPTIMIZED WORKS WORKS Identification of Components Part Part Name Quantity Extension Bracket 2 L-Bracket Foot 4 L-Joint 4 Cap Bolt-55mm 4 Cap Bolt-25mm 6 5

Nut 10 Spring Washer 10 Washer 20 4mm Hex Key 1 Installation WARNING: The equipment should be installed, adjusted, and serviced by a qualified electrical maintenance personnel familiar with the construction and operation of the equipment and hazards involved. Failure to observe this precaution may result in bodily injury. Protective gloves and safety glasses should be worn during installation. CAUTION: The stripping of the threads on the nuts and bolts is possible. Recommended Tools (Not provided) Socket wrench Torque extension Box-Leveler Tape Measure 18mm wrench or socket for larger hex nut 13mm wrench or socket for smaller hex nut The above tools and equipment are highly recommended to have available to assist with installation but are in no way a comprehensive list of tools that can ease installation. Installers feel free to substitute comparable equipment where appropriate. Fasten L-Joint to Back of Solar Panel Note: All Cap Head Bolts must have a Spring Washer and Washer before feeding through a hole. A washer will also be placed after the hole before the nut. A. Place panel face down to expose mounting holes. 6

B. Slide spring washer through the threads of the 25mm Cap Bolt and then slide washer so that both make contact with the 25mm Cap Bolt s underside. C. Flush L-Joint to the back of the panel as shown in the pictures. D. Align 25mm Cap Bolt with spring washer and washer through the L-Joint base hole. Follow up by adding a washer after the hole and then use a nut to tighten into place. E. Repeat for all 4 L-Joints. Refer to the picture for correct orientation of the L-Joints. Note that the back of the L-Joints face away from the panels longitudinal center. Note: The back of the L-Joints face away from the panel s longitudinal center. 7

Attach L-Joint to L-Bracket Foot Note: The mounting angle demonstrated in the image is to serve as a guide for users and their individual assemblies. A. Flush the L-Bracket Foot onto the L-Joints. Note that the bottom of the L-Bracket Foot should face outward of the L-Joint. Also note that the 2 L-Bracket Foots will be on the same side longitudinally as seen in the image. B. Slide spring washer through the threads of the 25mm Cap Bolt and then slide washer so that both make contact with the 25mm Cap Bolt s underside. C. Adjust the panel to a desired angle for mounting D. Feed the washer and nut into the 25mm Cap Bolt 8

Attach Extension Bracket to L-Joint A. Extend the Extension Bracket to a desired length. B. Keep the extension bracket in place by using a 4mm hex key (included) to tighten the small threads down. C. Orient the Extension Bracket to be mated with the inside of the L-Joint. The T-slot on the L bracket should be facing the inside of the panel. D. Slide spring washer through the threads of the 55mm Cap Bolt and then slide washer so that both make contact with the 55mm Cap Bolt s underside. E. Insert 55mm Cap Bolt through the L-Foot and Extension Bracket and use another washer then nut; tighten accordingly F. Repeat for other side. 9

Attach L-Bracket Foot to Extension Bracket Note: The mounting angle of the Extension bracket relative to the L-Joint can change based on user needs. A. Orient the L-Foot so that it facing outwards of the Extension Bracket. B. Slide spring washer through the threads of the 55mm Cap Bolt and then slide washer so that both make contact with the 55mm Cap Bolt s underside. C. Insert 55mm Cap Bolt through the L-Foot and Extension Bracket and use another washer then nut; tighten accordingly D. Repeat for the other side. 10

11

Mounting Recommendations Note: The following information is intended to be a basic guide to give the user a basic approach to mounting. A proper roof-mounting guide should be consulted prior to beginning any installation. There are various fastening techniques, but some of the most common situations call for the use of a lag bolt. This method is common when mounting panels onto a roof with a wood or asphalt surface. The following is a basic approach and should be taken as such. 1. Find a desired mounting location 2. Drill 4 holes where the holes on the L-Bracket Feet line up. A power drill with a sufficient drill but should be utilized in this process. 3. After the hole has been drilled, silicone sealant should be administered to the hole in order to prevent leaks. 4. Use a power drill with socket extension to drill the lag bolt into the hole. 5. Drill until sufficient load is applied. Dimensions Note: The following drawings utilize inches as their dimension units. Inner Extension Bracket 12

Outer Extension Bracket L-Foot 13

L-Joint Renogy reserves the right to change the contents of this manual without notice. Revision: 9/13/2017 14