Training Proposal for Network Energy Product Technology Training Project

Similar documents
Customer Training Catalog Course Descriptions Network Energy Product Technology Training

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

PowerCube 1000 V300R005C00. Solution Description. Issue 03. Date HUAWEI TECHNOLOGIES CO., LTD.

PowerCube 1000 V300R002C01. Solution Description. Issue 02. Date HUAWEI TECHNOLOGIES CO., LTD.

Electrical Controls. Syllabus

PREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Low and medium voltage service. Power Care Customer Support Agreements

Power Conversion System The Best Technology for your photovoltaic and storage system

Two-Stroke Diesel & X-DF Engines

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

1. Abstract. 2. Introduction. 3. Pilferage and adulteration of fuels used in Telecom Sector. 4. Problems due to fuel pilferage and adulteration

UPS2000-G-(1 kva-3 kva) Quick Guide. Issue: 05 Date: HUAWEI TECHNOLOGIES CO., LTD.

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

RCDD: 16 Inst: 15 Tech: 16 Cert. Trainer: 16

Copeland Scroll Indoor Condensing Units for Refrigeration

SUBSTATION OPERATION. Maintenance Techniques. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

HWP Protection Board

General elearning Course Catalog

Automotive & Diesel Technology

Measurement made easy. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Learning paths. The path to higher performance ABB UNIVERSITY. ABB University. Learning paths

Training Program 2018 Where Education Meets Technology

PowerCube 1000 V300R002C00. Solution Description. Issue 02. Date HUAWEI TECHNOLOGIES CO., LTD.

Engine Division Training Center

ABB's Energy Efficiency and Advisory Systems

MEDSolar Training Course Module 1 Microgrids with PV support

Auto Service Technician

Crossroads Smart Grid Training Program

Hydrogen Fuel Cell UPS (Uninterruptible Power Supply)

5067 Mini BDFB / BDCBB

Saft training catalogue. Expand your knowledge & capitalise on our experience

4-Day Power System Analysis, Coordination, System Studies

Automotive Technology

Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting

RM 12V/24V Series Solar Charge Controller User s Manual

SNMP dedicated to ORVALDI Solar Infini

Key advantages of our Telecom products

DIM Heating and Air Conditioning

Motor and Generator Training

Booth #400. April 2, 2018 For Immediate Release

RECIPROCATING ROTARY PUMPS & COMPRESSORS

esure Rectifiers and NetSure DC Power Systems Krunoslav Štibi May 30thth, 2012

EUCL AMI Project Experience Share

Electrical Maintenance

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

MISSION VALLEY REGIONAL OCCUPATIONAL PROGRAM TRANSPORTATION SECTOR BASIC CAR CARE COURSE OUTLINE

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah

CHARGING SYSTEM (CS) 6 TRAINING PROGRAMS

RESILIENT SOLAR CASE STUDY: SUNY New Paltz NYPA Integrated Grid Pilot

1. SPECIFICATIONS 01-2

RIMRES: A project summary

Nuvation Low-Voltage BMS

Hybrid System. Photovoltaic Inverter kW Series. Goodwe Quality, Good Value, Good Service, GoodWe! Official website Company Wechat

Day 5 Practical and Written Final SAE Exams for SAE Int l Advanced HEV Diagnostics CoC

Caterpillar C3600 Diesel Engines Operation Maintenance & Troubleshooting

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Ballard Power Systems

HYBRID POWER FOR TELECOM SITES

Toyota Technical Training Product Matrix

Servo-pneumatic drive solution for welding guns. Top quality welding!

Industrial Lubrication. p. 93 to 97

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

RC COMPANY PROFILE

BROCHURE. End-to-end microgrid solutions From consulting and advisory services to design and implementation

Variable Frequency Drive Basics

OMAR - Power Generation AUTOMATION

Huawei Micro Grid Solar Solution

Switchgear and Distribution Systems for Engineers and Technicians

Hybrid and Electric Vehicles

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc.

Automated Driving - Object Perception at 120 KPH Chris Mansley

sun systemizer High-performance battery storage for a safe power supply

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Task By Course 7.1D This task is covered for engineers in the Leadership and Managerial Skills course

Secondary DC Distribution

THE EROAD ELD SOLUTION

Onboard DC Grid. Jan Fredrik DP Conference 2011; Houston. for enhanced DP operation in ships

Principles, Maintenance and Operation

Presentation of the European Electricity Grid Initiative

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

IBM CMM Quick Reference Guide

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

HIGH VOLTAGE vs. LOW VOLTAGE: POTENTIAL IN MILITARY SYSTEMS

BASIC PUMP TECHNOLOGY

Laboratory Scale Microgrid Test-Bed Hardware Implementation

2016 Ferrari CORSO PILOTA 1

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

Table of Contents Air Brake Tests Basic Conductor/Certification Course Basic Conductor/Mechanical (Combination Package) Basic Hazardous Materials

DPA UPScale RI kw The modular UPS for customized solutions

ABB Distribution & Transmission Protection and Control training 2010 Relay schools, application, product, and automation communications training

GUI Customization with Abaqus. Abaqus 2017

SIRIUS A Drive-by-Wire University Project. Per Johannessen Chalmers University of Technology Volvo Car Corporation

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

In any of the 5 star hotels. The exact venue will be informed once finalized.

Low Speed Engine Room W-Xpert W-X72 Simulator

Transcription:

Training Proposal Training Proposal for Network Energy Product Technology Training Project HUAWEI Learning Service 2015 COMMERCIAL IN CONFIDENCE 1

Training Proposal CONTENTS 1 Training Solution... 3 1.1 Required Training Programs... 3 1.2 Telecom Energy... 4 1.2.1 Minishelter(ITS1000M) System Operation and Maintenance Training... 4 1.2.2 Power 3000 (DC Power) System Operation and Maintenance Training... 6 1.2.3 Power 3000 (DC Power) System Design Training... 8 1.2.4 PowerCube 1000 System Operation and Maintenance Training... 9 1.2.5 PowerCube1000 System Design Training... 11 1.3 Data Center Energy... 12 1.3.1 UPS2000 Operation and Maintenance Training... 12 1.3.2 UPS5000 Operation and Maintenance Training... 14 1.3.3 UPS8000 Operation and Maintenance Training... 16 1.3.4 IDS1000 System Operation and Maintenance Training... 18 1.3.5 IDS2000 System Operation and Maintenance Training... 20 1.3.6 NetEco System Operation and Maintenance Training... 22 1.3.7 NetCol5000 System Operation and Maintenance Training... 24 1.3.8 NetCol8000 System Operation and Maintenance Training... 26 COMMERCIAL IN CONFIDENCE 2

1 Training Solution 1.1 Required Training Programs Network Energy Product Technology Training For this project, the whole training solution is designed into the following programs. List of Training Program(s) for Network Energy Product Technology Training Project: Training Program Program Level Duration (workdays) Training Location Class Size Telecom Energy Minishelter(ITS1000M) System Operation and Maintenance Training Power 3000 (DC Power) System Operation and Maintenance Training Ⅱ 2 6 ~ 12 Ⅱ 4 6 ~ 12 Power 3000 (DC Power) System Design Training Ⅲ 2 6 ~ 12 PowerCube 1000 System Operation and Maintenance Training Ⅱ 4 6 ~ 12 PowerCube1000 System Design Training Ⅲ 2 6 ~ 12 Data Center Energy UPS2000 Operation and Maintenance Training Ⅱ 2 6 ~ 12 UPS5000 Operation and Maintenance Training Ⅱ 3 6 ~ 12 UPS8000 Operation and Maintenance Training Ⅱ 4 6 ~ 12 IDS1000 System Operation and Maintenance Training Ⅱ 5 6 ~ 12 IDS2000 System Operation and Maintenance Training Ⅱ 5 6 ~ 12 NetEco System Operation and Maintenance Training Ⅱ 1 6 ~ 12 NetCol5000 System Operation and Maintenance Training NetCol8000 System Operation and Maintenance Training Ⅱ 2 6 ~ 12 Ⅱ 2 6 ~ 12 Level Description:Ⅰ: Basic Course Ⅱ: Intermediate Course Ⅲ: Advanced Course Ⅳ: Expert Course COMMERCIAL IN CONFIDENCE 3

1.2 Telecom Energy 1.2.1 Minishelter(ITS1000M) System Operation and Maintenance Training Training Path Minishelter(ITS1000M) System Operation and Maintenance Training OPA02 Lecture + Practical 2d Target Audience The program is intended for field maintenance engineers, second line or technical support engineers of Minishelter (ITS1000M) System Operation and Maintenance Prerequisites Having working experience in engineering project or maintenance of Minishelter (ITS1000M) or be familiar with Minishelter(ITS1000M) group Objectives On completion of this program, the participants will be able to: Outline green site solution of Minishelter(ITS1000M) system. Interpret the working principle of Minishelter(ITS1000M) system. Interpret the basic structure of Minishelter(ITS1000M) system. Outline the typical configurations of Minishelter(ITS1000M) Interpret the functions and specifications of different parts. Perform hardware configuration and cables connection. Perform the installation of Minishelter(ITS1000M) system. Perform the operation of Minishelter(ITS1000M) system. Perform the maintenance of Minishelter(ITS1000M) system. Explain the common fault types. Apply fault disposal method Explain how to prevent the fault Locate and eliminate faults, get experience from troubleshooting practice Training Content OPA02 Minishelter(ITS1000M) System Operation and Maintenance Training Minishelter (ITS1000M) Solution Description Challenges of traditional shelter Mini-shelter leads a new era of green sites Telecom grade design, create reliable site Mini-shelter reduces TCO Minishelter (ITS1000M) System Operation and Maintenance Overview of Minishelter(ITS1000M). COMMERCIAL IN CONFIDENCE 4

Hardware Architecture of Minishelter(ITS1000M). Hardware Configuration of Minishelter(ITS1000M). Application Scenarios of Minishelter(ITS1000M). Introduction to Installation of Minishelter(ITS1000M). Routine Maintenance Troubleshooting Minishelter (ITS1000M) User Guide Minishelter (ITS1000M) User Guide Duration 2 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 5

1.2.2 Power 3000 (DC Power) System Operation and Maintenance Training Training Path Power 3000 (DC Power) System Operation and Maintenance Training OPB12 Lecture + Practical 4d Target Audience The program is intended for second line or technical support engineers of Power 3000 (DC Power) Operation and Maintenance Prerequisites Having working experience in the maintenance of Power System more than one year and Be familiar with Battery group Objectives On completion of this program, the participants will be able to: Describe the working principle of power system Describe structure, functions of power system Outline the features of power system. Outline composing of power system Interpret the functions and specifications of different composing. Outline the load capacity and ability of power system. Perform DC power system operation and maintenance, etc. Perform the on-site operation, such as AC detective-board replacement, etc. Locate and eliminate faults, get experience from troubleshooting practice Training Content OPB12 Power 3000 (DC Power) System Operation and Maintenance Training Basic Explainledge of power distribution Application scenario of power distribution Power distribution used in different power solution Basic conception of power distribution Low-voltage electrical devices Power distribution product introduction Power3000 operation and maintenance Routine maintenance of power3000 Troubleshooting procedure of power3000 Type troubleshooting of power3000 How to troubleshooting the common faults How to replacing main components Power3000(DC Power) User Guide COMMERCIAL IN CONFIDENCE 6

Duration Power3000(DC Power) User Guide 4 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 7

1.2.3 Power 3000 (DC Power) System Design Training Training Path Power 3000 (DC Power) System Design Training OPB18 Lecture 2d Target Audience The program is intended for layout and design engineer of Power 3000 (DC Power) solution, or senior engineer of operation and maintenance Prerequisites Having working experience in technical support of Power 3000 (DC Power) more than three years and Having more than three years working experience in battery and power distribution Objectives On completion of this program, the participants will be able to: Explain the design principle of Power 3000 (DC Power) solution. Outline the design step of Power 3000 (DC Power) solution. Perform power consumption calculation Perform battery configuration design of Power 3000 (DC Power) solution. Perform the design process, design methods of Power 3000 (DC Power) solution Training Content OPB18 Power 3000 (DC Power) System Design Training Duration Power 3000 (DC Power) System Design 2 working days Class Size Min 6, Max 12 Overview of DC Power Design Method Design procedure of DC Power system Calculate power consumption Configure battery capacity and string Configure PSU Configure circuit breaker Configure power cable and grounding cable Configure diesel generator COMMERCIAL IN CONFIDENCE 8

1.2.4 PowerCube 1000 System Operation and Maintenance Training Training Path PowerCube 1000 System Operation and Maintenance Training OPC52 Lecture + Practical 4d Target Audience The program is intended for second line or technical support engineers of PowerCube 1000 Operation and Maintenance Prerequisites Having working experience in the operation and maintenance of D.G more than one year and Be familiar with Battery group Objectives On completion of this program, the participants will be able to: Outline different type scenario of PowerCube 1000 Solution. Outline the load capacity and ability of PowerCube 1000 Solution. Interpret the working principle of PowerCube 1000 Solution. Interpret the basic structure of PowerCube 1000 Solution. Outline the typical configurations of PowerCube 1000 Solution. Interpret the functions and specifications of different parts. Perform hardware configuration and cables connection. Perform the installation of PowerCube 1000 Solution. Perform the operation of PowerCube 1000 Solution. Perform the maintenance of PowerCube 1000 Solution. Explain the common fault types. Apply fault disposal method Explain how to prevent the fault Perform the Field operation, such as Battery replacement. Locate and eliminate faults, get experience from troubleshooting practice Training Content OPC52 PowerCube 1000 System Operation and Maintenance Training PowerCube 1000 Solution Description Solution background System introduction Highlights and benefits PowerCube 1000 Operation and maintenance PowerCube 1000 System introduction Component of PowerCube 1000 introduction COMMERCIAL IN CONFIDENCE 9

Installation Devices Installation Cables Power on and Commissioning Routine maintenance General Procedures of maintenance General Procedures of Troubleshooting Methods of Fault Judgment and Location Troubleshooting PowerCube 1000 User Guide PowerCube 1000 User Guide Duration 4 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 10

1.2.5 PowerCube1000 System Design Training Training Path PowerCube1000 System Design Training OPC58 Lecture 2d Target Audience The program is intended for layout and design engineer of PowerCube1000 solution Prerequisites Having more than three years working experience in technical support of hybrid power solution Having more than three years working experience in battery and power system design Objectives On completion of this program, the participants will be able to: Explain the design principle of PowerCube1000 solution. Outline the design step of PowerCube1000 solution.solution. Perform solar module and battery configuration design of PowerCube1000 solution. Perform D.G. configuration design Perform power system configuration design Perform the design process, design methods of PowerCube1000 solution. Training Content OPC58 PowerCube1000 System Design Training PowerCube1000 System Design Overview of PowerCube1000 Design Method Design progress of PowerCube1000 PV Panels Configuration Desiign D.G Configuration Design Battery Configuration Design Power System Configuration Design Duration 2 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 11

1.3 Data Center Energy 1.3.1 UPS2000 Operation and Maintenance Training Training Path UPS2000 Operation and Maintenance Training OPD12 Lecture + Practical 2d Target Audience The program is intended for second line or technical support engineers of UPS Operation and Maintenance Prerequisites Having working experience in the maintenance of UPS more than one year and Be familiar with Battery group Objectives On completion of this program, the participants will be able to: Describe the working principle and main components of UPS Express the function and features of main components of UPS2000 Describe the load capacity of UPS2000 Perform installation and maintenance of UPS2000 Locate and eliminate faults, get experience from troubleshooting practice Training Content OPD12 UPS2000 Operation and Maintenance Training UPS2000 System Description UPS working priciple UPS2000 components introduction UPS2000 classification and features UPS2000 technology features UPS2000 application scenario UPS2000 System Operation and maintenance UPS2000 routine maintenance UPS2000 typical faults UPS2000 modules replacement UPS2000 procedure of troubleshooting Judgment and Location troubleshooting of UPS2000 UPS2000 User Guide UPS2000 User Guide COMMERCIAL IN CONFIDENCE 12

Duration 2 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 13

1.3.2 UPS5000 Operation and Maintenance Training Training Path UPS5000 Operation and Maintenance Training OPD22 Lecture + Practical 3d Target Audience The program is intended for second line or technical support engineers of UPS Operation and Maintenance Prerequisites Having working experience in the maintenance of UPS more than two years and Be familiar with Battery group Objectives On completion of this program, the participants will be able to: Describe the working principle and main components of UPS Express the function and features of main components of UPS5000 Express the typical configuration of UPS5000 Express the classification and model of UPS5000 Describe the load capacity of UPS5000 Perform installation and maintenance of UPS5000 Locate and eliminate faults, get experience from troubleshooting practice Training Content OPD22 UPS5000 Operation and Maintenance Training UPS5000 System Description UPS working priciple UPS5000 components introduction UPS5000 classification and features UPS5000 technology features UPS5000 application scenario UPS5000System Operation and maintenance UPS5000 routine maintenance UPS5000 typical faults UPS5000 modules replacement UPS5000 procedure of troubleshooting Judgment and Location troubleshooting of UPS5000 UPS5000 User Guide UPS5000 User Guide COMMERCIAL IN CONFIDENCE 14

Duration 3 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 15

1.3.3 UPS8000 Operation and Maintenance Training Training Path UPS8000 Operation and Maintenance Training OPD32 Lecture + Practical 4d Target Audience The program is intended for second line or technical support engineers of UPS Operation and Maintenance Prerequisites Having working experience in the maintenance of UPS more than three years and Be familiar with Battery group Objectives On completion of this program, the participants will be able to: Describe the working principle and main components of UPS Express the function and features of main components of UPS8000 Express the method of combine UPS8000 Express the typical configuration of UPS8000 Express the classification and model of UPS8000 Describe the load capacity of UPS8000 Perform installation and maintenance of UPS8000 Locate and eliminate faults, get experience from troubleshooting practice Training Content OPD32 UPS8000 Operation and Maintenance Training UPS8000 System Description UPS working priciple UPS8000 components introduction UPS8000 classification and features UPS8000 technology features UPS8000 application scenario UPS8000System Operation and maintenance UPS8000 routine maintenance UPS8000 typical faults UPS8000 modules replacement UPS8000 procedure of troubleshooting Judgment and Location troubleshooting of UPS8000 UPS8000 User Guide UPS8000 User Guide COMMERCIAL IN CONFIDENCE 16

Duration 4 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 17

1.3.4 IDS1000 System Operation and Maintenance Training Training Path IDS1000 System Operation and Maintenance Training OPE12 Lecture + Practical 5d Target Audience The program is intended for second line or technical support engineers of IDS1000 System Operation and Maintenance Prerequisites Having working experience in the maintenance of IDS1000 and Power System Objectives On completion of this program, the participants will be able to: Describe the basic structure of IDS1000 system. Describe the operation of IDS1000 system. Describe the working principle, structure, functions and features of IDS1000 system. Explain the functions and specifications of different parts. Locate and eliminate faults, get experience from troubleshooting Training Content OPE12 IDS1000 System Operation and Maintenance Training Duration IDS1000 Solution Description Challenge of traditional data center Benefit of IDS1000 IDS1000 subsystem IDS1000 system introduction Function and Features Application Scenario Successful Cases IDS1000System Operation and maintenance Maintenance procedure and caution of IDS1000 IDS1000 routine maintenance Judgment and Location troubleshooting of ventilation system of IDS1000 Subsystem troubleshooting IDS1000 User Guide 5 working days IDS1000 User Guide COMMERCIAL IN CONFIDENCE 18

Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 19

1.3.5 IDS2000 System Operation and Maintenance Training Training Path IDS2000 System Operation and Maintenance Training OPE22 Lecture + Practical 5d Target Audience The program is intended for second line or technical support engineers of IDS2000 System Operation and Maintenance Prerequisites Having working experience in the maintenance of Data Center Objectives On completion of this program, the participants will be able to: Outline the subsystem of IDS2000 Outline the main components of IDS2000 Outline the function and features of cooling system and power system Perform operation and maintenance of UPS and DC power system Perform operation and maintenance of air conditioner and PDF Locate and eliminate faults, get experience from troubleshooting Training Content OPE22 IDS2000 System Operation and Maintenance Training IDS2000 Solution Description Challenge of traditional data center Benefit of IDS2000 Modularize data center Function and Features of modularize data center Function and Features of modularize data center Application Scenario Successful Cases IDS2000System Operation and maintenance Maintenance procedure and caution of IDS1000 IDS1000 routine maintenance Cooling system and power system troubleshooting Judgment and Location troubleshooting of subsystem IDS2000 User Guide IDS2000 User Guide COMMERCIAL IN CONFIDENCE 20

Duration 5 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 21

1.3.6 NetEco System Operation and Maintenance Training Training Path NetEco System Operation and Maintenance Training OPF02 Lecture + Practical 1d Target Audience The program is intended for staffs that are responsible for network element monitoring and operation through imanager NetEco. Typical target group would be NMS operator Prerequisites Having basic Describeing of data communication Having general Explainledge of telecom networks Accomplish the corresponding product training, which is managed by imanager NetEco Objectives On completion of this program, the participants will be able to: Express the working principle of monitoring equipments, such as DG control unit, Water Level Sensor, door sensor Describe the classification, specification and features of monitoring equipments Become familiar with the basic concepts, structures and operations about system. Describe system structure, orientation features, network application and functions of the imanager NetEco. Describe the features of topology management, security management, configuration management, alarm management and performance management of imanager NetEco. Perform network performance monitoring, network alarms monitoring, environment and power supply monitoring and network element data backup and upgrading Training Content OPF02 NetEco System Operation and Maintenance Training NetEco Product Introduction Network management architecture Hardware and software architecture of imanager NetEco Features of imanager NetEco Describe the interfaces Provided by NetEco Successful cases NetEco Operation and maintenance Login to the Server via Client Add a map and device Deal with the alarm Backup and auto save the configuration COMMERCIAL IN CONFIDENCE 22

Duration Add a management user The function, structure and protocol stack of SNMP protocol. The basic concepts, working theories, structures and operations abou operation system. The features of topology management, security management, configuration management, alarm management and performance management of imanager NetEco. The operation for service provisioning and maintenance, element management, alarm management and performance statistics 1 working day Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 23

1.3.7 NetCol5000 System Operation and Maintenance Training Training Path NetCol5000 System Operation and Maintenance Training OPG22 Lecture + Practical 2d Target Audience The program is intended for second line or technical support engineers of NetCol5000 System Operation and Maintenance. Prerequisites Describe elementary electrical circuit and refrigeration theory Graduator of junior college or higher More than one year of previous experience of similar position Objectives On completion of this program, the participants will be able to: Describe refrigeration theory Describe principle of compressor, condenser, evaporator, humidifiers, re-heater, and kinds of sensors Design solution of air-conditioner Apply solution of air-conditioner Install Huawei air-conditioner Operate air-conditioner Fill in new air-conditioner starting and testing records Use the special tools and meters Do daily maintenance Troubleshoot air-conditioner Fill in maintenance and testing records Training Content OPG22 NetCol5000 System Operation and Maintenance Training IDS2000 Solution Description Challenge of traditional data center Benefit of IDS2000 Modularize data center Function and Features of modularize data center Function and Features of modularize data center Application Scenario Successful Cases IDS2000System Operation and maintenance COMMERCIAL IN CONFIDENCE 24

Maintenance procedure and caution of IDS1000 IDS1000 routine maintenance Cooling system and power system troubleshooting Judgment and Location troubleshooting of subsystem IDS2000 User Guide IDS2000 User Guide Duration 2 working days Class Size Min 6, Max 12 COMMERCIAL IN CONFIDENCE 25

1.3.8 NetCol8000 System Operation and Maintenance Training Training Path NetCol8000 System Operation and Maintenance Training OPH02 Lecture + Practical 2d Target Audience The program is intended for second line or technical support engineers of NetCol8000 System Operation and Maintenance. Prerequisites Having basic Explainledge about ventilation and A/C system. Objectives On completion of this program, the participants will be able to: Describe the air conditioner working principle, especially for the refrigeration theory Describe the working principle of compressor, condenser, evaporator, humidifiers, re-heater, and kinds of sensors Describe the NetCol8000 solution of air-conditioner Apply NetCol8000 solution of air-conditioner Explain the application scenario of NetCol8000 system Operate the naming rule of NetCol8000 system Describe the basic structure and typical layout of NetCol8000 system. Operate the components specification and features Operate the function of compressor, condenser, evaporator and so on Perform the partially filling in refrigerant Perform commissioning Perform checking after commissioning Perform the air filter, indoor fan, compressor, condenser, evaporator, Infrared Humidifier, electric heater, air suction and exhaust pressure, sight glass, electrical control system, routine maintenance Perform common fault troubleshooting Perform fault diagnosis and troubleshooting Training Content OPH02 NetCol8000 System Operation and Maintenance Training NetEco Product Introduction Network management architecture Hardware and software architecture of imanager NetEco Features of imanager NetEco Describe the interfaces Provided by NetEco COMMERCIAL IN CONFIDENCE 26

Duration Successful cases NetEco Operation and maintenance 2 working days Class Size Min 6, Max 12 Login to the Server via Client Add a map and device Deal with the alarm Backup and auto save the configuration Add a management user The function, structure and protocol stack of SNMP protocol. The basic concepts, working theories, structures and operations abou operation system. The features of topology management, security management, configuration management, alarm management and performance management of imanager NetEco. The operation for service provisioning and maintenance, element management, alarm management and performance statistics COMMERCIAL IN CONFIDENCE 27

COMMERCIAL IN CONFIDENCE 28