GLYCOL SYSTEM MONITOR (GSM)

Similar documents
TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Thermaltake Warranty / Support Information

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

Reference Manual FM-200 Series

Submersible Waterfall Pump 1200 Gallons Per Hour

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

PVI 60KW, PVI 82KW, PVI 95KW

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Parts Manual Vermeer/ McLaughlin Mud System 230P

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

Straight-Bore Clutch LSCC-32, 44, 54

Pressurized Pond Filter Up to 850 gallons

Parts Manual Vermeer/ McLaughlin Mud System 230P

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

II DISTRIBUTION & SUBSTATION TYPE C

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Premium Pond Pump 330 Gallons Per Hour

2017 Price List 2018 Price List

FCB-450, LCB-600, MCB-800

CW Optimizer Capacity Hat Kit. 75/80 and 80/40 Thunderbolt Vertical Antennas. for the DXE-7580-THK

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

WARNING. Introduction ! ATTENTION

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Fifth Wheel Power Hitch Operations Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

Cleaning & Sanitizing Instructions

Operating and Installation Instructions

Installation Instructions

WARRANTY POLICY FOR LD SERIES LABEL DISPENSERS REPAIR POLICY

Premium Waterfall Pump 1200 Gallons Per Hour

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Operating Manual Safety Level II

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

StormPro BA Series Sump Pump

Submersible Pond Pump with UV 800 Gallons Per Hour

20250 Module Installation Guide

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

Do not install and/or operate this safety product unless you have read and understand the safety information contained

DAP-625S and DAP-875S

INW Panel Meter Reading an INW PT12 Sensor

Complete Raised Rail Roof Rack System SR1098 SR1099

S8JX-N/S8JX-G Series Replacement Brackets

HR-20P Pneumatically Controlled Pressure Regulator

Instruction Manual. Backup Sensor Reversing System RVS-RS103

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Series 2100 Operating Instructions

TBM Series 3-Way Ball Valve

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Illumifalls Patio Pond

LIFT NAME PART NUMBER SETBACK (min) SETBACK (max)

Female Plug. connecting to Fuel Quantity

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

StormPro BCV400 Sewage Ejector Pump

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

30100 Module Installation Guide L

Broadband PowerShield. CP27U Models. User Manual

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

P/N# Performance Lowering Springs Installation Instructions

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Firstmate Installation Manual and User's Guide May, 2003

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Operating Manual DSJ40T-P Double Stack Jack

OWNERS MANUAL HF4263

MODEL V-24 OWNER'S MANUAL PARTS

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Natural Fiber Planter Fountain

JDCR2000 Module Installation Guide

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

ECLIPSE Laundry Dispenser Controller

Instructions and Parts List 3M-Matic P/N Infeed/Exit Conveyor Attachment, 1.2 Meter

2015 & 2018 Fender Brace Installation Instructions

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Users Guide for Ac-sync

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

BP1204 INSTALLATION/OWNER'S MANUAL

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Transcription:

GLYCOL SYSTEM MONITOR (GSM) The Future of Beer System Diagnostics Glycol cooling systems are typically overlooked by most resturaunts. However, when the unit(s) are performing poorly or there is a component failure, it leads to product waste and lost profits! Custom Beverage Service s is designed to alert the operator of issues with their glycol cooling system, before product is wasted or damage to the system occurs. In a situation where the glycol cooling equipment is located out of sight (on the roof of a cooler or buried in a basement, etc). The allows for remote display in a high traffic area of the restaurant, where the operator can see and hear when an alarm is activated. How does the work? Custom Beverage Service s reads the temperature of the glycol, indicates the flow from the recirculating pump, and high bath fluid level. The GSM has been designed as a cut & clamp installation, the only electrical connections to be made are the quick connect cords to their components and the control box. All the sensors and switches are 3/8 barbed connections ready to be installed in-line on the beer system. Temperature Monitoring: The GSM is equipped with an in-line temperature sensor that displays the current glycol temperature on the control box. There are both high and low temp audible/visual alarms on the control box. If the glycol reads outside the preset temperature parameters (either high or low) the appropriate alarm will activate, alerting the operator to call for service. Recirculating Pump Monitoring: The GSM is equipped with in-line flow switch(es) that will activate an audible/visual alarm if the pump is not moving fluid, alerting the operator to call for service before the system becomes inoperable. This alarm will also alert the operator to something as simple as the pump cord having been unplugged, which can be resolved by the operator without placing a service call. Liquid Level Monitoring: The GSM has the option of a liquid level switch (for units with overflow fittings). When the glycol in a unit becomes weak ice will form on the evaporator, as this ice builds, it will raise the fluid level until it leaks from the overflow fitting. The liquid level switch will activate an audible/visual alarm on the control box, notifying the operator to call for service. Please contact Don Jaillet with any questions or concerns: don@mabeer.com

GLYCOL SYSTEM MONITOR (GSM) ORDERING A : Custom Beverage Service s has several package configurations to service a wide variety of glycol units on the market today. What Custom Beverage Service s needs to know for your build: Make and Model of the glycol unit? How many recirculating pumps are on the unit? Do you require the High Liquid Level switch? How far away from the glycol unit are you mounting the control box? (Component cords available in 8 & 24 standard lengths) Does the system have Ice Frosted towers? Control Box Placement: The control box should be mounted in a back-of-house area, regularly traveled by restaurant staff during the day. Having the control box mounted where restaurant staff can see and hear the alarms is essential, however care should be taken to place the control box in an area where it will be free from physical damage. ENCLOSURE MATERIAL: ABS Plastic ELECTRICAL REQUIREMENTS: 120v /15a AUDIBLE ALARM: 80db @ 10cm DIMENSIONAL INFORMATION: 10.5 x 8.5 x 5.75

Configured for single pump operation GSM-2P-1215-001 #ME-001 C-24 #CC-1-24 #ME-001 Pump Flow Sensor #CC-1-24 Component Cord *

Configured for dual pump operation GSM-2P-1215-002 #ME-002 C-24 #CC-2-24 #ME-002 Pump Flow Sensor x2 #CC-2-24 Component Cord *

Custom Beverage Services Configured for single pump and high liquid level switch operation GSM-2P-1215-LL1 #ME-LL1 C-24 #CC-2-24 #ME-LL1 Pump Flow Sensor #CC-2-24 Component Cord * Liquid Level Switch

Custom Beverage Services Configured for dual pump and high liquid level switch operation GSM-2P-1215-LL2 #ME-LL2 C-24 #CC-3-24 #ME-LL2 Pump Flow Sensor x2 #CC-3-24 Component Cord * Liquid Level Switch

Warranty Policy Custom Beverage Services Products Warranty Policy Custom Beverage Services warrants components for 12 months from the invoice date. Damage due to water, physical abuse, high voltage (incorrect wiring or lightening), improper installation or other factors beyond the control of Custom Beverage Services will void the components warranty. Repair & Return If the defective component is still under Custom Beverage Services 12 month warranty, Custom Beverage Services will repair or replace the component at no cost to you. You will need to return the defective part to Custom Beverage Services, if a returned part is deemed damaged due to misuse or misapplication (water, physical abuse, high voltage etc.) you will have the option of having the part returned to you at your cost. If the defective or damaged component is no longer covered under Custom Beverage Services warranty, Custom Beverage Services will ask you for a form of payment (PO number, Credit Card, etc.) to cover the repair and shipping charges. You will be charged for the time, materials and shipping costs necessary to repair or replace the part. The returned part will have a (90) day repair warranty. Custom Beverage Services will not at any time be responsible for product installation cost. WARRANTY The warranty extended by Custom Beverage Services, as printed below, is a limited warranty to provide parts and factory labor necessary to remedy any material defects which appear during the first twelve months from date of invoice of a Custom Beverage Services product. This warranty is subject to proper system installation and maintenance, as specified by Custom Beverage Services, and does not cover willful or accidental damage. Custom Beverage Services (Seller) warrants to the buyer of this Custom Beverage Services product (Buyer), that all tangible articles manufactured by Seller will be free of material defects in workmanship and material. Seller s sole obligation under this warranty shall be to provide, without charge, parts and factory labor necessary to remedy material defects, if any, which appear during the first twelve months from the date of invoice of such articles right to require Seller to repair or replace components, and any claim must be made to Seller in writing within twelve months after such invoice date. This warranty is the sole and exclusive warranty given with respect to any articles delivered by Seller AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SELLER IS NOT RESPONSIBLE FOR LOSS OF PROFITS, ECONOMIC LOSS OR OTHER INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty is subject to installation and maintenance of the articles in accordance with the specifications and directions supplied by Seller. To obtain warranty service the articles must be shipped or delivered to Seller. All postage, insurance and shipping charges including import duties and taxes are the responsibility of the Buyer. Seller makes no warranty whatsoever with respect to articles which are not manufactured by it; however, Seller will assign or make available to Buyer any warranty which has been extended or assigned to Seller by the manufacturer and/or vendor of such articles and which Seller has the right to so assign or otherwise make available to Buyer. Acceptance of articles covered hereby by Buyer from the carrier on shipment thereof shall constitute a waiver of all claims based on delay in delivery; and every claim on account of breakage, short count, or any defect ascertainable upon receipt by Buyer shall be waived by Buyer, unless made in writing within fifteen (15) days after the receipt of the articles to which the claim relates. Buyer s exclusive remedy and Seller s entire liability in contract, tort, or otherwise for breach of this warranty is Buyer s.