Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Similar documents
Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Ceiling swirl diffusers with perforated face plate

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Ceiling swirl diffusers

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

KLIMA Active Chilled Beams

Active Chilled Beams

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Active Chilled Beams

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Slot diffusers for ceiling installation

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Ceiling induction diffuser DISA-601

Type VSD35. Nominal length up to 1500 mm: one spigot

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Ceiling induction diffuser DISA-300

Parts and characteristics

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type Pneumatic actuators

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Slot diffusers, Round duct diffusers. IMP Klima

For installation into ductwork

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Induction terminal units

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Air Displacement Vent Units

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CornerAir. CornerAir. Active chilled beam

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

LindabPodium. Supply air beam. lindab we simplify construction

Total comfort control

VARYCONTROL VAV Dual Duct Terminal Boxes

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

TYPE EK-EU SMOKE CONTROL DAMPER

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Volume Flow Limiters Type VFL

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

ceiling swirl diffuser DQJ

Floor Swirls Models BZD and SZD

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Displacement flow diffusers. L e

Pressure relief dampers

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

AIR-TWIST - ACTIVE CHILLED BEAM SUSTAINABLE AND AESTHETIC. - Patent Pending -

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Duct Nozzle Diffuser. L e

CBQ Multiservice chilled beam platform for suspended installation

Swegon PACIFIC. Integrated climate beam

Ventiduct nozzle ducts

Multileaf damper with actuator

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Halton Rex 600 RE6 - Adaptable active chilled beam

Type NAK. Gas-tight shut-off damper with pneumatic actuator

series 90-GV Variable geometry units

Ventiduct nozzle ducts

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Use. Installation. Key figures. Worth noting. linx industries chilled beams

CAV controllers Type RN

BRC

Ceiling impulse diffuser Model PIL

WGA Long throw nozzle grille

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Ceiling diffuser 4DE

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

for suspended installation. Active climate beam with cooling, heating and ventilation

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Ceiling Slot Diffuser Model DSX

Transcription:

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL HEAT EXCHANGER Active chilled beam for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for freely suspended installation; additional functions or services (e.g. lighting, loudspeakers, sprinklers, smoke detectors, or PIR sensors) can be integrated Preferably for room heights up to 4.00 m High heating and cooling capacity with a low conditioned primary air volume flow rate and low sound power level High comfort levels as a result of low airflow velocities in the occupied zone Unit consists of three parts: wall end, active section, and front end Four nozzle variants to optimise induction based on demand Optional equipment and accessories Control system 3 different front ends Various services, e.g. lighting, sprinklers, smoke detectors, PIR sensors, and loudspeakers Powder coating in many different colours, e.g. RAL CLASSIC

APPLICATION Application Active chilled beams of Type DID-SB (SMART BEAM) for freely suspended installation, preferably for room heights up to 4.00 m Project-specific integration of functions or services such as lighting, loudspeakers, sprinklers, smoke detectors, or PIR sensors Integral strip light fittings use innovative microprism optics to provide uniform illumination of rooms Each section can be individually designed 2-pipe or 4-pipe heat exchangers enable good comfort levels with a low conditioned primary air volume flow rate Energy-efficient solution since water is used for heating and cooling Special characteristics Freely suspended active chilled beam with choice of different face plate perforations Heat exchanger as 2-pipe or 4-pipe system Wide range of additional services such as lighting, sprinklers, loudspeakers and sensors (accessories) Water connections at the narrow side, Ø12 mm Cu pipe, with plain tails or with G½" external thread, or with a G½" union nut; with flat seal Wall end Cover for air and water connections at the end facing the wall Connection of project-specific services Active section Air discharge and heat exchanger Integration of different functions, e.g. acoustic fleece, lighting or sensors Front end Available in three designs Integration of project-specific functions, e.g. loudspeakers

Nominal sizes 3000 mm DESCRIPTION Variants Induced air grille with various perforation patterns Heat exchanger 2: 2-pipe systems 4: 4-pipe systems Nozzle variants K: Small Z: Small plus M: Medium G: Large Front end Circular Straight Slanted Construction Powder-coated RAL 9010, pure white, gloss level 50 % P1: Powder-coated in any other RAL colour, gloss level 70 % P1: Powder-coated RAL 9006, white aluminium, gloss level 30 % Attachments

Water connection A1: G½" external thread and flat seal Water connection A2: G½" union nut and flat seal Accessories Sprinkler Smoke detector PIR sensor Loudspeaker Indirect and/or direct lighting Volume flow controller Useful additions Connecting hoses Control equipment consisting of a control panel including a controller with integral room temperature sensor; valves and valve actuators; and lockshields (no lighting control) X-AIRCONTROL control system Construction features Spigot is suitable for circular ducts to EN 1506 or EN 13180 Unit consists of three parts: wall end, active section, and front end Four suspension points for on-site installation (by others) Four nozzle variants to optimise induction based on demand Perforated front plate (choice of different designs) with acoustic fleece at the rear Materials and surfaces Wall end as well as active section with front plate and cross bars are made of galvanised sheet steel Front end made of aluminium or galvanised sheet steel Heat exchanger with copper tubes and aluminium fins Exposed surfaces at the front are powder-coated pure white (RAL 9010) or in any other RAL colour Exposed surfaces at the rear, including nozzle box, in RAL 9006, white aluminium Heat exchanger also available in RAL 9006, white aluminium Nozzle plate made of sheet steel

Standards and guidelines Products are certified by Eurovent (no. 09.12.432) and listed on the Eurovent website Declaration of hygiene conformity to VDI 6022 Maintenance No moving parts, hence low maintenance Heat exchanger is easily accessible for cleaning The heat exchanger can be vacuumed with an industrial vacuum cleaner if necessary VDI 6022, Part 1, applies (Hygiene requirements for ventilation and airconditioning systems and units) TECHNICAL INFORMATION Function, Technical data, Quick sizing, Specification text, Order code, Related products FUNCTION Functional description Active chilled beams provide centrally conditioned primary air (fresh air) to the room and use heat exchangers for additional cooling and/or heating. The primary air is discharged through nozzles (four variants are available). As a result of this, secondary air (room air) is induced and passes through the heat exchanger. Primary and secondary air mix and are then supplied to the room horizontally. Schematic illustration of DID-SB

1 Front end 2 Active section 3 Nozzles 4 Wall end 5 Heat exchanger 6 Water connection 7 Primary air spigot Principle of operation DID-SB

1 Conditioned fresh air (primary air) 2 Supply air 3 Room air (secondary air)

TECHNICAL DATA Length 4500 5200 mm Width 750 mm Height 291 mm (plus services) Primary air spigot, diameter 123 mm Primary air volume flow rate 8 33 l/s or 30 120 m³/h Cooling capacity Up to 1000 W Heating capacity Up to 750 W Max. operating pressure, water side 6 bar Max. operating temperature, water side 75 C QUICK SIZING The quick sizing table contains operating points for defined reference units. Quick sizing

LN LN 1 1 Primary air 2 Cooling Heating 2-pipe and 4-pipe systems 4-pipe system VPr Δpt LWA Qtot QWK ΔtW Δpw Q WH = Qtot ΔtW Δpw l/s m³/h Pa db(a) W K kpa W kpa 3000 K 13 47 88 <20 524 366 1.6 4.0 190 2.7 0.21 16 58 133 23 655 461 2.0 4.0 455 6.5 0.21 3000 3000 K 21 76 228 31 830 576 2.5 4.0 744 10.7 0.21 17 61 51 <20 483 279 1.2 4.0 400 5.7 0.21 Z 21 76 79 <20 664 409 1.8 4.0 626 9.0 0.21 Z 25 90 111 24 806 505 2.2 4.0 780 11.2 0.21 3000 ZM 20 72 45 <20 521 280 1.2 4.0 508 7.3 0.21 24 86 64 <20 686 398 1.7 4.0 673 9.6 0.21 3000 3000 ZM 28 101 89 23 837 499 2.1 4.0 809 11.6 0.21 22 80 39 <20 535 267 1.2 4.0 545 7.8 0.21 M 27 97 57 <20 732 407 1.8 4.0 710 10.2 0.21 M 31 112 76 23 881 506 2.2 4.0 824 11.8 0.21 3000 G 35 126 33 21 815 393 1.7 4.0 637 9.1 0.21 40 144 43 25 969 486 2.1 4.0 726 10.4 0.21 3000 G 45 162 54 28 1108 565 2.4 4.0 801 11.5 0.21 1 Nozzle variant 2 Air-regenerated noise Reference values

Parameter Cooling Heating t 26 C 22 C R t 16 C 22 C z t 16 C 50 C WV V W 200 l/h 60 l/h L = 3000 mm N X = 1.5 m R = 3.2 m H A = 3.0 m SPECIFICATION TEXT Active chilled beams of Type DID-SB, with two-way air discharge and high thermal output, providing high thermal comfort levels; for visible installation about 300 mm below the ceiling slab in rooms without a suspended ceiling. Preferably for room heights up to 4.00 m. The units consist of a casing with suspension points, a spigot, non-combustible nozzles, and a horizontal heat exchanger. Four nozzle variants to optimise induction based on demand. Special characteristics Freely suspended active chilled beam with choice of different face plate perforations Heat exchanger as 2-pipe or 4-pipe system Wide range of additional services such as lighting, sprinklers, loudspeakers and sensors (accessories) Water connections at the narrow side, Ø12 mm Cu pipe, with plain tails or with G½" external thread, or with a G½" union nut; with flat seal Wall end Cover for air and water connections at the end facing the wall Connection of project-specific services

Active section Air discharge and heat exchanger Integration of different functions, e.g. acoustic fleece, lighting or sensors Front end Available in three designs Integration of project-specific functions, e.g. loudspeakers Materials and surfaces Wall end as well as active section with front plate and cross bars are made of galvanised sheet steel Front end made of aluminium or galvanised sheet steel Heat exchanger with copper tubes and aluminium fins Exposed surfaces at the front are powder-coated pure white (RAL 9010) or in any other RAL colour Exposed surfaces at the rear, including nozzle box, in RAL 9006, white aluminium Heat exchanger also available in RAL 9006, white aluminium Nozzle plate made of sheet steel Construction Powder-coated RAL 9010, pure white, gloss level 50 % P1: Powder-coated in any other RAL colour, gloss level 70 % P1: Powder-coated RAL 9006, white aluminium, gloss level 30 % Technical data Length: 4500 5200 mm Height: 291 mm (plus services) Width: 750 mm Primary air spigot, diameter: 123 mm Primary air volume flow rate: 8 33 l/s or 30 120 m³/h Cooling capacity: up to 1000 W Heating capacity: up to 750 W Max. operating pressure: 6 bar Max. operating temperature: 75 C

Sizing data Primary air V [m³/h] Δp [Pa] t Air-regenerated noise L [db(a)] WA Cooling Q [W] ges Heating Q [W] ges This specification text describes the general properties of the product. ORDER CODE DID-SB-2-M-3000 500/123/T16/D1

Heat exchanger 2-pipe Nozzle variant Medium Water connections Ø12 mm pipe, plain tails Nominal size 3000 500 mm Spigot diameter 123 mm Exposed surface RAL 9010, pure white Surface of heat exchanger Untreated Light fitting T16 Surface design Hadi Teherani perforation Front end Circular DID-SB-4-G-3000 1000/123/P1/RAL 9006/G4/LED/Z4-Z5-Z6-Z7/D1/S/VS

Heat exchanger 4-pipe Nozzle variant Large Water connections Ø12 mm pipe, plain tails Nominal size 3000 1000 mm Spigot diameter 123 mm Exposed surface P1 RAL 9016, traffic white Surface of heat exchanger RAL 9006, white aluminium Light fitting LED Accessories Two loudspeakers, smoke detector, emergency lighting, PIR sensor Surface design Hadi Teherani perforation Front end Slanted Valves and actuators With

Type DID-SB Active chilled beam Exposed surface No entry: powder-coated Heat exchanger 2 2-pipe 4 4-pipe P1 RAL 9010, pure white Powder-coated, specify RAL CLASSIC colour Gloss level RAL 9010 50 % K Z M G Nozzle variant Small Small plus Medium Large RAL 9006 30 % All other RAL colours 70 % Surface of heat exchanger No entry: untreated G4 White aluminium, RAL 9006, gloss level 30 % Water connections No entry: Ø12 mm pipe with plain tails A1 With G½" external thread and flat seal A2 With G½" union nut and flat seal Light fitting T16 Direct light MPO-D 2 2/28 T16 LDE; indirect light MPO-D 2 1/28 T16 LDE LED Direct light MPO-D LED 96W; indirect light EBL-ID LED, electronic ballast Nominal size (active section wall end) [mm] 3000 500 3000 750 3000 1000 Accessories Z1 Sprinkler bushing, pos. 1 Z2 Sprinkler bushing, pos. 2 Z3 One loudspeaker Z4 Two loudspeakers 123 Spigot diameter [mm] Z5 Z6 Z7 Smoke detector Emergency lighting PIR sensor Surface design D1 Hadi Teherani perforation Front end G S No entry: circular Straight Slanted (45 angle) Valves and actuators No entry: none

VS With Dimensions and weight DIMENSIONS AND WEIGHT Weight [kg] Length 3000/500 3000/750 3000/1000 Contained water (max.) 6 6 6 Unit with rounded front end, without accessories 140 145 150 All accessories + cable 10 10 10 Straight or slanted front end 5 5 5 Dimensions

Installation examples, Installation details, Basic information and nomenclature INSTALLATION EXAMPLES Installation example

INSTALLATION DETAILS Installation and commissioning Preferably for rooms with a clear height up to 4.00 m Freely suspended installation Side entry primary air spigot Total length 4500 5200 mm, width 750 mm Installation and connections to be performed by others; fixing, connection and sealing material to be provided by others Active chilled beam has 4 suspension points for on-site installation (by others) Heat exchangers are fitted with water flow and water return connections BASIC INFORMATION AND NOMENCLATURE L [mm] N Nominal length L [db(a)] WA Sound power level t [ C] Pr Primary air temperature t [C ] WV Water flow temperature cooling/heating t [C ] R Room temperature t [C ] R Room temperature t [C ] AN Secondary air intake temperature Q [W] Pr Thermal output primary air

Q [W] tot Thermal output total Q [W] W Thermal output water side, cooling/heating V [l/s] Pr Primary air volume flow rate V [m³/h] Pr Primary air volume flow rate V [l/h] W Water flow rate cooling/heating V [l/h] Volume flow rate Δt [K] W Temperature difference water Δp [kpa] W Pressure drop, water side Δp [Pa] t Total pressure drop, air side Δt = t - t [K] Pr Pr R Difference between primary air temperature and room temperature Δt = t - t [K] RWV WV R Difference between water flow temperature and room temperature Δt [K] Wm-Ref Difference between mean water temperature and reference temperature L [mm] N Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-10 TROX UK Ltd.

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM Nominal length Mixed flow The supply air is discharged from the diffuser into the space with a velocity between 2 and 5 m/s. The resulting air jet mixes with the room air, ventilating the entire space. Mixed flow systems typically provide a uniform temperature distribution and air quality within the space. The originally high velocity of the turbulent air jet decreases rapidly due to the high induction levels of mixed flow systems. Heat exchanger The maximum water-side operating pressure for all heat exchangers is 6 bar. The maximum water flow temperature (heating circuit) for all heat exchangers is 75 C; if flexible hoses are used, the water flow temperature should not exceed 55 C. Units for other pressures and temperatures are available on request. The water flow temperature (cooling circuit) should be at least 16 C such that it does not permanently fall below the dew point. For units with a condensate drip tray the water flow temperature may be reduced to 15 C. Heat exchanger as 2-pipe system Air-water systems with a 2-pipe heat exchanger may be used for either heating or cooling. In changeover mode it is possible to use all units within a water circuit exclusively for cooling in summer and exclusively for heating in winter. Heat exchanger as 4-pipe system Air-water systems with a 4-pipe heat exchanger may be used for both heating and cooling. Depending on the season, i.e. especially in spring and autumn, it may be possible that an office has to be heated in the morning and cooled in the afternoon. Schematic illustration of mixed flow ventilation Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-10 TROX UK Ltd.

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM Wärmeübertrager 2-Leiter-System Wärmeübertrager 4-Leiter-System Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-10 TROX UK Ltd.

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM TROX UK Ltd Online-Services Service-Hotlines TROX Academy Your contact partner Our Office London Our Office Thetford Sales: +44 (0)1842 754545 Contact Service: +44 (0)1842 754545 Contact Caxton Way, Thetford, Norfolk, IP24 3SQ, UK Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 Technical service +44 (0)1842 754545 Contact General Enquiries info@troxuk.co.uk Sales & Customer Services sales@troxuk.co.uk Accounts accounts@troxuk.co.uk Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-10 TROX UK Ltd.