MODELS SSS 7L-B, 14L-B, 26L-B, 33L-B AND MODELS SSS 7LK-B, 14LK-B, 26LK-B, 33LK-B

Similar documents
RENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813)

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

WIRING DIAGRAMS MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH SSS, LV VSD W/ MODBUS, & MV VSD

FIELD CONNECTIONS MODEL YK CHILLERS (STYLE F AND G) WITH VARIABLE SPEED DRIVE

WIRING DIAGRAM MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER

TON KW 60HZ

R-410A KW 50HZ

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

QTC2015T, 020T, 025T, 030T, 035T, 040T, and 045T

CONTROLS AND INSTRUMENTATION MODEL YST STEAM-TURBINE DRIVE CENTRIFUGAL LIQUID CHILLER

FOR OT/HT MODEL CHILLERS STYLE B AND C CONTROL CENTERS , AND

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE "A"

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-060BK/DP WATERSIDE ECONOMIZER FOR CSV060B LEFT-HAND VERTICAL R-410A STYLE B

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP

MODEL CYK CHILLER WITH LIQUID COOLED SOLID STATE STARTER, OR REMOTE STARTER

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Model CPV120 Waterside Economizer Kit WATERSIDE ECONOMIZER KIT FOR MODEL CPV 120 WATER-COOLED AIR CONDITIONERS INSTALLATION INSTRUCTIONS

CENTRIFUGAL LIQUID CHILLER WITH ECONOMIZER COMPRESSOR MODEL YKEP TON. R-134a

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

MANUAL INSTALLATION. Linear Plenum Terminal. LPT Series. v001 Issue Date: 06/06/ Price Industries Limited. All rights reserved.

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Overspeed Adjustable Valve

DIMENSION AND SELECTION GUIDE

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-300BK/DP WATERSIDE ECONOMIZER FOR CSV300B LEFT-HAND VERTICAL R-410A STYLE B

REPAIR PARTS. 1.5 and 2.5 Ton A SERIES Air Handler w/coil

TON KW 60HZ

MODELS YCAL0019, 0022, 0028, 0033, 0043, 0046, 0052, 0056, AND 0066

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

MODEL YVAA STYLE A AIR-COOLED SCREW LIQUID CHILLERS WITH VARIABLE SPEED DRIVE YVAA FRAME SIZE COMPRESSOR 60 HZ ( TONS)

Technical Manual. DLM Module. This manual should remain with the unit.

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

MATERIAL LIST SPECIFIC TO PART #05724

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

MATERIAL LIST PD7C. PACR WINCH DIVISION P.O. Box 547 Broken Arrow, Oklahoma PHONE: (918) FAX: (918)

K B J K A C H D E I F. Single and Bi-Parting Electric Sliding Doors with Automatic Operator (ICC-5) Parts List. R-PLUS Cold Storage Doors

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-120BKR/DPR WATERSIDE ECONOMIZER FOR CSV096B/120B RIGHT-HAND VERTICAL R-410A STYLE B

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Owner's/Installation Manual

AC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A.

File In/With: - Equipment Affected: Danfoss valves must have Danfoss controllers. Sporlan (Parker) valves must have Sporlan (Parker) controllers.

File In/With: Equipment Affected:

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

MANUAL INSTALLATION. Modular Floor Diffusers. MFD Series. v102 Issue Date: 03/23/ Price Industries Limited. All rights reserved.

Derailment Detector Assembly

ClassicSeries Compressor Installation

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Titan Multistage Chiller With

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

File In/With: N/A. Equipment Affected: TXV Standard with ETRE (old) used as an option on some units. Brine units use TXV and SOL.

WCA4**4. Product Specifications

INSTALLATION MANUAL AND PARTS LIST

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

INSTALLATION INSTRUCTIONS

Product Manual (Revision A) Original Instructions. EG-3P Actuator Installation on Detroit Diesel V-149 Engine. Kit Installation Manual

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Installation Instructions

Installation Instructions

ELEMENTARY DIAGRAM CONNECTION DIAGRAM CONTROL PANEL AND CONNECTION DIAGRAM SYSTEM WIRING FOR MODELS:

LED Downlight Ceiling Fixtures

SPECIFICATIONS. General Specifications. Dimensions

MATERIAL LIST LB400B RD400B SD400B TD400B. (Covering Part Numbers 05194, 05275, 05276, 05278)

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Section 10 Chapter 20

SeasonPak Packaged Air-Cooled Water Chiller

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Removable Applied Panel Mounting System

F261 Series Fluid Flow Switches

Installation Instructions

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Electrical Data Supplement

McQuay Air-Cooled Reciprocating Chiller ALR

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Architectural Hydronic Wall Fin

REPLACEMENT PARTS MANUAL

HLS Watt Halogen Illuminator Service Manual

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

PCCA POWER CONNECT CARD. DS200PCCAG1A thru DS200PCCAG10A

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil

TECHNICAL INFORMATION MANUAL

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

MODEL ELC-12/60-D BATTERY CHARGER

Transcription:

STYLE B LIQUID COOLED SOLID STATE STARTERS REPLACEMENT PARTS Supersedes: 160.00-RP3 (500) Form 160.00-RP3 (614) MODELS SSS 7L-B, 14L-B, 26L-B, 33L-B AND MODELS SSS 7LK-B, 14LK-B, 26LK-B, 33LK-B 00282VIP Issue Date: June 6, 2014

IMPORTANT! READ BEFORE PROCEEDING! GENERAL SAFETY GUIDELINES This equipment is a relatively complicated apparatus. During installation, operation maintenance or service, individuals may be exposed to certain components or conditions including, but not limited to: refrigerants, materials under pressure, rotating components, and both high and low voltage. Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and responsibility of operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in which it is situated, as well as severe personal injury or death to themselves and people at the site. This document is intended for use by owner-authorized operating/service personnel. It is expected that these individuals possess independent training that will enable them to perform their assigned tasks properly and safely. It is essential that, prior to performing any task on this equipment, this individual shall have read and understood this document and any referenced materials. This individual shall also be familiar with and comply with all applicable governmental standards and regulations pertaining to the task in question. SAFETY SYMBOLS The following symbols are used in this document to alert the reader to specific situations: Indicates a possible hazardous situation which will result in death or serious injury if proper care is not taken. Identifies a hazard which could lead to damage to the machine, damage to other equipment and/or environmental pollution if proper care is not taken or instructions and are not followed. Indicates a potentially hazardous situation which will result in possible injuries or damage to equipment if proper care is not taken. Highlights additional information useful to the technician in completing the work being performed properly. External wiring, unless specified as an optional connection in the manufacturer s product line, is not to be connected inside the control cabinet. Devices such as relays, switches, transducers and controls and any external wiring must not be installed inside the micro panel. All wiring must be in accordance with Johnson Controls published specifications and must be performed only by a qualified electrician. Johnson Controls will NOT be responsible for damage/problems resulting from improper connections to the controls or application of improper control signals. Failure to follow this warning will void the manufacturer s warranty and cause serious damage to property or personal injury. 2 JOHNSON CONTROLS

CHANGEABILITY OF THIS DOCUMENT In complying with Johnson Controls policy for continuous product improvement, the information contained in this document is subject to change without notice. Johnson Controls makes no commitment to update or provide current information automatically to the manual owner. Updated manuals, if applicable, can be obtained by contacting the nearest Johnson Controls Service office or accessing the Johnson Controls QuickLIT website at http://cgproducts.johnsoncontrols.com. Operating/service personnel maintain responsibility for the applicability of these documents to the equipment. If there is any question regarding the applicability of these documents, the technician should verify whether the equipment has been modified and if current literature is available from the owner of the equipment prior to performing any work on the chiller. CHANGE BARS Revisions made to this document are indicated with a line along the left or right hand column in the area the revision was made. These revisions are to technical information and any other changes in spelling, grammar or formatting are not included. HOW TO USE RENEWAL PARTS MANUALS Johnson Controls offers an assortment of replacements parts for Johnson Controls, YORK and UPG units. Each replacement part is manufactured and fitted for a specific model. This Replacement Parts Manual is for standard Johnson Controls units. Chiller units built with special options, modifications, or conversions are not covered in this manual. This Replacement Parts Manual provides Johnson Controls chiller replacement parts by part numbers, descriptions, quantities and drawing figures. To determine the correct replacement part, locate the item on drawing figure and refer to the parts list for the part number, description and quantity. NOTE: Provide a unit model number, unit serial number and part number when requesting a quotation or placing an order. Failure to include this information may delay processing of your request. Model and Serial Number Locations: Unit - Namplate on side of Control Panel Compressor - Namplate on Compressor Housing VSD - Namplate on VSD Panel Contact the following sources to order parts. NORTH AMERICA Baltimore Parts Center Contrators within USA Telephone: (800)-932-1701 Equipment Owners within USA who maintain their own equipment Telephone: (800)-482-2778 Email: cg-baltimore-parts-customer@jci.com For parts availability and ordering YORK HVAC Parts within the USA please use the following link: http://www.johnsoncontrols.com/content/us/en/products/building_efficiency/products-and-systems/integrated_hvac_systems/parts_center/baltimorepartscenter.html EUROPE HVAC Parts Centre (Europe) Telephone: +44 (0) 1268 246 400 Email: ALLParts@jci.com JOHNSON CONTROLS 3

THIS PAGE INTENTIONALLY LEFT BLANK. 4 JOHNSON CONTROLS

LIST OF TABLES TABLE 1 - Common Parts for all Models...7 TABLE 2 - Common Parts Per Model...7 TABLE 3 - Variable Parts for all 7L Models...8 TABLE 4 - Variable Parts for all 7LK Models...8 TABLE 5 - Variable Parts for all 14L Models...8 TABLE 6 - Variable Parts for all 14L Models (Cont'd)...8 TABLE 7 - Variable Parts for all 14LK Models...9 TABLE 8 - Variable Parts for all 14LK Models (Cont'd)...9 TABLE 9 - Variable Parts for all 26L Models...9 TABLE 10 - Variable Parts for all 26L Models (Cont'd)...9 TABLE 11 - Variable Parts for all 26LK Models...10 TABLE 12 - Variable Parts for all 26LK Models (Cont'd)...10 TABLE 13 - Variable Parts for all 33L Models...10 TABLE 14 - Variable Parts for all 33L Models (Cont'd)...10 TABLE 15 - Variable Parts for all 33LK Models... 11 TABLE 16 - Variable Parts for all 33LK Models (Cont'd)... 11 TABLE 17 - Input Power Replacements and Options...12 TABLE 19 - SCR Replacement Kit ( Style None A and B)...13 TABLE 20 - SCR Replacement Kit ( Style None A and B)...13 TABLE 21 - Common Parts 375-03048-001...13 JOHNSON CONTROLS 5

THIS PAGE INTENTIONALLY LEFT BLANK. 6 JOHNSON CONTROLS

Table 1 - COMMON PARTS FOR ALL MODELS 1 Logic / Trigger Board 60 Hz applications (includes 031-02505-001 board) 031-02757-002 2 Logic / Trigger Board 50 Hz applications (includes 031-02505-002 board) 031-02757-003 2 2 Capacitor, Assembly 371-01086-000 5 3 Fuseholder for 7FU 025-34186-000 3 4 Fuseholder for 1FU-6FU ( 1 of 2 ) 025-34185-000 3 5 Fuse, 4 Amp 7 FU 025-27973-000 3 6 Fastener, Panel Adj. 021-17252-000 1 7 Hose Barb, Plastic - Threads Into SCR Brick Assembly 023-20205-000 6 8 Hose, Clear Plastic order by the foot 028-12239-000 6 9 Coolant Header 3" PVC with Fill Plug 371-02561-513 6 10 Heat Exchanger 026-36596-000 6 Not Shown Hose, connect heat exchanger to condenser water 150 PSI., 50 Ft Roll 028-11958-000 Not Shown Hose, connect heat exchanger to condenser water 300 PSI., 50 Ft Roll 028-11959-000 11 Temperature Sensor kit ( thermistor, lugs, and plug ) 031-02758-000 5 12 U16 Logic / Trigger Board EPROM (used on 031-02001-xxx board) 031-02029-001 2 12 U16 Logic / Trigger Board EPROM (used on 031-02505-xxx board) 031-02541-001 13 U15 Battery Backed RAM for the Logic / Trigger Board 031-01620-000 2 14 Coolant Pump 50 / 60 Hz 026-32813-000 6 Not Shown Inhibitor, Coolant 013-02987-000 Table 2 - COMMON PARTS PER MODEL 7L 7LK 14L 14LK 26L 26LK 33L 33LK 15 Ground Terminal 025-34196-000 025-34197-000 025-34198-000 025-34198-000 2 Not Shown Terminal Lug Kit ( 3 Lugs ) 371-02576-101 371-02576-102 371-02576-103 371-02576-104 * 16 Bus Bar ( L1 ) 371-02500-003 371-02500-003 371-01082-006 371-01082-006 4 17 Bus Bar ( L2 ) 371-02500-002 371-02500-002 371-01082-005 371-01082-005 4 18 Bus Bar ( L3 ) 371-02500-001 371-02500-001 371-01082-004 371-01082-004 4 19 Output Current Transformer 025-34195-001 025-34195-002 025-34195-003 025-37195-004 4, 5 JOHNSON CONTROLS 7

Table 3 - VARIABLE PARTS FOR ALL 7L MODELS 7L-40B 7L-46B 7L-58B 7L-50B 20 SCR Assembly Kit 1 of 3 375-03048-002 375-03048-002 375-03048-003 375-03048-002 4, 5 21 Fuse ( 1FU 3FU ) 025-34136-000 025-34135-000 025-34194-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34137-000 025-34136-000 025-34135-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-003 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02568-006 371-02568-004 371-02568-005 371-02568-006 1 Table 4 - VARIABLE PARTS FOR ALL 7LK MODELS 7LK-40B 7LK-46B 7LK-58B 7LK-50B 20 SCR Assembly Kit 1 of 3 375-03048-002 375-03048-002 375-03048-003 375-03048-002 4, 5 21 Fuse ( 1FU 3FU ) 025-34136-000 025-34136-000 025-34540-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34140-000 025-34139-000 025-34137-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-003 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02569-006 371-02569-004 371-02569-005 371-02569-006 1 Table 5 - VARIABLE PARTS FOR ALL 14L MODELS 14L-17B 14L-28B 14L-40B 20 SCR Assembly Kit 1 of 3 375-03048-004 375-03048-004 375-03048-004 4, 5 21 Fuse ( 1FU 3FU ) 025-34140-000 025-34140-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34141-000 025-34141-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 371-02568-002 371-02568-003 371-02568-006 1 Table 6 - VARIABLE PARTS FOR ALL 14L MODELS (CONT'D) 14L-46B 14L-58B 14L-50B 20 SCR Assembly Kit 1 of 3 375-03048-004 375-03048-005 375-03048-004 4, 5 21 Fuse ( 1FU 3FU ) 025-34135-000 025-34194-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34136-000 025-34135-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02568-004 371-02568-005 371-02568-006 1 8 JOHNSON CONTROLS

Table 7 - VARIABLE PARTS FOR ALL 14LK MODELS 14LK-17B 14LK-28B 14LK-40B 20 SCR Assembly Kit 1 of 3 375-03048-004 375-03048-004 375-03048-004 4, 5 21 Fuse ( 1FU 3FU ) 025-34141-000 025-34141-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34142-000 025-34142-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 371-02569-002 371-02569-003 371-02569-006 1 Table 8 - VARIABLE PARTS FOR ALL 14LK MODELS (CONT'D) 14LK-46B 14LK-58B 14LK-50B 20 SCR Assembly Kit 1 of 3 375-03048-004 375-03048-005 375-03048-004 4, 5 21 Fuse ( 1FU 3FU ) 025-34136-000 025-34540-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34139-000 025-34137-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02569-004 371-02569-005 371-02569-006 1 Table 9 - VARIABLE PARTS FOR ALL 26L MODELS 26L-17B 26L-28B 26L-40B 20 SCR Assembly Kit 1 of 3 375-03048-006 375-03048-006 375-03048-006 4, 5 21 Fuse ( 1FU 3FU ) 025-34140-000 025-34140-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34141-000 025-34141-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 371-02568-002 371-02568-003 371-02568-006 1 Table 10 - VARIABLE PARTS FOR ALL 26L MODELS (CONT'D) 26L-46B 26L-58B 26L-50B 20 SCR Assembly Kit 1 of 3 375-03048-006 375-03048-007 375-03048-006 4, 5 21 Fuse ( 1FU 3FU ) 025-34135-000 025-34194-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34136-000 025-34135-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02568-004 371-02568-005 371-02568-006 1 JOHNSON CONTROLS 9

Table 11 - VARIABLE PARTS FOR ALL 26LK MODELS 26LK-17B 26LK-28B 26LK-40B 20 SCR Assembly Kit 1 of 3 375-03048-006 375-03048-006 375-03048-006 4, 5 21 Fuse ( 1FU 3FU ) 025-34141-000 025-34141-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34142-000 025-34142-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 371-02569-002 371-02569-003 371-02569-006 1 Table 12 - VARIABLE PARTS FOR ALL 26LK MODELS (CONT'D) 26LK-46B 26LK-58B 26LK-50B 20 SCR Assembly Kit 1 of 3 375-03048-006 375-03048-007 375-03048-006 4, 5 21 Fuse ( 1FU 3FU ) 025-34136-000 025-34540-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34139-000 025-34137-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-003 371-02564-004 371-02564-003 5 25 Control Power Transformer 371-02569-004 371-02569-005 371-02569-006 1 Table 13 - VARIABLE PARTS FOR ALL 33L MODELS 33L-17B 33L-28B 33L-40B 20 SCR Assembly Kit 1 of 3 375-03048-008 375-03048-008 375-03048-008 4, 5 21 Fuse ( 1FU 3FU ) 025-34140-000 025-34140-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34141-000 025-34141-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 375-02568-002 375-02568-003 375-02568-006 1 Table 14 - VARIABLE PARTS FOR ALL 33L MODELS (CONT'D) 33L-46B 33L-50B 20 SCR Assembly Kit 1 of 3 375-03048-008 375-03048-008 4, 5 21 Fuse ( 1FU 3FU ) 025-34135-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34136-000 025-34137-000 3 23 Fuse ( 6FU ) 025-34141-000 025-34141-000 3 24 Snubber Resistor 371-02564-003 371-02564-003 5 25 Control Power Transformer 375-02568-004 375-02568-006 1 10 JOHNSON CONTROLS

Table 15 - VARIABLE PARTS FOR ALL 33LK MODELS 33LK-17B 33LK-28B 33LK-40B 20 SCR Assembly 1 of 3 375-03048-008 375-03048-008 375-03048-008 4, 5 21 Fuse ( 1FU 3FU ) 025-34141-000 025-34141-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34142-000 025-34142-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-002 371-02564-002 371-02564-003 5 25 Control Power Transformer 371-02569-002 371-02569-003 371-02569-006 1 Table 16 - VARIABLE PARTS FOR ALL 33LK MODELS (CONT'D) 33LK-46B 33LK-50B 20 SCR Assembly 1 of 3 375-03048-008 375-03048-008 4, 5 21 Fuse ( 1FU 3FU ) 025-34136-000 025-34136-000 3 22 Fuse ( 4FU 5FU ) 025-34139-000 025-34140-000 3 23 Fuse ( 6FU ) 025-34142-000 025-34142-000 3 24 Snubber Resistor 371-02564-003 371-02564-003 5 25 Control Power Transformer 371-02569-004 371-02569-006 1 JOHNSON CONTROLS 11

Table 17 - INPUT POWER REPLACEMENTS AND OPTIONS Replacement Kit to Convert from a 'S' type to a 'T' type Disconection Switch 26 PART NUMBER Replacement Disconnect Switch 250 Amp 371-02565-601 2 Replacement Disconnect Switch 400 Amp 371-02565-603 2 Replacement Disconnect Switch 600 Amp 371-02565-605 2 Replacement Disconnect Switch 1200 Amp 371-02565-607 2 For UL Applications Replacement Kit to Convert from a 'S' type to a 'T' type Circuit Breaker 26 Replacement Circuit Breaker 250 Amp 371-02566-601 2 Replacement Circuit Breaker 400 Amp 371-02566-603 2 Replacement Circuit Breaker 600 Amp 371-02566-605 2 Replacement Circuit Breaker 960 Amp 371-02566-607 2 Replacement Circuit Breaker 1200 Amp 371-02566-609 2 For CE Applications Replacement Kit to Convert from a 'S' type to a 'T' type Circuit Breaker 26 Replacement Circuit Breaker 250 Amp 371-03671-601 2 Replacement Circuit Breaker 400 Amp 371-03671-603 2 Replacement Circuit Breaker 600 Amp 371-03671-605 2 Replacement Circuit Breaker 960 Amp 371-03671-607 2 Replacement Circuit Breaker 1200 Amp 371-03671-609 2 27 Channel Insulator for 1200 Amp Disconnect Switch, 960 and 1200 Circuit Breaker 071-01127-000 2 Use these part numbers when replaceing a 'T' type Disconnect Switch 26 Replacement Disconnect Switch 250 Amp 024-37497-000 Replacement Disconnect Switch 400 Amp 024-37498-000 Replacement Disconnect Switch 600 Amp 024-37499-000 Replacement Disconnect Switch 1200 Amp 024-37500-000 For UL Applications Use these part numbers when replaceing a 'T' type Circuit Breaker 26 Replacement Circuit Breaker 250 Amp 224-37493-000 Replacement Circuit Breaker 400 Amp 224-37494-000 Replacement Circuit Breaker 600 Amp 224-37495-000 Replacement Circuit Breaker 960 Amp 224-37501-000 Replacement Circuit Breaker 1200 Amp 224-37496-000 Normally, the disconnect switch and circuit breaker are factory installed. However, there may be times when the customer may desire to have these options installed after the starter has already been shipped from the factory. The part number for these kits should use the replacement kit where the switch device designed has changed from the 'S' type to the 'T' type. The full load rating for these device are listed below. DISCONNECT SWITCH SIZE FULL LOAD RANGE 250 Amps 0-217 Amps 400 Amps 0-348 Amps 600 Amps 0-522 Amps 1200 Amps 0-1043 Amps CIRCUIT BREAKER SIZE FULL LOAD RANGE 250 Amps 100-250 Amps 400 Amps 178-400 Amps 600 Amps 267-600 Amps 960 Amps 426-960 Amps 1200 Amps 533-1200 Amps 12 JOHNSON CONTROLS

Table 19 - SCR REPLACEMENT KIT ( STYLE NONE A AND B) DISCRIPTION 7L 40, 46, 50 7L 58 14L 17, 28, 40, 46, 50 14L-58 375-03048-002 375-03048-003 375-03048-004 375-03048-005 PART NUMBER QTY. PART NUMBER QTY. PART NUMBER QTY. PART NUMBER 20 Common Parts 375-02048-001 1 375-02048-001 1 375-02048-001 1 375-02048-001 1 21 Rectifier Assy. 371-02541-332 1 371-02541-333 1 371-02541-334 1 371-02541-335 1 22 Standoff ------------------ --- ------------------ --- ------------------- --- ------------------ --- QTY. Table 20 - SCR REPLACEMENT KIT ( STYLE NONE A AND B) 26L - 17, 28, 40, 46, 50 26L-58 33L - 17, 28, 40, 46, 50 375-03048-006 375-03048-007 375-03048-008 DISCRIPTION QTY. QTY. QTY. 20 Common Parts 375-02048-001 1 375-02048-001 1 375-02048-001 1 21 Rectifier Assy. 371-02542-332 1 371-02542-333 1 371-02543-332 1 22 Standoff 021-17565-000 2 021-17565-000 2 021-17565-000 2 Table 21 - COMMON PARTS 375-03048-001 PART NUMBER QUANTITY PER KIT 1 Instruction. Installation 075-03048-000 1 2 Inhibitor, Corrosion AL/CU 013-02987-000 1 3 Hose Clamp 021-17547-000 4 4 Hose Barb 023-16247-000 2 5 Tube, Plastic 7/16 I.D. 028-12239-000 4.25 FT 6 Nipple, Brass ¼ NPT X 7/8 023-16260-000 2 7 Fitting, ¼ Int. X3/8 Ext Fl. 023-00900-000 2 8 Compound, Anti-Oxidant 013-02880-000 1 9 Bag, Cloth W/Drawstring 030-00755-000 1 JOHNSON CONTROLS 13

Optional Disconnect Switch or Curcuit Breaker 6 25 00388VIP Figure 1 - SOLID START STARTER - FRONT VIEW, EXTERIOR 14 JOHNSON CONTROLS

15 26 1 12 27 00390VIP 13 Figure 2 - SOLID START STARTER - INTERIOR VIEW JOHNSON CONTROLS 15

21 4 22 5 23 3 00391VIP Figure 3 - SOLID START STARTER - FUSE DETAIL 16 JOHNSON CONTROLS

19 18 00392VIP 17 20 16 Figure 4 - SOLID START STARTER - POWER SECTION DETAIL JOHNSON CONTROLS 17

19 11 24 20 2 00393VIP Figure 5 - SOLID START STARTER - SCR POLE DETAIL 18 JOHNSON CONTROLS

9 8 14 00394VIP 7 8 10 Figure 6 - SOLID START STARTER - REAR VIEW, COOLING LOOP JOHNSON CONTROLS 19

NOTES 20 JOHNSON CONTROLS

The following factors can be used to convert from English to the most common SI Metric values. Table 22 - SI METRIC CONVERSION MEASUREMENT MULTIPLY ENGLISH UNIT BY FACTOR TO OBTAIN METRIC UNIT Capacity Tons Refrigerant Effect (ton) 3.516 Kilowatts (kw) Power Horsepower 0.7457 Kilowatts (kw) Flow Rate Gallons / Minute (gpm) 0.0631 Liters / Second (l/s) Length Feet (ft) 0.3048 Meters (m) Inches (in) 25.4 Millimeters (mm) Weight Pounds (lbs) 0.4538 Kilograms (kg) Velocity Feet / Second (fps) 0.3048 Meters / Second (m/s) Pressure Drop Feet of Water (ft) 2.989 Kilopascals (kpa) Pounds / Square Inch (psi) 6.895 Kilopascals (kpa) TEMPERATURE To convert degrees Fahrenheit ( F) to degrees Celsius ( C), subtract 32 and multiply by 5/9 or 0.5556. Example: (45.0 F - 32 ) x 0.5556 = 27.2 C To convert a temperature range (i.e., a range of 10 F) from Fahrenheit to Celsius, multiply by 5/9 or 0.5556. Example: 10.0 F range x 0.5556 = 5.6 C range JOHNSON CONTROLS 21

P.O. Box 1592, York, Pennsylvania USA 17405-1592 800-861-1001 Subject to change without notice. Printed in USA Copyright by Johnson Controls 2014 www.johnsoncontrols.com ALL RIGHTS RESERVED Form 160.00-RP3 (614) Issue Date: June 6, 2014 Supersedes: 160.00-RP3 (500)