adaptable, reliable underfloor power

Similar documents
Electrak powertrack / underfloor busbar system

Electrak power track underfloor power distribution systems

Underfloor to desk 231

Underfloor Busbar. Betatrak Underfloor Busbar. 82

Betatrak Compliance Standard

Arena-Walsall power track system standard

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

Floor boxes... choice, flexibility and easy installation

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

KAP A Plug-in Busbar Distribution System IEC ME 04

Interact Underfloor Power

FLOOR DISTRIBUTION SYSTEMS

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Snake Bus Power Distribution

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

6491B / H07Z-R / BS EN Cable

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

elevate your flexibility

STERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

DX³ RCCBs - ID 4P up to 100 A

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

New DX 3 High rating & breaking capacity

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Plexo 3 weatherproof cabinets

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

ype UP T Busplugs Low Voltage Switchboard Equipment

PSU EN54-4 Power Supplies

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Screed Floor system LIMOGES Cedex. Phone : Fax :

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

Electronic Circuit Breaker ESS20-0..

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

Calculation of the Cross-sectional Areas of Circuit Live Conductors

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

XL Distribution enclosures WORKSHOP SPECIFICATIONS

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

PART 10 ELECTRICAL INSTALLATIONS

Floor outlet boxes British Standard

Viking 3 - Screw connection Disconnect terminal blocks

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Powerline. Single Power Connectors. Ten 47 Limited

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

WavePro LT Busway Cost effective solution for electrical distribution

8WH2 Spring-Loaded Terminals

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Intelligent Choice for Prestigious Buildings

LB - LIGHTING BUSWAY 25-40A

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

PART 8 ELECTRICAL INSTALLATIONS

8WH2 Spring-Loaded Terminals

Synergy WIRING ACCESSORIES / PRODUCT GUIDE

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

FUSEHOLDERS. Type Fuse Size (mm) Page. Type Fuse Size (mm) Page

HIGH POWERBAR COPPER UL857

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

Unarmoured Single-Core Cables to BS6883

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

SWITCH SHOULD BE ON THE UPPER SIDE!

Distribution Blocks & Bus-bar Solutions

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Phase + Neutral, neutral on right side

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

TX³ RCCBs 2P up to 100 A

Modular contactors and relays

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

workshop specifications Plexo³ IP 65 cabinets

Circuit Breaker Types

DX³ 4-pole RCBO 6000 A/10 ka

FUSEHOLDERS. Type Fuse Size (mm) Page. Type Fuse Size (mm) Page

Powerline. Single Power Connectors. + Ten 47. Ten 47 Limited

Phase + Neutral, neutral on left side

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Miniature Circuit Breaker

Electrical Awareness and Considerations

BUSBAR TRUNKING SYSTEMS a

Powerline QC. Single Power Connectors. Ten 47 Limited

Guidelines How To Wire DRH Modules

Circuit Breaker Types

Energy Supply Systems

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

68 Q-DIN Range. Trade Catalogue Energy 2013 > Energy > Combined units to IEC 309 > 68 Q-DIN Range. Distribution boards UNWIRED VERSIONS

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM

Transcription:

adaptable, POWERTRACK reliable adaptable, reliable underfloor power 6

THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes and grommets, this flexible, easy-to-install system can be reconfigured as office layouts evolve. The system consists of continuous lengths of track which are fed via a feed unit and can be installed in floor voids as low as 48mm. n 6 A rated, IP 40 protection n Available in five versions: single phase, clean earth, dual circuit, three phase and auxiliary earth n Tinned busbar version available for use within Abu Dhabi (see page 1) n Available in 1.2m, 1.8m, 2.4m and.6m lengths n Tap-off outlets are located at every 00 or 600mm pitch n Floor mountable (stand-off brackets also available) Integral track connector plugs into feed unit Lengths simply push-fit together Integral fixing brackets for rapid installation Tap-offs plug into shuttered socket outlets and lock onto track body 7

Electrak powertrack / underfloor busbar system selection chart Description Length (m) Track lengths with 00 mm socket centres 4 outlets 1 2 6 outlets 1 8 8 outlets 2 4 12 outlets 6 Track feeds Excluding cables and conduit Flexible metal conduit Flexible metal conduit Standard tap-off / auxiliary earth tap-off Low noise / clean earth tap-off Dual circuit tap-off 2 A unfused 16 mm Ø L, N, PE 1 A fused 16 mm Ø L, N, PE 1 A 4 7 fused 16 mm Ø L, N, PE 2 A unfused 16 mm Ø CE, L, N, PE 1 A fused 16 mm Ø CE, L, N, PE 1 A 4 7 fused 16 mm Ø CE, L, N, PE 2 A unfused 20 mm Ø CE, L1, N1 L2, N2, PE phase tap-off 2 A 41 V phase 20 mm Ø L1, L2, L, N, PE 2 A L1 unfused reconfigurable live pin 16 mm Ø L1, N, PE 2 A L2 unfused reconfigurable live pin 16 mm Ø L2, N, PE 2 A L unfused reconfigurable live pin 16 mm Ø L, N, PE Key code / Busbar arrangement 8

ELECTRAK 24 Standard system (white) ELECTRAK 2 Low noise / clean earth system (green) ELECTRAK 26 Dual circuit system (dark green) ELECTRAK 27 phase system (grey) ELECTRAK 28 Auxiliary earth system (red) DA112 JA212 KA12 NA412 YA12 DA118 JA218 KA18 NA418 YA18 DA124 JA224 KA24 NA424 YA24 DA16 JA26 KA6 NA46 YA6 DF1010 JF2010 KF010 NF4010 YF010 DW1000 JW2000 KW000 NW4000 YW000 DW1010 JW2010 KW010 NW4010 YW010 DW1020 JW2020 KW020 NW4020 YW020 DP12 DP12 YP2 DP12 DP12 YP2 DP11 DP11 YP1 DP11 DP11 YP1 DP127 DP127 YP27 DP127 DP127 YP27 JP22 JP22 JP22 JP22 JP21 JP21 JP21 JP21 JP227 JP227 JP227 JP227 KP28 KP28 NZ41 NZ41 NP42 1 NP42 1 NP402 1 NP402 1 NP40 1 NP40 1 PE N2 L2 PE CE N1 L1 PE CE N1 L1 N2 L2 PE N L1 L2 L PE N1 L1 1 : All NP tap-offs are reconfigurable between L1, L2 or L for phase track 9

Electrak 24 powertrack / underfloor busbar system standard system (white) DF1010 DW1010 - - -/- - - DA112 DP12 Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Track system components Pack Cat. Nos. Tap-off units Electrak 24 standard track lengths Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 DA112 1 2 m, 4 outlets, 2 floor fixing brackets 1 DA118 1 8 m, 6 outlets, 2 floor fixing brackets 1 DA124 2 4 m, 8 outlets, 2 floor fixing brackets 1 DA16 6 m, 12 outlets, floor fixing brackets Track feed unit 1 DF1010 With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 DW1000 Excluding cables and conduit 1 DW1010 1 2 m flexible metal conduit 1 DW1020 2 4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ120 For fitting under integral track connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 2 A 2 A unfused 1 DP12 m 1 DP12 m 1 A fused 1 DP11 m 1 DP11 m 1 A 4 7 fused - high integrity 1 DP127 m 1 DP127 m Tap-off units specifically for the U.A.E. To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits and minimum 4 mm 2 conductors 2 A unfused L (red), N (black), PE (green/yellow) 1 DP12R m U.A.E. 1 DP12R m U.A.E. 1 A fused L (red), N (black), PE (green/yellow) 1 DP114R m U.A.E. 1 DP114R m U.A.E. 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 10

Electrak 2 powertrack / underfloor busbar system low noise / clean earth system (green) JF2010 JW2010 - - -/- - - JA212 JP22 Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Track system components Pack Cat. Nos. Tap-off units Electrak 2 low noise / clean earth track lengths Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 JA212 1 2 m, 4 outlets, 2 floor fixing brackets 1 JA218 1 8 m, 6 outlets, 2 floor fixing brackets 1 JA224 2 4 m, 8 outlets, 2 floor fixing brackets 1 JA26 6 m, 12 outlets, floor fixing brackets Track feed unit 1 JF2010 With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 JW2000 Excluding cables and conduit 1 JW2010 1 2 m flexible metal conduit 1 JW2020 2 4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ120 For fitting under integral track connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 2 A 2 A unfused 16 mm Ø CE, L, N, PE 1 JP22 m 1 JP22 m 1 A fused 16 mm Ø CE, L, N, PE 1 JP21 m 1 JP21 m 1 A 4 7 fused - high integrity 16 mm Ø CE, L, N, PE 1 JP227 m 1 JP227 m 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 11

Electrak 26 powertrack / underfloor busbar system dual circuit system (dark green) KF010 KW010 - - -/- - - KA12 KP28 Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Track system components Pack Cat. Nos. Tap-off units The dual powertrack system has both standard and low noise / clean earth systems incorporated Electrak 26 dual circuit track lengths Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 KA12 1 2 m, 4 outlets, 2 floor fixing brackets 1 KA18 1 8 m, 6 outlets, 2 floor fixing brackets 1 KA24 2 4 m, 8 outlets, 2 floor fixing brackets 1 KA6 6 m, 12 outlets, floor fixing brackets Track feed unit 1 KF010 With two 2 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 KW000 Excluding cables and conduit 1 KW010 1 2 m flexible metal conduit 1 KW020 2 4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ120 For fitting under integral track connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 2 A Standard 2 A unfused 1 DP12 m 1 DP12 m Standard 1 A fused 1 DP11 m 1 DP11 m Standard 1 A 4 7 fused 1 DP127 m 1 DP127 m Low noise / clean earth 2 A unfused 16 mm Ø CE, L, N, PE 1 JP22 m 1 JP22 m Low noise / clean earth 1 A fused 16 mm Ø CE, L, N, PE 1 JP21 m 1 JP21 m Low noise / clean earth 1 A 4 7 fused 16 mm Ø CE, L, N, PE 1 JP227 m 1 JP227 m Dual circuit 2 A unfused 20 mm Ø CE, L1, N1, L2, N2,PE 1 KP28 m 1 KP28 m 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 12

Electrak 27 powertrack / underfloor busbar system phase system (grey) NF4010 NW4010 - - -/- - - NA412 NZ41 Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Track system components Pack Cat. Nos. Tap-off units Electrak 27 phase track lengths Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 NA412 1 2 m, 4 outlets, 2 floor fixing brackets 1 NA418 1 8 m, 6 outlets, 2 floor fixing brackets 1 NA424 2 4 m, 8 outlets, 2 floor fixing brackets 1 NA46 6 m, 12 outlets, floor fixing brackets Track feed unit 1 NF4010 With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 NW4000 Excluding cables and conduit 1 NW4010 1 2 m flexible metal conduit 1 NW4020 2 4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ120 For fitting under integral track connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 2 A 2 A 41 V phase 20 mm Ø L1, L2, L, N, PE 1 NZ41 m 1 NZ41 m 2 A L1 2 unfused Reconfigurable live pin 1 NP42 m 1 NP42 m 2 A L2 2 unfused Reconfigurable live pin 1 NP402 m 1 NP402 m 2 A L 2 unfused Reconfigurable live pin 1 NP40 m 1 NP40 m Tap-off units specifically for the U.A.E. To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits, minimum 4 mm 2 conductors and use RYB colour coding for the conductors 2 A unfused 1 NP42R m L1 U.A.E. (R) 1 NP42R m L1 U.A.E. (R) 1 NP402Y m L2 U.A.E. (Y) 1 NP402Y m L2 U.A.E. (Y) 1 NP40B m L U.A.E. (B) 1 NP40B m L U.A.E. (B) 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 2 : All NP tap-offs are reconfigurable between L1, L2, or L for phase track 1

Electrak 28 powertrack / underfloor busbar system auxiliary earth system (red) YF010 YW010 - - -/- - - YA12 YP2 Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Track system components Pack Cat. Nos. Tap-off units Electrak 28 auxiliary earth track lengths Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 YA12 1 2 m, 4 outlets, 2 floor fixing brackets 1 YA18 1 8 m, 6 outlets, 2 floor fixing brackets 1 YA24 2 4 m, 8 outlets, 2 floor fixing brackets 1 YA6 6 m, 12 outlets, floor fixing brackets Track feed unit 1 YF010 With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 YW000 Excluding cables and conduit 1 YW010 1 2 m flexible metal conduit 1 YW020 2 4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ120 For fitting under integral track connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 2 A 2 A unfused 1 YP2 m 1 YP2 m 1 A fused 1 YP1 m 1 YP1 m 1 A 4 7 fused - high integrity 1 YP27 m 1 YP27 m 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 14

Electrak tinned powertrack... Designed to meet local standards As a specific requirement for use within Abu Dhabi, Legrand has developed a tinned busbar which has been designed in line with the guidance for busways outlined by the Abu Dhabi Distribution Company (ADDC), as detailed below. Guideline For Design, Testing and Installation Of Busways GL.GN.01. Issued by: Abu Dhabi Distribution Co. Low Voltage Switchgear Committee Issue: 2, Revision: 1, effective 01/02/2012 16. Lighting & Small Power Busways & Modular Wiring Lighting & Power Socket bus duct and modular wiring are considered part of building wiring and regulated by the Electricity Wiring Regulation issued by RSB. It shall comply with respective specifications under the Wiring regulation. ADDC LVSGC approves these methods in principle provided that the RSB set aspects are incorporated (like tinning of copper, colour coding etc.). Guideline For Design, Testing and Installation Of Busways GL.GN.01 Copyright Abu Dhabi Distribution Co. Developed to meet the ADDC requirements for busways, these specially designed ranges see all busbars tinned along their entire length, and all busbar connectors and tap-off blades plated. Approved to ASTA standard 18 and designed to be in accordance with the requirements of BS EN 6049-2: 2000 and BS EN 614-22: 2009 (IEC 614: 2009). The Electrical Wiring Regulations 2007 Issued by: The Regulation and Supervision Bureau for the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi. Revision 1, January 2009 7.7 Busways, bus ducts and busbar risers 7.7.6 Busways, bus ducts and busbar risers shall have neutral conductors of equal size to the phase conductors and shall have a dedicated Earth Conductor. The use of the metal casing as an earth conductor permitted only for Earth Leakage Protected Installations, and with the prior approval of the Distribution Company. The Electrical Wiring Regulations 2007 Copyright The Regulation and Supervision Bureau (RSB) The Electrak powertrack system uses equal size tinned copper busbars for live, neutral and earth conductors to meet with the requirements of The Regulation and Supervision Bureau of the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi. Electrak 28R tinned tap-offs Electrak 28R tinned busbar connectors Appendix 8. Colour identification for cables Conductor Colour Non-flexible fixed wiring and all phase cables: Phase 1 Red Phase 2 Phase Neutral Earth conductors Yellow Blue Black Green / yellow To meet the local regulations, tap-offs designed for sale within this region are supplied with the following cable colours: Within any single phase system (e.g. Electrak 2R or Electrak 28R) - red (L), black (N) and green/yellow (E). Specifically within the phase Electrak 27 system - L1 tapoffs are red (L), black (N) and green/yellow (E); L2 tap-offs are yellow (L), black (N) and green/yellow (E); L tap-offs are blue (L), black (N) and green/yellow (E). Appendix 9. Capacity of conduits and trunking Conduit (mm 2 ) 1. 2. 4.0 Diameter of Conduit (mm 2 ) 20 2 2 Maximum number of conductors 7 12 - The tap-offs contain a maximum of 2 x 4mm 2 conductors (excluding earths) housed in a 20mm ø metal flexible conduit. NOTE: When designing installation in regions with higher ambient temperatures than ºC, de-rating factors may need to be applied. Please refer to the table on page 22 for details. 9 6 12 9 1

Electrak 2R tinned powertrack / underfloor busbar system low noise / clean earth system (green) JF2010R JW2010R - - -/- - - JA212R JP22R Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Busbar system components Pack Cat. Nos. Tap-off units 6 A low noise / clean earth busbar lengths Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 JA212R 1 2 m, 4 outlets, 2 floor fixing brackets 1 JA218R 1 8 m, 6 outlets, 2 floor fixing brackets 1 JA224R 2 4 m, 8 outlets, 2 floor fixing brackets 1 JA26R 6 m, 12 outlets, floor fixing brackets Feed unit 1 JF2010R With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 JW2000R Excluding cables and conduit 1 JW2010R 1 2 m flexible metal conduit 1 JW2020R 2 4 m flexible metal conduit Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ120 For fitting under integral connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 2 A 2 A unfused 20 mm Ø CE, L, N, PE (4 mm 2 ) 1 JP22R m 1 JP22R m 1 A fused - high integrity 20 mm Ø CE, L, N, PE (4 mm 2 ) 1 JP214R m 1 JP214R m 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 16

Electrak 28R tinned powertrack / underfloor busbar system auxiliary earth system (red) YF010R YW010R - - -/- - - YA12R YP2R Selection charts p. 8-9 Dimensions and technical information p. 18-2 Approved to ASTA Standard 18 and ISO 9001 : 2008 Conforms to BS EN 614-22 : 2014. Fully complies with the requirements of BS 7671 : 2008 + AMD : 201 IET Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm Pack Cat. Nos. Busbar system components Pack Cat. Nos. Tap-off units 6 A auxiliary earth busbar lengths Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 00 mm socket centres 1 YA12R 1 2 m, 4 outlets, 2 floor fixing brackets 1 YA18R 1 8 m, 6 outlets, 2 floor fixing brackets 1 YA24R 2 4 m, 8 outlets, 2 floor fixing brackets 1 YA6R 6 m, 12 outlets, floor fixing brackets Feed unit 1 YF010R With one 2 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks Can be used to overcome obstructions or as corners where required 1 YW000R Excluding cables and conduit 1 YW010R 1 2 m flexible metal conduit 1 YW020R 2 4 m flexible metal conduit Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ120 For fitting under integral connectors Tap-off length is determined by the cable and not the conduit length, e.g. a m tap-off has m of cable and 2 6 m of flexible metal conduit 1 Tap-off units in excess of m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 2 A 2 A unfused 20 mm Ø L, N, PE (4 mm 2 ) 1 YP2R m 1 YP2R m 1 A fused - high integrity 20 mm Ø L, N, PE (4 mm 2 ) 1 YP14R m 1 YP14R m 1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 4 600 6266 17

Electrak powertrack / underfloor busbar system design and installation n General installation notes Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm Feed units are provided with one or two 2 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Track lengths connect together and to feed units using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets ; three on the 6 m length and two on 2 4 m, 1 8 m or 1 2 m lengths n Special fixing brackets Electrak special fixing brackets are available to raise the system by 21 mm. Ensure brackets are spaced 600 mm apart and always have support under the integral connectors and feed units. Failure to do so may undermine the integrity of the system Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm centres along the busbar run. Also use bottom half of bracket under feed unit and flexible interlink Cat. No. DZ120 raised off-floor fixing brackets are always used under integral connectors. Busbar is secured to raised brackets using the integral fixing bracket Access to power is provided along the busbar length by simply plugging tap-off units into shuttered socket outlets. These tap-off units feed all types of conventional floor service outlet boxes or feed workstations directly through the floor via insulated conductors contained in flexible metal or VO rated nylon conduit. When connecting tap-offs directly through the floor via grommet outlets to workstations care must be taken to ensure that the tap-off length is adequate The dual system has both standard and low noise / clean earth systems incorporated. As well as dual tap-offs, both standard and low noise / clean earth tap-offs can be plugged into any socket outlet along the busbar length. The dual tap-off incorporates both standard and low noise cables Optimum layout flexibility is achieved by positioning busbar lengths a maximum of 2 m apart and 2 m from the wall, and by connecting the m tap-off units to floor outlet boxes. This means every part of the floor area can be served. Flexible interlinks can be used to overcome obstructions or used as corners if required 99 mm 0 mm Cat. No. DZ1210 7 mm Ø Integral connector 21 mm to underside and 6 mm to top of busbar length Integral fixing bracket screws to special bracket 18 mm Cat. No. DZ120 7 mm Ø n Dimensions 9 7 20 109 118 68 46 46 47 2 1 2 x 2 Ø 2 Ø 6 End view A End view B 92 Integral fixing bracket fixing centres Example floor layout 2 m 2 m socket outlet points every 00 or 600 mm along busbar run 2 m m flexible tap-off unit floor service outlet box feed unit 2 m integral connectors All dimensions (mm) are nominal 18

n Product configuration Flexible interlink Tap-off connection Flexible interlink boxes must be securely fixed inline to surface so no movement can take place after fixing Depress tap-off side clips and push down Tap-off Push down Side clip Remove dust cover from end entry socket before use Interlink feed entry socket. Remove dust cover label Make sure both tapoff side clips are fully pushed home on both sides of tthe bar Screw fix to surface Feed unit (Cat. No. DF1010) Sub-cabling Tap-off connection Feed unit protective earth terminal and earth bond Tap-off metal flexible conduit Connector terminals Protective earth must always be connected via the earth terminal block Lift lid 20 mm Ø conduit fitting. Tighten back nut securely Lift terminal tab to access terminal screws and close after use 2 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up Feed unit (Cat. No. JF2010 and JF2010R) Sub-cabling Feed unit protective earth terminal and earth bond Tap-off connection Tap-off metal flexible conduit Connector terminals Protective earth must always be connected via the earth terminal block Lift lid 20 mm Ø conduit fitting Tighten back nut securely Lift terminal tab to access terminal screws and close after use Clean earth 2 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up All dimensions (mm) are nominal 19

Electrak powertrack / underfloor busbar system design and installation (continued) n Product configuration (continued) Feed unit (Cat. No. KF010) Sub-cabling Lift terminal tab to access terminal screws and close after use Dual tap-off connection (dark green) Tap-off metal flexible conduit Protective earth must always be connected via the earth terminal block Feed unit protective earth terminal and earth bond Lift lid 20 mm Ø conduit fitting Tighten back nut securely Connections L1, N1, CE = low noise L2, N2, PE = standard Connections L1, N1, CE = low noise L2, N2, PE = standard Connector terminals Clean earth 2 x 2 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up Feed unit (Cat. No. NF4010) Sub-cabling Feed unit protective earth terminal and earth bond phase tap-off connection Tap-off metal flexible conduit Protective earth must always be connected via the earth terminal block Lift lid 20 mm Ø conduit fitting Tighten back nut securely Connector terminals Lift terminal tab to access terminal screws and close after use 2 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up Feed unit (Cat. No. YF010 and YF010R) Sub-cabling Feed unit protective earth terminal and earth bond Tap-off connection Tap-off metal flexible conduit Connector terminals Protective earth must always be connected via the earth terminal block Lift lid 20 mm Ø conduit fitting Tighten back nut securely Lift terminal tab to access terminal screws and close after use 2 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up All dimensions (mm) are nominal 20

Electrak powertrack / underfloor busbar system installation (continued) 1 Fix feed unit to surface Feed unit Direction of busbar run Make chalk line to align busbar lengths 2 Connect busbar length to feed unit Remove dust cover Integral connector Busbar length Push down Feed unit Make sure connector clips are fully pushed home on both sides Push down Additional length Connect additional busbar lengths Remove dust cover before connecting additional lengths First fixing bracket Tap-off outlets reusable plastic dust covers 4 Secure busbar lengths to surface Pull out fixing bracket lugs and screw fix on both sides All integral fixing brackets must be fixed to surface at 1 2 m fixing centres from first bracket on each busbar length All dimensions (mm) are nominal 21

Electrak powertrack / underfloor busbar system technical data n Standards Approved to ASTA Standard 18 BS EN 614-22 : 2014 and IEC 614-22 : 2014 Manufactured within an approved ISO 9001 : 2008 and ISO 14001 : 2004 facility Assessed Quality Assurance Certificate No. 2029 Electrak powertrack / underfloor busbar fully complies with the requirements of BS 7671 : 2008 + AMD : 201 (IET Wiring Regulations) n Ambient temperature rating factors The current carrying capacity for a powertrack / underfloor busbar (In) is affected by the ambient temperature For Electrak powertrack / underfloor busbar the ambient rating factor Ka is equal to 1 for ambient temperatures up to and including C Iz = Ka In Where : Iz = effective current carrying capacity for continuous service under particular installation conditions Ka = ambient temperature factor In = nominal current carrying capacity For ambient temperatures exceeding C the values of Ka and Iz are given in the following tables Powertrack / underfloor busbar system Ambient 20 C 2 C 0 C C 40 C 4 C 0 C Ka 1 0 9 0 8 0 80 Iz 6 A 9 A A 0 A 2 A unfused tap-off (using thermosetting 90 C cables) Ambient 20 C 2 C 0 C C 40 C 4 C 0 C Ka 1 0 9 0 8 0 80 Iz 2 A 0 A 27 A 2 A 1 A fused tap-off (using 2 mm 2 thermosetting 90 C cables) Ambient 20 C 2 C 0 C C 40 C 4 C 0 C Ka 1 Iz 1 A n Earth fault loop impedance BS 7671 : 2008 + AMD : 201 IET Wiring Regulations require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0 4 seconds. The values relevant to Electrak for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite n Durability Electrak systems are superbly designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak powertrack / underfloor busbar has been short circuit strength tested by ASTA n Installations with high protective conductor currents All unfused tap-offs comply with Regulation 4 7 without the need for additional earth conductors. Regulation 4 7 1 10 (ii) states a single copper protective conductor having a cross-sectional area of not less than 4 mm 2, complying with the requirements of Regulations 4 2 and 4, the protective conductor being enclosed to provide additional protection against mechanical damage, for example, within a flexible conduit For installations with high protective conductor currents requiring fused tap-offs, a 4 7 compliant tap-off must be used. Normally fused tap-offs incorporate 1 mm 2 conductors, however in our fused 4 7 tap-offs, the 1 mm 2 earth conductor is replaced with a 4 mm 2 conductor and are therefore compliant with Section 4 7 1 10 (ii) n 2 A tap-off unit The m 2 A tap-off unit comprises an unfused tap-off with 2 6 m of flexible metal conduit with integral 4 mm 2 LSOH conductors These units are designed to comply with regulation 44 2 1 of the IET Wiring Regulations by virtue of the following : maximum length of cable is m it is factory assembled and fully tested item with cable installed in high quality flexible conduit Fault condition protection for the tap-off assembly and the floor box socket outlets is delivered by the circuit protection device Disconnection time for socket outlets is 0 4 seconds (Regulation 411 2 2). The Electrak system meets this requirement Tap-off units in excess of m should only be used if they contain a fuse or the busbar run is protected by a protective device not exceeding 2 A References : BS 7671 : 2008 incorporating amendment No. : 201 Appendix 8 Current carrying capacity for powertrack systems Appendix 4 Table 4B1 Rating factors for thermosetting cables Appendix 4 Table 4E1A Single core 90 C thermosetting insulated cables (non-armoured) All dimensions (mm) are nominal 22

Volt drops (live and neutral) Busbars 0 mv/a/m Cable connector 0 4 mv/a Integral connector 0 4 mv/a 2 A tap-off 0 4 mv/a + 4 mm 2 cable 11 mv/a/m Flexible corner assembly 1 mv/a + 10 mm 2 cable 4 0 mv/a/m Mechanical data E24 E28 E28R Number of conductors -6 Busbar conductor cross sectional area 1 mm 2 1 mm 2 Housing cross sectional area (copper equivalent) 1 mm 2 1 mm 2 Cable terminal capacity 16 mm 2 16 mm 2 Tap-off cable 2 A 4 mm 2 4 mm 2 Tap-off cable 1 A fused 1 mm 2 2 mm 2 Tap-off conduit, up to 4 conductors 16 mmø 20 mmø Tap-off conduit, and 6 conductors 20 mm 2 N/A Flexible corner cable (tri-rated, high temperature) 10 mm 2 10 mm 2 Flexible corner conduit 2 mmø 2 mmø IP rating 40 40 Earth fault loop impedance Phase busbar 1 mω/m Earth busbar 1 mω/m Earth housing 1 1 mω/m Earth busbar and housing 0 8 mω/m Cable connector 0 4 mω Integral connector 0 6 mω 2 A tap-off 0 6 mω + 4 mm 2 cable 11 mω/m Flexible corner assembly 1 mω + 10 mm 2 cable 4 0 mω/m Rated conditional short-circuit current 16 KA Ambient temperature 2 C Electrical test data Rated current 6 A Rated voltage 20/400 V~ Frequency 0/60 Hz Conductor resistance - live and neutral 0 mω/m Conductor impedance 1 mω/m Material specifications Housing - busbar lengths Galvanised steel, natural finish Busbars High conductivity copper (Tinned version is electro-tin plated) Busbar insulator PTFE Integral connectors / Tap-off outlets Flame retardant polycarbonate Tap-off outlet entry shutter Acetal Tap-off housing Flame retardant polycarbonate Integral connector blades Copper (Tinned version is plated) Tap-off blades Copper (Tinned version is plated) Tap-off/flexible corner conduit, metal Electro-galvanised steel Tap-off cable LSOH to BS 7211 Flexible interlink cable Tri-rated to BS 621 Feed box/flexible interlink boxes Galvanised steel Feed connector terminals/earth block Brass (Tinned version is plated) Fixing brackets Galvanised steel 1 A tap-off, fuse To BS 162, ASTA approved All dimensions (mm) are nominal 2