Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

Similar documents
Wastewater Solutions

Switch rated plugs and receptacles with nema 4X protection

DSN. Switch-rated plug and receptacle with Type 4X protection

Switch rated plugs and receptacles

NFPA 70E 68! & CSA Z462

Robust construction and high amperage capabilities

POWER GENERATION SWITCH RATED ELECTRICAL CONNECTORS FOR INDUSTRY. hyconelec.co.za MARECHAL TECHNOLOGY

SWITCH-RATED = + Plugs & Receptacles THE MAIN DIFFERENCES. DECONTACTOR TM Technology. Switch and Hp Ratings. Short Circuit Ratings

Robust construction and high amperage capabilities

DS Switch-Rated. plug and receptacle. Main Advantages. DS100 p. 48 DS200 p. 50 Spare parts p. 52 Dimensions p. 54

Plugs, Receptacles & Connectors

WATER & WASTE WATER INDUSTRIES

Switch rated connectors for. Ports, Shipyards & Vessels

PORTS, MARINAS, SHIPYARDS & VESSELS

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 132 PF/PFQ A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p.

Technical Manual TYPE 4X

MAIN OPTIONS DESCRIPTION OF THE KEY OPTIONS OF OUR PRODUCTS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p.

Receptacles & Wall Boxes with Integral Circuit Protection

THE ADVANTAGES OF BUTT CONTACTS

SWITCH SHOULD BE ON THE UPPER SIDE!

SWITCH SHOULD BE ON THE UPPER SIDE!

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

BAC Custom Engineered Controls

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Now - Up To 400A Mains!

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Receptacles & Wall Boxes with Integral Circuit Protection

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Selection Guide Motor Control Device Solutions

OTEC Transfer switch open transition

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

General information about motor protection

Application Description

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Transfer switch OTEC and OTECSE open transition

Product guide. Enclosed NEMA starters. Answers for industry.

Specification made simple for selective coordination in a compact size

Product Guide. enclosed NEMA STARTERS

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Quik-Spec Electrical Gear

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Design Standard. Purpose: Design Standard:

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

A Safety-First Priority

Product Specification Sheet #3LD2.1

Bussmann series Quik-Spec Coordination Panelboard

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

Arrow Hart. environment devices. Watertight, severe duty and corrosion resistant devices for harsh industrial environments

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Quik-Spec. Section Contents

AC Switches: ML & MN Series DC Switches: MDC1A Series

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

Bolted contact switches. Pringle switches

UL 508 Non-Fusible Disconnect Switches

SD Series Non-Fused Load Switches

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Switches & Motor Controls

Product Guide. NEMA pump controls.

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

IEC 309 Plugs, Connectors, Receptacles, and Inlets

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

UL 508 Non-Fusible Disconnect Switches

Safety Alert: Square D Safety Switches

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Solar Combiner Solutions

Compact Circuit Protector (CCP) Application Note

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

Aluminum Vertical Break Switch kv A.

HEAVY-DUTY PLUGS & SOCKETS

Products for. Section

INDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Transcription:

Wastewater Solutions Featuring Meltric s DECONTACTOR TM Series Switch Rated Plugs, Receptacles and Electrical Connectors

Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors are a combination plug and receptacle and disconnect switch in the same device. In addition to providing a safe and convenient electrical connection, they also provide the NEC required line of sight disconnect. They allow users to safely and easily make and break electrical connections even under full load. Using Meltric Decontactors to connect motors instead of hard-wiring can help reduce motor change-out downtime by as much as 50%. Connection to an Anaerobic Basin Mixer Remote Lift Station Primary Air Compressor Simplify Maintenance Decontactors allow mixers and other equipment to be safely connected with plug and play simplicity. Mechanics can easily replace or service equipment without needing an electrician on site and without the need for electrical PPE, as required by NFPA 70E. Equipment change-out times are significantly reduced, worker exposure to harsh environments is minimized, and re-wiring errors are eliminated (no more motors running backwards). Simplify NEC Code Compliance Using Decontactors to connect pumps, grinders (shown) or other equipment, automatically provides the NEC required line of sight disconnect. The installation of Decontactors is a simple and cost effective means of achieving code compliance on new or existing installations. Decontactors function as a local disconnect and provide positive visual verification that power is off. The need and expense of a separate disconnect switch is eliminated. 2

Ideally Suited for the Wastewater Industry Decontactors are built with materials that withstand the harsh environment of wastewater treatment plants. For example, Meltric s silver-nickel contacts, stainless steel hardware, and chemical resistant housings help withstand corrosion caused by the hydrogen sulfide gases often found in wastewater environments. Other features, such as optional auxiliary pilot contacts, help make the operation of a wastewater plant safer and more efficient by allowing electrical interlocking with a motor starter and by simplifying the monitoring of key parameters that may indicate thermal alarms or seal failures. Connection to a Sludge Mixer in a Holding Tank Connections to Submersible Pumps for Effluent Water Provide Durable Connections Decontactors are ideal for connecting submersible pumps in both indoor and outdoor applications. Their spring-loaded, silver-nickel butt-style contacts provide consistently superior electrical performance over thousands of operations and are resistant to wear, corrosion, oxidation, and other factors that contribute.to the premature failure of pin & sleeve devices. They also feature a patented, spring assisted, screw terminal design that helps prevent connections from loosening over time due to conductor yield and vibration. Ensure Safety for Maintenance Personnel In addition to the safety benefit inherent in the contact design, all Decontactors have dead front construction, enclosed arc chambers and short circuit make and withstand ratings of at least 65kA. The dead front prevents user access to live parts and the short circuit rating ensures safety during insertion, even under overload or locked rotor conditions. Decontactors eliminate the safety hazards associated with pin & sleeve devices. 3

Benefit from Meltric Connectors... Meltric Switch Rated Plugs, Receptacles and Connectors are ideal for connecting power to... Pumps Mixers Aerators Portable Motor Grinders Compressors Generators Control Centers 4

...Throughout Your Plant Application Spotlight: Submersible Mixers Submersible mixers and pumps are used throughout a typical wastewater treatment plant, as well as, at remote lift stations. When used to connect power to submersible mixers or pumps, Meltric Decontactors offer.. Safety Workers can safely make and break electrical connections under full load. The dead front prevents access to live parts. Meltric DECONTACTOR Easy Equipment Change-outs A technician can break the power, service or replace the mixer, and reconnect power. There is no need for an electrician on site. Low Costs Decontactors are UL, CSA, and IEC switch rated. You effectively get a disconnect switch for free. Design and Installation Simplicity There is no need to locate and install auxiliary disconnect switches or mechanical interlocks. Long Life Robust materials and construction resist harsh environments. Butt-style contacts perform for thousands of operations. Extended Functionality Optional auxiliary pilot contacts allow facilities to easily interlock with motor starters and monitor key parameters, such as, thermal alarm or seal failure. Submersible mixer connections at a BNR process basin Typical submersible mixer application Simple and Safe Operation 1 2 3 4 When the plug and receptacle are latched together, the circuit is connected. Pressing the pawl causes the DECONTACTOR to break the circuit. The plug is ejected to its rest position; its contacts are now dead. Rotating the dead plug 30 counterclockwise closes the safety shutter and frees the plug to be withdrawn from the receptacle. The plug and the receptacle are separated. The safety shutter prevents access to live parts. 5

Meltric DECONTACTOR TM Series Plugs and Receptacles DSN pictured Spring-Assisted Screw Terminals Patented design assures Tighten and Forget confidence. Spring-Loaded Butt Style Contacts Ensures consistent contact force over thousands of operations. Receptacle Lid Provides additional protection from harsh environments. Durable Casings Pushbutton Pawl Provides quick, safe and easy load break. Dead Front Assures safety by preventing user access to live parts. Offers great resistance to impact and harsh environmental conditions. Allows easy NEC, CSA and NFPA 70E code compliance Functions as a line of sight disconnect switch Safely makes and breaks resistive or inductive loads Lockout-Tagout Provisions Allows plug to be easily locked out and tagged. Optional padlock pawl allows lockout/tagout of the receptacle. Silver-Nickel Contacts Silver-Nickel material provides superior conductivity, durability and corrosion resistance. DSN 20-60A DS 20-200A DB 30-100A Compact, lightweight design NEMA 4X, IP 66/67 Up to 4 auxiliary contacts Polyester casings 100kA + short circuit rated Rugged construction NEMA 3R Up to 5 auxiliary contacts Polyester or Metal casings 65kA + short circuit rated High horsepower capacity IP 67 Up to 4 auxiliary contacts Zinc aluminum alloy casings 100kA + short circuit rated + Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp ratings, except for DB100 which was tested with 250A fuses. Non-horsepower rated DS100 and DS200 devices were tested with RK5 time delay fuses sized at 100% of the devices rated ampacity. Tested to a Higher Standard Meltric Decontactors are the world s only UL and CSA switch rated plugs and receptacles. Not only do they meet performance test requirements for UL 1682/CSA C22.2 No. 182.1 (to which competitive pin and sleeve devices are listed), but Decontactors also meet the performance test requirements in UL Subject 2682 Switch-Rated Plugs and Receptacles. Based on their evaluation against this standard, Decontactors are UL and CSA listed for use in motor circuit disconnect/switching applications and in branch circuit disconnect/switching applications. Tests passed by Meltric Decontactors and by traditional pin and sleeve type plugs and receptacles (per UL 1682 and CSA 22.2 No. 182.1) Temperature Rise (not to exceed 30 C over ambient) 50 operations @ 150% device rating and.7 -.8 power factor Endurance - number of operations @.75 -.8 power factor 20A 5,000 under load 0 off load 30 to 60A 1,000 under load 1,000 off load 100 to 200A 250 under load 250 off load Additional Tests passed exclusively by DECONTACTOR TM Series plugs and receptacles per UL Subject 2682. 50 operations @ 6x motor FLA.4 -.5 power factor 6,000 operations @ FLA.75 -.8 power factor Short circuit make and withstand @ 65kA, 600V and <.15 PF Additional Listings include: IEC/EN 60309-1, 60947-3, AS 3123 6

Product Technology & Specifications Safety & Code Compliance: Meltric vs the Competition MOTOR HARD-WIRED TO A BLADED DISCONNECT SWITCH Disconnect may be difficult to install in line of sight from the motor MOTOR CHANGE-OUT PROCESS 1. Electrician opens disconnect switch 2. Determine PPE requirements and obtain 3. Remove disconnect cover 4. Voltmeter test to verify deenergization 5. Apply lockout/tagout 6. Disconnect motor from hard-wiring 7. Mechanic removes old/installs new motor 8. Electrician connects motor to hard-wiring 18 Qualified Worker w/ppe MOTOR CONNECTED WITH A MELTRIC MOTOR PLUG OR OR Cord connection allows easy line of sight area Dead front eliminates access to live parts, so there is no need for PPE Ability to safely make & break under load eliminates the need for interlocks 65kA short circuit make & withstand rating ensures safety during reenergization MOTOR CHANGE-OUT PROCESS 1. Mechanic removes plug from receptacle 2. Apply lockout/tagout as required 3. Mechanic removes old/installs new motor 4. Mechanic inserts plug into receptacle Meltric Makes it Safe & Easy MOTOR CONNECTED WITH A COMPETITIVE PLUG & RECEPTACLE Expensive mechanical interlocks are required since these plugs & receptacles cannot safely make & break under load The interlock must be mounted on a fixed surface-this may make line of sight location more difficult MOTOR CHANGE-OUT PROCESS 1. Open interlock switch 2. Determine PPE requirements & obtain 3. Remove interlock cover 4. Voltmeter test to verify deenergization 5. Remove plug 6. Apply lockout/tagout as required 7. Remove old/install new motor 8. Insert plug into receptacle Product Selection Guide Model Casing Maximum Voltage Amperage Maximum Number of Contacts Environmental Material (VAC) Rating Main Auxiliary Rating Maximum Horsepower Rating 480VAC 600VAC DSN20 Poly 480VAC 20A 3P+N+E - NEMA 4X IP66/ 67 5 hp na DSN30 Poly 600VAC 30A 3P+N+E 2 NEMA 4X IP66/ 67 10 hp 15 hp DSN60 Poly 600VAC 60A 3P+N+E 4 NEMA 4X IP66/ 67 20 hp 20 hp DS20 Poly 600VAC 20A 3P+N+E 2 NEMA 3R 5 hp 7.5 hp DS30 Poly 600VAC 30A 3P+N+E 4 NEMA 3R 10 hp 10 hp DS60 Poly or Metal 600VAC 60A 3P+N+E 3 NEMA 3R 20 hp 25 hp DS100C Poly or Metal 600VAC 100A 3P+N+E 3 NEMA 3R 20 hp 25 hp DS100 Poly or Metal 600VAC 100A 3P+N+E 5 NEMA 3R - DS200 Metal 480VAC 200A 3P+N+E 5 NEMA 3R - DB30 Zinc Aluminum 600VAC 30A 3P+N+E 2 IP67 10 hp 10 hp DB60 Zinc Aluminum 600VAC 60A 3P+N+E 2 IP67 30 hp 30 hp DB100 Zinc Aluminum 600VAC 100A 3P+N+E 4 IP67 60 hp 60 hp * Consult the Meltric catalog for horsepower ratings at other voltages. 7

More Products & Services for the Wastewater Industry Other Meltric Products Commonly Used in Wastewater Facilities Multipin Plugs and Connectors Multipin products are commonly used in power and control applications. They are available with up to 37 contacts and have a total amp capacity ranging from 5 to 100A. DS7 models facilitate star-delta motor starting. DXN Hazardous Duty Connectors DXN s are CSA listed for Class 1 Division 2 and Class 2 Division 2 environments. Suitable for loads up to 60A, DXN s provide a compact, waterproof solution for potentially hazardous locations. Common Options Used in Wastewater Facilities Auxiliary Pilot Contacts Lockable Plugs or Receptacles Pilot Contacts Pilot contacts are available for operating secondary control circuits or for electrical interlocking with motor starters. Theses contacts make last and break first when the plug is engaged or disengaged. Two to five auxiliary contacts are available on Decontactors. Padlockable Pawl Locking device not included Padlockable Plug Cap DSN Plug Padlockable pawls and plug caps are available for preventing unwanted connection or disconnection of plugs. Padlockable pawls also allow the lid to be locked closed. Padlockable plug caps provide up to NEMA 4X watertightness. Meltric Service Replacement Parts Same Day Shipping Five Year Warranty The need to replace parts is rare. However, should they be required, parts are readily available and reasonably priced. Purchasing the individual parts costs no more that buying an assembled product. Due to the modular design of our product and efficient customer service and factory operations, 90% of our orders are shipped by the next day. For a small fee, orders can be shipped the same day. The electrical contacts on Meltric products are warranted for five years from date of shipment. The complete product is warranted for one year from the date of shipment. Contact Meltric for a full warranty statement. Presented by Meltric and: 4640 Ironwood Drive Franklin, WI 53132 800.433.7642 Fax 414.817.6161 www.meltric.com 8 WW SOLNS 050703 E