Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Similar documents
Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

CF270.UL.D.

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

CF11.LC / CF11.LC.D CF14.CAT5

14 HH EAC/CTP CE RoHS-II conform

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Data sheet chainflex CF881

Data sheet chainflex CF886

Data sheet chainflex CF886

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Data sheet chainflex CF8821

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF210.UL

DNV-GL HH CE RoHS-II conform

Data sheet chainflex CF240

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Data sheet chainflex CF885.PE

Data sheet chainflex CF310.UL

Data sheet chainflex CF6

Data sheet chainflex CF140.UL

Data sheet chainflex CFSOFT1

Data sheet chainflex CF5

Data sheet chainflex CF340

Data sheet chainflex CF300.UL.D

CFRIP - tear strip for faster stripping

Data sheet chainflex CF130.UL

Data sheet chainflex CF330.D

Data sheet chainflex CF10

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45

Data sheet chainflex CF113.D

Data sheet chainflex CF9

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/

Cables up to CAT7.

Cables up to CAT7.

Cables up to CAT7.

chainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/

chainflex cables with DNV-GL certification ndustry plastics for longer life

Chainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables

Special cables. Guarantee. Special cables

chainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/

Guarantee. Special cables

chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Special cables. chainflex Typees. chainflex

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

chainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Technical Data Sheet Shielded (CY) PVC Control Cable

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

Technical Data Sheet Shielded (CY) PVC Control Cable

Cables for Railway Technology

INFORMATION. Hybrid cables. Description

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

ÖLFLEX CLASSIC 115 CY

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

Test-Order chainflex

PVC motor cables unshielded

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

Telephone Cables Fire Warning Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

ÖLFLEX CLASSIC 110 CY

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

PRODUCT INFORMATION H07V-K

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Cables for cable carriers and reels SYSTEMS IN MOTION

CRANE, CONVEYOR, LIFT & REELING CABLES

PUR c-track cables For highest requirements

Power & Control Cable IEC

ÖLFLEX CLASSIC 110 H Info Benefits

Chemical resistance Accidental

MOTOR, SERVO, & FEEDBACK CABLES

6000 Series Ethernet Buccaneer

20 HUBER+SUHNER RADOX SOLAR

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Technical attributes

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

H05 V-K PVC-Single Cores, fine wire stranded

Cable Assemblies according to Bosch Rexroth Standard

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Caledonian Flame Retardant RS485 Databus Cables

Transcription:

Overview Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF898.001 CF898.045 CF898.080 & CF898.081 Example drawing 34 mm Core design: Conductor: Core insulation: Core identification: Shield design: (Not relevant for 080 & 081) Material: Shield coverage (optical): Wire strand consisting of bare or (following DIN EN 60228). According to bus specification. According to bus specification. Braid made of combined with an aluminium clad plastic foil. approx. 60 % (Braid) 100 % (Foil) Jacket design: Outer jacket: Low-adhesion mixture on the basis of igupur adapted to suit the requirements in e-chains. oil-resistant (following DIN EN 50363-10-2) flame-retardant (following IEC 60332-1-2, CEI 20-35, VW-1 & FT-1 (001 & 045)) FT-2 (080 & 081)) silicon-free (following PV 3.10.7 - status 1992) lead-free (following 2011/65/EU (RoHS-II)) UV-resistance: Medium Colour outer jacket: Red lilac (similar to RAL 4001) or Rape yellow (similar RAL 1021) (only CF898.080) or Jet black (similar RAL 9005) (only CF898.081) Cable marking (Black or White): 00000 m * igus chainflex M CF898.--- --- --- CE --- --- conform General mechanical values: (for individual details see technical table) RoHS-II conform +++ chainflex cable works +++ * Length printing: Not calibrated. Only intended as an orientation aid. / : Cable identification according to part no. (see technical table. Ex.: CF898.001: chainflex CF898.001 (2x0,25)C CE : Printing of the data (see related chapter). : Printing: DESINA (only if DESINA-standard fulfilled). : Printing according to bus specification (inclusive wave resistance). Ex.: CF898.001: DESINA 150 OHM Profibus conform Double strokes 1 million Temperature Travel distance Min. bending radius for e-chain use [Factor multiplied by outer diameter (d)] (from/to) [ C] (TD) (Ex.: CF898.001 at 20 C: 15,0 x 8,0 mm Min. bending radius 120,0 mm) -20 / -10 17,5 (17,5 x h ) 6 m -10 / +70 (unsupported) 15,0 (15,0 x h ) +70 / +80 17,5 (17,5 x h ) : Minimum guarantee lifetime of the cable under the specified conditions. The installation of the cable is recommended within the middle temperature range. Temperature range -40 C -20 C -10 C +70 C +80 C Min. bending radius for fixed installation 15,0 x d (17,5 x h ) 12,5 x d (15,0 x h ) 10,0 x d (12,5 x h ) 12,5 x d (15,0 x h ) Torsion (at 1 m cable length) --- ±0 ±15 (±0 ) ±0 : Applicable values for.080 &.081 according to the height (h). Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 1/5

General electrical values: (for individual details see technical table and chapter belonging to the cable) Nominal voltage: 50 V Test voltage: 500 V (Core / Core) & 500 V (Core / Shield) following DIN EN 50289-1-3 Guidelines: CE, DESINA (not.080 &.081), NFPA (following 79-2012 chapter 12.9), EAC & TR (CTP) Dynamic values: Max. speed for e-chain use:** Gliding (up to 6 m): v = 3 m / s Max. acceleration for e-chain use:** a = 20 m / s 2 ** These values are based on specific applications or tests. They do not represent the limit of what is technically feasible. Typical lab test setup for this cable group: Test bending radius R: approx. 100 mm Test travel S: approx. 1-15 m Test period: min. 1,0-1,5 million double strokes Test speed: approx. 0,5-2 m / s Test acceleration: approx. 0,5-1,5 m / s 2 e-chain - Bus cable for flexible load requirements: for 1 million movements (double strokes) in e-chains for areas of application with oil influence especially for unsupported travel distances CE, RoHS-II, DESINA (only.080 &.081),, NFPA, EAC & TR (CTP) Typical application areas: Indoor and outdoor applications without direct sun radiation. Machining units/machine tools, low-temperature applications. Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 2/5

Technical tables: Mechanical values: Part no. Number of cores & nominal cross section [mm²] External diameter (d)*** [max. mm] Copper index [kg / km] Weight [kg / km] Profibus CF898.001 (2x0,25)C 8,0 19 58 Ethernet (CAT5e / GigE / PoE) CF898.045 (4x(2x0,15))C 7,5 27 64 ASinterface CF898.080 2x1,5 see drawing 32 64 CF898.081 2x1,5 see drawing 32 64 *** External diameters are maximum values and may tend toward lower tolerance limits. Nominal cross section [mm²] Conductor resistance [approx. Ω / km] at 20 C Max. current rating [A] at 30 C (following) DIN EN 50289-1-2 DIN VDE 0891-1 0,15 149 2,5 0,25 78 5 1,5 14,6 21 The max. current rating depends on factors such as the individual environmental conditions and the type of installation. Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 3/5

CF898.001 (Profibus) extruded igupur mixture Conductor: Wire strand consisting of bare copper wires Overall shield: Braid made of Filler: Plastic yarn Banding: Plastic foil Shield foil: Aluminium clad plastic foil Characteristic wave resistance: 150 ± 15 Ω ( 1 MHz) following DIN EN 50289-1-11 Certifications: : (E310776: Style 10493 & 20236, 300 V / 80 C) CF898.001 2x0,25 red, green CF898.045 (Ethernet (CAT5e / GigE / PoE)) extruded igupur mixture Overall shield: Braid made of 34 mm Conductor: Wire strand consisting of bare copper wires Characteristic wave resistance: 100 ± 15 Ω (at 1 MHz to 250 MHz) following DIN EN 50289-1-11 Certifications: : (E310776: Style 10493 & 20236, 300 V / 80 C) CF898.045 4x(2x0,15) whiteblue/blue, whiteorange/orange, whitegreen/green, whitebrown/brown (According to EIA/TIA 568) Banding: Plastic foil Shield foil: Aluminium clad plastic foil (Back to overview or technical table) Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 4/5

CF898.080 & CF898.081 (ASinterface) extruded PUR mixture Conductor: Wire strand consisting of 2 2 Elektrische Werte: All dimensions are in mm unless otherwise stated. These can due technical reasons tolerate up to ± 0,2 mm or ± 1 Nominal voltage: 50 V Test voltage: 1,5 kv (Core / Core) following DIN EN 50289-1-3 Certifications: : (E310776: Style 10493 & 20549, 300 V / 80 C) Operating capacity: CF898.080: approx. 80 pf / m CF898.081: approx. 80 pf / m (at 800 Hz) following DIN EN 50289-1-5 Characteristic wave resistance: 100 ± 30 Ω (at 167 khz) following DIN EN 50289-1-11 CF898.080 (Communications & Power Supply) 2x1,5 blue, brown CF898.081 (Auxiliary power supply) 2x1,5 blue, brown (Back to overview or technical table) Please refer regarding the availability of the items also the information in the latest chainflex catalogue. Page 5/5