Power drill Center punch Wire stripper

Similar documents
ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

7100SZ Series SafeZone Installation and Instruction Manual

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5600 Series Power Operator Installation and Instruction Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Installation Instructions Series 78-B/FHA Hold Open

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

TS93 EMF T/PT/TDE. Surface applied door closer

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

ASSA ABLOY Universal Door Closers

KEANE MONROE a member of the record group

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Installation Instructions CAUTION

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

5300 Series 5300 SERIES

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

CONCEALED CLOSER SERIES

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Installation Instructions (07-08) CAUTION

NON-SIZED SIZED HANDED

Door Controls DOOR CLOSERS

WARNING: Make sure that (120V, 60Hz) input power is turned off at facility s main circuit breaker before proceeding with installation.

CONCEALED CLOSER SERIES

5200 Series

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

9000 Series Trinity The world's most intelligent door closer

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

QUADSCAN User s Guide Door Mounted Presence sensor

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

NON-SIZED SIZED HANDED

SENIOR SWING UNIQUE FEATURES

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

Installation Instructions. Non Hold Open Models. Sized (Sizes 2,3,4,5) Weaker BC 9303BC 9304BC 9305BC. Stronger +

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

High Security Closers Series

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

HIGH SECURITY SERIES

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

High Security Closers Series

51 Series Door Closers. An ASSA ABLOY Group brand

HIGH SECURITY CLOSERS SERIES

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

*PULL SIDE mount shown

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

LCN 4010T SERIES HINGE (PULL) SIDE

9540 SERIES. Cast Iron Door Closer

7570 SERIES Security Door Closer

78-B/F Series. Traditional Door Closers

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

D O O R C L O S E R S

51 Series Door Closers. An ASSA ABLOY Group brand

2860 SERIES FEATURES OPERATOR MOUNTS INDEPENDENT PAIR, OVERHEAD CONCEALED *CENTER PIVOT OFFSET PIVOT/BUTT HINGE

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

2850 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms

DC8000 Series. Door Closers

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

Metal, Standard Wood and machine screw pack Top jamb (Push Side) Body Construction. Finishes/Colors/ Powder Coat. Wiring NON-SIZED SIZED

NON-SIZED SIZED HANDED

Assembly and Modular Table Power System Installation Instructions for Train Tables

*4110 HCUSH mount shown

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

1000 SERIES SURFACE MOUNTED CLOSERS

*HINGE (pull) side mount shown

The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding high traffic applications.

*CENTER PIVOT arm shown

LCN 2810 SERIES OPERATOR MOUNTS SINGLE DOOR, OVERHEAD CONCEALED CENTER PIVOT ARM OFFSET PIVOT/BUTT HINGE

Superior door control for rigorous, high-use applications 6000 LOW ENERGY OPERATOR CATALOG

*HINGE (pull) side mount shown COVER ACCESSIBILITY NON-HANDED NON-SIZED AVB**

An ASSA ABLOY Group brand Series. Architectural Door Closer

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

Door Closers. DC8000 Series

An ASSA ABLOY Group brand. 400/4400 Series. Institutional Door Closer

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

Transcription:

Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 7 for template) 7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 3 1 Push Side Applications with Double Lever Arms (7120SZ, 7130SZ) (see page 3 for template) 2 Item No. Description 1 Track (Pull Side) 2 over 3 Track Arm (Pull Side) 4 Double Lever Arm (Push Side) Tools required: Allen wrench set (inch) Flat blade screwdriver (potentiometer & terminal size) Screwdriver (Phillips size 2) Tape rule Power drill enter punch Wire stripper Use screw pack and hardware provided to mount operator. Requirements: Units are handed. Hand of unit and hand of door must be the same. All dimensions shown in inches (mm). Door must be hung on ball bearing butt hinges or ¾ (19) offset pivots. Door thickness must be 1-3/4" (44) to 2-1/4" (64). Door must swing freely through the entire opening and closing cycle before beginning the installation procedure. Frame face must be a minimum of 2" (51). eiling clearance must be a minimum of 3-1/2" (89) for push side application or 4 (102) for pull side application. See pages 3 and 7 for templates. Power input to unit must be of the same voltage as that stated on the unit. Unit to be mounted on interior of building in dry environment, maximum humidity of 95%. See NFPA70 for wiring requirements and NFPA72 for alarm system requirements. 4 Table of ontents: General Information...2 Push Side Template...3 Push Side Installation...3-5 loser Adjustments...6 Pull Side Template...7 Pull Side Installation...7-9 loser Adjustments...10 Electrical onnections...11 Sensor Info and Set-up...12-13 Troubleshooting...13 1

General Information omponent Layout loser/holder Unit Assembly "X" = Power Size: 3, 4 or 5 Pull Side: 711XUI24L 711XUI24R Push Side: 712XUI24L 712XUI24R Test/Power Switch Fasteners 1/4-20 machine screw Self drilling screw (Track screws only) Preparation for Fasteners Door or Frame Drill-Sizes Drill: #7 (0.201 dia.) Metal Tap: 1/4-20 Metal Pre-Drill: 9/64 hole Sensor Power Supply (120V units only) Backplate Standard Self drilling screw (loser mounting screws only) Metal Pre-Drill: 3/16 hole Backplate Mtg Screw (4) over Mtg Screw (6) over LH = 7100L RH = 7100R Optional Sleeve nuts and bolts (Shoe screws only) Through-bolts and grommet-nuts Hollow Metal Aluminum or Wood All 9/32 (7 mm) through; 3/8 (9.5 mm) door face opposite to closer 3/8 (9.5 mm) through 9/32 (7 mm) thru; 3/8 (9.5 mm) dia. x 3/8 (9.5 mm) deep on door opposite to closer Included with 7110SZ and 7150SZ Included with 7120SZ and 7130SZ 7110 Main Arm (7110-1A) 7150 Main Arm, Handed (7150-1L: Left Hand 7150-1R: Right Hand) 7130 Arm Assembly (7701-1B) Slide Track (7100-1T) Arm Screw (7701-MAS) 7120 Arm Assembly (7701-1A) Track End ap (2) Track Mtg Screw (2) Track over ushion Stop Assembly (7100B) ertifications Slide Assembly (7100SLD) NOTE: Optional remote for Advanced Settings (sensitivity, door control mode) if required. (7100REM) UL228, UL10B 2

7120SZ, 7130SZ: Double Lever Arm (Push Side) Use of an auxiliary door stop, by others, is required for these applications. eiling Line 3-1/2 Min (89) 2 Min (51) Hinge Edge Of Door RH - Right Hand Door LHR - Left Hand Reverse Left Hand Door - LH Right Hand Reverse - RHR 1 Prepare Frame Drill #7; Tap 1/4-20 4 (101.6) A 5/16 (7.9) 11-1/4 (285.8) 19-3/4 (501.7) 11/16 (17.5) 7/8 (22.2) 7/8 DIA THRU (22.2) For oncealed Wiring Only Frame B 1-3/4 (44.5) 1-5/8 (41.3) 1-3/4 (44.5) Frame Soffit Top of Door Hinge or Pivot Left hand door shown, right hand opposite. All dimensions shown in inches (mm). Model 712X SZ Door Open Angle Dim A Dim B Inches (mm) Inches (mm) Reveal 100 Max. 5-7/8 149.2 13-3/8 339.7 2-3/4-7 180 Max. 2-3/4-4 165 Max. 3-1/8 79.4 10-5/8 269.9 4-7 713X SZ 180 Max. 4-7 2 Operator Mounting Install two screws in the key slot locations leaving gap between screw head and frame as shown (a). a 3

3 Operator Mounting Hang closer body by key hole slots (b) and slide closer toward hinge to capture screw heads (c). b c 4 Operator Mounting Install remaining mounting screws through back plate and tighten all four screws (d). Pull wiring through holes (if concealed wired). d For oncealed Wired Only (If surface wired, see page 11) 5 Arm Shoe Mounting Mount closer arm shoe to door face as shown. 4

36 Attach Arm Main Arm e Arm Screw (7/16 Drive) Arm Mark L Y S R Z Pinion Flat e Align the pinion flat with the letter "S". 37 Preload loser Spring With the door closed and latched, rotate main arm until secondary arm is perpendicular to the door frame, then tighten adjustment screw as shown with 7/16 wrench. 90 38 loser Spring Adjustment losing Force Slowly increase closer power until door closes consistently. Stronger + 11/16" Wrench Weaker 5 NOTE: A closer set to the ADA required 5 lbs opening force may not be strong enough to close the door due to latching hardware, air pressure, or frame issues.

39 loser Adjustments losing Speed ontrols Valve "S" ontrols Sweep Range from full open to 5. Valve "L" ontrols Latch Range from 5 to closed. Opening ycle Valve "B" controls the strength of cushioning in Backcheck Range. NEVER close this valve completely it is not to provide a positive stop. Valve "P" adjusts the angle that backcheck is felt in the open cycle. "S" Sweep 5 Slower F r aste "L" Latch 5 0 Slower F r aste "B" Backcheck - Weaker + Stronger 75 Never lose backcheck valve completely "P" Backcheck Position 90 75 Do not remove valves from closer. Hydraulic oil will escape. 10 3 Electrical onnections See Page 11 11 3 Attach over Attach cover using screws provided. 6

7110SZ, 7150SZ: Track Mount (Pull Side) eiling Line 4 Min (102) 2 (51) Min RH - Right Hand Door LHR - Left Hand Reverse Left Hand Door - LH Right Hand Reverse - RHR 1 3/4 (19) Prepare Frame Prepare holes for mounting per instructions on page 2. *Track screws are self tapping and are smaller than closer mounting screws* 3-1/4 (82.6) 14-1/2 (368.3) 23 (584.2) 1-1/16 (27) 1-3/8 (34.9) 7/8 (22.2) 7/8 DIA THRU (22.2) For oncealed Wiring Only Frame Soffit Top of Door 6 (152.4) *9/64 (3.6) Holes for track screws* Hinge or Pivot Track Mount Unit 9/64 (3.6) Holes for track screws 19-1/8 (485.8) Series 7110SZ Standard Arm 7150SZ Double Egress Arm A 1-3/4 (44.5) Dim "A" 5/8 (15.9) 1-1/4 (31.8) 1/8 (3.2) Right hand door shown, left hand opposite. All dimensions shown in inches (mm). 2 Operator Mounting Install two screws in the key slot locations leaving gap between screw head and frame as shown (a). a 7

3 Operator Mounting Hang closer body by key hole slots (b) and slide closer toward hinge to capture screw heads (c). b c 4 Operator Mounting Install remaining mounting screws through back plate and tighten all four screws (d). Pull wiring through holes (if concealed wired). d For oncealed Wired Only (If surface wired, see page 11) 5 Arm Mounting Use main arm to rotate pinion until flat is visible. Mount closer arm to pinion square as shown. Align the pinion flat as shown. RIGHT HAND LEFT HAND Fully close Latch & Sweep Valves with wrench provided. RIGHT HAND RE-INSTALL HERE *All views from floor looking upward* LEFT HAND PINION FLAT 36 Attach Arm Attach arm with provided screw and washer. Tighten arm screw with 5/32" Allen wrench. 8

37 Mount Track If opening angle greater than 125, spring cushion stop cannot be used and an auxiliary stop by others is required. Set Screws toward hinge D B A E 1) Insert slider into track. 2) Insert spring cushion stop on hinge side of track for 125 or less opening angle. Do not use for openings greater than 125 3) Insert end caps (both ends). 4) Secure track to door using provided screws. 5) Snap on cover. 38 onnect Arm to Track Secure arm to slider assembly using 3/16" Wrench. Turn wrench counterclockwise to tighten. HINGE Open Latch & Sweep Valves with wrench provided. Open door to maximum desired swing minus 5 and hold. Slide spring cushion stop assembly against slider assembly and secure to track using 5/64" or 2mm wrench. 39 loser Spring Adjustment losing Force Stronger + 11/16" Wrench Weaker 9 Slowly increase closer power until door closes consistently. NOTE: A closer set to the ADA required 5 lbs opening force may not be strong enough to close the door due to latching hardware, air pressure, or frame issues.

10 3 loser Adjustments losing Speed ontrols Valve "S" ontrols Sweep Range from full open to 5. Valve "L" ontrols Latch Range from 5 to closed. Opening ycle Valve "B" controls the strength of cushioning in Backcheck Range. NEVER close this valve completely it is not to provide a positive stop. Valve "P" adjusts the angle that backcheck is felt in the open cycle. "S" Sweep 5 Slower F r aste "L" Latch 5 0 Slower F r aste "B" Backcheck - Weaker + Stronger 75 Never lose backcheck valve completely "P" Backcheck Position 90 75 Do not remove valves from closer. Hydraulic oil will escape. 11 3 Electrical onnections See Page 11 12 3 Attach over Attach cover using screws provided. 10

ELETRIAL ONNETIONS Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the terminal block or power supply using illustrations. aution: Determine proper input power; 24V or 120V. Surface mount power input: Remove appropriate shaded area from cover for surface wired installations only. Repaint cut edges as necessary to prevent corrosion. 120V A INPUT 7/8" 7/8" learance For Strain Relief 2-5/8" over surface facing ceiling. Make power connections as shown below. On/Off Switch Ground Neutral Live Terminal Block Make onnections Here 24V D INPUT Make power connections as shown below. On/Off Switch 24V(+) 24V(-) Terminal Block Make onnections Here 11

SafeZone Sensor Technical Specifications DESRIPTION SPEIFIATION Frequency: 24.125 GHz Supply voltage: 12 t 24 V D: -10% / +30%: Mounting height: Normal: 7 ; Maximum: 10-0 Tilt angle: 0 to 90 vertical -15 to +15 lateral Detection area: Wide Narrow 13ft (W) x 6.5ft (D) 6.5ft (W) x 8.2ft (D) (supplied as optional) Minimum detection speed: 2 in/sec. (measured in axis) Power consumption: Standard output relay: Max contact voltage Max contact current Max switching power < 2 W 60 VD / 125 VA 1 A (resistive) 30W (D) / 60VA (A) 0.5 sec. to 9 sec. (adjustable) Hold time: Temperature range: -4 F to 131 F Dimensions: 4.75in (W) x 3.15in (H) x 2.0in (D) Weight: 0.5lbs Material: ABS Safety Precautions Shut off all power going to the header before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. onstantly be aware of pedestrian traffic around the door area. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safety standards upon completion of installation. ELETROSTATI DISHARGE (ESD) PREAUTIONS ircuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body s charge. AUTION: In the event a unit needs to be opened, observe the following precautions. Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body. Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity. Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag. 12

Sensing Field Adjustments THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTIAL AND LATERAL ANGLE OF THE ANTENNA A B -30º +30 0º 30º 45º Sensing field as close to the door as possible: -antenna set at the position of 0 Sensing field close to the door: -antenna set at the position of 30 Sensing field far from the door: -antenna set at the position of 45 Hold Time Settings Hold open time refers to the time the door will remain open AFTER movement is no longer detected. Hold open time can be adjusted manually by means of the push buttons + (more) and - (less). + Press and release button to increase hold open setting (do not hold button continuously). (see table below) - Press and release button to decrease hold open setting (do not hold button continuously). Pressing the two push buttons, located on the circuit board, simultaneously for three seconds, will restore all default settings. Setting Time (Seconds) 0 0.5 1 5 2 6 3 7 4 8 5 (Default) 10 6 14 7 16 8 18 9 20 Recommended Settings: Example: If the current setting is 5 and the required setting is 8, press and release the button 3 times. Setting 1-3 Setting 4-6 Setting 7-9 Troubleshooting SYMPTOMS PROBABLE AUSE ORRETIVE Red LED does not light up. (No power to sensor) Power switch is off. Loose wire connection. ATION Turn power switch to ON position. Inspect wiring for loose connections. Door Stops several times in the same cycle without sensing presence in the door way. Door not closing when cover installed. Sensitivity is set too high Eye is sensing the closer cover. hange sensitivity setting using optional remote. Adjust the sensing field away from cover edge. (See Sensing Field Adjustments above. 3000 Highway 74 East Monroe, N 28112 Tel: (877)- 974-2255 Fax: (800)-338-0965 www.nortondoorcontrols.com 13