7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 80-9371-0081-00 (10-10) Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 5 for template) 3 1 Push Side Applications with Double Lever Arms (710SZ, 7130SZ) (see page 3 for template) Item No. Description 1 Track Cover 3 Arm (Pull Side) Double Lever Arm (Push Side) Requirements: Units are handed.hand of unit and hand of door must be the same. Door must be hung on ball bearing butt hinges or ¾ (19) offset pivots. Door thickness must be 1¾ () minimum ¼ (6) maximum. Door must swing freely through the entire opening and closing cycle before beginning the installation procedure. Frame face must be a minimum of (51). Ceiling clearance must be a minimum of (10). Power input to unit must be of the same voltage as that stated on the unit. Unit to be mounted on interior of building in dry environment, maximum humidity of 95%. See NFPA70 for wiring requirements and NFPA7 for alarm system requirements.
Component Layout Closer/Holder Unit Assembly Backplate Mtg Screw (5) Backplate Sensor Hook-up Board Access Tube Standard Fasteners 1/ - 0 machine screw Sleeve nuts and bolts Optional Through-bolts and grommet-nuts Preparation for Fasteners Door or Frame Drill-Sizes Drill: #7 (0.01 dia.) Metal Tap: 1/ - 0 Hollow Metal Aluminum or Wood All 9/3 (7 mm) through; 3/8 (9.5 mm) door face opposite to closer 3/8 (9.5 mm) through 9/3 (7 mm); 3/8 (9.5 mm) dia. x 3/8 (9.5 mm) deep on door opposite to closer Cover Cover Mtg Screw (3) Included with 7110SZ and 7150SZ Included with 710SZ and 7130SZ 7110 Main Arm (710-1A) 7150 Main Arm, Handed (750-1L, 750-1R) Slide Track (700-1T) 7130 Arm Assembly (7701-1B) Screw & Washer Slide Assembly (7700SLD) Arm Screw (7701-MAS) 710 Arm Assembly (7701-1A) Track Mtg Screw (3) NOTE: Optional remote for Advanced Settings (sensitivity, door control mode) if required. (7100REM) Certifications UL8 UL10B Page 80-9371-0081-00 (10-10)
710SZ, 7130SZ Double Lever Arm (Push Side) Ceiling Line 3-1/ Min (89) Min (51) Use of an auxiliary door stop, by others, is suggested, but is required for doors opening beyond 110. Hinge Edge RH - Right Hand Door LHR - Left Hand Reverse 1 Drill #7; Tap 1/-0 19-3/16 (10) A -1/8 (105) 11-3/8 (89) (87) For Concealed 8-11/16 WiringOnly (1) 7/8 () 5/16 (8) 11/16 (17) DIA THRU Left Hand Door - LH Right Hand Reverse - RHR 3 C Hinge or Pivot 7-1/ (191) 1-3/ () 1-5/8 (1) Left hand door shown, right hand opposite. All dimensions shown in inches (mm). DOOR OPENING ANGLE To 100 100 to 180 For Concealed Wired Only (If surface wired, go to Step 3.) Dimension A Inches (mm) 5-7/8 3-1/8 150 80 5 6 Arm Mark L Y S R Z Pinion Flat Main Arm Arm Screw (7/16 Drive) Page 3 80-9371-0081-00 (10-10)
7 8 Closing Force 90 11/16 Drive + 11/16" Drive Product shipped with closing force set at the middle of the power range. 9 Latch Sweep 1/8 wrench provided Positioning (75-95 ) Strength! Caution: Do not completely close backcheck valve. 10 MAKE ELECTRICAL CONNECTIONS: Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the hook-up board terminal strip using illustrations.! Caution: Determine proper control board; V or 10V. V AC/DC INPUT CIRCUIT BOARD 10V AC INPUT CIRCUIT BOARD Fuse PTO15V (15V / 1/A) V AC/DC Power Input Solenoid Safe Zone Sensor Fuse PTO15V (15V / 1/A) 10V AC Power Input Solenoid Safe Zone Sensor 11 1 Adjust settings Page 80-9371-0081-00 (10-10)
7110SZ, 7150SZ Track Mount (Pull Side) Ceiling Line Min (10) Use of an auxiliary door stop, by others, is suggested, but is required for doors opening beyond 110. (51) Min 1 Drill #7; Tap 1/-0 (10) 3-1/ (83) RH - Right Hand Door LHR - Left Hand Reverse -1/8 (105) 11-3/8 (89) 19-3/16 (87) For Concealed 8-11/16 Wiring Only (1) 7/8 () 1-1/16 (7) 1-3/8 (35) Left Hand Door - LH Right Hand Reverse - RHR DIA THRU (10) C Hinge or Pivot Track Mount Unit 11 (79) (559) 1-3/16 (30) 3 For Concealed Wired Only (If surface wired, go to Step 3.) Right hand door shown, left hand opposite. All dimensions shown in inches (mm). 5 6 Arm Indexing Fully close Latch and Sweep Valves with 1/8" wrench provided. RIGHT HAND RE-INSTALL HERE LEFT HAND Use main arm to rotate pinion until flat is visible. PINION FLAT Page 5 80-9371-0081-00 (10-10)
7 8 9 Arm Stud Slide Assembly Arm Washer Arm Screw Main Arm Open Latch & Sweep Valves with 1/8 wrench provided. 1 10 Closing Force 11 1/8 wrench provided! Caution: Do not completely close backcheck valve Latch Sweep Strength + 1 11/16 Drive Product shipped with closing force set at the middle of the power range. MAKE ELECTRICAL CONNECTIONS: V AC/DC INPUT CIRCUIT BOARD Positioning (75-95 ) Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the hook-up board terminal strip using illustrations.! Caution: Determine proper control board; V or 10V. 10V AC INPUT CIRCUIT BOARD Fuse PTO15V (15V / 1/A) V AC/DC Power Input Solenoid Safe Zone Sensor 13 1 Fuse PTO15V (15V / 1/A) 10V AC Power Input Solenoid Safe Zone Sensor Adjust settings Page 6 80-9371-0081-00 (10-10)
SafeZone Set-Up Sensor Technical Specifications DESCRIPTION SPECIFICATION Frequency:.15 GHz Supply voltage: 1 to V AC: 10%: 1 to V DC: -10% / +30%: Mounting height: Normal: 7 ; Maximum: 10-0 Tilt angle: 0 to 90 vertical -15 to +15 lateral Detection area: Wide Narrow 13ft (W) x 6.5ft (D) 6.5ft (W) x 8.ft (D) (supplied as optional) Minimum detection speed: in/sec. (measured in axis) Power consumption: Standard output relay: Max contact voltage Max contact current Max switching power < W 60 VDC / 15 VAC 1 A (resistive) 30W (DC) / 60VA (AC) 0.5 sec. to 9 sec. (adjustable) Hold time: Temperature range: - F to 131 F Dimensions:.75in (W) x 3.15in (H) x.0in (D) Weight: 0.5lbs Material: ABS Safety Precautions Shut off all power going to the header before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. Constantly be aware of pedestrian traffic around the door area. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safety standards upon completion of installation. ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body s charge. CAUTION: In the event a unit needs to be opened, observe the following precautions. Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body. Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity. Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag. Page 7 80-9371-0081-00 (10-10)
Mechanical Adjustments THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL AND LATERAL ANGLE OF THE ANTENNA A B C -30º +30 0º 30º 5º Sensing field as close to the door as possible: -antenna set at the position of 0 Sensing field close to the door: -antenna set at the position of 30 Sensing field far from the door: -antenna set at the position of 5 Set Up Hold open time refers to the time the door will remain open AFTER movement is no longer detected. Hold open time can be adjusted manually by means of the push buttons + (more) and - (less). + Press to increase hold open setting (see table below). - Press to decrease hold open setting. Pressing the two push buttons, located on the circuit board, simultaneously for three seconds, will restore all default settings. Setting Time (Seconds) 0 0.5 1 5 6 3 7 8 5 (Default) 10 6 1 7 16 8 18 9 0 Recommended Settings: Setting 1-3 Setting -6 Setting 7-9 Troubleshooting SYMPTOMS PROBABLE CAUSE CORRECTIVE ACTION Red LED does not light up. The sensor power is off. Check the wiring and power supply. Cable is not connected. Connect cable. ASSA ABLOY Norton is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Safe Zone is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 010 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 8 3000Highway7East Monroe,NC811 Tel: (877)-97-55 Fax: (800)-338-0965 www.nortondoorcontrols.com 80-9371-0081-00 (10-10)