INSTALLATION / INSTRUCTION MANUAL

Similar documents
SOLITEL. Vibrating Rod. Level Switch. for Solids. Installation and Operating Manual. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx

ECHOTEL MODELS 915-P / 915-W

Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

ECHOTEL 961/962 LINE POWERED

ECHOTEL 961/962 LOOP POWERED

VIZUAL. Magnetic. Level. Indication. Installation and Operating Manual For the Magnetic Level Indicator (MLI) 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx.

ECHOTEL 961/962 LOOP POWERED

Tuffy Liquid Level Controls with Pneumatic Switch

Series V. Electric. switch mechanisms. and housings. Installation and Operating Manual

Installation and Operating Manual

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

ECHOTEL 961/962 LOOP POWERED

J52 Refrigerant Level Switches

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

For Hazardous Locations

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Series K Pneumatic Switch Mechanism

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Tuffy Liquid Level Switches

Pneumatic Modulevel. Liquid level control ISO Worldwide level and flow solutions ASSURED QUALITY & SERVICE COST LESS STEEL FABRICATED MODELS

DIAMOND POINT VIBRATING PROBES

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

CVR-625. Compact Vibrating Rod Instruction Manual

L070 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL. For Industrial Use

THERMATEL MODEL TD1/TD2

Echotel Trident 91S/92S Ultrasonic Level Switches

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual

Read and understand this manual for safely usage.

For CRN Installations

P U L S A R point 210

Level Limit Switch soliphant FTM 930/931/932/ Z

Liquid filled Thermometers

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

Mobrey dry products level measurement and control

Electric Actuator Installation, Operation & Maintenance Manual

RP-4000 Reserve Power Control

Installation, Operation & Maintenance Manual. Bulletin: IOMS-PUL CHEMAlarm LEAK DETECTIONI

CONDUCTIVITY LEVEL LIMIT SWITCH User s Manual

Soliswitch FTE30. Technical Information

APM Pneumatic Control for Boiler Feed System Applications

Excellence in Level Measurement

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Capanivo Series CN 4000

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

VA-4233-GGx Series Electric Valve Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Hermetically Sealed Switches

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

ZDM Positive Displacement Flow Meter User Instructions

ROTARY Point Level Measurement for Inventory Control

7330 Pro-Stik II Magnetostrictive Level System

VA-715x Electric Valve Actuator

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Electromagnetic Flow Monitor magphant

KENCO ENGINEERING COMPANY

Read and understand this manual for safely usage.

P70, P72, and P170 Controls for Low Pressure Applications

F10. Vane type flow switches INSTRUCTION MANUAL AND PARTS LIST AGENCY APPROVALS DESCRIPTION OPERATING PRINCIPLE

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

External Cage Displacer Actuated

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Analog Condensate Monitor Instruction & Maintenance Manual

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material

Displacement Sensor. Model 8739, 8740, 8741

BMRX Series ROTARY LEVEL CONTROL

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Installation, Operation & Maintenance Instructions

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

TC26-B Vehicle Sensor

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Installation, Operation and Maintenance Manual

MULTIVOLT 2605 SERIES POWER CONDITIONER 50 Hz

STC 2L Series Solenoid Valves

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

INSTRUCTION MANUAL. Read before installing the recommendations and warnings on the last page of this manual. Vibra Switch S LEVEL SWITCH

Installation, Operation & Maintenance Manual

MA-5200 Series MA-5300 Series

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

Process Protection Motion sensors

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

TL-105-D COLUMN HEATER

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

Level Limit Switch liquiphant FTL 360 / FTL 361

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

Fig Single-Acting Rotary Smart Positioner

THERMATEL THERMAL DISPERSION

Transcription:

SOLITEL Vibrating rod level switches for solids INSTALLATION / INSTRUCTION MANUAL DESCRIPTION The Solitel vibrating rods are used for high or low level detection on powders and granulars with a minimum density of 0.05 kg/dm 3 and max. diameter of 10-12 mm. The electronics and the sensor are an integral unit for easy installation. OPERATING PRINCIPLE A resonant frequency of 350 Hz keeps the vibration on the resonant part of the sensor ongoing. The medium will dampen the vibration when reaching the sensor. For a successful switching operation, the vibrating part of the sensor should be covered for 20 to 60 mm (depending upon density). The sensed dampening will cause the electronics to actuate the relay. UNPACKING Unpack the instrument carefully. Inspect all units for damage. Report any concealed damage to carrier within 24 hours. Check the contents of the packing slip and purchase order. Check and record the serial and reference numbers for future reference when ordering parts. MODEL IDENTIFICATION A complete measuring system consists of Order code for SOLITEL sensor and electronics S H Standard SOLITEL - max 110 C (230 F) (Flexible sensor - max 90 C (200 F)) High temperature SOLITEL - max 160 C (320 F) (only for rigid sensors - VHH/VHR) TYPE OF SENSOR H Standard sensor with 235 mm (9.2") insertion length R Extended rigid sensor with insertion length from 50 cm up to 3 m (19.60" up to 9.8') K Extended flexible sensor with insertion length from 1 m up to 20 m (3.26' up to 65.6') S Non Ex A Dust Ex zone 10 POWER SUPPLY 1 240 V AC 2 024 V DC 6 024 V AC 0 120 V AC INSERTION LENGTH 0 0 0 Standard length = 235 mm (9.2") (VSH/VHH units) 0 5 0-3 0 0 Extended rigid sensors (VSR/VHR units), specify length in 10 cm (3.9") increments, min 50 cm (19.7") and max 300 cm (9.8'). 0 0 1-0 2 0 Extended flexible sensors (VSK), specify length in 1 m (3.28') increments, min 1 m (3.28') and max 20 m (65.6') V 1 B complete order code for SOLITEL rigid sensor and electronics

GENERAL INSTRUCTIONS MOUNTING Solitel switches have to be installed at the desired switching point. The VSH and VSR units may be installed horizontally (at 45 inclination) as well as vertically. The VSK units with wire rope extension should only be mounted vertically. However the mechanical torque on the sensor and the adhesion properties of the medium also have to be taken into consideration when installing the unit in the tank (see Electrical Specifications (page 3) for the maximum mechanical load on sensor). 1. Screw sensor part into the mounting bushing (G 1 1/2"). Only apply a wrench (width flats = 55 mm) on the mounting nut. 2. Position the housing manually in the correct direction to allow easy wiring. The housing can rotate one full turn. Important 1. Install the unit at a location where the level variation is detectable, taking the arching or caving of the material into account. See Figure 1. 2. Install the rigid sensors at a tilt angle larger than the slope angle of the material being filled (or for high level applications-vertically mounted), build up on the sensor would prevent the unit from starting the vibration and thus eliminates the 'self cleaning' effect which can lead to false output when level decreases. See Figure 1. WIRING Use cable with an outside diameter of 8 to 15 mm (0.3" to 0.6") _ inner core 0.75 to 2.5 mm 2 _ in order to block the cable sufficiently into the provided cable glands. 1. Make sure that the power supply is turned off. 2. Use a size 5 Allan type wrench to remove the housing cover _ 4 screws at top of housing. 3. Pass the power cable through the cable glands (conduit connection) into the housing (power is left cable gland, relays is right cable gland). 4. Connect power leads to the proper terminals. To allow access to the terminals, the unit utilises easy to remove connector plugs (power terminals are 1 and 2, see Figure 4). When using 3-wire cable, use the grounding screw at the inside of the housing base. When using 2-wire cable, provide a grounding wire to be connected to the grounding screw at the outside of the housing base. Caution: 24 V DC units: the negative terminal of the power supply is connected internally to ground. 5. Connect control circuit leads to relay terminals. (7, 8 and 9, see Figure 4) Caution: For alarm applications, it is recommended to use deenergised status of the relay as alarm status to allow detection of power failure as an alarm status, the relay contacts will show: POWER MATERIAL FAILSAFE RELAY COIL RELAY TERMINALS LEVEL JUMPER 7 and 8 8 and 9 A position de-energised open closed high B position de-energised closed open on A position de-energised closed open low B position de-energised open closed fails high/low A/B de-energised open closed High level indication Low level indication Figure 1 3. Install the unit in this way that the vibrating part is entirely free to vibrate. When the vibrating rod is fully blocked by medium, the unit will not change status of the relay. See Figure 2. 4. When the falling material can damage the rod by its nature (rough, heavy or with sharp angles) then protect the sensor. See Figure 3. 6. Reposition the connector plugs, pull excess cable back and tighten the cable gland. Finally screw cover on housing base. 7. Wiring is completed. Turn power on. High/low level selector LED Adjustment screw Power supply terminal Relay terminal Figure 2 Figure 3 5. Provide extra damping materials such as rubber joints, when the tank is exposed to intense vibrations. Grounding screw Figure 4 2

CALIBRATION After being properly installed the unit is fully operational. The LED will show the relay status. By touching the rod by hand and thus performing a damping of the vibration the LED will reverse colour. See Figure 4. The LED shows the status of the relay: RED = relay energised GREEN = relay de-energised. DENSITY ADJUSTMENT The unit is factory preset for media with densities higher than 0.3 g/cm 3. For lower densities turn the adjustment screw (see Figure 4) counterclockwise until the unit switches in that specific material. When adjusted too sensitive, the unit may detect even slight residues of the material instead of level. Caution: It is recommended to perform a test set up of the unit in a sample of the material to be detected before installation. MAINTENANCE The Solitel vibrating rods do not require maintenance on a regular basis. In some instances however it may be advised to clean the sensor of deposited material. STORAGE CONDITIONS Ambient temperature: -20 C up to +60 C (-4 F up to 140 F) Relative humidity: up to 98% F M M F VSH VSR VSK REPLACEMENTS PARTS Connector plugs for power supply: 2 pins Connector plugs for control circuits: 3 pins Cable gland PG 16 Sensor: VSH = standard rigid sensor VSR = extended rigid sensor, specify length from bottom mounting nut to end of sensor _ min. 0.5 m, max. 2 m (min. 1.6 ft, max. 6.5 ft) VSK = extended wire rope sensor, specify length from bottom mounting nut to end of sensor _ min. 1 m, max. 20 m (min. 3.2 ft, max. 65 ft) Electronics module 3

ELECTRICAL SPECIFICATIONS Description Specifications Input voltage 240 V AC (-15 to +10% tolerance on nominal voltage) 110 V AC 024 V DC / V AC Power consumption Operation frequency Output relay Time delay Process connection Housing less or equal than 3 V A ± 350 Hz 8 A, SPDT (max. load 250 V AC) 1 A, SPDT (max. load 024 V DC) 6 seconds 1 1/2" BSP thread IP65, cast aluminium Non Ex Dust Ex Zone 10 Max. process VSH/VSR -40 C to +110 C (-40 F to +230 F) -40 C to +110 C (-40 F to +230 F) temperature VHH/VHR -40 C to +160 C (-40 F to +320 F) -40 C to +160 C (-40 F to +320 F) Ambient temperature electronics VSK -25 C to + 90 C (-13 F to +200 F) -20 C to + 90 C ( -4 F to +200 F) -40 C to +60 C (-40 F to +140 F) Non Ex Dust Ex Zone 10 Max. process pressure VSH/VSR - VHH/VHR 25 bar abs (360 PSIG) 6 bar abs (87 PSIG) Rod material VSK 6 bar abs ( 87 PSIG) 6 bar abs (87 PSIG) all wetted parts of 316 Ti SST Materials: Vibrating rod 316 SS Ti (Standard electropolished) Process connection 14408 x 6 Cr Ni Mo 1810 Cable for extended flexible Solitel: PE coated steel standard extended flexible version rigid version version Max. mechanical load on rod 85 Nm 86 Nm 45 kn Weight of unit 2.5 kg 2.5 kg + 2.5 kg + 1.4 kg/m 0.6 kg/m APPROVALS Agency Approval DMT Dust Ex Zone 10 4

DIMENSIONS IN mm (inches) Standard VSH sensor Flexible VSK sensor 120 (4.72) 120 (4.72) 105 (4.13) PG 16 2 entries 105 (4.13) PG 16 2 entries 1 1/2" BSP process connection 1 1/2" BSP process connection Insertion length 235 (9.25) Ø 44 (1.73) Insertion length 1000-20000 (39.37-787.40) Ø 44 (1.73) 161 (6.34) 161 (6.34) Extended VSR rigid sensor 120 (4.72) 105 (4.13) PG 16 2 entries 1 1/2" BSP process connection Ø 44 (1.73) Insertion length 500-3000 (19.68-118,11) 161 (6.34) 5

IMPORTANT SERVICE POLICY Owners of Magnetrol products may request the return of a control; or, any part of a control for complete rebuilding or replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to the purchaser, (or owner) other than transportation cost if: a. Returned within the warranty period; and, b. The factory inspection finds the cause of the malfunction to be defective material or workmanship. If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour and the parts required to rebuild or replace the equipment. In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of our warranty. No claims for misapplication, labour, direct or consequential damage will be allowed. RETURNED MATERIAL PROCEDURE So that we may efficiently process any materials that are returned, it is essential that a Return Material Authorisation (RMA) form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is available through Magnetrol s local representative or by contacting the factory. Please supply the following information: 1. Purchaser Name 2. Description of Material 3. Serial Number and Ref Number 4. Desired Action 5. Reason for Return 6. Process details All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments. All replacements will be shipped FOB factory. UNDER RESERVE OF MODIFICATIONS BULLETIN N : BE 51-640.3 EFFECTIVE: FEBRUARY 1998 SUPERSEDES: July 1996 BELGIUM Heikensstraat 6, 9240 Zele Tel. (052) 45.11.11 Fax. (052) 45.09.93 DEUTSCHLAND Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg Tel. (02204) 9536-0 Fax. (02204) 9536-53 FRANCE Le Vinci 6 - Parc d activités de Mitry Compans, 1, rue Becquerel, 77290 Mitry Mory Tél. 01.60.93.99.50 Fax. 01.60.93.99.51 ITALIA Via Arese 12, I-20159 Milano Tel. (02) 607.22.98 (R.A.) Fax. (02) 668.66.52 UNITED Unit 1 Regent Business Centre KINGDOM Jubilee Road Burgess Hill West Sussex RH 15 9TL Tel. (01444) 871313 Fax (01444) 871317 INDIA B4/115 Safdurjung Enclave, New Delhi 110 029 Tel. 91 (11) 6186211 Fax 91 (11) 6186418