S 1125 HPLC Pump System

Similar documents
NEW HPLC - SYSTEM LINE

HPLC SYSTEM S 500 SERIES

HPLC System S 600 Series

Liquid Chromatography

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

High Pressure Gradient System. User Manual. Version 1.0 ( )

ACQUITY UPLC I-Class System with 2D Technology

PATROL UPLC Process Analysis System for Production

VERITY Purification Systems Build the perfect system to fit your research

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

HyperShear TM HPLC Mixers

HIGH PRESSURE SWITCHING VALVES

PrimeLine TM HPLC Pumps

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

ACQUITY UPLC I-Class System Specifications

HyperShear TM HPLC Mixers

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Technical Overview. Introduction

The Only No Compromise

Agilent 218 Purification Solution

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

ÄKTA system Training Guide

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers

QuickSplit TM Flow Splitters

Maintaining Your Agilent 1100 Series HPLC System

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Valving Schemes for the BioLogic Duo-Flow Chromatography System

Agilent 7693A Automated Liquid Sampler

Determination of Sudan Dyes I IV in Curry Paste

Fixed Flow Splitter *

Gilson, Inc. Table of Contents. Solid Phase Extraction Systems HPLC: Systems 2 9. Liquid Handlers HPLC: Liquid Handlers/Injectors 10 14

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Application Note. Authors. Abstract. Energy & Chemicals

Liquid Chromatography LC Consumables SSI-LC

Setting up SilFlow for BackFlush in your GC

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Agilent 7693A Automated Liquid Sampler

Instrumentation of HPLC. HPLC Solvent Pumping Systems

Agilent 1260 Infinity Standard Autosampler

ÄKTA avant 150. Product Documentation

Gilson, Inc. Table of Contents. HPLC: Liquid Handlers/Injectors GX-271 Analytical Liquid Handler...43 ISO 9001 certified.

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Agilent SD-1 Purification System ml/min

Adjustable Flow Splitter *

Hitachi High-Speed Amino Acid Analyzer

Agilent 1290 Infinity Autosampler

Neueste LC Entwicklungen

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

98 동방하이테크상사 T.(02) F.(02)

Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC

Your Essential Resource for INFINITYLAB LC SUPPLIES

Agilent G5632 Valve Kit Instructions

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

GENERAL CATALOG L.TEX CORPORATON

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

ProStar 340 UV-Vis Detector

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Agilent 1290 Infinity Quaternary Pump

Agilent 1290 Infinity Quaternary Pump

Motor Valve MV-7/IMV-7

850 Professional IC. AnCat MCS Manual EN

78 동방하이테크상사 T.(02) F.(02)

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

Welcome to KNAUER. Welcome to KNAUER - manufacturer of liquid chromatography instruments and solutions! Quality and environmental management

930 Compact IC Flex. Compact ion chromatography system for routine analysis

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

P680 HPLC Pumps. Operating Instructions. Revision: 2.0 Date: April Dionex. Doc.: P680_OI_E_V2_0.doc

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Agilent 1260 Infinity Binary Pump VL

Analysis of Petroleum Fractions by ASTM D2887

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Dionex CRD Carbonate Removal Device

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

Agilent 1260 Infinity Quaternary Pump VL

LC Instrument Replacement Parts

Agilent 1200 Series Valves

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

BioLogic DuoFlow Valving Guide

Stability Axial Compression Technology Application Ordering Information

Precise metering results!

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Technical Procedure for Gas Chromatography (GC-FID)

Transcription:

Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make this system suitable for the whole range of analytical applications. S 1125 HPLC Pump System The Sykam S 1125 HPLC Pump System is a very flexible and powerful HPLC solvent delivery system. The system is available as Isocratic HPLC pump and Quaternary Gradient Pump with optional integrated online vacuum degasser. for low pulsation. Together with electronic pressure compensation the S 1125 pumps are suitable for all analytical tasks in HPLC and GPC. Optional: Piston Backflushing The S 1125 s pump head incorporates an optional active piston backflushing system; this system is interchangeable with old Sykam pumps and does not require an additional motor. Stepper Motor The S 1125 is driven by a high-power stepper motor. The stepper motor has a much better resolution in the low-flow range than a conventional DC motor. Active Mixer The S 1125 low pressure gradient module has an active mixer to achieve highly precise and accurate gradient results. Lubrication The S 1125 camshaft is constantly lubricated within a sealed chamber to guarantee long lifetime and low maintenance. Dual-Piston Pumphead The S 1125 pumps use a dual-piston pumphead MADE IN GERMANY

Pump Mechanic Stepper Motor The S 1125 is driven by a highpower stepper motor. The stepper motor has a much better resolution in the low-flow range than a conventional DC motor. Lubrication The S 1125 camshaft is constantly lubricated within a sealed chamber to guarantee long lifetime and low maintenance. Optional: Active Piston Backflushing The S 1125 s pump head incorporates an automatic piston backflushing system; this system is interchangeable with old Sykam pumps and does not require an additional motor. Dual-Piston Pumphead The S 1125 pumps use a dual-piston pumphead for low pulsation. Together with electronic pressure compensation the S 1125 pumps are suitable for all analytical tasks in HPLC and GPC. Technical Specifications Wetted Materials: Stainless Steel / PEEK*, Teflon AF, PVDF, Ceramics, Sapphire, Ruby Flow Rate: Programmable Micro: 0.001-4.000 ml/min Analytical: 0.001-10.000 ml/min Semi-Preparative: 0.1-40.000 ml/min Flow Accuracy: ± 1.0 % 1.000 ml / min Flow Precision: ± 0.1 % RSD 1.000 ml/min Pressure Range: 0 40 MPa (0 6000 PSI); Semi-Preparative: 20 MPa (up to 20.000 ml/min); 10 MPa (up to 40.000 ml/min) Pressure Pulsation: typical < 0.1 MPa or < 1.0 % Compressibility user-adjustable for different solvents Compensation: Dimensions: 310 x 165 x 478 mm (W x H x D) Power Supply: 100-250 ~V (47-63 Hz) * depending on configuration S 1125 Quaternary Gradient Pump Vacuum Degassing: optional: < 20% dissolved gases remaining in water @ 1.000 ml/min Gradient Range: 0.0 100.0 %, 4 channels Gradient Accuracy: < 0.50 % Gradient Mixing: Active Mixer Volume: adjustable: 10 500 µl Figure: Quaternary Gradient Mixer Module with Vacuum Degassser 2

S 1125 Configurations S 1125 Isocratic HPLC Pump The S 1125 Isocratic HPLC Pump is a robust, lowpulsation solvent delivery system. The pumphead is easily accessible from the front panel to make routine maintenance, like changing pump seals, easy and fast. The transparent front cover makes it easy for the operator to detect any leakages. The pump is available with Micro, Analytical or Semi-Preparative pumphead in Stainless Steel or PEEK. S 1125G Low-Pressure Quaternary Gradient Pump The S 1125G Quaternary Gradient Pump incorporates an active low pressure mixer with adjustable mixing volume. The mixing chamber volume can be freely adjusted. An optional integrated vacuum degasser removes dissolved gases in the eluents and prevents air bubbles in the system. The system is available with Micro, Analytical or Semi-Preparative pumphead in Stainless Steel or PEEK. MADE IN GERMANY 3

The Sykam S 5250 Sample Injector System is a very flexible and powerful HPLC autosampler with excellent reproducibility and linearity properties. Variable vial racks and adaptors for microtiter plates as well as a multitude of firmware options make this system highly adaptable and suitable for any analytical application. Robust Design Durable X/Y/Z-Sampling The S 5250 Sample Injector System features a mechanically durable X/Y/Z-Sampling-Mechanic designed for long life operation. The self-lubricating bearings keep the routine maintenance at a minimum and avoid troubles caused by dusty environments. High precision stepper motors drive the X/Y axis for accurate positioning. Microstepping mode enables a high resolution for the syringe dosing and vial positioning. Dual-Needle Design The Dual-Needle design of the S 5250 Sample Injector System avoids system blockages due to septum particles injected into the system. The ventilation needle pierces the septum before the injection needle moves into the sample vial (see figure on the right). As the more fragile injection needle does not need to pierce the vial septum, stronger vial caps or plastic vials can be used without problems. Accessibility The injection valve with sample loop and injection port can be accessed directly from the instrument front without removing any protective covers. The dosing syringe can be accessed from the side of the instrument through a hinged glass panel. The exchange of the syringe can be done without the requirement of any tools. 1 2 3 Figure: Dual-Needle Injection 4

Precision & Modularity Performance The Sykam S 5250 Sample Injector System offers multiple injection modes depending on application and sample needs. Besides fixed loop overfilling and variable volume injection the instrument offers a Zero-Waste injection mode for injecting very small sample amounts by moving the sample into the middle of the sample loop. Linearity and injection precision can be optimized for any volume by different sample loops and syringe sizes. Technical Specifications Wetted Materials: Stainless Steel / PEEK*, PPS, PVDF Sample Capacity: 60/90 (1.5 ml), 96 (microtiter plates) Injection Volume: Programmable 0.1-999.9 µl Injection Precision: < 0.5 % Variable Volume Injection (10 µl; typically ~0.25 %) Linearity: Correlation Factor > 0.999 (10 µl injection volume, 500 µl Syringe) Carry Over: < 0.05 % with wash program Dimensions: (W x H x D) Power Supply: * depending on configuration 310 x 210 x 478 mm 100-250 ~V (47-63 Hz) Modular Options The modular nature of the Sykam S 5250 Sample Injector System offers the possibility to just buy what you need. Modular options include sample heating/cooling for any sensitive sample material and derivatization for automatized pre-column derivatization tasks from reagent derivatization to automatic sample dilution. MADE IN GERMANY 5

S 3245 UV/Vis Variable Wavelength Detector The Sykam S 3245 UV/Vis Detector is a variable wavelength UV/Vis detector for routine analysis and sophisticated research. The dual lamp design offers a wavelength range of 190 800 nm with a low baseline noise. The front-accessible flowcell can be easily exchanged, as can be the lamps which are accessible through a side panel in the instrument housing. Integrated Wavelength Program The S 3245 UV/Vis Detector features a wavelength program to change the selected wavelength over time. With this feature the optimum wavelength can be selected for each analyzed substance according to its retention time. Integrated Peak Detector The integrated Peak Detector works as a basic fraction collector. The peak detection level can be freely programmed for peak start and peak end to enhance the collection purity. An integrated 24V output for switching a solenoid valve is used for the fraction collection, which is automatically operated with a selectable time delay. Optional Dual-Wavelength The S 3245 UV/Vis Detector is available with an optional second wavelength. This feature enhances the Wavelength Program feature that you can measure 2 different wavelengths at the same time. A second D/A converter output comes with this option to keep the system flexible to be used with any data acquisition software available. Optional Online-Scan Another option for the S 3245 UV/Vis Detector is the Online Scan. With the Online Scan whole spectrum information can be gathered at a certain time. This scan information is stored internally and can be accessed at any time. The Online Scan is a good alternative to a full UV PDA detector. [mv] 20.0 10.0 0.0 Peak End Detection Level Peak Start Detection Level Peak Start Time Peak End Time 0.0 1.0 2.0 Solenoid 3.0 Valve OFF +Delay +Delay Solenoid Valve ON Fraction Collection Figure: S 3245 Peak Detector 6

Figure: S 3245 Optical Module Technical Specifications Wetted Materials: Baseline Noise: Baseline Drift: Wavelength Range: Wavelength Accuracy: Linearity: Light Source Wavelength Program: Stainless Steel / PEEK* ± 1 x 10-5 AU (@240 nm, 2 sec. Risetime) < 3 x 10-4 AU/h 190 800 nm ± 2 nm > 2.0 AU Deuterium Lamp, Tungsten Lamp Programmable, 10 steps Analog Output: 1x 1 V (optional: 2x 1V) Control Features: Dimensions: (W x H x D) Power Supply: * depending on configuration Internal Peak Detector with +24 V solenoid switching output. 310 x 165 x 478 mm 100-250 ~V (47-63 Hz) Principle of Operation Reference Signal Measuring Signal Grating Beam Splitter Flow Cell Deuterium Lamp Tungsten Lamp Figure: Principle of Operation MADE IN GERMANY 7

Order Information ROUTINE Isocratic System S 501 Catalog No Description 11 00 010 ROUTINE Isocratic System S 501-S Analytical SS* S 1125 Isocratic HPLC Pump S 3245 UV/Vis Detector 20 20 061 option: S 1125 Active Piston Backflushing 10 51 004 option: S 5250 Variable Volume upgrade 10 51 005 option: S 5250 Derivatization upgrade (incl. 10 51 004) 10 31 012 option: S 3245 Dual-Wavelength upgrade 10 31 013 option: S 3245 Scanning upgrade (incl. 10 31 012) Catalog No Description 11 01 013 ROUTINE Quaternary Gradient System S 504-P Analytical PEEK* S 1125G Quaternary Gradient Pump S 3245 UV/Vis Detector 20 20 061 option: S 1125G Active Piston Backflushing 10 10 085 option: S 1125G Vacuum Degasser 10 51 004 option: S 5250 Variable Volume upgrade 10 51 005 option: S 5250 Derivatization upgrade (incl. 10 51 004) 10 31 012 option: S 3245 Dual-Wavelength upgrade 10 31 013 option: S 3245 Scanning upgrade (incl. 10 31 012) Catalog No Description 11 00 011 ROUTINE Isocratic System S 501-P Analytical PEEK* S 1125 Isocratic HPLC Pump S 3245 UV/Vis Detector 20 20 061 option: S 1125 Active Piston Backflushing 10 51 004 option: S 5250 Variable Volume upgrade 10 51 005 option: S 5250 Derivatization upgrade (incl. 10 51 004) 10 31 012 option: S 3245 Dual-Wavelength upgrade 10 31 013 option: S 3245 Scanning upgrade (incl. 10 31 012) ROUTINE Quaternary System S 504 Catalog No Description 11 01 012 ROUTINE Quaternary Gradient System S 504-S Analytical SS* S 1125G Quaternary Gradient Pump S 3245 UV/Vis Detector 20 20 061 option: S 1125G Active Piston Backflushing 10 10 085 option: S 1125G Vacuum Degasser 10 51 004 option: S 5250 Variable Volume upgrade 10 51 005 option: S 5250 Derivatization upgrade (incl. 10 51 004) 10 31 012 option: S 3245 Dual-Wavelength upgrade 10 31 013 option: S 3245 Scanning upgrade (incl. 10 31 012) Sykam GmbH Systeme & Komponenten analytischer Meßtechnik Gewerbering 15 86922 Eresing Germany Tel.: ++49 (8193) 93 82-0 FAX: ++49 (8193) 93 82-20 EMail: Info@sykam.com Web: http://www.sykam.com September 2012 - V1.0 CHROMATOGRAPHY * all systems are also available in Micro or Semi-Preparative configurations on request All specifications are subject to change without notice.