TYPE V CENTER BREAK SWITCH

Similar documents
Product Specifications for Aluminum Vertical Break Switches

Aluminum Vertical Break Switch kv A.

Copper Vertical Break Switch kv A.

Copper Double Break Switch

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Product Specifications for Phase Over Phase GOABS(r)

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Transmission Switching

TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

AIRBREAK SWITCHES East Ginter Rd. Tucson, Arizona USA (520) Fax (520)

Disconnect & ByPass Switches

3.0OVERHEAD TRANSMISSION SWITCHES

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

SPECIFICATION BULLETIN

M-Force three-phase switch

Catalog 14A January 2013

TYPE BLT DISCONNECT SWITCHES

M-Force three-phase switch

Horizontal Circuit Switchers

OVERHEAD DISTRIBUTION SWITCHES

Horizontal Circuit Switchers

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Transmission Switching

Figure 1. HX cutout fuseholders.

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

Figure 1. HX cutout fuseholders. Positive Interruption

Unitized Quick Install Switches for Transmission Applications

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

S&C Recloser Bypass Disconnects

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

S&C Loadbuster Disconnects

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

CATALOG. Joslyn Hi-Voltage Overhead reclosers & switches

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

D-73P disconnect and bypass switches

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

OVERHEAD DISTRIBUTION SWITCHES

Three-Phase Pole Mounted Recloser

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

TYPE BILT DISCONNECT SWITCHES

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Typical Specification

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Solid Dielectric, Single Phase Recloser

JUMPERS & SWITCHING TOOLS

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Underground Distribution Switchgear

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

SECTION PANELBOARDS

Publication No.: PSG

Installation, Operation and Maintenance Manual

15 kv and 25 kv Thru-Bushings

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

S&C Type XS Fuse Cutouts

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Solid Dielectric, Single Phase Reclosers

25 kv Apparatus Bushings

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

S&C Manual PME Pad-Mounted Gear

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Medium Voltage Metal-Enclosed Switches

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Kuhlman Electric Corporation Volt Instrument Transformers

T HREE-SHOT TYPE MZR F USE CUTOUT

Single-Phase Step Voltage Regulators

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

S&C Type XS Fuse Cutouts

Kuhlman Electric Corporation Volt Instrument Transformers

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

PROTECTION AND CONTROL

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Medium Voltage Metal-Enclosed Switches

Transcription:

TYPE V CENTER BREAK SWITCH 3-PHASE, GROUP-OPERATED (SUBSTATION AND TRANSMISSION APPLICATIONS) *Available in Copper Horizontal upright, vertical or underhung mounting 15KV through 230KV 600A through 4000A Manual or motor operated control mechanism S M C O MANUFACTURER OF HIGH VOLTAGE PRODUCTS SINCE 1914 1.800.426.4380 1

FEATURES OF TYPE V SWITCH A 3-phase, group operated, center break, air break switch for substations and transmission lines. Since 1961, components of this design have proven their adaptability to system requirements and the validity of the philosophy simplicity means reliability. - Tubular or flat truss type blade. - Silver contact surfaces. - Assembled and adjusted at the factory. - Switch controls available for manual (swing handle or gear), or motor driven operation. - Available with various current interrupting devices. - Ratings from 15kV to 230kV --- 600A to 4000A. Positive Contact Assembly Current transfer points are independent contact shoes with silver to silver contact surfaces (heavy plating, inserts or flame spray metallizing as the application requires). Individual stainless steel backup springs on each shoe assures high pressure contact wiping on the tubular blade switch. Phosphor bronze backup springs perform the same function on the flat blade switch. Maintenance Free Bearing Design and Positive Linkage Tie Each insulator stack is supported by double ball bearings permanently lubricated and sealed for the life of the switch. The two rotating insulators are locked together through a maintenance-free tie rod which assures proper alignment at the switch contacts. The base assembly has open position and close position stops for a 90 full throw of the switch. Galvanized steel mounting angles are engineered to the customers structure. 2

Copper Positive Hinge Contact The hinge swivels on a stainless steel bearing rod. A high pressure stainless steel spring, outside the current path, applies pressure to the silver to silver current transfer points. OPERATING CONTROL MECHANISM The standard control mechanism is the torsional type using galvanized steel pipe. This control includes a toggle arrangement to assure mechanical locking of the switch poles in the open and closed positions. This arrangement gives the V switch maximum mechanical capability for ease of operation under normal and icing conditions. The manual swing handle or optional gear operator can be padlocked in either the open or closed position. The torsional control pipe can be converted to power operation. CURRENT INTERRUPTING DEVICES Arcing Horns Arcing horns are designed to prevent arcing at the main switch contacts. They have no interrupting rating, however, they are commonly used to interrupt small values of current such as transformer magnetizing current, or the charging current of a short length of line. Laminate Hinge Contact The hinge swivels on a stainless steel bearing rod. Hinge design utilizes a welded lamination to carry the current. Quick-Break The quick-break circuit interrupter is capable of interrupting a limited amount of line charging or transformer magnetizing current. It provides high speed contact separation by the means of a spring loaded whip. RVI-38 Vacuum Interrupter The vacuum interrupter will permit currents up to 2000 amperes to be interrupted. Loop splitting or parallel switching up to 161kV, if peak recovery voltage does not exceed 30kV. It is in the power circuit for only a few seconds during the opening operation, and is not in the circuit while the switch is closed or closing. Continuous, momentary, and impulse ratings of the switch are unaffected. 3

TYPE V SWITCH SPECIFICATIONS kv Amps Single Dimensions (in) Nom. Cont. Insulator Catalog Pole (kv (kamps T.R. No. B.I.L. Number Weight A B C D E F G H Max.) Mom.) (Lbs.) COPPER TRUSS BLADE SWITCHES 15 600 (40) 205 110 VF156 16 1/8 4 5/8 25 33 1/4 20 1/2 13 3/8 20 3/8 24 5/8 98 (15.5) 1200 (61) VF1512 110 23 600 (40) 208 150 VF236 19 5/8 6 29 7/8 38 1/8 24 5/8 15 7/8 22 7/8 27 1/8 126 (27) 1200 (61) VF2312 138 34.5 600 (40) 210 200 VF346 23 1/4 6 3/16 33 11/16 42 7/16 28 3/4 19 1/2 26 3/4 30 13/16 142 (38) 1200 (61) VF3412 154 46 600 (40) 214 250 VF466 26 5/8 8 3/4 39 5/8 48 3/8 32 1/2 22 29 1/4 37 1/2 156 (48.3) 1200 (61) VF4612 168 69 600 (40) 350 VF696 219 216 33 1/2 9 7/8 47 5/8 56 3/8 41 26 3/4 34 42 3/16 (72.5) 1200 (61) VF6912 231 COPPER TUBULAR BLADE SWITCHES 23 600 (40) V236 135 (27) 1200 (61) 208 150 V2312 20 1/4 5 3/4 30 1/2 39 1/4 24 9/16 15 7/8 22 7/8 27 1/8 157 1600 (80) V2316 159 34.5 600 (40) V346 151 (38) 1200 (61) 210 200 V3412 23 1/4 6 3/16 33 11/16 42 7/16 28 3/4 19 1/2 26 3/4 30 13/16 175 1600 (80) V3416 177 46 600 (40) V466 166 (48.3) 1200 (61) 214 250 V4612 26 5/8 8 3/4 39 5/8 48 3/8 32 1/2 22 29 1/4 37 1/2 191 1600 (80) V4616 194 69 600 (40) V696 238 (72.5) 1200 (61) 216 350 V6912 33 1/2 9 7/8 47 5/8 56 3/8 41 26 3/4 34 42 3/16 265 1600 (80) V6916 270 115 600 (40) V1156 444 (123) 1200 (61) 286 550 V11512 49 1/2 16 1/4 70 78 3/4 61 1/2 38 1/2 45 3/4 63 3/8 475 1600 (80) V11516 482 138 600 (40) V1386 474 (145) 1200 (61) 288 650 V13812 57 1/4 19 1/8 80 5/8 89 3/8 71 44 51 1/4 74 507 1600 (80) V13816 516 161 600 (40) V1616 623 (170) 1200 (61) 291 750 V16112 64 1/8 21 1/2 89 7/8 98 5/8 79 49 1/2 56 3/4 79 1/2 659 1600 (80) V16116 669 600 (40) V2306 717 230 (245) 1200 (61) 304 900 V23012 79 7/8 28 7/8 113 121 5/8 97 1/4 59 66 1/4 89 757 1600 (80) V23016 770 600 (40) V2306Z 770 1200 (61) 312 1050 V23012Z 89 7/8 32 7/8 127 N/A 113 3/4 68 7/16 75 11/16 N/A 813 1600 (80) V23016Z 829 ALUMINUM TUBULAR BLADES 15 1200 (61) AV1512 16 1/2 4 1/8 26 1/8 30 20 1/2 13 3/8 20 3/8 24 5/8 92 (15.5) 2000 (100) 205 110 AV1520 17 1/4 5 1/4 28 32 97 23 1200 (61) AV2312 20 5 3/8 30 7/8 34 11/16 24 1/2 15 7/8 22 7/8 27 1/8 116 (27) 2000 (100) 208 150 AV2320 20 3/4 6 1/2 32 3/4 36 1/2 121 1200 (61) AV3412 23 1/4 6 5/8 35 3/8 39 3/16 132 34.5 2000 (100) 210 200 AV3420 24 7 3/4 37 1/4 41 28 5/8 20 3/4 24 1/2 30 13/16 138 (38) 3000 (120) AV3430 25 9/16 8 1/4 38 3/8 43 1/16 165 46 1200 (61) AV4612 26 3/4 7 3/4 40 43 13/16 147 (48.3) 2000 (100) 214 250 AV4620 27 1/2 8 7/8 41 7/8 45 1/2 33 3/4 23 1/8 26 7/8 37 1/2 154 3000 (120) AV4630 29 9 7/16 43 47 5/8 181 1200 (61) AV6912 33 1/2 10 3/8 50 3/8 54 3/16 218 69 2000 (100) 216 350 AV6920 34 1/2 11 1/2 52 1/4 56 41 27 5/16 31 5/8 42 3/16 225 (72.5) 3000 (120) AV6930 35 13/16 11 7/8 52 5/16 57 255 4000 (120) AV6940 37 3/16 11 1/4 53 13/16 57 11/16 265 1200 (61) AV11512 49 1/2 16 3/8 71 3/8 75 3/16 433 115 2000 (100) 286 550 AV11520 50 1/4 17 1/2 73 1/4 77 61 1/4 39 7/16 43 1/8 63 3/8 478 (123) 3000 (120) AV11530 51 5/16 17 7/8 73 11/16 78 5/16 515 4000 (120) AV11540 52 11/16 17 1/8 75 3/16 79 1/16 527 1200 (61) AV13812 57 1/4 19 1/8 81 7/8 85 11/16 462 138 2000 (100) 288 650 AV13820 58 20 1/4 83 3/4 87 1/2 70 1/2 44 13/16 48 1/2 74 508 (145) 3000 (120) AV13830 59 20 5/8 84 3/16 88 13/16 548 4000 (120) AV13840 60 3/8 20 85 11/16 89 9/16 561 1200 (61) AV16112 64 21 3/4 91 1/4 95 611 161 2000 (100) 291 750 AV16120 64 3/4 22 7/8 93 1/8 97 78 3/4 49 5/8 53 5/16 79 1/2 658 (170) 3000 (120) AV16130 65 7/8 23 93 1/2 98 3/16 700 4000 (120) AV16140 67 1/4 22 3/8 95 98 7/8 715 1200 (61) AV23012 79 1/2 27 1/4 112 1/4 116 703 2000 (100) 304 900 AV23020 80 1/4 28 3/8 114 1/8 118 97 1/4 60 7/16 64 1/8 85 752 3000 (120) AV23030 81 5/16 28 5/8 114 1/2 119 3/16 799 230 4000 (120) AV23040 82 11/16 28 116 119 7/8 816 (245) 1200 (61) AV23012Z 89 1/2 31 5/8 126 5/8 755 2000 (100) 312 1050 AV23020Z 90 1/4 32 3/4 128 1/2 804 N/A 109 11/16 67 1/2 71 9/16 N/A 3000 (120) AV23030Z 91 3/8 33 128 15/16 856 4000 (120) AV23040Z 92 3/4 32.375 130 7/16 881 NOTES 1. Dimensions are in inches and are for NEMA standard station post insulators. 2. Counterbalance supplied as required at higher voltage ratings. 3. Grounding switches available - consult factory. 4. Polymer insulators available on aluminum tubular Type V switches up to 138kV 5. Non-standard insulators are available upon request. 4

TYPE V SWITCH SPECIFICATIONS ** ** THIS DIMENSION WILL VARY FOR DIFFERENT PAD HEIGHT REQUIREMENTS MINIMUM 1 ¾ S M C O * Base mounting customized to meet customer requirements MANUFACTURER OF HIGH VOLTAGE PRODUCTS SINCE 1914 1.800.426.4380 5