A softer start, from pumps right up to the complex machines

Similar documents
Number 1 in efficiency

Flexible. Intelligent. Trendsetting.

Motor Applications Automation. Command and Signalling Power Management Product Overview for Machinery

Number 1 in efficiency

Flexible. Intelligent. Trendsetting.

Electrical Engineering Info

Easy Multifunctional Safe

Flexible. Intelligent. Trendsetting.

Easy Multifunctional Safe

Eaton convincing in terms of safety, performance and operational availability. Innovations for the Motor Control Center MCC

Reliably Switching Highest Currents up to 2000 A

Reliably Switching Highest Currents up to 2200 A

Heating, Ventilation & Air Conditioning Industrial Cooling - Refrigeration Industrial Pumping & Ventilation

Easy Multifunctional Safe

Reliable Protection. Simplified Wiring. CI-K enclosure system

Transformers Flexible and Reliable

Starts, stops and protects. Emotron TSA Softstarter

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

A softstarter beyond the ordinary

EMX3 SOFT STARTER. Take control from the start

1.1. Reduced Voltage Motor Starters

DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw)

CEAG GuideLed AT. Cost-eff icient and environment-friendly exit sign luminaire

CA Z-EN Overload relays, CT-operated overload relays

RE SERIES RACK INSTALLATION GUIDE

Application Description

Powering business worldwide

SINAMICS GM150 IGCT version

Variable speed drive or soft starter?

SIMOTICS FD looks different, offers more

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Intelligent Drivesystems, Worldwide Services ELECTRONIC DRIVE SYSTEMS UP TO 200 HP

Reduced Voltage Motor Starters

Medium voltage vacuum circuit breaker. E-VAC series

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Maximum Cable Lengths for Eaton s Protective Devices

: Efficient solutions for motor control

Intelligent Drivesystems, Worldwide Services. ELECTRONIC DRIVE SYSTEMS UP TO 160 kw

Bussmann series NH photovoltaic fuse links

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

Modular Standardized Electrical and Control Solutions for Fast Track Projects

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

For Operation in the Control Cabinet 3RW Soft Starters

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

: Efficient solutions for motor control

NH photovoltaic fuse links

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

MP-4000 Motor Protection

3RW Soft Starters. General data. 6/4 Siemens LV

E / HYDAC KineSys Electric cylinders (HEZ)

Microgrid solutions Delivering resilient power anywhere at any time

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

New XNH fuse-switch disconnectors

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

Mechanical engineering partner

Application example of a motor controlled by MCD100 and protected by a circuit breaker

MECHANICAL Forging PRESSES WITH KNUCKLE-JOINT

SIRIUS Soft Starters Introduction

PSE The efficient range Description

Drive System Application

Mechanical engineering partner

Your choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw

PKZ and PKE motor-protective circuit-breakers

DIN Dual indication fuse links

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Drive Systems for Protective Machine Doors Tried and proven

Charge up in Control MENNEKES Load Management. Intelligent charge and load management for operational safety and cost control

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

That s how compact transformer protection is today. The customer newsletter of Kries-Energietechnik

Just as precise as your motion control application siemens.com/servo-geared-motors

Softstarters Softstarters

Start-up instructions

Low Voltage Systems MNS platform

VSMeasy Wiring Systems and Motor Starter Combinations

Press brakes HFE-M2 series

XL Photovoltaic fuse links

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Transforming Transforming Advanced transformer control and monitoring with TEC

825-P Modular Protection System for motors Specification Guide

Low and medium voltage service. Power Care Customer Support Agreements

500 Volts gg/gl NH Fuse links

Soft starters Altistart 01 The starting solution

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017.

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Development test stands for E-motors

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors.

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Motor Starters, Soft Starters and Load Feeders

Transcription:

Soft starter S801+/S811+ Soft starter DS7 www.eaton.eu/softstarters A softer start, from pumps right up to the complex machines

Eaton the Right Drive for your Technology. In the field of plant and machinery construction Eaton is your single-source provider. Whether energy management, automation, signaling or solutions all around the motor Eaton covers the entire machine. Variable frequency drives, soft starters, motor starters and hydraulics components provide solutions for all tasks involving drives. Motor-protective circuit-breaker PKZ SmartWire-DT turns standard switchgear into intelligent PKE motor-protective circuit-breakers Knowing exactly how much power a motor is using at all times has clear benefits: Overload increases machine availability. automation devices. DS7 soft starters Through SmartWire-DT the PLC has direct access to all of the soft starter s parameters. PowerXL variable frequency drives All variable frequency drives of the PowerXL family DC1 and DA1 can be quickly connected to SmartWire-DT. Lean Solution powered by SmartWire-DT Machinery construction needs a technology that simplifies its processes. SmartWire-DT moves the I/O level to the devices, allowing simple, quickly engineered structures without an I/O level at the PLC. Data transparency simplifies diagnostics and maintenance, thereby reducing wiring, testing and commissioning time and costs by up to 85%. Example: Savings at every stage of the lifecycle Lean solution Conventional solution Savings 30 % Planning / Engineering Material Wiring Comissioning Maintenance 2

Eaton produces world market products for machinery construction. www.eaton.eu/softstarters Eaton has a local presence for its customers in more than 175 countries. www.eaton.eu/electrical/ customersupport For CAD data for our products see on www.eaton.eu/cad Get your new Drives Engineering catalog today: Antriebstechnik@eaton.com Ahead of the future Machinery construction is becoming increasingly demanding and competitiveness depends more and more on the technology and on the suppliers s capability to present themselves effectively on the market. Eaton is your right partner to help you achieve these aims. From effective detail solutions through overall efficiency to our comprehensive service we provide al-inclusive solutions on a national and global level. A focus on drives engineering With its Moeller Series products Eaton has been a reliable partner in machinery engineering for many decades. Product brands such as PKZ, DIL and RMQ-Titan prove the point. A further focus is on drives engineering, which is continually being expanded with innovative new products. The development focus here is on the efficiency of your processes and solutions. Lean Solution for drives engineering Our intelligent connection and communications technology SmartWire-DT is gaining popularity and is successfully establishing in all segments. The core of the Lean Solutions strategy is the identification and optimization of the operating sequences in machinery and control panel construction. Our product portfolio from motor starters through soft starters to variable frequency drives has continued to expand to the present day. 3

Soft starter in the xstart system. Soft at the start, high on torque The soft starter has become increasingly established as an alternative to the star-delta starter. The soft starter DS7 can handle applications based around a single-phase load of up to 200 A without further add-ons. It combines the benefits of its predecessor, the DS4, with those of the xstart system. The DS7 is a fully integral element in this system; all existing components can be used. The DS7 replaces the mechanical contactor and extends the function Motor soft start. Motor start-up is soft but still at a higher torque than other available solutions using a patented method. Extended service intervals and reduced operating costs are welcomed side effects. Designed for normal applications such as pumps, fans and small conveyors, the compact DS7 is ideal. The DS7 will soon be available with a SmartWire-DT connection to simplify wiring and enhance functionality as an automation solution. 4

Application examples Single and three-phase inductive loads Noiseless and soft switching of motor starters in transport and conveyor belts Soft starting of pumps reduces the load on the entire installation (water impact) Solid-state switching of pumps in the extreme environments of chemical plants and filling stations Smooth start that reduces wear on V-belts in fan drives Soft starting: the modern alternative to star-delta starters Electronic soft starter fulfil the customer demand for an impact free rise in torque and a determined reduction in current during the start phase. You control the power supply of the three-phase motor in the start phase so that the motor matches the load behaviour of the load machine. The mechanical equipment is accelerated with the minimum of stress as a result. The operating behaviour and the work processes are influenced positively which means that negative influences are avoided such as: Impacting of cog edges in the gearbox, U-Start U Reduction of the water hammers in pipe systems, Slipping of V-belts, t-start t-stop t Jitter with conveyor systems. The product standard for the area of soft starters is the IEC / EN 60 947-4-2. The soft starter DS7 provides you with the opportunity to optimally match the drive to your application. You can set the start and stop functions and the start voltage using just three potentiometers. t-start (s) U-Start (%) t-stop (s) Asymmetric control: It does not get any softer The asymmetrical trigger control developed and patented (PCT/EP00/12938,19.12.2000) by Eaton makes it possible. It avoids DC components which normally result on a twophase controlled soft starter (see diagram). They suppress the formation of an elliptical rotating field, which leads to an irregular acceleration of the motor and unnecessarily extends acceleration times. On DS7 series devices, an asymmetric trigger control is active during the start and stop ramp. Current characteristic in the uncontrolled phase Conventional methods: Symmetrical control with high level of DC components New process from Eaton: Asymmetric control without DC components 5

Full integration prevents limitations The built-in fan removes any limitations when connecting accessories. Even with a built-in fan, the overload relay can be attached directly to the DS7. Accordingly, the handling does not need to be reconsidered irrespective of whether standard applications or applications requiring additional cooling are necessary, e.g. with increased starting frequency or higher ambient temperatures. The xstart system concept is retained. Soft starter DS7 up to 32 A for three-phase power supply low operating frequency (5 s, 3x I e, 10 Starts) Assigned motor rating at 400 V Assigned motor rating at 460 V Rated operational current 1) Soft starter kw HP A In-Line Part no. Contactor and Overload relay 3) motor protection 2) (optional) Part no. Part no. Part no. 1.1 1,5 3 DS7-34xSX004NO-x PKZM0-4 (+ CL-PKZ0) ZB12-4 DILM7 1.5 2 4 DS7-34xSX004NO-x PKZM0-4 (+ CL-PKZ0) ZB12-4 DILM7 2.2 3 5 DS7-34xSX007NO-x PKZM0-6,3 (+ CL-PKZ0) ZB12-6 DILM7 3 5 7 DS7-34xSX007NO-x PKZM0-10 (+ CL-PKZ0) ZB12-10 DILM9 4 5 9 DS7-34xSX009N0-x PKZM0-10 (+ CL-PKZ0) ZB12-10 DILM9 5.5 10 12 DS7-34xSX0012NO-x PKZM0-12 (+ CL-PKZ0) ZB12-12 DILM12 7.5 10 16 DS7-34xSX0016NO-x PKZM0-16 (+ CL-PKZ0) ZB32-16 DILM17 11 15 24 DS7-34xSX0024NO-x PKZM0-25 (+ CL-PKZ0) ZB32-24 DILM25 15 25 32 DS7-34xSX0032NO-x PKZM0-32 (+ CL-PKZ0) ZB32-32 DILM32 Mains contactor 4) (optional) Notes: 1) Rated operational current related to the stated load cycle. 2) States the required circuit-breaker for the defined load cycle. With other switching operations (operating frequency, overcurrent, overcurrent time, duty factor) this value changes and must be matched accordingly. The same applies with higher motor currents. 3) An external overload relay is necessary, if the main circuit is not to be disconnected with an overload but rather a controlled soft stop is required. 4) A mains contactor is not necessary. Isolating characteristics to VDE can only be assured via the stated circuit-breaker. 6

Together they are strong xstart system Whether motor connector or PKE connection, the soft starter DS7 integrates seamlessly into this system. Even integration into the automation using a SmartWire-DT connection is possible. Should separate motor protection be required, the overload relays ZB12 or ZB32 can also be mounted together with the optional fan. A system without limitations that can be configured to the requirements of the user. Soft starter DS7 in the xstart System (up to 32 A) Legend 20 1 DS7 with SmartWire-DT 2 DS7 size 1 up to 12 A 3 DS7 size 2 up to 32 A 4 Device fan DS7-FAN-32 5 SmartWire-DT gateways 6 SmartWire-DT external device connector 7 SmartWire-DT cable 8 Overload relay 9 Motor connector in tool-less plug connection 10 Socket for motor connector 11 Wiring set PKZM0-XDM in tool-less plug connection 12 Wiring set PKZM0-XDM in tool-less plug connection 13 Wiring set PKZM0-XDM 14 Three-phase commoning link 15 Standard auxiliary contact 16 Early-make auxiliary contact 18 Motor-protective circuitbreaker PKZM0 19 Motor-protective circuitbreaker PKE 20 Incoming terminal 21 Voltage release 22 Standard auxiliary contact 23 Standard auxiliary contact 24 Motor-starter combination with PKZ 25 Motor-starter combination with PKE 26 Busbar adapter 27 Top-hat rail adapter plate 21 5 7 17 16 12 9 15 15 11 6 7 2 T1 4 T2 6 T3 9 1 19 18 4 10 2 T1 4 T2 6 T3 22 23 2 14 10 4 24 25 3 13 4 26 27 8 7

NZM1 2 x 17.5 mm L1 L2 Compact in-line starter Soft starter DS7 in a system L3 The performance spectrum is spread across just two sizes. The dimensions and the terminals correspond with the tried and tested Eaton standard from the circuit-breakers NZM1 (up to 55kW) and NZM2 (up to 110 kw). I > I > I > In conjunction with the mounting and connection accessories of the circuitbreaker series NZM, the devices of the DS7 series provide the opportunity for compact electronic motor starters up to 200 A. DS7 bis 55 kw The terminals on the NZM can be optimally matched to those of the DS7 with the spacers NZM1/2-XAB. M 3 ~ Soft starter DS7 up to 200 A for three-phase power supply low operating frequency (5 s, 3x I e, 10 Starts) Assigned motor rating at 400 V Assigned motor rating at 460 V Rated operational current 1) Soft starter kw HP A In-Line Part no. Contactor and motor protection 2) (Coordination type 1 ) Overload relay 3) Part no. Part no. Part no. Mains contactor optional 4) 22 30 41 DS7-34xSX041N0-x NZMN1-M50 / PKZM4-50 ZB65-40+ZB65-XEZ DILM50 30 40 55 DS7-34xSX055N0-x NZMN1-M63 / PKZM4-58 ZB65-57+ZB65-XEZ DILM65 37 50 70 DS7-34xSX070N0-x NZMN1-M80 ZB150-70/KK DILM80 45 60 81 DS7-34xSX081N0-x NZMN1-M100 ZB150-100/KK DILM95 55 75 100 DS7-34xSX100N0-x NZMN1-M100 ZB150-100/KK DILM115 75 100 135 DS7-34xSX135N0-x NZMN2-M160 ZB150-150/KK DILM150 90 125 160 DS7-34xSX160N0-x NZMN2-M200 Z5-160/FF250 DILM185 110 150 200 DS7-34xSX200N0-x NZMN2-M200 Z5-220/FF250 DILM225 Notes: 1) Rated operational current related to the stated load cycle. 2) States the required circuit-breaker for the defined load cycle. With other switching operations (operating frequency, overcurrent, overcurrent time, duty factor) this value changes and must be matched accordingly. The same applies with higher motor currents. 3) An external overload relay is necessary, if the main circuit is not to be disconnected with an overload but rather a controlled soft stop is required. 4) A mains contactor is not necessary. Isolating characteristics to VDE can only be assured via the stated circuit-breaker. 8

Soft starter DS 7 with circuit-breaker NZM (up to 200 A) 16 10 11 15 12 13 17 7 18 19 14 23 22 21 20 6 5 4 1 2 7 3 10 9 8 Legend 1 DS7 with SmartWire-DT 2 DS7 size 4 up to 200 A 3 DS7 size 3 up to 100 A 4 Device fan 5 Superfast semi-conductor fuses 6 Fuse holder for superfast semi-conductor fuses 7 IP2X protection against contact with a finger 8 Overload relay 9 Gateways for SmartWire-DT 10 SmartWire-DT external device connector 11 Circuit-breaker NZM 12 Spacer 13 Voltage release 14 NZM communication module for SmartWire-DT 15 Data management Interface (DMI module) 16 Voltage releases / Earlymake auxiliary contacts 17 Terminal covers for terminals 18 IP2X protection against contact with a finger 19 Terminal covers for cable lugs 20 Connection width extension 21 Control circuit terminal 22 Box terminals 23 Tunnel terminals for Al and copper cables 9

... und ist mit dem SWD-Assist schnell und einfach am Ziel SmartWire-DT efficient engineering, convenient communication DS7 soft starters with SmartWire-DT keep tabs on everything. SmartWire-DT is an innovative intelligent connection system for your control cabinet. Simply make connections and work without control wiring, without a distributed I/O level, and without having to resort to clunky DIP switch-based address configurations. In peripheral devices, SmartWire-DT is routed directly to the machine and turns standard switchgear into intelligent and communications-capable automation devices. SmartWire-DT is the optional add-on and provides all required information without complex and expensive wiring. DS7 soft starters with SmartWire-DT Direct access to all parameters Being able to use a controller to directly access all of a soft starter s parameters via SmartWire-DT is the epitome of ease of operation. Users can read and overwrite potentiometer settings. Extended status, error, and diagnostic messages can be retrieved directly. The result: absolute data transparency. The plug-in units make installation fast and foolproof, and the resulting connection includes the soft starter s control current supply. Advantages: Reduced I/O level Plug-in control wiring prevents wiring errors Integrated solution does not require any additional options 10

Reduced engineering costs, by up to 70% Fault-free mounting and wiring Reduced time required for wiring, testing and commissioning by up to 85% Maintenance with direct diagnostics Motor starters from our standard range of products with SmartWire-DT DS7 soft starters are connected to PKZ or PKE motor-protective circuit-breakers by means of a plug-in design that does not require any tools. NZM circuitbreakers are available for soft starting three-phase asynchronous motors with currents of 32 A and higher. In conjunction with a PLC, SmartWire-DT is not only a simple and cost-effective solution, but also has many advantages: Access to all parameters (read and write) Read and overwrite manually configured device parameters Detailed diagnostics and status messages available Parameter access with a service laptop (parallel to PLC access) even during ongoing operation Motor-starter combination Perfect motor protection with PKE In connection with SmartWire-DT, using a motor-starter combination consisting of a PKE motor-protective circuit-breaker and a DS7 soft starter results in a number of new advantages that provide perfect motor protection and increased availability. Device protection against overloads Additional soft starter protection if there are too many starts per hour Overload protection relay function (in the event of an overload, the DS7 will trip instead of the PKE) Diagnostics and status messages available via SmartWire-DT Increases system availability by transmitting process-relevant data Advance warning function for avoiding overloads Eliminates time-consuming troubleshooting during commissioning and maintenance Adjustable current limiting function SWD-Assist helps achieve objectives quickly and simply SWD-Assist enables users to simply select functional elements from a device catalog and place them where needed. This is of enormous help when planning, designing, and commissioning SmartWire-DT networks, as configurations can be saved and reused in other projects. The software can also test networks and be used to add any missing components. SWD-Assist can be downloaded for free at: http://downloadcenter.moeller.net/de/software 11

Soft starter S801+ / S811+ Soft to start, powerful range of functionality The soft starter has become increasingly established as an alternative to the star-delta starter. The DS7 series from Eaton offers solutions for simple applications with up to 200 A of motor current, while the S8x1+ can handle more complex tasks up to 1450 A. Three-phase motors are typically for simple and economic implementation of machine and system concepts. Unlike star-delta starters, the soft starter offers a smooth motor start that protects the network. For many applications, it is simply a better solution. The Eaton S801+ / S811+ soft starter family is ideal for applications involving pumps, fans and conveyor applications. Extended service intervals and reduced operating costs are welcomed side effects. The S801+ / S811+ offer very good performance, including protection functions. The devices are equipped with monitoring functions and are suitable for use in more complex applications. The ease of operation, compact sizes and user-friendly diagnostic functions translate into reduced running costs, despite higher productivity and longer lifespans. 12

Application examples Three-phase inductive loads Soft switching of motor starters in transport and conveyor belts Soft starting of pumps reduces the load on the entire installation (water impact) Solid-state switching of pumps in the extreme environments of chemical plants and filling stations Star-delta replacement (especially for motors over 5.5 kw that must be operated using star-delta starters) Fans and pumps for HVAC applications Water/water treatment industry Mixer Crusher Underground applications Chemical industry Extreme ambient conditions (temperature, vibration, aggressive gasses) Star-phase starter Soft starter S811+ Savings 58 % More power in a minimum of space When compared with a standard 30 kw star-phase starter, the soft starter S811+ stands out for its minimal size and compactness. As much as 58% less space is required. The soft starter also saves value space in the control cabinet compared with competitors products. Simply communicative The S8x1 has an on-board Modbus RTU interface capable of establishing communication without any additional options. All device and monitor data can then be polled within the PLC. A network connector for Ethernet/IP, Modbus TCP, Profibus and DeviceNet (C441x) is also optionally available to make it fully compatible with complex systems. On-site diagnostics The control panel provides clear-text information about the current operating state, regardless of whether it s displaying the three phase currents or offering a diagnostic alarm. As such the user can review the status of the machine without having to reach for the manual. 13

Water hammer effect, begone The special pumping algorithm used in the S811+ prevents the infamous water hammer effect when the pump stops. This is above and beyond the normal ramping function in the soft starter, as the algorithm detects the status of the pump and follows its non-linear characteristic curve in a special way to avoid water hammer effect. 100% Flow Start Run Stop Direct start by contactor, top load for the mechanics and the pipeline system, water hammer effect included in the design Conventional soft start, gentle initiation of the pump, soft stop, but always with (reduced) water hammer effect Eaton pump stop, with a gentle, steady start even in the final phase and a gentle stop until complete standstill of the pump is achieved, without (or with highly reduced and barely perceptible) water hammer effect, the soft alternative for pump and pipeline systems. Tested switchgear combinations for in-line and in-delta connections Soft starter S8x1+ offers a flexibly adjustable internal motor protection function. Motor current and overload class can be set up to class 30, eliminating the need for an external overload relay. The measured current can be read out of the internal Modbus interface for further use in the process. The S8x1+ requires only the NZM circuit-breaker against short circuiting of the motor lines to achieve full motor output. The In-Delta connection is only possible with S811+, as it necessitates an extra mains contactor that is not required for in-line operation. In-Line In-Delta I I I NZMB2-S125 NZMB2-S125 I I I DILM115 100 A 100 A 3 S811+R10.. (105 A) S811+N66.. (66 A) M 3 ~ 55 kw 400 V 400 / 690 V 100 / 59 A S1 55 kw cos ϕ 0.86 1410 rpm 50 Hz M 3 ~ 55 kw 400 V 14

S801+, the cost-effective variant The S801+ differs from the S811+ only in its control interface. Instead of the plain-text display, a simply designed combination of switches and potentiometers is used for precise configuration of the S801+. As such, the current settings for the soft starter are easy to see without having to draw out the individual settings from the menus. No In-Delta configuration is possible, and troubleshooting is handled by LEDs instead of clear-text notifications. Soft starter S8x1 up to 1471 A Rated operational current assigned motor rating at400 V assigned motor rating at 480 V Soft starter Soft starter Mains contactor Cable protection In-Line In-Delta A kw HP Part no. Part no. Part no. Part no. 37 18,5 25 S8x1+N37x3S PKM4-40 66 30 50 S8x1+N66x3S S811+N37x3S DILM72 NZMN1-S80 105 55 75 S8x1+R10x3S S811+N66x3S DILM115 NZMN2-S125 135 75 100 S8x1+R13x3S NZMN2-S160 180 90 150 S8x1+T18x3S S811+R10x3S DILM185A NZMN2-S200 240 132 200 S8x1+T24x3S S811+R13x3S DILM250 NZMN3-S250 304 160 250 S8x1+T30x3S S811+T18x3S DILM400 NZMN3-S320 360 200 250 S8x1+U36x3S S811+T24x3S DILM400 NZMN3-S400 360 200 250 S8x1+V36x3S NZMN3-S400 420 200 350 S8x1+U42x3S NZMN3-S500 420 200 350 S8x1+V42x3S NZMN3-S500 500 250 400 S8x1+V50x3S S811+T30x3S DILM580 NZMN3-S500 650 315 500 S8x1+V65x3S S811+U36x3S DILM750 NZMN4-ME875 720 400 600 S8x1+V72x3S S811+U42x3S DILM750 NZMN4-ME875 850 450 600 S8x1+V85x3S S811+V50x3S DILM1000 NZMN4-ME875 1125 630 850 S811+V65x3S DILM1600 NZMN4-ME1400 1246 630 850 S811+V72x3S DILM1600 NZMN4-ME1400 1471 750 1100 S811+V85x3S DILM1600 IZMX16 (*) Switch only when at a complete stop 15

Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.eu. To contact an Eaton salesperson or local distributor/agent, please visit www.eaton.eu/electrical/customersupport Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton internet pages and Eaton order confirmations. Eaton Industries GmbH Hein-Moeller-Str. 7 11 D-53115 Bonn / Germany 2017 by Eaton Corporation All rights reserved Printed in Germany 09/13 Publication No.: BR039001EN / CSSC-634 ip November 2017 Article No.: 172746 Eaton is a registered trademark of Eaton Corporation All other trademarks are property of their respective owners. SmartWire-DT is a registered trademark of Eaton Corporation.