Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Similar documents
Diesel Generator Set S3.8 Series Engine

Rental Power QSB7 series engine

Rental Power QSL9 series engine

Diesel generator set QSK23 series engine

Diesel generator set QSB7 series engine

Diesel generator set 4BT3.3 series engine

Diesel generator set QSL9 series engine

Diesel generator set QSK23 series engine

Diesel generator set 6BT5.9 series engine

Diesel generator set QSX15 series engine

Diesel generator set QSK78 series engine

Diesel generator set QSX15 series engine

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set QSK60 series engine

Spark-ignited generator set

Diesel generator set QSL9-G7 series engine

Rental Power 4BTAA3.3 series engine

Diesel generator set QSK50 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSK78 series engine

Diesel generator set QSK60 series engine

Spark-ignited generator set

Diesel generator set QST30 series engine

Rental Power Kubota V2403 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Diesel generator set QSK60 series engine

Diesel generator set QSL9 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Spark-ignited generator set

Rental Power 800 kw. Specification sheet. Description. Features. Options

Diesel generator set QSK95 series engine

Diesel Generator set QSK95 series engine

Rental Power KTA50 G3 series engine

Diesel Generator set QSK95 series engine

Tier4 certified diesel generator set QSK50 series engine

Tier4 certified diesel generator set QSK78 series engine

Rental Power 1500 kw. Specification sheet. Description. Features. Options

PowerCommand 2.2 control system

Diesel Generator Set Model DFJD 60 Hz

Diesel generator set C17D5T series

Diesel Generator Set Model DGDB 60 Hz

Diesel Generator Set Model DFHB 60 Hz

Diesel Generator Set Model DFBF 60 Hz

2000kW Rental Package

Diesel Generator Set Model DFCE 60 Hz

PowerCommand 1.1 control system

Digital generator set control PowerCommand 3100

Spark-Ignited Generator Set Model GGLA 60 Hz

PowerCommand 2.2 control system

Spark-Ignited Generator Set Model GGKD 60 Hz

Model DFEH 60 Hz EPA Emissions

30 KW / 40 KVA POWERED by

Model DKAC 60 Hz EPA Emissions

55 KW / 70 KVA POWERED by

16 KW / 20 KVA POWERED by

130 KW / 165 KVA POWERED by

Model DSHAE 60 Hz EPA Emissions

Spark-Ignited Generator Set Model GGFD 60 Hz

Spark-Ignited Generator Set Model GGKC 60 Hz

500 KW / 625 KVA POWERED by

Model DFHD 60 Hz EPA Emissions

Gaseous Fuel Generator Set Model GFDA

640 KW / 800 KVA POWERED by

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

1000 KW / 1250 KVA POWERED by

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

60 KW / 75 KVA POWERED by

80 KW / 100 KVA POWERED by

204 KW / 254 KVA POWERED by

64 KW / 80 KVA POWERED by

1800 KW / 2250 KVA POWERED by

700 KVA / 550 KW POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

130 KW / 165 KVA POWERED by

18 KW / 18 KVA POWERED by

600 KW / 750 KVA POWERED by

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Power Connect TM Series RX60

28 KW / 28 KVA POWERED by

300 KW / 375 KVA POWERED by

Diesel Generator Set Model DSHAD 60 Hz EPA Emissions

PowerCommand 1.2 control system

70 KW / 90 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Gaseous Fuel Generator Set QSK19G Engine Series

2000 KW / 2500 KVA POWERED by

20 KW / 25 KVA LIQUID COOLED POWERED by

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

45 KW / 55 KVA POWERED by

Transfer switch OTEC open or delayed transition

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

19 KW / 24 KVA POWERED by

57 KW / 71 KVA POWERED by

105 KW / 130 KVA. POWERED by TP-I100-T2-60. kva 130 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 125 Prime Power Factor 0.

PowerCommand iwatch Wireless

Transcription:

Specification sheet Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz Description This Cummins Power Generation commercial generator set is a fully integrated power generation system, providing optimum performance, reliability, and versatility for stationary standby and prime power duty applications. Features Cummins medium-duty engine - Rugged 4-cycle industrial diesel delivers reliable power and fast response to load changes. Alternator - Low reactance 2/3 pitch windings; low waveform distortion with nonlinear loads, fault clearing short-circuits capability, and class H insulation. Cooling system Standard Integral setmounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat. Control system The PowerStart electronic control is standard equipment for 50 Hz products while PowerCommand is for 60 Hz products. It provides total genset system integration, including auto remote start/stop, precise frequency and voltage regulation, alarm and status message display. Enclosures - Optional sound attenuated enclosures are available. Warranty - Backed by a comprehensive warranty and worldwide distributor network. 3-Phase Ratings Standby rating Prime rating 50 Hz 60 Hz 50 Hz 60 Hz Model kva (kw) kw (kva) kva (kw) kw (kva) C44 D5e 44 (35) 40 (32) C55 D5e 55 (44) 50 (40) C66 D5e 66 (53) 60 (48) C40 D6e 40 (50) 36 (45) C50 D6e 50 (63) 45 (57) C60 D6e 60 (75) 55 (68) C44 D5L 44 (35) 40 (32) C55 D5L 55 (44) 50 (40) C66 D5L 66 (53) 60 (48) 2017 Cummins Power Generation Inc. S-6282-EN

Generator set specifications Governor regulation class ISO 8528 G2 Voltage regulation, no load to full load ± 2.5% Random voltage variation ± 2.5% Frequency regulation 6% Droop for 50Hz and Isochronous for 60Hz Random frequency variation ± 0.75% Radio frequency emissions compliance BS EN 61000-6-4 / BS EN 61000-6-2 Engine specifications Design 4 cycle, in-line, turbo charged after cooled Bore 95 mm (3.75 in.) Stroke 115 mm (4.53 in.) Displacement 3.3 L (199 in 3 ) Cylinder block Cast iron, 4 cylinder Battery capacity 65 AH Battery charging alternator 35 Amp Starting voltage 12 Volt Fuel system Direct injection Fuel filter Spin on fuel filters with water separator Air cleaner type Dry replaceable element with restriction indicator Lube oil filter type(s) Spin on full flow filter Standard cooling system* 131 ºF (55 ºC) ambient radiator *Open genset at 12.7mm H₂O restriction Alternator specifications Design Brushless, single bearing, revolving field Stator 2/3 pitch winding Rotor Single bearing, flexible disc coupling Insulation system Class H Standard temperature rise Standby 50/60 Hz 163 ºC/27 ºC ambient Exciter type Self-excited Phase rotation A (U), B (V), C (W) Alternator cooling Direct drive centrifugal fan AC waveform total harmonic distortion (THDV) No load <1.5%. Non distorting balanced linear load <5% Telephone influence factor (TIF) for 60Hz < 50% per NEMA MG1-22.43 Telephone harmonic factor (THF) for 50Hz < 2% Available voltages 50 Hz line line / line - neutral 380/220 190/110 400/230 200/115 416/240 208/120 60 Hz line line / line - neutral 380/220 190/110 400/230 200/115 416/240 208/120 440/255 220/127 480/277 230/132 240/139 *Note: Some voltages may not be available on all models - consult factory for availability.

Generator set options Sound attenuated housing 4P MCCB 332 liter fuel tank Alternator heater Engine coolant heater Aux contact Dual wall, with secondary Lower temp rise alt frame Heavy duty air cleaner Earth fault relay containment Permanent magnet generator Electronic governing on 50 Circuit breaker size Remote fuel filling (PMG) Hz Language literature PC 1.2 Mains operated battery Shunt trip Extended warranty charger Aux 101 Industrial grade silencer *Note: Some options may not be available on all models - consult factory for availability.

Generator set control PowerStart 500 Control system The PowerStart control is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied. The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line. This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel soft-switches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel. All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults. Base control functions LCD display - 16 character x 2 line alphanumeric LED backlight LCD. Operation interface - Six tactile-feel membrane switches for LCD navigation, genset operation and control setup. These switches are indicated by internationally accepted symbols and English text. Data logs - Includes engine run time and controller on time. Fault history - Provides a record of the most recent fault conditions with control hours time stamp. Up to 5 events are stored in the control non- volatile memory. Alternator data Voltage (single or three phase line-to-line and lineto-neutral) Current (single or three phase) KVA (three phase and total) Frequency Engine data Starting battery voltage Engine running hours Engine temperature Engine oil pressure Service adjustments - The control includes provisions for adjustment and calibration of generator set control functions. Functions include: Voltage selection Frequency selection Configurable input set up Configurable output set up Meter calibration Units of measurement Protective functions On operation of a protective function the control will indicate a fault by illuminating the appropriate status LED, as well as display the fault code and fault description on the LCD. The nature of the fault and time of occurrence are logged in the control. The service manual and InPower Service Tool provide service keys and procedures based on the service codes provided.

Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8 VDC to 16 VDC. Major features LCD display - 16 characters x 2 line alphanumeric LED backlight LCD. Generator set monitoring and protection. 12 VDC battery operation. Engine Starting - Includes solid state output to operate external relays start the engine, fuel shut FSO), and glow plugs. Start disconnect is achieved by monitoring main alternator frequency. Remote Start Capability Interface to transfer switch. Environmental protection The control is designed for reliable operations in harsh environments. Warranty and service - Backed by a comprehensive warranty and worldwide distributor service network. Certification - Suitable for use on generator sets are designed, manufactured, tested and certified to relevant ISO, EC Mil Std. and CE standards. Field control interface Input signals to the base control include Remote start Local and emergency stop Configurable inputs: Control includes (4) input signals from customer Output signals from the control include Configurable output: Control includes (1) solid state driver rated at 1 A. This output can be configured to activate on ready to load, or common warning and common shutdown condition. Communications connections include PC tool interface: This RS-485 communication port allows the control to communicate with a personal computer running InPower software. Note An RS-232 or USB to RS-485 converter is required for communication between PC and control.

Ratings definitions Standby: Applicable for supplying power to varying electrical OPEN load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Prime (Unlimited Running Time): ENCLOSED Applicable for supplying power in lieu of commercially purchased power. Prime power is the maximum power available at a variable load for an unlimited number of hours. A 10% overload capability is available for limited time. (Equivalent to Prime Power in accordance with ISO8528 and Overload Power in accordance with ISO3046, AS2789, and DIN6271). This rating is not applicable to all generator set models. Base Load (Continuous): Applicable for supplying power continuously to a constant load up to the full output rating for unlimited hours. No sustained overload capability is This outline drawing is to provide representative configuration details for Model series only. See respective model data sheet for specific model outline drawing number. Do not use for installation design available for this rating. Consult authorized distributor for rating. (Equivalent to Continuous Power in accordance with ISO8528, ISO3046, AS2789, and DIN6271). This rating is not applicable to all generator set models. Cummins Power Generation Europe, CIS, Middle East and Africa Manston Park Columbus Ave. Manston, Ramsgate Kent CT12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 Americas 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 2017 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. S-6282-EN cumminspower.com

Open Enclosed A B C Dry Wt. A B C Dry Wt. Model mm (in) mm (in) mm (in) kg (lbs) mm (in) mm (in) mm (in) kg (lbs) C44 D5e 2050 (81) 967 (38) 1510 (59) 922 (2033) 2270 (89) 975 (38) 1920 (76) 1236 (2725) C55 D5e 2050 (81) 967 (38) 1510 (59) 922 (2033) 2270 (89) 975 (38) 1920 (76) 1236 (2725) C66 D5e 2050 (81) 967 (38) 1510 (59) 1019 (2247) 2270 (89) 975 (38) 1920 (76) 1423 (3137) C40 D6e 2050 (81) 967 (38) 1510 (59) 922 (2033) 2270 (89) 975 (38) 1920 (76) 1326 (2923) C50 D6e 2050 (81) 967 (38) 1510 (59) 949 (2092) 2270 (89) 975 (38) 1920 (76) 1353 (2983) C60 D6e 2050 (81) 967 (38) 1510 (59) 1019 (2247) 2270 (89) 975 (38) 1920 (76) 1423 (3137) C44 D5L 2050 (81) 967 (38) 1510 (59) 922 (2033) 2270 (89) 975 (38) 1920 (76) 1236 (2725) C55 D5L 2050 (81) 967 (38) 1510 (59) 922 (2033) 2270 (89) 975 (38) 1920 (76) 1236 (2725) C66 D5L 2050 (81) 967 (38) 1510 (59) 1019 (2247) 2270 (89) 975 (38) 1920 (76) 1423 (3137) * Note: Weights represent a set with standard features. See outline drawings for weights of other configurations. Codes and standards This generator set is designed in facilities The 50 Hz generator sets are available certified to ISO 9001 and manufactured in with CE certification. facilities certified to ISO 9001 or ISO 9002. All enclosed products are designed to meet This generator set has been designed to 2000/14/EC or exceed EU noise legislation 2000/14/EC ISO 8528 comply with ISO 8528 regulation. step 2006. Cummins Power Generation Europe, CIS, Middle East and Africa Manston Park Columbus Ave. Manston, Ramsgate Kent CT12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 Americas 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 2017 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. S-6282-EN cumminspower.com