Royce Total Suspended Solids Systems. Water & Wastewater

Similar documents
Turbidity and Suspended Solids Transmitter

Dissolved Oxygen Measurement System with Air Blast Cleaner

Model DFX Doppler ultrasonic flow meter

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Mobrey MSM400 Ultrasonic sludge density measurement system

Model Q45H/ Residual Chlorine Monitor...

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Sludge Blanket Level Measurement

ISTEC MAGNETIC METERS

Hot Tap Insertion Vortex

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

CONTROLLERS & SPECIAL VALVES

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

State-of-the-art viscosity monitoring

MagFlux Q 8200 Series

Introducing the new Steady Flygt 1300 series. Power to go

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Low Profile Insertion Vortex

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

DISSOLVED OXYGEN MEASUREMENT

Electromagnetic Flowmeters. Product Overview.

F-2700 SERIES INSERTION VORTEX FLOW METER

Hydrovar and Packaged Hydrovar

Signet Pressure Transmitter

F-1500 SERIES INSERTION TURBINE FLOW METER

HVAC Products. Introducing the SED2 Variable Frequency Drives

UTM10 Series Ultrasonic Transit-time Flowmeters

Appendix. Clearance. Skewed profiles. Application Schematics

Level and Flow Measurement. Sludge Finder 2

Signet Conductivity/Resistivity Electrodes

Full Profile Insertion

Model FVP General Specification. Flanged Vortex Plate. Product Features

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

SS Concentration Analyzer

F-2600 SERIES INLINE VORTEX FLOW METER

2100 Turbine Flow Sensor

mass flowmeter for compressed air

F-2700 SERIES INSERTION VORTEX FLOW METER

Type Electrically Actuated Ball Valve

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Vortex Plate. Model VP General Specification. Product Features

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

Flow Measurement Technology Training

Model Model Model

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Ultrasonic Sludge Blanket Monitoring System

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

PRESSURE BENCH OPERATING INSTRUCTIONS

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

KEL DIFFERENTIAL PRESSURE FLOWMETERS

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

INSTRUMENTATION & CONTROL

Type Electrically Actuated Ball Valve

KEL. Heavy Duty Differential Pressure Flowmeters

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

imag 4700 SERIES FLANGED MAGMETER

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

introduction TKD Series 3-Way Automated Ball Valves Product Data Sheet

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Signet Temperature Transmitter

AQUAVAR AQUAVAR 56 AQUAVAR CPC

Accessories Guide ph/orp/conductivity Sensors

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CANADA SENSORS TECHNOLOGY INC.

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Digital ph transmitter

Rosemount 8750WB Magnetic Flowmeter System

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

BAPI-Stat 3 Room Sensor

RF Point Level Control with Sensor Monitor

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

HUMIDITY / TEMPERATURE TRANSMITTER

OEM Pressure Transmitters

Direct Automation Trade Price List Process Controls Sensors 1

Industrial Pressure Transmitters

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Signet Conductivity/Resistivity Electrodes

Signet Pressure Transmitter

Sanitary RTDs and Temperature Transmitters

Ultrasonic Sludge Blanket Monitoring System

G2 Industrial Grade Meters

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Harris IRT Enterprises Digital Resistance Tester Model XP

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Figure 1: WPR2 Dimensions and Hardware

Digital ph transmitter

4.30 [109] 5.43 [138] FCI FlexMASSter ST98 Series: The Best Value in a 8.00 [203] High Performance. Flange. Mounting Hole. Positioning to Split Flow

SIGNET Temperature Transmitter

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

General Purpose Toroidal Conductivity Sensors

Transcription:

Royce Total Suspended Solids Systems Water & Wastewater

Portable and Continuous TSS Systems MODEL 711 PORTABLE MLSS/ILA SYSTEM FEATURES Two complete analyzers in one package (TSS & Interface Level) Microprocessor based Automatic ranging Simple, insitu calibration Electronic self-diagnostics Nine volt battery with automatic shutoff Waterproof, rugged housing MODELS 7110/7120 SERIES CONTINUOUS SYSTEM FEATURES Automatic ranging Simple to use insitu calibration Menu driven text help screens Electronic self diagnostics Digital communications with isolation and surge protection Isolated current or voltage outputs Up to 2 set-point relays per channel User selectable calibration curves Backlit display (7110/7120) Menu driven text help screens Phased array source for automatic color compensation (Model 73B/73P Sensor) Automatic ambient light compensation on all sensors NEMA 4X (IP65) enclosure MODEL 711 PORTABLE MLSS/ILA SYSTEM MODEL 7011A SINGLE CHANNEL ANALYZER MODEL 7110/7120 SINGLE/DUAL CHANNEL ANALYZER 2

CONTINUOUS MONITORING AND CONTROL SOLIDS ANALYZERS The Model 7011A Total Suspended Solids (TSS) Analyzer is the tried and true performer that has buttressed the Royce line of solids analyzers for years. Still the most used TSS analyzer in the industry, the Model 7011A is the primary single channel offer in the Royce line of analyzers. 100 10,000 up to 800 80,000 mg/l (Sensor Dependent) Standard Outputs: 4 20 ma or 0 1 VDC (Isolated) RS-485 serial port (isolated and surge protected) Standard Setpoints: Two programmable setpoint relays All relays are form C rated 250 VAC, 7 Amps resistive Readout Device: Harsh environment, 2.2 x 1.5 LCD digital display Input Power: Switch selectable 115/230 VAC, 60/50 Hz Enclosure: NEMA 4X (IP65) Fiberglass Instrument Ambient Conditions: Temperature: -10 to 50ºC With Heater: -40 to 50ºC Humidity: 0 to 100% Analyzer Options: NEMA 4X enclosure with quick disconnect for sensor Rear Rail mounting kit JB-93 junction box with quick disconnect for sensor 5.5 Lbs (2.5 kgms) MODELS 7110/7120 ANALYZERS The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication while utilizing one or two Royce TSS sensors. Sensors do not have to be the same model. The Series 8000 Water Process Analyzer can be made up to a 4-channel system that will incorporate up to any two TSS sensors plus two Dissolved oxygen sensors. While it can be purchased as a dual channel, 3-channel or 4-channel system, the sensor combinations are almost unlimited. Instrument Ambient Conditions: Temperature: -10 to 50ºC Humidity: 0 to 100% Input Power: 80 260 VAC, 60/50 Hz or 12 VDC Outputs: Four isolated 4 20 ma per analyzer 600 ohms maximum Four Relays with programmable hysteresis 10A resistive @ 250 VAC RS-485 & Modbus (Standard) Profibus DP (Optional) Readout Device: Harsh environment, four line, 20 Character backlit LCD digital display Calibration: Push-button for In-Situ calibration to a known value for TSS Enclosure: NEMA 4X (IP65) Fiberglass 5.5 Lbs (2.5 kgms) 3

MODEL 7011A ANALYZER DIMENSIONS, RAIL KIT OUTLINE AND MOUNTING 8.45 TECHNOLOGIES MODEL 7011A TECHNOLOGIES MODEL 7011A DOOR SWING OUT 18.5 REQUIRED FOR MAINTENANCE 10 24X 1.00 LG S.S. PAN HEAD SCREW SUSPENDED SOLIDS ANALYZER 7.32 12.0 SUSPENDED SOLIDS ANALYZER FRONT VIEW 14.0 U BOLT FOR 2 HAND RAIL (2 SUPPLIED) 13.5 REQUIRED FOR MAINTENANCE SERIES 7110/7120 ANALYZERS 10.50 TECHNOLOGIES 10.50 10 24X 1.00 LG S.S. PAN HEAD SCREW MENU ENTER 9.37 TECHNOLOGIES WATER PROCESS ANALYZER 12.0 FRONT VIEW MENU ENTER 8.30 WATER PROCESS ANALYZER 1/4 20 UNC INSERT, 4 PLCS 0.31 CLEARANCE DRILL (4) 1/4 20 X 0.500 LONG PAN HEAD SCREWS SUPPLIED WITH MOUNTING KIT 14.0 BACK VIEW SIDE VIEW DOOR SWING OUT 18.5 REQUIRED FOR MAINTENANCE 18.5 U BOLT FOR 2 HAND RAIL (2 SUPPLIED) 13.5 REQUIRED FOR MAINTENANCE 13.00 NOTES: 1. CONSTRUCTION POLYCARBONATE NEMA 4X ENCLOSURE 2. APPROXIMATE WEIGHT: 6 LBS. 4

MODEL 72A LOW RANGE TSS SENSOR The Model 72A is for low ranges commonly experienced in effluent streams (10 1500 mg/l). It incorporates a unique automatic ambient light compensating technology that allows for clean water monitoring insitu, without requiring sample intake lines for reflection chambers. Automatic self cleaning is available. Type: Single Gap Optical 10 1500 mg/l Resolution: 1 mg/l Accuracy: ± 5% of reading or ± 5 mg/l, whichever is greater SENSOR MOUNTING The sensor cable is a 5 conductor shielded 22 AWG. It is available in 25 and 50 foot lengths as standard. A connector for quick disconnect to the monitor is provided as standard on the sensor and analyzer. The connector on the sensor is required when used with the JB-93 junction box. All Royce suspended solids sensors are equipped for an air or water jet cleaning. 1/4 AIR TUBING @ 60 PSI (TO COMPRESSOR ASSEMBLY OR SOLENOID VALVE) Repeatability: ± 1% of reading or ± 2 mg/l, whichever is greater Operating Limits: Temperature: 0 50ºC Pressure: 0 50 PSIG 1/4 AIR TUBING @60 PSI 1/4 COMPRESSION FITTING (ROYCE SUPPLIED) 1 1/2 PVC PIPE (CUSTOMER SUPPLIED) CABLE TO ANALYZER OR JUNCTION BOX ROYCE COMPRESSOR OR VALVE FOR HOUSE AIR/WATER PROBE PIPE MOUNTING BRACKET KIT 1-1/2 PVC PIPE (CUSTOMER SUPPLIED) Size: 4.5 inches square 3.87 5.5 Lbs (2.5 kgms) CLEANING JET Chemically resistant polyurethane optics in polyurethane housing FLOW DIRECTION 4.75 FLOW DIRECTION MODEL 72P FLOW THROUGH LOW RANGE TSS SENSOR The Model 72P is a low range, flow through version of the popular Model 72A. Commonly used in outfall plumbing of packaged WWTP s, portable potable water systems, backwash filter lines and other process water lines for the measurement of low level suspended solids. 10 1500 mg/l, Molded Epoxy/PVC Limits: Temp. 0 50ºC Pressure: 0 20 PSIG Optical: 3 Flanged Spool Mounted; Air or Water Jet Self-Cleaning 5

MODEL 72P SENSOR MOUNTING The sensor cable is a 5 conductor shielded 22 AWG. It is available in 25 and 50 foot lengths as standard. A connector for quick disconnect to the monitor is provided on the sensor and analyzer. The connector on the sensor is required when used with the JB-93 junction box. 7.6+.5 3 150# ANSI FLANGE (SCH. 80 PVC) 7.50 + 7.50 + + 2.90 All Royce suspended solids sensors are equipped for an air or water jet cleaning. SENSOR CABLE 1/4 OLD TUBING FOR JET CLEAN + + 6.00 MODEL 73B SUBMERSIBLE MLSS SENSOR The Model 73B submersible sensor is designed for mixed liquor suspended solids or MLSS typically found in aeration basins. This sensor uses phased array color compensation to correlate light absorption with suspended solids. Type: Single Gap, Optical; self cleaning. Model 73B has phased array emitter/receptor combination for automatic color compensation 300 3,000 up to 300 30,000 mg/l 0 3% The sensor cable is a 8 conductor shielded 22 AWG. It is available in 25 and 50 foot lengths as standard. A connector for quick disconnect to the monitor is provided on the sensor and analyzer. The connector on the sensor is required when used with the JB-93 junction box. All Royce suspended solids sensors are equipped for an air or water jet cleaning. Accuracy: ± 5% of reading or ± 100 mg/l, whichever is greater Repeatability: ± 1% of reading or ± 20 mg/l, whichever is greater Operating Limits: Temperature: 0 50ºC Pressure: 0 50 PSIG Size: 2.5 D x 3.3 L 12 ounces (.34 kgms) Chemically resistant polyurethane optics Molded polymer housing ROYCE COMPRESSOR OR VALVE FOR HOUSE AIR/WATER 1 1/2 PVC PIPE (CUSTOMER SUPPLIED) 6

MODEL 73P FLOW THROUGH MLSS SENSORS The Model 73P in-line MLSS sensor is common for use with in-line mixed liquor applications, septic waste influent applications, and packaged WWTP RAS, WAS MLSS and influent lines. Mid- Color Compensated; Pipe insertion; Air or Water Jet Self Cleaning 300 3,000 up to 300 30,000 mg/l, 0 3% Molded Epoxy/PVC Limits: Temp. 0 50º C Pressure: 0 20 PSIG MODELS 73P SENSOR MOUNTING The sensor cable is a 8 conductor shielded 22 AWG. It is available in 25 and 50 foot lengths as standard. A connector for quick disconnect to the monitor is provided on the sensor and analyzer. The connector on the sensor is required when used with the JB-93 junction box. All Royce suspended solids sensors are equipped for an air or water jet cleaning. 2.00 1/4 TO 1/3 DRAIN HOLE 1 1/2 (NPT) THREADS OR MALE ADAPTER 1/4 COMPRESSION FITTIN FOR JET CLEAN TUBING (ROYCE SUPPLIED) 1 1/2 FNPT TOP VIEW SAFETY CABLE 4.9 (73B) 4.7 (75A) PVC COUPLING 1.85 2.10 SEAL ASSEMBLY ROYCE SUPPLIED RUBBER SEAL FLOW FLOW DIRECTION INSERTION STOP NUT 7

MODEL 74A AND 76A HIGH DENSITY PIPE INSERTION SENSORS The Model 74A and 76A in-line sensors are used in WAS (Waste Activated Sludge) and RAS (Return Activated Sludge) line applications. These sensors offer automatic water Jet cleaning of the sensor optics by house supplied water. Type: Single Gap, Optical; self cleaning water jet 74A 800 8,000 up to 800 80,000 mg/l, 0-8% 76A 300 3,000 up to 300 30,000 mg/l, 0-3% Accuracy: 74A: ± 5% of reading or ± 150 mg/l, whichever is greater 76A: ± 5% of reading or ± 100 mg/l, whichever is greater Repeatability: 74A: ± 1% of reading or ± 30 mg/l, whichever is greater 76A: ± 1% of reading or ± 30 mg/l, whichever is greater Operating Limits: Temperature: 0 50ºC Pressure: 0 50 PSIG Size: 2 insertion D x 19 L 2 NPT male pipe insertion nipple 16 pounds (7 kgms) 316 SS insertion shaft and lens holders Chemically resistant polyurethane optics The sensor cable is a 8 conductor shielded 22 AWG. It is available in 25 and 50 foot lengths as standard. A connector for quick disconnect to the monitor is provided on the sensor and analyzer. The connector on the sensor is required when used with the JB-93 junction box. Cleaning connection supplied by Royce to house water is 3/8 compression fitting. Cleaning pressure must be 20 PSIG greater than line pressure. All Royce suspended solids sensors are equipped for an air or water jet cleaning MODELS 74A & 76A OUTLINE AND MOUNTING LENGTH OF PROTRUDING PORTION WITH SENSOR INSTALLED 17.63 12.6 LENGTH OF PROTRUDING PORTION WITH SENSOR REMOVED 14.5 ADDITIONAL CLEARANCE SPACE REQUIRED FOR SENSOR INSTALLATION AND REMOVAL MAXIMUM DISTANCE TO MIDDLE OF PIPE TO INSURE IMMERSION OF SENSOR = 5.78 SENSOR HEAD 8.0 BALL VALVE HANDLE IN OPEN POSITION (CLOSED = 9.0 SWING) FLOW FLOW CHECK VALVE (ROYCE SUPPLIED) 3/8 COMPRESSION (ROYCE SUPPLIED) 1.4 CONNECT 3/8 TUBING FOR CLEANING FLUID 2 NPT. X 3 LONG 3/8 S.S. NIPPLE 8

JB-93 JUNCTION BOX RAIL KIT OUTLINE AND MOUNTING MOUNTING ON EITHER HORITONTAL OR VERTICAL RAIL TECHNOLOGIES 8.5 4.9 Polystyrene NEMA 4X (IP65) Options: Rail Mounting Kit 4.9 8.5 JB-93: 2 Lbs With rail mount kit:.5 Lbs U BOLT FOR 2 HAND RAIL (2 SUPPLIED) 9

ROYCE JC SERIES COMPRESSOR ASSEMBLY FOR SUBMERSIBLE MLSS SENSOR JET CLEAN FOR OPTICS The sensor optics are Jet Cleaned by an air or water blast across the optics on a timed basis which is controlled by the parent instrument. Cleaning frequency and duration of the jet blast are programmed by the user to meet the demand of the application where optical surfaces are soiled by organic or biological fouling. All Royce suspended solids sensors are equipped for Jet Cleaning of the sensor optics by house supplied air or water using a solenoid. A minimum of 30 PSIG and a maximum of 60 PSIG is required for house air or water. The Royce Compressor Assembly is compatible with submersible MLSS sensors and is available as an option. The Model 74A and 76A in-line sensors can not use the Royce Compressor Assembly. An industrial grade high output compressor is used on all Royce JC Series compressor cleaning systems. By using the same compressor for multiple instrument sensors, the cost per sensor is drastically reduced. Any Royce analyzer can operate any JC Series compressor. In fact, a multi-channel JC-2 or JC-4 can be used on any combination of Royce dissolved oxygen or total suspended solids sensors at one time. The Models JC 1, 2, and 4 are all available in either 115 VAC or 230 VAC versions, and all electrical parts are CE certified. MODEL JC-1 COMPRESSOR SINGLE CHANNEL MODEL JC-4 COMPRESSOR FOUR CHANNEL Channels: One, Two or Four Compatibility: All Royce Analyzers Compressor Ambient Conditions: 0 to 70ºC -10 to 70ºC with optional heater Enclosure Dimensions: JC-1 14 W x 12 H x 6 D JC-2 or 4 17.5 W x 16 H x 10.5 D Door Hinges Up JC-1 26 lbs, 11.8 kgms JC-2 37 lbs, 16.8 kgms JC-4 40 lbs, 18.2 kgms Input Power: 115 VAC, 50 60 Hz or 230 VAC, 50 60 Hz +10% to -15% Outputs: Up to four, 1/4 push seal bulkhead connections Enclosure Protection: Vent port fitted TECHNOLOGIES MOUNT PANEL WITH 2 U-BOLTS ON HORIZONTAL RAIL, 1 U-BOLT ON VERETICAL RAIL U-BOLT FOR 2 DIA HANDRAIL MINIMUM OF 3 PLACES (3 SUPPLIED) BOTH POSITIONS SHOWN, ONLY ONE U-BOLT REQUIRED ON VERTICAL RAIL 10 Enclosure: NEMA 4X (IP65) COMPRESSOR OUTPUT 1/4 TUBING BULKHEAD FITTING 1/2 NPT CLEARANCE HOLE WITH PLUG, 2 PLACES

MODEL 711 PORTABLE SUSPENDED SOLIDS AND INTERFACE LEVEL ANALYZER.01 10 grams per liter (10 to 10,000 mg/l) Readout Device: Harsh environment, 1/2 LCD digital display Input Power: Standard 9V battery Enclosure: Waterproof Size: 7 L x 3.2 W x 1.5 D The Royce Model 711 Portable Suspended Solids/ Interface Level Analyzer is a rugged, waterproof instrument designed for the rigors of remote sampling. The meter provides reliable operation in waste treatment plants, rivers, lakes and other aqueous systems. The meter will read in either grams per liter when in the suspended solids mode or relative density percentage while in the interface level mode of operation. The Model 711 stores the calibration values for suspended solids and interface level in two separate nonvolatile memory locations allowing the user to switch between operational modes without having to recalibrate. The net effect is two analyzers in one. Due to the full utilization of the microprocessor, calibration values are stored so that recalibration is not required on a daily basis. If the sensor is cleaned after use, monthly calibration is usually more than sufficient for proper operation in either mode of calibration. The Model 711 analyzer utilizes the Model 71 medium range sensor. The Model 71 is a rugged, reliable sensing element that has polymer optical grade lenses. It was designed specifically to meet the rigorous demands that are a requirement for a portable sensor. SPECIFIC FEATURES Two analyzers in one package: Switch from Solids measurement to Interface level without losing calibration. Automatic ranging: Goes completely over the operating range of the analyzer with manual adjustment. Simple, insitu calibration. 1.5 pounds (.68 kgms) Type: Single Gap, Optical Accuracy: ± 5% of reading or ± 100 mg/l, whichever is greater Repeatability: ± 1% of reading or ± 20 mg/l, whichever is greater.01 10 g/l Operating Limits: Temperature, 0 65ºC Pressure, 0 º 50 PSIG Size: 4 L x 2 D 1 pound (.45 kgms) Polyurethane body Optical grade polymer lenses SUPPLIED STANDARD WITH MODEL 711 SYSTEM Model 711 rugged Suspended Solids analyzer Model 71 rugged SS sensor with 8 meters or 25 feet of cable and waterproof, military connector. Cable is scaled in one foot increments. Velcro grip strap which can convert to a handy belt holder. 9V battery. Detailed instruction manual. 11

What can ITT Water & Wastewater do for you? Integrated solutions for fluid handling are offered by ITT Water & Wastewater as a world leader in transport and treatment of wastewater. We provide a complete range of water, wastewater and drainage pumps, equipment for monitoring and control units for primary and secondary biological treatment, products for filtration and disinfection, and related services. ITT Water & Wastewater, headquartered in Sweden, operates in some 140 countries across the world, with plants in Europe, China and North and South America. The company is wholly owned by the ITT Corporation of White Plains, New York, supplier of advanced technology products and services. To find Royce products near you please visit: roycetechnologies.com ITT Water & Wastewater 14125 So. Bridge Circle Charlotte, NC 28273 Toll Free: 800-347-3505 Phone: 704-409-9898 Fax: 704-409-9899 Email: royce@itt.com VBR1009 (9/2009)