VAD03M-VPD03M- VMD03M

Similar documents
CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

CONTINENTAL HYDRAULICS F03MSV-ND* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F03MSV-ND* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

VEP03MSV-PDRP -3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

CONTINENTAL HYDRAULICS VED03MX

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

PILOT OPERATED PRESSURE RELIEF VALVE SERIES - IN-LINE MOUNTING

CONTINENTAL HYDRAULICS PVER VANE PUMPS

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Directional Control Valves

Pressure Control Valves

D05 Directional Control Valves

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

PowerFlow D03 Directional Control Valves

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

Q max (see specifications table)

Cartridge Valves Technical Information Directional Valves DCV 03

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Directional Controls

Pressure relief valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Available manual, pneumatic, and hydraulic spool control kits.

Directional Control Valve Series 4D01 (DENISON)

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

Documentatie Stuurventielen DL3

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Directional Controls

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Functional Description

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

ORV-M45. Contents. Additional Informations

Directional spool valve type WMM 16 hand lever operated

P.C. Priority Flow Control Valve Series J02D3. General Description

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Pilot-Operated Directional Control Valves Series D3 - D11

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Hydraulic gear pumps and motors

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

4.2 FIXED DISPLACEMENT DOUBLE PUMP

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Pressure reducing valve, direct operated

Model (kg) CIT CRG-06 CIT : CIT CRG-10 CIT : CIT CIT

Check valve, pilot operated

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Directional spool valves, direct operated, with solenoid actuation. Type WE

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Transcription:

CONTINENTAL HYDRAULICS VAD03M-VPD03M- VMD03M AIR, HYDRAULIC, LEVER OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM

PRECISE VAD03M-VPD03M-VMD03M AIR, HYDRAULIC, LEVER OPERATED DIRECTIONAL VALVES DESCRIPTION Continental Hydraulics offers directional control valves with air pilot actuation, hydraulic pilot actuation and lever actuation. These valves conform to NFPA D03 and ISO 4401 mounting standards. They are available in both 3 way and 4 way styles. All versions are available in 2 position spring offset, 2 position detent, 2 position spring centered and 3 position spring centered versions. The lever valve also is available in a 3 position detent model. A wide range of spools is available. TYPICAL PERFORMANCE SPECIFICATIONS MAXIMUM OPERATING PRESSURE MAXIMUM PILOT PRESSURE MINIMUM PILOT PRESSURE P - A - B Ports 5000 psi 350 bar T Port VA, VP 360 psi 25 bar T Port VM 3000 psi 210 bar VA 175 psi 12 bar VP 3000 psi 210 bar VA 60 psi 4 bar VP 215 psi* 15 bar* FLOW RATE 20 gpm 76 l/min MOUNTING SURFACE MAXIMUM WEIGHT NFPA D03 ISO 4401-03-02-0-03 VA, VP Single Op. 2.9 lbs 1.3 kg VA, VP Dual Op. 3.7 lbs 1.7 kg VM - Lever 4.6 lbs 2.1 kg *NOTE: The pilot pressure must be at least 215 psi (15 bar) above the T port pressure for the valve to shift properly. The pilot pressure circuit must be designed to allow the pilot pressure to drop rapidly to 0 psi to properly return the spool to its non-actuated position. RANGE TEMPERATURES FLUID VISCOSITY Ambient - 4 to +130 F -20 to +54 C Fluid - 4 to +180 F -20 to +82 C Range 60-1900 SUS 10-400 cst Recommended 120 SUS 25 cst FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15 2 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

IDENTIFICATION CODE V D03M - - - 10 - A P M OPERATOR Air Oil Lever FUNCTION FOR AIR AND OIL OPERATOR 1 2 FUNCTION FOR LEVER OPERATOR 2 Position Spring Offset A G Spool Type See Next Page SEAL Buna (STD) Viton R 90 MECHANICAL OMIT IF NOT REQUIRED DESIGN LETTER Operator Operator at B port end. Available only with function 1, 5 and 9. Also available on lever valve codes 3 and 4. Lever operator rotated 90 toward tank port. 2 Offset Position Detented (No Spring) 1 Single Operator 2 Position Spring Offset 3 3 Position Spring Centered 2 Dual Operator 2 Position Detented (No Spring) 4 3 Position Detented (No Spring) 3 Dual Operator 3 Position Spring Centered 5 2 Position Spring Centered 5 Single Operator 2 Position Spring Centered 9 2 Position - 3 Way Spring Offset NOTE: Spool code 9X must have the T port connected to tank. 9 Single Operator 2 Position - 3 Way Spring Offset 25 2 Position Detented (No Spring) TYPICAL ORDERING CODE: VAD03M-3A-A-10-B VPD03M-3A-A-10-A VMD03M-3A-A-10-B SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 3

SPOOLS NAME SYMBOL FUNCTION CENTER POSITION CROSSOVER FUNCTION MATCHING A A1 All ports blocked All ports closed P B or P A T blocked P B and A T restricted or P A and B T restricted 1, 2, 3, 4*, 5, 25* 3, 4*, 5, 25* B All ports open All ports open 1, 2, 3, 4*, 5, 25* E E1 F F1 G H J P and A blocked, and B T P and A blocked, B restricted to T P blocked, A T and B T P blocked, A and B restricted to T P to A and B T blocked P and A to T, B blocked P B A and T blocked All ports blocked or P and A blocked and B T All ports blocked or A blocked and B T restricted P blocked and A T or B T P blocked, A or B restricted to T P B or P A T blocked All ports open, restricted P B and A blocked or all ports blocked 3, 4*, 5, 25* K P and B blocked, and A T P and B blocked and A T or all ports blocked K1 P and B blocked, A restricted to T P blocked and A T restricted or all ports blocked L P T, A and B blocked All ports open, restricted N P A B and T blocked All ports blocked, or P A B and T blocked Q P and B to T, A blocked All ports open, restricted X - All ports blocked 2*, 9 AN - All ports blocked 2 (only VA and VP) AJ - All ports blocked 2 (only VA and VP) NOTES: 1. Functions marked with * are available with lever operator only. 2. AN and AJ spools are not available with lever operator. 3. These are the standard configurations. Contact Continental Hydraulics for special versions. 4 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

PRESSURE DROPS P-Q (OBTAINED WITH VISCOSITY OF 36 CST AT 50 C) SPOOL FLOW CURVE NUMBER SHIFTED CENTER P A P B A T B T P T A, A1, K1, F1, E1 2 2 3 3 B 1 1 3 3 2 E 2 2 3 1 F 3 3 1 1 G 1 3 1 3 H, Q 4 5 5 5 3 J 2 1 3 3 K 2 2 1 3 L 5 5 5 5 3 N 1 2 3 3 1A, 2A, 2AN, 2AJ 3 3 3 3 1A, 1B, 2A 2 2 2 2 9X 3 3 PERFORMANCE CURVE VAD03M, VMD03M CURVE SPOOL 1 A, A1, AN, AJ, B, E1, F1, G, k1, j, N, X 2 F 3 E, K, H, L, Q 4 L (only for VMD03M) VPD03M CURVE SPOOLS 2 A, F, 1B 3 B, L, X NOTES: 1. Valve performance was tested in a four way circuit (full loop). Performances may be reduced from that shown when used in a three-way circuit (half circuit), i.e. A or B port plugged. 2. The values have been obtained according to ISO 6403 norm with filtration according to ISO 4406:1999 class 18/16/13. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 5

OVERALL AND MOUNTING DIMENSIONS FOR PNEUMATIC AND HYDRAULIC OPERATOR VAD03M-2*, 3* VPD03M-2*, 3* Hexagon: 38 mm [1 ½ ] wrench Tightening torque: 25-30 lb.ft (35-40 Nm ) Dimensions in mm [IN] SAE 04 7/16-20 UNF connection for operator, hydraulic (VPD) or pneumatic (VAD) Mounting surface with sealing rings: 4 pcs. AS568-012 90 Shore A VAD03M-1*, 5*, 9 VPD03M-1*, 5*, 9 VAD03-1*-R, 5*-R, 9*-R VPD03-1*-R, 5*-R, 9*-R 6 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

OVERALL AND MOUNTING DIMENSIONS FOR LEVER OPERATED VALVE VMD03M Code 90 On 2- position valves push only to shift the valve. Dimensions in mm [IN] PUSH Mounting surface with sealing rings: 4 pcs. AS568-012 90 Shore A On 3- position valves, pulling the lever obtains the right position, pushing the lever obtains the left position. PUSH PULL PUSH PULL NOTE: the lever can be oriented by the user directly 180 turned to the standard position by uscrewing the lever and re-mounting it in the desired position. Lever operator at B Port end (not available with function 2 and 25) SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 7

APPLICATION DATA FLUIDS All pressure drops shown on these data pages are based on 170 SUS fluid viscosity and 0.87 specific gravity. For any other specific gravity (G1) the pressure drop ( P) will be approx. P1 = P (G1/G). See the chart for other viscosities. FLUID Cst 10 14.5 32 36 43 54 65 76 86 108 216 324 400 VISCOSITIES SUS 60 75 150 170 200 250 300 350 400 500 1000 1500 1900 MULTIPIER 0.77 0.81 0.97 1.00 1.04 1.10 1.15 1.20 1.24 1.31 1.56 1.72 1.83 Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than 180 degrees F causes the accelerated degradation of seals as well as the degradation of the fluids physical and chemical properties. From a safety standpoint, temperatures above 130 degrees F are not recommended. RANGE TEMPERATURES: Ambient - 4 to +130 F -20 to +54 C Fluid - 4 to +180 F -20 to +82 C FLUID VISCOSITY Range 60-1900 SUS 10-400 cst Recommended 120 SUS 25 cst FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15 INSTALLATION The configurations with centering and return springs can be mounted in any position without impairing correct operation. Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to or better than those indicated in the relative symbols. If minimum values are not observed, fluid can easily leak between the valve and support surface. 8 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

SEAL KIT Buna Seal Kit for VAD03M 1013311 Viton Seal Kit for VAD03M 1013312 Buna Seal Kit for VPD03M 1013313 Viton Seal Kit for VPD03M 1013314 Buna Seal Kit for VMD03M 1013315 Viton Seal Kit for VMD03M 1013316 BOLT KIT BD03-100 Valve only 121472 SUBPLATES AD03SPB8S Aluminium SAE-08 265801AU REAR PORTED DD03SPB8S Ductile SAE-08 265801AH AD03SPS8S Aluminium SAE-08 265801AP SIDE PORTED DD03SPS8S Ductile SAE-08 265801AI NOTES: 1. Max pressure for aluminum subplates: 3000 psi (210 bar) 2. Max pressure for ductile subplates: 5000 psi (350 bar) 3. Always verify subplate port size is proper for the application SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 9

ABOUT CONTINENTAL HYDRAULICS Rugged, durable, high-performance, efficient the reason Continental Hydraulics products are used in some of the most challenging applications across the globe. With a commitment to quality customer support and innovative engineering, Continental s pumps, valves, power units, mobile and custom products deliver what the markets demand. Continental has been serving the food production, brick and block, wood products, automotive and machine tool industries since 1962. Learn how our products survive some of the most harsh environments. SALES@CONTHYD.COM 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM FORM NO. 1013296. REV. 12/2011. 2011 CONTINENTAL HYDRAULICS. ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT NOTICE.