BRAKE TESTER DECELEROMETER

Similar documents
KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

MoistureMatch A next generation grain tester

The BOWMONK AFM2 is the modern day equivalent of a mechanical decelerometer such as the Bowmonk Brakemeter or Tapley Brake Meter.

User Manual Version AUTOSTOP Heavy I n V e h i c l e B r a k e T e s t e r

User Manual Version AUTOSTOP Maxi. I n V e h i c l e B r a k e T e s t e r

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SB-300 Operator s Manual

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Issue 2.0 December EPAS Midi User Manual EPAS35

Preparing and programming of ESGI 2 LPG supply system manual

INDEX. 1.Safety Precautions and Warnings...3

PowerView PV380-R2 Mechanical Configuration

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

SNMP dedicated to ORVALDI Solar Infini

BVA-350 Operator s Manual

KEMKRAFT ENGINEERING, INC. MODEL KEI-434 STEERING WHEEL TORQUE TESTER

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

CENTOR TORQUE GAUGE - EASY VERSION INSTRUCTION MANUAL. Version 1.3

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

EPAS Desktop Pro Software User Manual

MICROPROCESSOR BASED CONTROLLER

Service Manual for Volumetric Infusion Pump green stream ARGUS 707

CENTOR TORQUE GAUGE - STAR VERSION INSTRUCTION MANUAL. Version 1.3

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11

TORQUE CALIBRATION USING THE PROEDIT PROCEDURE WIZARD AND CALIBRATING USING PROCAL

Top quality Plug & weigh

Bante220 Portable ph Meter Instruction Manual

T100 Vector Impedance Analyzer. timestechnology.com.hk. User Manual Ver. 1.1

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

SmartON / SmartON+ Installation and Use Manual

Table of Contents. General Information...1. Components...2. Connection...4

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

TIMER INTERFACE USER MANUAL

Proline Prosonic Flow 93T Portable

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Online Capacity Tester MK70 User and PC-Software Manual

Advanced User Manual

Top quality For industrial use

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Support. EMROL Your power partner

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Slide Measuring Instrument GMG 200

RESISTIVE LOAD XP300C

OPERATION AND MAINTENANCE

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Grain Moisture Meter. Operators manual

After opening the printer drawer, the data plate is visible showing 'e1 84'. Any printer paper used must also show on the reverse side "e1 84".

Instruction of connection and programming of the VECTOR controller

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

1. Important Safety Warning

User s Manual XOB15091 OBD II / EOBD CODE READER. All Rights Reserved. Warranty and Service

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

FLUID CONTROL SYSTEM. No. 506-FCS EVERYTHING UNDER YOUR CONTROL FCS FULL OPTIONAL FCS BASIC ADVANCED FLUID MANAGEMENT SOLUTIONS

Rally computer 3 Rally computer 3.GPS *

BBT-205. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

12 VOLT BATTERY & ELECTRICAL SYSTEM ANALYSER

June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

1. OBD II Readiness Monitors An important part of a vehicle s OBD II system is the Readiness Monitors, which are indicators used to find out if all

Appendix 3 V1.1B Features

MDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

FORD EXP-1050 Vehicle Battery Diagnostic Platform. For testing 6 and 12 volt automotive batteries, and 24 volt electrical systems INSTRUCTION MANUAL

Everything under your control. No. 222/FCS ADVANCED FLUID MANAGEMENT SOLUTIONS FCS FULL OPTIONAL FCS BASIC

Sensormedics Vmax with ECG Tango M2 Interface Notes

BVA-200s Operator s Manual

Appendix 9: New Features in v3.5 B

MicroGuard 510 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

Section 55 Chapter 6

Computerscales DX Model Operating Instructions

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

P3 Electronic Brake Control

HIGH TECH SECURES YOUR FUTURE SBA 1200 GB SUN BRAKE ANALYSER. Operating Manual

2004, 2008 Autosoft, Inc. All rights reserved.

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

Operating Instructions Operating Instructions. HEKA testing lane UNIVERS "TX" 4cm above floor

CITIZEN. series. Precision Balances

Compression/Tension Testing Machines

TMD90A Dual Input Digital Thermometer

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Table of Contents. Chapter 1 Product Summary... 2

ORPscan20 Pocket ORP Tester Instruction Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

SUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL

USER S GUIDE. Installation & Operation Instructions. PORTAFLOW SE Ultrasonic Transit Time Flow Meter

User Manual Solar Charge Controller 3KW

Digital Transformer Ratiometer

Environmental Monitoring Microbial Air Sampling RCS High Flow Touch

Title: M.I.L. ON DTC P3191, P3190, AND/OR P0A0F Models:

Transcription:

OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch

2

Dear Customer, Thank you for ordering the Decelerometer OC 3010. The instrument has been carefully checked in all operation modes and finally precisely calibrated. The test chart is enclosed. WARRANTY The instrument has 24 month warranty for all parts and labour involved with the repair. The warranty does not apply to damaged, overloaded or modified instruments or instruments with broken seal at the rear cover. PLEASE NOTE The instrument is supplied from internal rechargeable NiMH battery. Please make sure that the battery is correctly charged from the enclosed battery charger as soon as the warning will appear at the display. The time for the full charge is approx. 3hours. We will be pleased to answer all your questions not only to this instrument but also to all our calibrators and measuring equipment. Please call our customer service or write to us info@orbitcontrols.ch Thank you. ORBIT CONTROLS AG Zürcherstrasse 137 8952 Schlieren Switzerland Tel: +41-44 - 730 27 53 Fax: +41-44 - 730 27 83 www.orbitcontrols.ch 3

Index Chapter 1 Page - Application and measurements 1.1 7 - Specifications 1.2 7 - Decelerometer accessories and options 1.3 8 - Principle of measurement 1.4 9 - Auxiliary Sensors 1.5 9 - Report printing 1.6 10 Chapter 2 - Control Panel and Configuration 2.1 11 - Configuration 2.2 13 - Calibration, Measurements and Printing 2.3 13 - Calibration 2.3.1 13 - Measurement 2.3.2 14 - Printing 2.3.3 14 - Menu Selection 2.4 15 - Data Clearing 2.4.1 15 - Recording Interval 2.4.2 16 - Six possibilities to initiate the measurement 2.4.3 17 - Threshold 2.4.4 18 - Display Contrast 2.4.5 18 - Backlight 2.4.6 18 - Time and Date 2.4.7 19 - Header of the report 2.4.8 17 - Filter 2.4.9 20 - Automatic Shut Off 2.4.10 20 - Basic Menu Settings 2.4.11 20 - Connection to a PC 2.5 21 - How to connect the PC and start communication 2.5.1 21 - Stability of the Measurement 2.6 25 - Additional languages 2.7 25 Chapter 3 - Service and Maintenance 3.1 26 - Battery Charging 3.2 26 - Replacement of paper and ink ribbon 3.3 26 4

Application Glossary Fast check up of brake systems of the traffic vehicles intended for: stations for the technical inspections of cars car repair shops car owners the benefit of judicial experts and police Type: Portable Decelerometer set with built-in printer, LCD display and keyboard, including the software for PC Windows. Optional connections of force sensor or pressure sensor are provided. Measured quantities: The measurement of the overall brake deceleration and its dependence on the controlling force applied to the brake pedal or its dependence on the air pressure in the air pressure brakes. The results of measurements are graphs of the time dependencies and the numerical calculated average value of the overall deceleration Specifications: Maximal braking deceleration... 10 m/s 2 Controlling force applied to the brake pedal... up to 1000 N (option) Air pressure in the air pressure brake... up to 1 MPa (option) Hydro pressure in the oil pressure brake... up to 20 MPa (option) Weight... up to 8T (option) Sampling rate 1..50s for OC3010 Sampling rate 5..300s for OC3010XL Printing graph with numerical values date and time of measurements company headings two lines of measurement confirmation 5

Power supply build in NiMH rechargeable battery. Charging from AC adapter. Measured data memory storage of 128 measurements. Possibility of printing any of the stored measurements. Decelerometer OC3010 accessories force sensor for the measurement of the force applied to the brake pedal pressure sensor for the air pressure measurement in the air pressure brake pressure sensor for the hydro pressure measurement in the Forklifts weight sensor for the load capacity measurement in the Forklifts AC adapter for charging of the NiMH battery external start button interface cable for connection to PC computer Software Program for Windows User s manual Carrying Case 6

Chapter 1 1.1 Application and measurements Decelerometer is used for measurements of overall brake decelerations of traffic vehicles. The value of deceleration is measured, as well as its dependence on the controlling force applied to the brake pedal, or its dependence on the air pressure in the air pressure brakes. The results of measurements are the graphical records time related the numerical calculated average value of overall deceleration and the average value of control force or the average value of air pressure. The following three options can be ordered: - Decelerometer only - Decelerometer with external sensor for controlling force applied to the brake pedal - Decelerometer with external sensor for air pressure in the air pressure brake system The measurement of the controlling force applied to the brake pedal and the measurement of the air pressure in the air pressure brakes is possible only with the external force sensor or with the external pressure sensor. After the selected sensor is connected, the Decelerometer will be configured automatically. The external sensors are supplied as accessories. External sensors from different Decelerometers are not exchangeable without the manufacturer s calibration. The measurement is very easy. The instrument must be placed onto the vehicle whereas the arrow on the instrument shows the direction of travel. With the levelling screws and built-in levelling libel the instrument is adjusted into exact horizontal position. After switching-on, the display scrolls the instructions. When the calibration is finished, the vehicle can be set into the motion. The measurement will start by pressing the starting button. Than the vehicle is slowed-down until it stops by its own braking system. The wheels are not allowed to block. The maximal values appear at the display and the detailed report is printed. The results of measurements will remain in the internal memory as long as the power is switched-on. 1.2 Specifications Design and specifications of the Decelerometer are based on the regulation of Ministry of transport, About regular technical inspections and emission measurements of the roadbound vehicles. Measurement Ranges: - Braking deceleration 0-20 ms -2 - Controlling force applied to the brake pedal 0-1000 N - Air pressure in the air pressure brake 0-1 MPa Accuracy of the measurements: - braking deceleration ± 3 % - controlling force applied to the brake pedal ± 35 N - air pressure in the air pressure brake ± 25 kpa. 7

Printing: - Company headings - Date and Time - Graphics with numerical values - Two lines containing the confirmation of measurement - Additional information about Decelerometer configuration Power supply: - build in NiMH rechargeable battery, charging from AC adapter Memory: - Internal memory for up to 128 measurements. Printing of any stored measurement Features: - Two line LCD display with back light - Keypad with 9 keys - Built-in matrix printer - Possible connection to PC with control and evaluation program 1.3 Decelerometer accessories and options The Decelerometer contains the microcontroller supported measuring circuits, set of options and accessories which facilitate the measurements: - Decelerometer OC3010 - External start button - AC adapter for NiMH battery - interface cable for connection to PC computer - CD with program for PC (Windows) - Extra paper for the printer - Users manual - Carrying Case Option (extra order) - Pressure sensor 1MPa with a cable - Force sensor 1000N with a cable - Pressure hydro sensor 20MPa with a cable - Weight sensor 8T with a cable The use of the pressure or the force sensor depends on the application. The interface cable to PC computer may be connected. The Decelerometer may be configured and used as stand alone unit or as a data acquisition system for collecting the data and transferring them to a PC. With the help of external start button the measurement can be initiated by the operator of the vehicle. 8

1.4 The principle of measurement The measurement is performed by simultaneous recording the deceleration and the controlling force applied to the brake pedal or by recording of the vehicle deceleration and the air pressure in the air braking system. All data are stored in the internal memory after the button Start has been applied. The measurement of the deceleration, the controlling force applied to the brake pedal and the air pressure in the air brakes is realised with the build-in deceleration sensor, the force sensor or the pressure sensor. At the end of the measurement the maximal values are shown at the display and a detailed report is printed. During the printing the calculation is performed for the average value of the overall deceleration, the average value of control force or the average value of the air pressure. Before the measurement starts, the recording interval has to be set. The range of setting is from 1 to 50 seconds (5 to 300 seconds for OC3010XL). An averaging filter is available with selectable filtering constants from 0 (no filter) to 10 (long time constant). The measurements can be initialized: - Starting button MEAS - External starting button - Setting the threshold value or combination of the above. The recording clearly shows whether the measured smallest average value of the overall deceleration is as prescribed in the vehicle manual and whether the controlling force applied to the brake pedal or the air pressure have achieved the required values. The results of measurements (up to 128 data sets) will be stored in the memory and might be printed. With the help of the supplied program, the records can be downloaded to a PC. After each measurement the Hydro sensor or the Weight sensor can be connected and used. Press the button MEAS again. After the display shows steady reading, press MEAS again. The pressure or weight measurements are stored. 1.5 Auxiliary Sensors For measurement of Forklifts the hydraulic sensor can be used connected to the forklift hydraulic installation. For weight measurement of the Forklifts an external weight sensor is optionally available. 9

1.6 Report printing When the measurements are stored, the report can be printed. The record contains the company s head (can be disabled), time and date, and the measured values and the time. The maximum deceleration value and the duration of the measurement will be printed as well. After entering the time interval, the average value of overall deceleration and the average value of the force or the air pressure will be calculated and printed. If Hydro sensor or Weight sensor is used, their results will be printed as well. Two lines of text are added to the printed report, containing the identification of the vehicle and the confirmation of the measurement. The printing on the 57.5mm wide paper is in ink. This will guarantee a long lasting quality. The printing of one report takes about 15 seconds. The report may be printed several times. The interval however in which the average values have to be calculated must be entered all the time. The reports of previous measurements may be printed more times as well. 10

Chapter 2 2.1 Control Panel and Configuration The Decelerometer OC3010 is controlled by using the front panel keyboard, with power- ON/OFF keys. Three keys are used in the measurement mode, four keys in the menu mode. With the keys ON and OFF the power is applied to the instrument. After the power is switched on, the display shows Brake tester *** ***Decelerometer The internal memory and the calibration data are tested. The time and date is displayed for 3 seconds, provided that the internal clock is set. After the test the following text will be displayed: Set horizont position, please The instrument has to be set into exact horizontal position with the help of levelling screws and built-in levelling libel. This step is mandatory in order to guarantee the correct function of the Decelerometer. Pressing of any key initiates the calibration, the setting of zero offset and starting of the configuration test. At the end the selected configuration is displayed for a short time. 11

Decelerometer only - Most of all applications: Decelerometer Decelerometer and external force sensor: Decelerometer Force sensor Decelerometer and external pressure sensor: Decelerometer Pressure sensor Decelerometer and external hydraulic sensor Decelerometer Hydr. sensor Decelerometer and external weight sensor Decelerometer Weight The instrument requests for switching into the measuring or the menu mode. Select function: Measure-menu Selection by MEAS or MENU. When a measurement has already been done, this information appears, e.g. with Decelerometer only: Measure N. 1 Max 9.8 m/s 2 12

Decelerometer and external force sensor: Measure N. 1 9.8 m/s 2 500N Decelerometer and external pressure sensor: Measure N. 1 9.8 m/s 2 300kPa When the Decelerometer is switched ON and OFF more time per day, the key MENU can be pressed to cancel the control procedure after the display shows: Brake tester *** ***Decelerometer 2.2 Configuration By pressing the appropriate keys in the mode measurement, the measurement, the calibration or the printing can be started, or the previous measurement can be displayed. By pressing MENU the menu mode is initiated - see 2.4. 2.3 Calibration, Measurements and Printing. 2.3.1 Calibration In the measuring mode the instrument measures, calibrates or prints the data. Any of these activities may be selected by depressing one of the keys MEAS, CAL or PRN. After pressing CAL the offsets of the deceleration sensor, the force sensor or the pressure sensor are set for zero reference values. Calibration Offset At the end of the calibration the display shows: End of Calibration 13

2.3.2 Measurement By pressing MEAS, the mode changes into measurement. The Display waits some seconds until the conditions for correct measurements are fulfilled. This time depends on the Decelerometer configuration, on the set threshold and on the mode how the measurement will be started. As soon as these conditions are met, the measurement starts and the results are recorded during the time interval set in the mode menu. The values of deceleration, force or pressure are calculated. The measured data are filtered in accordance with the filter setting. At the end of measurement the maximal values of deceleration, force or pressure are displayed as well as the serial number of the measurement. 2.3.3 Printing By pressing PRN, the paper will be advanced. When the key is pressed longer, the data will be printed in graphics. Papier eject or printing Printout For printing Push button Printing... Wait, please After the graphics is finished, the average values of overall deceleration, force or pressure will be printed. The beginning and the end of the time interval, in which the average values have to be calculated, must be entered with up or down arrow keys. The interval in which the deceleration is steady - nearly constant, has to be selected. start 0.8 s value 6.0m/s 2 14

The selected values have to be confirmed by pressing the right arrow cursor. The beginning of the interval is determined first. The end of the interval has to be confirmed afterwards. end 2.5 s value 3.4m/s 2 The average values of measured parameters are calculated within the selected interval only. The second part of the report is printed afterwards. By pressing MEAS again, the new measurement can be initiated. The previous measurements are not deleted, but stored in the memory. Up to 128 measurements can be memorized. By using the down arrow key the previous measurement can be recalled. With the up arrow key the next measurement can be started. The serial number of the selected measurement is displayed. The memory can store up to 128 measurements. Next measurements may be started as described in 2.4.1. 2.4 Menu Selection By pressing MENU the instrument enters the menu mode. In the Menu Mode the time interval, the recording, the starting way of the measurement, setting of the threshold, the display contrast, the backlight, the time and the date, the texts of the head, the transfer rate and the filter can be set by using the up the down and the right arrows. By pressing MEAS the measuring mode is initiated - see 2.3. 2.4.1 Data Clearing By pressing the key MENU following text appears: Data clearing N hh:mm:ss dd.mm With the key right arrow the measured data N (1...128), the time hh:mm:ss and date dd.mm will be deleted. All records 2 128 are shifted to 1...127. After erasing all data the following text will be displayed: *** No data ** ************ 15

All data can be deleted at the same time when the key right arrow is pressed for a longer time. All clearing push button When the key right arrow is pressed for a long time, the entire data content is erased. All clearing Watt. All clearing Clearing xx% The display is flashing during the data are erased. It takes around 5 seconds. When PRN is pressed, the paper is advanced. When pressed longer, the list of all stored measurements is printed. 2.4.2 Recording Interval After pressing the key MENU following text is displayed: Sample setting time : xx [s] With up and down arrows the recording interval can be set from 1 to 50 seconds (5 to 300 seconds for OC3010XL). 16

2.4.3 Six possibilities to initiate the measurement After pressing MENU one of the six possible ways of initiating the measurement can be selected. The selection is with up or down arrow keys. 1. Start with the key MEAS Start definition Internal= M 2. Start with the external button Start definition External=button 3. Start when the deceleration threshold is higher then the value set Start definition Decel. threshold 4. Start when the force/pressure threshold is higher then the value set Start definition Thr. force/pres 5. Start with external button and the deceleration threshold higher then the value set Start definition Butt + thres.dec. 6. Start with external button and force/pressure threshold higher then the value set Start definition Butt+thr.fr/pr 17

2.4.4 Threshold By pressing MENU the display will show: Threshold set Value: xx % By using the up and down arrows the threshold can be set in % from the upper limit XX. The upper limit of deceleration is 10 m/s 2, for the force 1000N and for the pressure 1MPa. The limit of deceleration, force or pressure will be selected in accordance with the configuration of the Decelerometer - see 1.1. 2.4.5 Display Contrast After pressing MENU the display will show: Contrast sel higher - lower Set the required contrast with up and down arrows. 2.4.6 Backlight After pressing MENU the display will show: Backgr. light on - off Set the required light with up and down arrows. With the backlight ON the operating time from the battery is much shorter. 18

2.4.7 Time and Date After pressing MENU the display will show: Time hh:mm:ss Date dd.mm.yyyy The flashing digit can be selected with the right arrow cursor. The value can be set with up and down arrows. 2.4.8 Header of the Report By pressing MENU the display will show: Line 1: Text line 1 Decelerometer OC The text is a factory default. Each line contains three parts. The bottom line contains one third of the text which is going to be printed. The text can be changed with the cursor keys or from PC by using the SW program enclosed. The exclamation mark at the first position on the line prevents the printing of the text. The letter being set is flashing. The cursor can be moved to the right only. After the first part of the first line is displayed, the entry of the second part of the first text line and then the third part of the first line can be performed. After the third part of the line is entered, the cursor will return to the first position of the line. The following three lines will be set similarly. By pressing MENU the next line will be enabled for entry. Write to EEprom Line 2: Text line 2 Orbit Controls Line 3: Text line 3 Switzerland 19

Line 4: Text line 4 orbitcontrols.ch 2.4.9 Filter By pressing MENU the display shows: Filter degree Value: 1 The filter degree can be set within the range 0 to 10 with up or down arrows. The higher the constant the smoother the graphics but the accuracy decays. 2.4.10 Automatic Shut-Off By pressing the key ON the instrument will energise. It switches automatically OFF when no further key is pressed. By regular operation the instrument switches-off after 10 minutes. 2.4.11 Basic Menu Settings The factory default settings are suitable for most general applications. Recording interval 5 s Initialising the measurement with the deceleration threshold Threshold value 20 % Display contrast higher Backlight YES Time and Date set in the factory Header of the report set in the factory Filter degree 1 After the setting the Decelerometer can be placed into the vehicle, switched-on and levelled into the horizontal position. The vehicle can be moved to the required speed, the key MEAS pressed. The vehicle can start to decelerate. When the vehicle stops due to the function of its own braking system, the report of the measurements will be printed. The recording time is 5 sec. The measurements will start at the beginning of the braking action. 20

2.5 Connection to the PC The software program for Windows is enclosed to each Decelerometer. The program starts by clicking on the icon OC3010. The communication with a PC is via the serial data port RS232. When only the recently stored data are processed and the Decelerometer shall not be reconfigured, the connection to the PC is not required. The communication between the Decelerometer and the PC is only in the measurement mode. It is not possible to connect the Decelerometer to the PC while performing the measurement. 2.5.1 Steps how to connect the PC and start the communication COM Setup COM Setup Click on the Icon to select COM - the Communication Port COM Setup Click on Find COM. The available Communication Port will open. 21

COM Setup Click on On line and than confirm with OK. COM Test COM Test Click on COM Test. The communication between OC3010 will be tested. COM Test Confirm with OK. 22

Record Upload Record Upload Select the Record Number Click on Record upload. The data will be transferred. The graphics and the parameters set during the measurement will be displayed. View Record View Click on View. All records will be shown as Preview Setup Menu Setup Four lines are available for free texts. Also all Parameters can be set. 23

Save Save the Notice Click on the Icon to open a Text File for saving the text. The text will appear down in the window. Save it in the opened file. The notice will appear at the bottom of the Graphics of Deceleration New Read Read Notice Click on the text file to open it. The notice will open at the bottom of the Graphics of Deceleration. New New text can be entered into the bottom field. The previous text will be erased. Printer Setup Printer Setup Print all Printer Setup 24

2.6 Stability of the Measurement The error free measurements are guaranteed for the ambient temperature 0 o C to 30 o C. The electronics, the deceleration sensor and the external sensors are factory calibrated. The accuracy described in 1.2 is guaranteed. The factory calibration constants are stored in the memory and are checked every time the power is turned on. When the stored parameters change, the display informs about the necessity of urgent recalibration. The Decelerometer with all accessories has to be returned to the factory for recalibration. 2.7 Additional languages Following languages are available: English, German, Spanish, Portuguese, Czech, and Slovak. The activation has to be consulted with the factory. Other languages are available upon request. 25

Chapter 3 3.1 Service and Maintenance The paper and the ribbon of the printer have to be replaced when necessary. The battery has to be charged with the enclosed battery charger (9V, 1.2A) in regular intervals. The printer is prone to dust environments. All repairs of the Decelerometer should be performed by the manufacturer. 3.2 Battery Charging When the message "Warning! It is time to charge the accumulator" is displayed, the battery has to be charged. When the battery voltage is bellow the limit, the backlight of the display is automatically switched off. When the instrument is not used for a longer time, the battery has to be fully charged. The battery has to be charged only when the Decelerometer is switched OFF. Do not use the Decelerometer switched-on with the battery charger connected. When the Decelerometer is switched-on and the battery charger is connected, the instrument automatically switches-off. The green LED flashes during the battery is being charged. With fully charged battery the LED lights continuously. The charging requires approx. 3 hours. The electronic prevents overcharging. The battery life expectation is about 1000 charging cycles. The battery has to be charged at the room temperature. The charging level may roughly be checked by pressing the right arrow cursor key at the time, when the display prompts to select the measurement or menu mode. When the key is pressed for longer time, the display shows the battery voltage. The fully charged battery shows 5.6 Volts. 3.3 Replacement of paper and ink ribbon. The paper of 57.5mm width can be replaced after the printer cover with label has been opened. When PRN is pressed, the paper is advanced. The proper function of the printer can be checked by pressing PRN for longer time. The head of the Report will be printed. To prevent the printing head matrix from the damage, it is recommended to use the wood free paper supplied by the manufacturer. The ink ribbon can be replaced after the paper has been removed from the printer. The cartridge will be shifted sideward by pressing at the point PUSH. The new cartridge can be inserted and the ribbon tightened by the notched wheel on the left side. Last update: September 2010 26