Powerful Solutions DHP - Introduction

Similar documents
The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Low Profile DC Power Supply with Zero Voltage Soft Switching

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

825-P Modular Protection System for motors Specification Guide

KEPCO Will Point You In The Right Direction!


RVS-DN Digital Reduced Voltage Motor Starter

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

RVS-DX Digital Reduced Voltage Motor Starter

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Switching Devices

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

PowerCommand 2100 digital generator set control

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Compact Sine Inverter

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

J1000. Compact Inverter Series.

Paralleling Equipment

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

ELECTRONIC LOAD CATALOG

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

VSD Series II Variable Speed Micro Drives

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

HVAC Products. Introducing the SED2 Variable Frequency Drives

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Panel Model Adjust Adjust Power 5Hz-1MHz 20MHz BW 5Hz-1MHz % Output Jacks Range Range (W) (mv) (mv) (ma) ( VAC) (Option)

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

HOBART Mobile diesel-driven 60 & 90 kva GPU Cummins QSB4.5 diesel engine ITW GSE Generator TIER 3 / EU STAGE 3A. It s all about connections

Description 1/8-7.5HP

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

SINAMICS GM150 IGCT version

Features. Description. Table of Contents

Sola/Hevi-Duty S3K Series Mini-Tower UPS

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Small size High power

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

A6Z OPERATING MANUAL

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

AT EVO SERIES BATTERY CHARGER

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

VariStroke II Electro hydraulic Actuator

PRODUCT SPECIFICATION File: EA-250U1C-10 Date: May, 25, 2005

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Technical Specification SENTINEL PRO

Diesel Generator Set S3.8 Series Engine

Features and Benefits. Control Features

Aurora Single Phase Emergency Lighting Inverters

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Sola 3000 Guide Specifications

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Softstarters Softstarters

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

Product Specifications

TerraSAS High-Performance 600V PV simulator

BIDIRECTIONAL DC/DC CONVERTER

Flight Systems. Replacement for KASSEC DESCRIPTION

IT8900 High Performance High Power Programmable DC Electronic Load

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

User Manual Solar Charge Controller 3KW

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

Constant Voltage/Constant Current Test System

SSI Technologies Application Note PS-AN3 MediaGauge Digital Pressure Gauges Product Overview

A3Z OPERATING MANUAL

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

CTi Automation - Phone: Fax: Web:

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Hp V AC Current Rating [A] 230V AC 60 Hz

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

EVO AT SERIES BATTERY CHARGER

SiCan Simple CAN Extension Charger to PacMon

Transcription:

Powerful Solutions DHP - ntroduction DHP - DC High Power Programmable Supply he DHP Family contains over 140 Tmodels ranging in output power from 2 kw to 30 kw in a single chassis. The 2 kw and 3 kw models are housed in a thin 2U (3.5 high), (19 wide) rackmount chassis. Programmable output voltages range from 5V to 600 VDC, delivering up to 3,000 amperes. This family has three operational modes, constant-voltage, constant-current and constant-power. The DHP Family uses second generation control technology for improved programmability and performance. This technology allows 9 auto sequence steps, each step can be up to 99,999 seconds in duration. Combining all the steps allows a maximum auto-step program 27.7 hours long. Various voltages, currents and durations can be programmed for each step. This family has standard analog and a variety of combinations of EEE-488.2, RS 232 and/or isolated analog input control interface options. All models come with the standard Sorensen 5-year warranty and CE Mark*. * All models up to and including 400V Features Modular Design: The series has a unique modular design that results in three rackmount profiles according to output power Unique Controls and Commands: Power-Off Memory: Enabling the input power and pushing the LAST SET button will restore the supply settings External Shutdown: An external shut down to inhibit the output Up/down arrows control voltages, step changes and current Digital Displays: Power supply rating power, voltage and current All power, voltage and current set points and limits Present and highest AC input voltage Present and highest air inlet temperature Power and auto-step sequence settings Calibration set-up Remote operation set-up Diagnostics fault status summary Protection and Safety Safe Power-Up: n the local mode, the output is disabled for additional safety at power up Front Panel Lockout: Most front panel controls are disabled when operated remotely Overvoltage, over-temperature, surge limit, soft start, brown out and short circuit protection CE Mark* 5 Year Warranty * All models up to and including 400V C US 19 Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com

DHP - Specifications OUTPUT age, Current, and : See tables Regulation (Line or Load) age: 0.1% of maximum rated output Current: 0.5% of maximum rated output Transient Response: 2 ms to steady state output voltage (within 2% of Vmax) for 30% step load change (slower response in paralleled systems) Stability: ±0.05% maximum rating per 8 hours after a 30 minute warm-up time at fixed line, load and temperature Efficiency: 80% minimum at full load Temperature Coefficient: 0.02%/ C of rated output voltage; 0.03%/ C of rated output current NPUT Standard age and Frequency 2-3 kw: 190-253 VAC, 47-63 Hz, single phase, 2-wire plus ground 5-15 kw and 16-30 kw: 190-253 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye input may be used (Wye does not require the neutral connection) GENERAL Operating Temperature: 0 C to +50 C, no derating Storage Temperature: -20 C to 70 C Cooling: nternal fan Front Panel Controls: Keypad to select/adjust voltage, current and power with non-volatile memories to store commonly used parameters Displays and ndicators: Back lit LCD alphanumeric display and LEDs Built-in Protection: Overtemperature, brown out, turn on surge limit, slow start, overvoltage (OVP resettable without recycling power) Remote Sense: The maximum line drop is 3% per line or 1V for 5-15V units, 3V for all others Remote Control/Monitor (Rear Panel): On/off control via contact closure, 6-120 VDC, 12-240 VAC, TTL or CMOS switch, output voltage and current monitor, (0-10 volt) OVP limit set, summary fault status nternal Programming: 9 memories are on-board for auto-step programming. Each step can be 1 second to 99,999 seconds or 27.78 hours long. Remote Digital Control Programming Resolution: age: 0.3% of full scale; Current: 0.3% of full scale; Overvoltage Protection: 0.5% of full scale (full scale is 110% of maximum output voltage) Programming Accuracy: age: 0.10% + 0.3% of maximum output voltage; Current: 0.3% + 0.3% of maximum output current*; Overvoltage Protection: 0.5% + 0.5% of maximum output voltage Readback Resolution: age and Current: 0.3% of full scale Readback Accuracy: age: 0.10% + 0.3% of full scale output voltage; Current: 0.3% + 0.3% of full scale output current* Soft Calibration: Calibration via front panel without removing chassis covers Software: LabVEW driver for M9D/M85, programs can be downloaded at no cost at www.elgar.com. Regulatory Compliance: CE mark, TÜV CUL (NRTL) mark Dimensions : 2U or 3-1/2" (88 mm) H x 19" (482 mm) W x 18" (457 mm) D : 3U or 5-1/4" (133 mm) H x 19" (482 mm) W x 22" (558 mm) D : 5U 10-1/2" (266 mm) H x 19" (482 mm) W x 22" (558 mm) D Weight: Maximum : 45 lbs. (22 kg) : 80 lbs. (55 kg) : 160 lbs. (73 kg) Shipping Weight: Maximum : 48 lbs. (23 kg) : 120 lbs. (73 kg) : 200 lbs. (91 kg) OPTONS & ACCESSORES Remote nterface Options M8: RS 232 internal remote serial interface M9D: nternal EEE-488.2 interface M10: Both EEE-488.2 and RS 232 M11: RS 232 and isolated analog programming M12: EEE-488.2 and isolated analog programming M14: EEE-488.2, RS 232 and isolated analog programming M17: Down programming option for 80V models: For maximum program down time and minimum repeat interval time values, consult the factory. M51: solated analog programming nput age Options M1**: 360-440 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye may be used M2**: 432-528 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye may be used M3: 190-253 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye may be used (3 kw models only) * After 30 minutes operation with fixed line, load and temperature ** Applies to all models 5 kw or greater Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com 20

Powerful Solutions DHP - Data Tables (2-3kW and 5-15kW) 2 kw to 3 kw s s Typical s Amps Typical 0-5 DHP 80-25 0-80 0-25 25 mv 0-8 10 mv DHP 80-37 0-80 0-37 25 mv 0-8 10 mv DHP 100-20 0-100 0-20 25 mv 0-10 10 mv DHP 100-30 0-100 0-30 25 mv 0-10 10 mv DHP 120-16 0-120 0-16 25 mv 0-15 10 mv DHP 120-25 0-120 0-25 25 mv 0-15 10 mv DHP 150-13 0-150 0-13 25 mv 0-20 10 mv DHP 150-20 0-150 0-20 25 mv 0-20 10 mv DHP 200-10 0-200 0-10 25 mv 0-30 0-66 10 mv DHP 200-15 0-200 0-15 25 mv 0-30 10 mv DHP 250-8 0-250 0-8 25 mv 0-40 0-50 10 mv DHP 250-12 0-250 0-12 25 mv 0-40 0-75 10 mv DHP 300-6.6 0-300 0-6.6 25 mv 0-50 0-40 10 mv DHP 300-10 0-300 0-10 25 mv 0-50 0-60 10 mv DHP 400-5 0-400 0-5 25 mv 0-60 0-33 10 mv DHP 400-7.5 0-400 0-7.5 25 mv 0-60 0-50 10 mv 5 kw to 15 kw DHP 5-1000 0-5 0-1000 10 mv DHP 20-500 0-20 0-500 10 mv DHP 5-1500 DHP 5-2000 DHP 5-2500 DHP 5-3000 DHP 8-800 DHP 8-1200 DHP 8-1600 DHP 10-660 DHP 10-1000 DHP 10-1300 DHP 12.5-530 DHP 12.5-800 DHP 12.5-1060 DHP 15-440 0-5 10 mv DHP 20-665 0-20 0-665 15 mv 0-5 15 mv DHP 25-265 0-25 0-265 10 mv 0-5 15 mv DHP 25-400 0-25 0-400 10 mv 0-5 15 mv DHP 25-520 0-25 0-520 15 mv 0-8 10 mv DHP 30-220 0-30 0-220 10 mv 0-8 10 mv DHP 30-330 0-30 0-330 10 mv 0-8 15 mv DHP 30-440 0-30 0-440 15 mv 0-10 10 mv DHP 40-166 0-40 0-166 10 mv 0-10 10 mv DHP 40-250 0-40 0-250 10 mv 0-10 15 mv DHP 40-330 0-40 0-330 15 mv 0-12.5 10 mv DHP 50-133 0-50 0-133 10 mv 0-12.5 10 mv DHP 50-200 0-50 0-200 10 mv 0-12.5 15 mv DHP 0-50 0-265 15 mv 0-15 10 mv DHP 10 0-60 0-110 10 mv DHP 15-660 0-15 10 mv DHP 0-60 0-166 10 mv DHP 15-880 0-15 15 mv DHP 60-220 0-60 0-220 15 mv DHP 20-330 0-20 0-330 10 mv continued on next page 21 Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com

DHP - Data Tables (5-15kW and 16-30kW) s Amps 5 kw to 15 kw (continued) Typical DHP 80-62* 0-62 mv DHP 80-125* 0-125 25 mv DHP 80-187* 0-187 25 mv DHP 100-50* 0-50 25 mv DHP 100-100* 0-100 25 mv DHP 100-150* 0-150 25 mv DHP 130-38* 0-38 25 mv DHP 130-76* 0-76 25 mv DHP 130-115* 0-115 25 mv DHP 150-33* 0-33 25 mv DHP 150-66* 0-66 25 mv DHP 150-100* 0-100 25 mv DHP 200-25* 0-200 0-25 25 mv DHP 200-50* 0-200 0-50 25 mv s Amps Typical DHP * 0-75 mv * 0-20 25 mv * 0-40 25 mv * 0-60 25 mv * 0-16 25 mv * 0-33 25 mv * 0-50 25 mv * 0-12 25 mv * 0-25 25 mv * 0-37 25 mv 600-11* 0-11 250 mv 0-16 250 mv DHP 600-22* 0-600 0-22 250 mv 16 kw to 30 kw DHP 8-2000 0-8 0-2000 25 mv DHP 100-200* 0-100 0-200 25 mv DHP 8-2400 0-8 0-2400 25 mv 100-250* 0-250 25 mv DHP 10-1650 DHP 10-2000 DHP 12.5-1325 DHP 12.5-1600 DHP 15-1100 DHP 15-1320 DHP 20-830 DHP 20-1000 DHP 25-650 DHP 25-800 DHP 30-550 DHP 30-660 DHP 40-415 DHP 40-500 DHP 50-330 DHP 50-400 DHP 60-275 DHP 60-330 DHP 80-250* DHP 80-312* DHP 80-375* 0-1650 25 mv 100-300* 0-300 25 mv 0-2000 25 mv 130-153* 0-153 25 mv 0-1325 25 mv 130-192* 0-192 25 mv 0-1600 25 mv 130-230* 0-230 25 mv 0-1100 25 mv 150-133* 0-133 25 mv 0-1320 25 mv 150-166* 0-166 25 mv 0-830 25 mv 150-200* 0-200 25 mv 0-1000 25 mv 200-100* 0-100 25 mv 0-650 25 mv 200-125* 0-125 25 mv 0-800 25 mv 0-150 25 mv 0-550 25 mv * 0-80 25 mv 0-660 25 mv 0-100 25 mv 0-415 25 mv DHP 250-120* 0-120 25 mv 0-40 0-500 25 mv DHP 300-66* 0-300 0-66 25 mv 0-50 0-330 25 mv DHP 300-83* 0-300 0-83 25 mv 0-50 0-400 25 mv DHP 300-100* 0-300 0-100 25 mv 0-60 0-275 25 mv DHP 400-50* 0-400 0-50 25 mv 0-60 0-330 25 mv DHP 400-62* 0-400 0-62 25 mv 0-80 0-250 25 mv DHP 400-75* 0-400 0-75 25 mv 0-80 0-312 25 mv DHP 600-27* 0-600 0-27 250 mv 0-80 0-375 25 mv DHP 600-33* 0-600 0-33 250 mv * Note: Turn on threshold is 2% of full scale in either voltage or current mode. Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com 22

Powerful Solutions DHP - and nput Connections #8-32 Threaded Studs 5-60 s Copper Bus Bars, Nickel Plated Dimensions: 1.5 x 0.75 x 0.18 Space Between Bus Bars: 2.125 Holes in Bus Bar: 0.375 Top View 80-400 s Two Position Terminal Block Front View Rear Panel Views nput Connections #10-32 Threaded Studs 5-60 s Copper Bus Bars, Nickel Plated Holes in Bus Bar: 0.390 80-600 s 0.375 Bronze Threaded Studs Top View Dimensions in inches (millimeters) Front View Rear Panel Views 23 Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com

AC CONTROL STATUS CONTSTANT VOLTAGE CONTSTANT CURRENT CONTSTANT POWER REMOTE DC CONTROL MENU LAST SET VOLTAGE CURRENT OVERVOLT 1 4 7. 2 5 8 3 6 9 0 CANCEL ENTER 13 25 6 5 1 18 14 TO ENABLE POWER SUPPLY CONNECT PN 5 TO PN 6 - EEE EEE EEE ADDRESS LOC/REM EEE ADDRESS LOC/REM DHP -, Options and Accessories 3.50 (88) 16.75 (425) nput Connections #10-32 Bronze Threaded Studs 5-60 s Copper Bus Bars, Nickel Plated Holes in Bus Bar: 0.410 J1 J2 J3 22.00 (558) 0.125 (3) Top View 80-600 s 0.625 Bronze Threaded Studs J1 J2 J3 OUTPUT: 100.0 VOLTS 100 AMPS 10.50 (266) DHP Series Dimensions in inches (millimeters) Options & Accessories 19.00 (482) Front View age M1* 360-440 VAC, 47-63 3 3-wire plus ground M2* 432-528 VAC, 47-63 Hz, 3 Phase, 3-wire plus ground M3** 190-253 VAC, 47-63 Hz, 3 Phase, 3-wire plus ground Remote nterface Options M8 RS 232 M9D EEE-488.2 M10 RS 232 and EEE-488.2 M11 RS 232 and Analog Programming (consult factory) M12 EEE-488.2 and solated Analog Programming (consult factory) M14 RS 232, EEE-488.2 and solated Analog Programming (consult factory) M51 solated Analog Programming (consult factory) age Down Programming Option M17 Down programming option for >80V models (consult factory) * Applies to all models 5 kw or greater **3kW only Rear Panel Views J1 Connector 1 Remote Enable 14 O 2 for Pins 1 and 14 15 nput 3 Remote OVP 16 Remote nput 4 V Return for Pins 9, 15 or 21 17 Fault State 5 Remote On/Off 18 Shutdown Fault 6 Circuit Common 19 age Monitor 7 Current Monitor 20 age Return for Pins 9, 15 or 21 8 Local age Control Monitor 21 age Control Resistance 9 Remote age Programming nput 22 Current Control Resistance 10 Current Programming nput 23 Current Return for Pins 10, 16 or 22 11 Control Monitor 24 Circuit Common C 25 Current Return for Pins 10, 16 or 22 C Phone: 858-450-0085 Toll Free: 800-733-5427 Fax: 858-458-0267 Europe: 0031 30 26 50 946 sales@elgar.com www.elgar.com 24