HIGH PRESSURE SODIUM. EYE Lighting Volume 6 Catalogue

Similar documents
Lamps CERAMIC METAL HALIDE

LAMPS - HIGH PRESSURE SODIUM

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

GE Lighting DATA SHEET. Product information. Features. Applications

Multi-Vapor Metal Halide Lamps

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

Lucalox Standard. GE Lighting. Product information. Applications areas

Arcstream Double Ended

Marine and Offshore Electrical Supply Pg 101. ORDERLINE Lamps FESTOON LAMP MINIATURE LAMP TAUNUS LAMP E5 PILOT LAMP BA5S PILOT LAMP

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

Smart Lamp Operating System

Solid State T8 tube is the smart alternative to a

Color Changing Pool Lamp

MasterColor CDM-R111 70W/830 10D 1CT

Pretest Module 15 Units 1, 2, 3, 4

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

GU10 3/5/7 LED Non-dimmable / Dimmable

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

GU10 3/6 LED Non-dimmable / Dimmable

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

PAR38 Waterproof IP65

Lighting Tables for New Equipment 7/16/2008

PAR20. 20W/35W Metal High Light Equivalent. V series /30 /35 /40

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Protected Spaces Philips TuffGuard Coated Lamps

Specification for 400W Industrial Highbay Luminaire and lamp

Lighting Tables for Existing/Base Equipment 4/15/2011

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

MR16 Narrow Spotlight Dimmable

Constant wattage for high intensity discharge (HID) lamps

Replacement. Metal Halide OB150S. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

Lighting Tables for Existing/Base Equipment 4/15/2011

AR111. M series. Base Type : G53 / Screw Terminal (ST) Input Voltage : 12V AC/DC LED Source : Nichia Total Power Consumption : 23W±10%

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

ConstantColor CMH MR16

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

PAR16/GU10 COB 35W Equivalent

GENERAL ALUMINIUM FLOODLIGHT For general area lighting

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

GU10/PAR16. EMC LVD ErP REACH. M II - Type

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Product Description. TL-D Standard Colours. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Bi-Pin G4 3 LED. M series. Base Type : G4.0 Input Voltage : 12V AC/DC LED Source : Nichia Beam Angle : 100 Total Power Consumption : 3.

Candle Light 30 Equivalent Non-dimmable / Dimmable

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

T5 Watt-Miser Linear Fluorescent lamps

STATIC DAYLIGHT PAR 575 VF

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

S35 30W / 40W Equivalent

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

Gavita HortiStar 600 SE EU

GE ConstantColor CMH StreetWise

ConstantColor CMH High Wattages

EMC LVD ErP REACH. V series SPOT & FLOOD - Low Voltage MR11 35W Halogen Equivalent

ConstantColor CMH MR16

HIGH INTENSITY DISCHARGE BALLASTS

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

Technical information. Lamp data Light tubes

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures.

Applications. Standard Materials. Certifications and Compliances

PLS LED. V series. Base Type : GX24Q / G23 Input Voltage : H:100~240V LED Source : Osram / EPISTAR Total Power Consumption :

N2MV Series W Non-metallic

PC T8 TEC, W PC TEC

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Increased Safety Mercury Lamp Lighting Fittings

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Product Description SON-T. Benefits. Features. Application. Versions. High Pressure Sodium lamp with clear tubular outer bulb

MR11 3 LED. V series SPOT & FLOOD - Low Voltage

MR16. 50W Equivalent. M series. Base Type : GU5.3 Input Voltage : 12V AC/DC LED Source : Nichia / Epistar Total Power Consumption : 8W±10%

ConstantColor CMH MR16 Ultra

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

Understanding Electronic UltraMax HID Ballasts

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

LIGHTING SPECIFICATIONS

FLOODLIGHTS. High Wattage. EYE Lighting Volume 6 Catalogue

Engineering Bulletin. Troubleshooting High Intensity Discharge Lighting Systems Metal Halide, Mercury, and High Pressure Sodium HID011R2

Lighting Tables for Existing/Base Equipment 1/1/2014

MR16. 35W Equivalent. EMC LVD ErP REACH. M series

Installation Instructions

Installation/Operating Instructions

Spiral T2 10,000 & 8,000 hours

Understanding Electronic UltraMax HID Ballasts

MR11-3 LED. EMC LVD ErP REACH. V series SPOT & FLOOD - Low Voltage

AFL FLOODLIGHT SERIES

CRYSTALGLO. Holophane s potted ballast provides good thermal dissipation and sound absorption, for long life and quiet operation.

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

Energy efficient low voltage dichroic mirror halogen reflector lamps

PAR16/GU10 COB. 50W Equivalent Ø50mm. EMC LVD ErP REACH. M series. Base Type : GU10 / E14 / E27 Input Voltage : H 100~240V / H2 200~240V LED Source :

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation.

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

GE ConstantColor CMH TM CMH SuperMini 20W & 35W

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Transcription:

HIGH PRESSURE SODIUM

Initial Sunlux ACE - BT & Elliptical Clear For use with Mercury Vapour Control Gear (IEC 60188) 120230 75 Clear Universal NH75-LX/70S 115 0.80 6500 2100 25 20000 86 E27 1 s 120235 115 Clear Universal NH110-LX 125 1.15 11600 2100 25 24000 100 E27 3 120240 235 Clear Universal NH220-LX 130 2.13 28000 2100 25 24000 119 E40 6 120245 375 Clear Universal NH360-LX 135 3.25 50000 2100 25 24000 133 E40 8 120330 940 Clear Universal NH940-LX 145 7.50 138000 2100 25 24000 146 E40 11 Sunlux ACE - BT & Elliptical Coated For use with Mercury Vapour Control Gear (IEC 60188) 120335 75 Coated Universal NH75F-LX/70S 115 0.80 6200 2100 25 20000 82 E27 1 120340 115 Coated Universal NH110F-LX 125 1.15 11000 2100 25 24000 95 E27 2 120345 150 Coated Universal NH150F-LX 130 1.50 15000 2100 25 24000 100 E40 4 120350 235 Coated Universal NH220F-LX 130 2.13 25500 2100 25 24000 108 E40 5 120355 375 Coated Universal NH360F-LX 135 3.25 46000 2100 25 24000 122 E40 7 120360 660 Coated Universal NH660F-LX 140 5.40 90000 2100 25 24000 136 E40 9 120365 940 Coated Universal NH940F-LX 145 7.50 131000 2100 25 24000 139 E40 10 ø116 ø116 ø150 98 178max. 178 max. 115 211 max. 226 max. 226max. 145 292max. 357 max. 395 max. B U R N IN G P O S IT IO N 292max. 185 395 max. 245 7.16 EYE.VOL6.L.v1

Sunlux ACE - Tubular For use with Mercury Vapour Control Gear (IEC 60188) Initial 120450 235 Clear Universal NHT220-LX 130 2.13 28000 2100 25 24000 119 E40 1 s 120455 375 Clear Universal NHT360-LX 135 3.25 50000 2100 25 24000 133 E40 2 120460 940 Clear Universal NHT940-LX 145 7.50 138000 2100 25 24000 146 E40 3 Beam Max. Light (cd) Sunlux ACE - Reflector For use with Mercury Vapour Control Gear (IEC 60188) 120400 75 Clear Universal NHR75-LX 115 0.80 3700 4400 1120 2100 25 16000 E27 4 120405 115 Clear Universal NHR110-LX 125 1.15 6200 7400 1900 2100 25 24000 E27 4 120410 235 Clear Universal NHR220-LX 130 2.13 120415 375 Clear Universal NHR360-LX 135 3.25 14000 20000 25500 34000 4500 2100 25 24000 E40 5 7300 2100 25 24000 E40 6 120420 660 Clear Universal NHR660-LX 140 5.40 55600 16500 2100 25 24000 E40 7 120425 940 Clear Universal NHR940-LX 145 7.50 85000 25000 2100 25 24000 E40 7 ø67 ø165 ø280 ø126 257max. 150 285 max. 175 222 375 max. 201 max. 310 max. 320 max. 410 max. B U R N IN G P O S IT IO N 7.17 EYE.VOL6.L.v1

Initial Ignitron - Elliptical For use with High Pressure Sodium Control Gear without ignitor (IEC 60662) 120550 50 Coated Universal NH50F/I 85 0.76 3800 2100 17 16000 76 E27 1 s 120556 70 Coated Universal NH70F/I 90 0.98 5800 2100 17 16000 82 E27 1 120570 100 Coated Universal NH100F/I 100 1.20 9500 2100 17 24000 95 E40 2 120575 150 Coated Universal NH150F/I 100 1.80 14000 2100 17 24000 93 E40 3 120580 250 Coated Universal NH250F/I 100 3.00 25800 2100 25 24000 103 E40 3 120585 400 Coated Universal NH400F/I 105 4.45 47800 2100 25 24000 119 E40 4 Ignitron - Tubular For use with High Pressure Sodium Control Gear without ignitor (IEC 60662) 120505 70 Clear Universal NHT70/I 90 0.98 6000 2100 17 16000 85 E27 5 120510 100 Clear Universal NHT100/I 100 1.20 10000 2100 17 24000 100 E40 6 120515 150 Clear Universal NHT150/I 100 1.80 14500 2100 17 24000 96 E40 6 120520 250 Clear Universal NHT250/I 100 3.00 27500 2100 25 24000 110 E40 7 120525 400 Clear Universal NHT400/I 100 4.60 50000 2100 25 24000 125 E40 8 120535 1000 Clear Universal NHT1000/I 100 10.60 133000 2100 25 24000 133 E40 9 186 max. ø75 226 max. B U R N IN G P O S IT IO N 285 max. ø120 104 211max. 127 ø35 257max. 153 287max. 175 375max. 240 ø67 7.18 EYE.VOL6.L.v1

Initial Sunlux - BT & Elliptical Clear For use with High Pressure Sodium Control Gear (IEC 60662) s - 400 Clear Universal NH400 105 4.45 50000 2100 25 24000 125 E40 3 120020 1000 Clear Universal NH1000 110 10.30 133000 2100 25 24000 133 E40 4 Sunlux - BT & Elliptical Coated For use with High Pressure Sodium Control Gear (IEC 60662) 120051 70 Coated Universal NH70F/HV/70H 90 0.98 5800 2100 17 16000 82 E27 1 120060 150 Coated Universal NH150F 100 1.80 14000 2100 25 24000 93 E40 2 120065 250 Coated Universal NH250F 100 3.00 25800 2100 25 24000 103 E40 2 120070 400 Coated Universal NH400F 105 4.45 47800 2100 25 24000 119 E40 3 120075 1000 Coated Universal NH1000F 110 10.30 125000 2100 25 24000 125 E40 4 Sunlux - Tubular For use with High Pressure Sodium Control Gear (IEC 60662) 120150 70 Clear Universal NHT70 90 0.98 6000 2100 17 16000 85 E27 5 120155 100 Clear Universal NHT100 100 1.20 10000 2100 17 24000 100 E40 6 120160 150 Clear Universal NHT150 100 1.80 14500 2100 25 24000 96 E40 6 120165 250 Clear Universal NHT250 100 3.00 27500 2100 25 24000 110 E40 7 120170 400 Clear Universal NHT400 100 4.60 50000 2100 25 24000 125 E40 8 120175 1000 Clear Universal NHT1000 100 10.6 133000 2100 25 24000 133 E40 9 Sunlux B lamp for use with Constant Wattage High Pressure Sodium Control Gear (IEC 60662) 120180 1000 Clear Universal NHT1000B 250 4.7 140000 2100 25 24000 140 E40 10 -- 153 max. 226 max. 285 max. 185 B U R N IN G P O S IT IO N ø120 395 max. 245 104 211max. 127 ø35 257max. 153 287max. 175 375max. 240 ø67 386max. 230 ø80 UPDATED: 09/10/2015 200

Sunlux - Reflector For use with High Pressure Sodium Control Gear (IEC 60662) 120150 100 Clear Universal NHR150 100 1.80 Beam 0-65 8500 9700 Max. Light (cd) 2200 2100 25 24000 E40 1 s 120155 250 Clear Universal NHR250 100 3.00 0-65 17400 19800 5500 2100 25 24000 E40 1 120160 400 Clear Universal NHR400 105 4.45 0-65 29800 33600 8600 2100 25 24000 E40 2 ø165 292 max. 315 max. B U R N IN G P O S IT IO N 7.20 EYE.VOL6.L.v1

WARNINGS AND CAUTIONS: HIGH PRESSURE SODIUM IN GENERAL OPERATING INSTRUCTIONS s Apply for: EYE Sunlux Ace EYE Improved Sunlux Ace EYE Sunlux EYE Ignitron 1. The lamp must have a suitable ballast, if it is connected directly to a power supply without a ballast, the lamp will instantly fail. This is an electric discharge lamp for use only with proper auxiliary equipment, compatible with electrical specifications (e.g. rated lamps watts, supply volts and frequency, etc) established by local authorities and the lamp manufacturer. Failure to comply with this may result in poor lamp performance and possible personal injury or property damage for which EYE Lighting will not be held responsible. 2. Do not touch hot lamps and keep away from any flammable goods during operation or immediately after the power is turned OFF. 3. Do not scratch bulb or subject lamp to undue pressure. This could result in lamp breakage. 4. When installing and replacing a lamp, power must be turned OFF to avoid possible electric shock hazards. 5. When the lamp has failed, replacement should be made as soon as possible after power is turned OFF. 6. When replacing a lamp, check the durability of the ballast, the wiring and the luminaire. If they have deteriorated, replace them with new ones immediately. 7. The lamp must have external protection against direct contact with water to minimise the possibility of glass bulb breakage with the exception of reflector type ones, unless otherwise noted. 8. This lamp is suitable for operation in any position. 9. For total supply load figures, add auxiliary watts to lamp watts. 10. When operating this lamp, the base temperature should not exceed 210 C (410 F) for E40 base and 190 C (374 F) for E27 base, the outer envelope should not exceed 400 C (752 F). Do not use this lamp in a fixture designed for less than the rated lamp wattage. 11. Do not use this lamp in a location subject to vibration or shock, unless an adequate vibration-proof fixture is used. 12. Do not use this lamp in a corrosive atmosphere, unless an adequate corrosion resistant fixture is used. 13. The recommended ambient temperature range for this lamp is -60 C (76 F) minimum; 50 C (122 F) maximum. 14. This is a discharge lamp and requires a certain time to restart and achieve full brightness after a power interruption. 15. Where lamps are to be operated continuously, they should be switched OFF and checked once a week for any abnormalities in order to prevent ballast damage or suitable protective measures should be taken to ensure that safety is maintained under this condition. 16. At the end of lamp life a number of lamps will exhibit a rectifying effect and the higher current will flow in the circuit. In order to prevent circuit damage, suitable protective measures should be taken to ensure safety is maintained. 17. Do not turn OFF within 1 minute after lamp starting in order to avoid re-start problems. EYE Sunlux Ace, EYE Sunlux Ace Improved. 1. EYE Sunlux Ace lamps should be operated on reactor type or autotransformer type ballasts for mercury lamps (IEC 60188 M.V.L. Ballast) which have an open circuit voltage below 265V. 2. The supply voltage should be kept to within ±6% of the rated supply voltage of the ballast. 3. The maximum wiring distances between the ballast and the lamp should be limited to: a) 50W and 75W: 1m. b) 110W: 15m. c) 220W and 360W: 25m. d) 660W and 940W: 50W. because of the reduction of pulse voltage. 4. Replace the lamp after the expiration of the rated life. Some lamps may continue to operate after their rated average life, however the lamps that are used after the rated average life do not perform as per specification. EYE Ignitron 1. EYE Ignitron should be operated on ballast for standard high pressure sodium (IEC 60662) without ignitor. EYE SUNLUX 1. EYE Sunlux lamps should be operated on a ballast for standard high pressure sodium (IEC 60662) lamps. 7.21 EYE.VOL6.L.v1