Mini contactors, relays, contactors

Similar documents
Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Manual Motor Protector with pushbutton actuation up to 25A. Trip-indicating auxiliary contact. Manual Motor Protector with rotary actuation.

Reliably Switching Highest Currents up to 2200 A

: Efficient solutions for motor control

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Reliably Switching Highest Currents up to 2000 A

: Efficient solutions for motor control

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Efficient solutions for motor control

Application Mini Contactors for Motors and Resistive Loads

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Application Mini Contactors for Motors and Resistive Loads

Price List July 2017

CI-TI Contactors and motor starters Types CI 61 - CI 98

Reliable Switchgear from One Proven Supplier

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Bulletin 100-D IEC Contactors

For Info: Phone: Fax:

Switchgear for Luminaires

Motor Applications Automation. Command and Signalling Power Management Product Overview for Machinery

Capacitor Switching Contactors Type K3...-A, K3...-K

Contactor Types CI 61-98

Controls. CONTACTORS CWB Line (up to 40A)

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Mini Contactors CI 4-

Industrial Contactors CTX 3 3P 185A - 800A

Page 2-4 Page 2-8. Page Page 2-13

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Technical Information

Modular contactor for installation into distribution boards

W Datasheet: DIN Rail Contactors, series AMPARO

Page 2-4 Page 2-8. Page Page 2-12

AF series contactors (9 2650)

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Flexible. Intelligent. Trendsetting.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

CI-TI Contactors and Motor Starters Type CI 6-50

AF series contactors (9 2650)

Technical Information

ABB s new control and protection devices

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

CA Z-EN Overload relays, CT-operated overload relays

Modular contactors and relays

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Switches Unlimited Phone: * Fax:

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

Short form catalogue. Motor protection & control

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

US Catalog. Motor protection and control AF Range contactors & overload relays

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

and Refrigeration Institute). CNX Special Purpose Contactors

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Installation Contactors RIC, RAC

Series CA5 Contactors

Short form catalogue Motor protection and control Block contactors and overload relays

Essential equipment for all your requirements

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Technical Information

Micro Contactor MA Series

4 - Miniature controls

3RT14 Contactors with 3 Main Contacts

CWM_N NEMA Rated Contactors

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

High Reliable Components for Power Factor Correction and Power Quality

BETA Switching Switches and Light Indicators

AF09... AF96 3-pole contactors Accessory fitting details

Self-protected Combination Starters System PKZ 2-SP

PKZ and PKE motor-protective circuit-breakers

Siemens AG Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12 SIRIUS. Catalog Add-On IC 10 AO. Edition Answers for industry.

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Partnership that you can trust. LV Switchgear Motor Control Products.

AF40... AF96 3-pole contactors Technical data

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Leadership driven by innovation

Electronic Ballast EVG 2000-T

About us. Switchgear Factory, Mumbai

Training & Didactic Systems. Fundamentals of Electrical Engineering

VSMeasy Wiring Systems and Motor Starter Combinations

BETA Switching Switching Devices

ASL09..S 3-pole Contactors - Spring Terminals

AE 9... AE 40 Contactors NE... Contactor Relays

General Catalogue. Quality made in D946E173

Motor-protective circuit-breakers PKZ: now better than ever

Transcription:

Contents 5/1 Moeller HPL011-007/008 Mini contactors, relays, contactors Continual operational availability requires a high operational reliability from the devices used. DILM contactors not only have the best lifespan values for standard AC-3 but are also exceptionally suited for the heavier AC-4 inching duty. Therefore the safety of the machine is increased also during the set up and changeover phases. AC and DC contactor system xstart Relays and contactors up to 170 A AC 3 at 400 V - Identical frame sizes for AC and DC operated contactors simplify the engineering - Minimised heat dissipation allow a higher packing density in the control panel - Higher wiring safety due to double box terminals - Less intermediate relays because contactors up to 3 A can be directly actuated from the PLC - Simplified engineering due to integrated suppressors in the DC operated contactors Page 5/16 Mini-contactors DILER, DILEM Ordering DILA relays Page Relays, contactors 5/ Auxiliary contact modules 5/4 Accessories 5/6 Actuating voltages 5/51 Ordering Relays 5/8 Auxiliary contact modules 5/10 Actuating voltages 5/5 Lighting contactors DILL Page Ordering 5/34 Engineering Switchgear for lighting systems 5/35 Contactor combinations SDAINL, DIUL Ordering Star-delta combinations 5/36 Engineering Star-delta combinations 5/38 Ordering Mini contactors, relays, contactors Engineering Page Contact travel diagrams 5/60 Enclosures 5/61 for resistive loads 5/6 Electrical lifespan 5/ Short-time loading 5/67 Operating frequency 5/68 Switching of DC current 5/69 Technical data Mini contactor relays and relays 5/70 Contactor monitoring device 5/73 up to 170 A 5/80 Mini contactors, relays, contactors Reversing combinations 5/40 larger than 170 A 5/88 for capacitors 5/96 Technical overview 5/1 CMD contactor monitoring device up to 150 A with electronic actuation 5/98 System overview 5/ Ordering Description 5/49 Ordering 5/50 Lighting contactors 5/100 Auxiliary contact modules 5/101 Accessories 5/10 Basic units up to 170 A 5/16 Dimensions Basic devices up to 170 A with 5/18 springloaded terminals Complete units up to 170 A 5/0 Basic units up to 150 A with 5/ electronic actuation Comfort devices greater than 170 A 5/4 Standard devices greater than 170 A 5/6 Auxiliary contact modules 5/8 Engineering Accessories relays, contactors Ordering Suppressors 5/4 Accessories 5/43 Actuating voltages contactors Mini contactor relays 5/103 Relays 5/104 up to 170 A 5/104 larger than 170 A 5/106 for capacitors 5/108 Lighting contactors 5/108 Contactor combinations 5/109 Accessories 5/110 High rated contactors up to 1600 A AC-3 at 400 V, up to 000 A AC-1 - Smaller size and higher lifespan due to vacuum technology from 580 A - Direct actuation from PLC saves intermediate relays - Simple engineering due to wide-range coils - Minimised heat dissipation reduces costs for the control panel ventilation Page 5/4 Auxiliary contact modules 5/31 DILK contactors for capacitors Ordering 5/3 Engineering for power factor correction 5/33 Ordering 5/35 Basic units up to 170 A 5/53 Basic devices up to 170 A with 5/56 springloaded terminals Basic units up to 150 A with 5/58 electronic actuation Replacement coils 5/57 Comfort devices greater than 170 A 5/59 Standard devices greater than 170 A 5/59 Electronic modules including coil 5/59 for capacitors 5/58

5/ Ordering, relays Ordering, relays 5/3 DILER, DILEM Moeller HPL011-007/008 DILER, DILEM Connection technique Rated operational current AC 15 Conventional thermal current Contacts N/O = 0 V 380 V Normally open 30 V 400 V 40 V 415 V N/C = Normally closed Distinctive number Contact sequence can be combined with auxiliary contact AC operation DC operation Std. pack Part no. Part no. Mini contactor relays DILER mini contactor relay I e e th A A A 6 3 10 4 N/O 40 E A1 13 3 33 43 DILE DILER-40(30V50HZ) 051759 3 N/O 1 N/C 31E A1 13 1 33 43 DILER-31(30V50HZ) 051768 N/O N/C E A1 4 13 1 34 34 31 3 44 44 43 44 051777 DILE DILER-40-G(4VDC) off DILE DILER-31-G(4VDC) 010157 01004 Mini contactor relays Page a a Further actuating voltages a 5/51 Contacts according to EN 50011 Coil terminal markings to EN 50005 With DC operation: integrated resistance-diode combination, coil consumption.6 W. With DC operation: integrated diode-resistor combination, coil rating.6 W Rated operational current Max. rating for three-phase motors, 50 60 Hz Conventional thermal current th = e AC-1 Contacts AC-3 AC-3 AC-4 N/O = 30 V 690 V 30 V 690 V Open Enclosed Normally open N/C = Normally closed Contact sequence For use with Article no. see price list Article no. see price list Std. pack e P P P P P P I th = I e I th = I e A kw kw kw kw kw kw A A DILEM 3-pole, with auxiliary contacts A1 1 3 5 13 Screw 9. 4 4 1.5 3 3 0 16 1 N/O...DILEM DILEM-10(30V50HZ) 1 N/C A1 1 3 5 1 terminal s 9. 4 4 1.5 3 3 0 16...DILE...DILE 051786 DILEM-01(30V50HZ) 051795 4-pole Screw terminal s 9. 4 4 1.5 3 3 0 16 A1 1 3 5 7...DILEM...DILE 8 DILEM4(30V50HZ) 051804 DILEM-10-G(4VDC) 01013 DILEM-01-G(4VDC) 010343 DILEM4-G(4VDC) 01701 1 off With screw terminals: 3 1 Accessories 1 Overload relay a 6/5 Suppressor a 5/6 3 Auxiliary contact modules a 5/5 Enclosure Other actuating voltages a 5/5 Accessories a 5/6

5/4 Ordering Auxiliary contact modules Ordering Auxiliary contact modules 5/5 DILE Moeller HPL011-007/008 Moeller HPL011-007/008 DILE Mini contactor relays Connection technique Auxiliary contact modules Screw terminals Contacts N/O = Normally open N/C = Normally closed Rated operational current Conventional thermal current Distinctive number/style of combinations with base unit AC 15 DILER-40(-G) DILER-31(-G) DILER-(-G) 0 V 30 V 40 V 380 V 400 V 415 V I e I e I th A A A Contact sequence Can be combined with contactor -pole N/C 4 10 1 31 DILEM-10(-G) DILEM-4(-G) 0DILEM 0100 3 1 N/O 1 N/C 1 33 11DILEM 010080 4-pole N/O N/C 1 31 43 53 DILEM 01011 -pole N/C 4 E 33 4 51 61 5 6 DILEM-10(-G) DILEM-01(-G) DILEM-4(-G) 0DILE 01040 1 N/O 1 N/C 51 E 4 33 53 61 DILER40(-G) DILER31(-G) 11DILE 0104 5 DILER N/O 60 E 51 4 53 0DILE 01008 Part no. Article no. 1 N/O E 1 N/C L 51 4 33 57 65 11DDILE 04984 54 3 58 34 66 44 54 see Std. pack 5 off Contacts of the auxiliary contacts:...dilem according to EN 5001...DILE according to EN 50005 Contacts according to EN5001 are to be prefered. Version E combinations correspond to EN 50011 and are to be preferred. Auxiliary contact modules with positive acting contacts No postive action with early-make and late-break contacts NO E : early-make NO contact NC L : late break NC contact Mini contactor relays 4-pole 4 N/C 44 E 35 6 51 61 71 81 04DILE 01056 5 6 7 8 1 N/O 3 N/C 53E 44 35 53 61 71 81 13DILE 00397 N/O N/C 6E 53 44 53 61 71 83 DILE 01088 3 N/O 1 N/C 71E 6 53 53 61 73 83 31DILE 04891 4 N/O 80E 71 6 53 73 83 40DILE 010304 1 N/O, 1N/C, 1 N/C L 6 53 44 57 65 71 83 DDILE 1 N/O E 04983 54 54 54 54 58 6 6 6 7 7 74 74 66 7 8 84 84 84 84

5/6 Ordering Accessories VGEDILE, RCDIL Moeller HPL011-007/008 Actuating voltage Contact sequence For use with contactor relays Part no. Article no. see Std. pack Note concerning the product U s V AC Mini contactor relays Suppressors Varistor suppressor 4 48 A1 DILE... VGDILE48 01030 110 50 VGDILE50 010336 380 415 VGDILE415 0104 10 off For AC-operated contactors 50 60 Hz. DC operated contactors have an integrated suppressor. Note drop-out delay RC suppressor 4 48 A1 DILE... RCDILE48 044 110 50 RCDILE50 040 10 off For AC-operated contactors 50 60 Hz. Note drop-out delay 10 off For use with Part no. Article no. see Std. pack Spacers For mechanical connection of contactor, relays and timing relays in combinations DILE... DILET... Mechanical interlock DILE... V0DILE 064 MVDILE 010113 50 off 0 mm distance between relays 5 off With contactors with the same or different magnet system the distance between contactors 0 mm, mechanical lifespan.5 x 10 6 operations, additional auxiliary contact modules can be fitted. Paralleling link For auxiliary contacts DILE DILE BT480 05785 100 off Not protected against direct contact in accordance with IEC 536 Blade terminal to DIN 44 For contacts and coil connections 1 x 6.3 x 0.8/ x.8 x 0.8 mm DILEM, DILM17 DILM1000 DILE DILET M-K BT483 059904 100 off Use insulated ferrules to DIN 45. Sealable shrouds transparent DILE... DILET... HDILE 01048 1 off For latching on the contactor. For use open or in the service distribution board. Degree of protection: IP40 front

Ordering Accessories 5/7 Moeller HPL011-007/008 DILEM, MVS- For use with Contact sequence Part no. Article no. see price list Std. pack Star-point bridge Paralleling links Consisting of paralleling links 4-pole DILEM DILEM S1DILEM 018 P1DILEM 019095 Reversing wiring set Main current wiring for reversing combinations DILEM (+MVDILEM) MVS-WB-EM 009 0 off Protected against direct contact in accordance with IEC 536 5 off 4th pole can be broken off 4-pole: I th = 60 A open 3-pole: I th = 50 A open AC-1 current carrying capacity of the open contactor increases by a factor of.5. Protected against accidental contact in accordance with IEC 536. 1 off The following control cables are integrated in addition to electrical interlock: K1M: A1 KM: 1 K1M: 1 KM: A1 K1M: KM: When combined with overload relay use separate mounting. Mini contactor relays Star-delta wiring kit Main current wiring for star-delta combination incl. star-point bridge Mains contactor DILEM Delta contactor DILEM Star contactor DILEM MVS-SB-EM 013 1 off The following control cables are integrated in addition to electrical interlock: K3M: A1 K5M: 1 K3M: 1 K5M: A1 K3M: K5M: When combined with overload relay use separate mounting.

5/8 Ordering Contactor relays, contactors Ordering Contactor relays, contactors 5/9 DILA Moeller HPL011-007/008 Moeller HPL011-007/008 DILA Contactor relays Connection technique Contacts Rated operational current Conventional thermal current N/O = Normally open N/C = Normally closed AC 15 0 V 30 V 40 V 380 V 400 V 415 V I e I e I th A A A Code number Can be combined with auxiliary contact module Contact sequence AC operation Std. pack Contact sequence Part no. Article no. Basic device: with forced operation contacts A1 13 3 33 43 Screw 4 N/O 6 4 16 40E DILA-XHI(V)... DILA-40(30V50HZ) terminals 79 see price list DC operation Std. pack Part no. Article no. 1 off A1 13 3 33 43 DILA-40(4VDC) 744 4 34 44 4 34 44 see price list 1 off With screw terminals: Contactor relays 3 N/O 1 N/C 31E DILA-XHI(V)... A1 13 1 33 43 DILA-31(30V50HZ) 7 34 44 34 44 N/O N/C E DILA-XHI(V)... A1 13 1 31 43 DILA-(30V50HZ) 799 A1 13 1 33 43 A1 13 1 31 43 3 44 3 44 DILA-31(4VDC) 779 DILA-(4VDC) 7 1 Accessories Page 1 suppressor a 5/4 auxiliary contact modules a 5/11 Further actuating voltages a 5/5 Contacts according to EN 50011 Coil terminal markings to EN 50005 DC operated contactors have a built-in suppressor circuit. Spring-loaded terminals A1 13 3 33 43 A1 13 3 33 43 4 N/O 6 4 16 40E DILA-XHIC(V)... DILAC-40(30V50HZ) 1 off DILAC-40(4VDC) 741 756 4 34 44 4 34 44 1 off With spring-loaded terminals: 3 N/O 1 N/C 31E DILA-XHIC(V)... A1 13 1 33 43 DILAC-31(30V50HZ) 773 34 44 34 44 N/O N/C E DILA-XHIC(V)... A1 13 1 31 43 DILAC-(30V50HZ) 76505 A1 13 1 33 43 A1 13 1 31 43 3 44 3 44 DILAC-31(4VDC) 788 DILAC-(4VDC) 7650 1 Accessories Page 1 suppressor a 5/4 auxiliary contact modules a 5/11 Further actuating voltages a 5/5 Contacts according to EN 50011 Coil terminal markings to EN 50005 DC operated contactors have a built-in suppressor circuit.

5/10 Ordering Auxiliary contact modules Ordering Auxiliary contact modules 5/11 DILA XHI Moeller HPL011-007/008 Moeller HPL011-007/008 DILA XHI Connection technique Contacts N/O = Normally open N/C = Normally closed Rated operational current Conventional thermal current Contact sequence Code number and version of combination AC 15 DILA(C)-40 DILA(C)-31 DILA(C)- 0 V 30 V 40 V 380 V 400 V 415 V Part no. Article no. see price list Std. pack Contactor relays I e I e I th A A A DILA auxiliary contact modules With interlocked opposing contacts (exception:...xhi(c)v...) 51 61 Screw pole N/C 6 3 16 4 E 33 4 DILA-XHI0 terminals 70 5 6 1 N/O 1 N/C 53 61 51E 4 33 DILA-XHI11 71 54 N/O 53 60E 51 4 DILA-XHI0 7 6 54 5 off Version E combinations correspond to EN 50011 and are to be preferred; other combinations correspond to EN 50005 The DC operated contactor DILA(C)- must only be combined with pole auxiliary contacts. NO E : early-make NO contact NC L : late break NC contact Contactor relays 1 N/O E 1 N/C L 57 65 51 4 33 DILA-XHIV11 73 58 66 4 pole 4 N/C 51 61 71 81 44E 35 6 DILA-XHI04 74 5 6 7 8 1 N/O 3 N/C 53 61 71 81 53E 44 35 DILA-XHI13 75 54 N/O N/C 53 61 71 83 6E 53 44 DILA-XHI 76 54 3 N/O 1 N/C 53 61 73 83 71E 6 53 DILA-XHI31 77 54 4 N/O 53 73 83 80E 71 6 DILA-XHI40 78 54 6 6 6 7 7 74 74 8 84 84 84 1 N/O, 1 N/O E 1 N/C, 1 N/C L 57 65 71 83 6 53 44 DILA-XHIV 79 58 66 7 84 springloaded terminals pole N/C 51 61 4 E 33 4 DILA-XHIC0 7656 1 N/O 1 N/C 53 61 51E 4 33 DILA-XHIC11 7657 N/O 53 60E 51 4 DILA-XHIC0 7658 1 N/O E 1 N/C L 57 65 51 4 33 DILA-XHICV11 7659 4 pole 4 N/C 51 61 71 81 44E 35 6 DILA-XHIC04 76530 5 6 5 54 58 66 5 6 7 8 1 N/O 3 N/C 53 61 71 81 53E 44 35 DILA-XHIC13 76531 5 7 8 N/O N/C 53 61 71 83 6E 53 44 DILA-XHIC 7653 5 7 84 3 N/O 1 N/C 53 61 73 83 71E 6 53 DILA-XHIC31 76533 5 74 84 4 N/O 53 73 83 80E 71 6 DILA-XHIC40 76534 54 74 84 1 N/O, 1 N/O E 1 N/C, 1 N/C L 57 65 71 83 6 53 44 DILA-XHICV 76535 58 66 7 84

5/1 Technical overview DILM, DILEM Moeller HPL011-007/008 DILM contactors 3 pole DIL EM M7 M9 M1 M15 M17 M5 M3 M40 M50 M65 M80 M95 M115 M150 M170 Basic device Page a 5/3 a 5/17 a 5/17 a 5/17 a 5/17 Complete devices Page a 5/1 a 5/1 a 5/1 a 5/1 Rated-operational voltage kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw AC-3 Rated operational power for three-phase motors 50 60 Hz 0 V 30 V,..5 3.5 4 5 7.5 10 1.5 15.5 0 5 30 37 48 5 380 V 400 V 4 3 4 5.5 7.5 7.5 11 15 18.5 30 37 45 55 75 90 440 V 4,6 4.5 5.5 7.5 8.4 10.5 15.5 0 5 3 41 51 60 75 95 105 500 V 4 3.5 4.5 7 7.5 1 17.5 3 8 36 47 58 70 85 110 10 660 V/690 V 4 3.5 4.5 6.5 7 11 17 3 30 35 75 90 96 0 1000 V 1) 1) 1) 1) 1) AC-4 i Increase in life span for DILM7 DILM150 to 00.000 operations Rated operational power for three-phase motors 50 60 Hz 0 V 30 V 1,5 1 1.5.5 3.5 4 5 6 7 1 16 17 0 0 380 V 400 V 3..5 3 3 4.5 6 7 9 10 1 0 6 8 33 33 440 V 3,3.4 3 3.6 3.6 5.5 7 8 10 1 5 3 35 41 41 500 V 3.5.8 3.5 3.5 6 8 9 11 13 16 9 36 40 47 47 660 V/690 V 3.9 3.6 4.4 4..5 8.5 10 1 17 6 35 43 48 48 1000 V 1) 1) 1) 1) 1) AC-1 Rated operational power for resistive load, 40 C 0 V 30 V 8 8 8 8 8 15 17 17 30 37 4 49 61 7 85 380 V 400 V 13 1 9 9 39 53 65 7 85 105 15 150 440 V 15 16 16 16 16 30 34 34 45 58 71 80 94 116 138 170 500 V 18 19 19 19 19 34 38 38 51 66 81 90 107 13 156 194 660 V/690 V 3 5 5 5 5 45 51 51 68 91 111 15 8 18 16 68 1000 V 1) 1) 1) 1) 1) Conventional thermal current I th = I e open at 40 C A A A A A A A A A A A A A A A A up to 690 V 40 45 45 60 80 98 110 130 160 190 5 1000 V 1) 1) 1) 1) 1) 1) on request Contactor 4 pole DIL EM4 MP0 Rated operational voltage Page a 5/3 a 5/17 AC-1 Conventional free air thermal current I th = I e open, at 40 C A A up to 690 V

DILM contactors 3 pole Moeller HPL011-007/008 Technical overview DILM, DILH 5/13 DIL M185 M5 M50 M300 M400 M500 M580 M650 M750 M80 M1000 M1600 H00 H000 Basic device Page Complete device Page a 5/5 a 5/5 a 5/5 a 5/5 a 5/5 Rated operational voltage kw kw kw kw kw kw kw kw kw kw kw kw kw kw AC-3 Rated operational power for AC motors 50 60 Hz 0 V 30 V 55 70 75 90 15 155 185 05 40 60 315 500 380 V 400 V 90 110 13 160 00 50 315 355 400 450 560 900 440 V 115 157 190 55 345 370 40 480 55 650 1000 500 V 13 160 180 15 90 360 40 470 550 600 730 1180 660 V 690 V 175 15 40 86 344 344 560 0 70 750 1000 1600 1000 V 108 108 108 13 13 13 600 600 800 800 1000 1) AC-4 Rated operational power for AC motors 50 60 Hz 0 V 30 V 41 51 6 75 9 11 3 161 181 09 60 430 380 V 400 V 75 90 110 13 160 00 50 80 315 355 450 750 440 V 85 10 15 0 186 9 90 36 367 418 50 830 500 V 96 116 3 17 10 330 370 417 474 590 940 660 V 690 V 17 155 189 9 83 344 440 494 556 3 780 1300 1000 V 108 108 108 13 13 13 509 509 678 678 1000 1) AC-1 Rated operational power for resistive load, 40 C 0 V 30 V 11 139 155 177 1 310 354 376 398 443 443 717 60 886 380 V 400 V 10 41 68 306 38 535 61 650 689 766 766 7 1071 1531 440 V 43 79 310 354 443 60 709 753 797 886 886 1371 0 1773 500 V 77 317 35 403 503 705 806 856 906 1007 1007 1558 10 015 660 V 690 V 365 419 465 53 6 930 10 1130 1196 1330 1330 151 1861 660 1000 V 5535 705 806 1007 10 161 171 1813 015 015 40 417 33 Conventional thermal current I th = I e open at 40 C A A A A A A A A A A A A A A at 690 V 337 386 49 490 61 857 980 1041 110 15 15 00 17 450 1000 V 337 386 49 490 61 857 980 1041 110 15 15 1700 69 1959 1) on request

5/ System overview DILM7 DILM170 Moeller HPL011-007/008 1 1 up to 90 kw (AC-3/400 V) 1 6 a Page 5/17 Suppressors a Page 5/4 Overload relays 3 a Page 6/6 3 Auxiliary contact modules 4 a Page 5/8 5 5 4 Auxiliary contact modules 5 a Page 5/11 Auxiliary contact modules 6 6 6 a Page 5/30 1 1 3 3 3 4 5 5

System overview 5/15 Moeller HPL011-007/008 DILM185 DILH000 1 5 4 3 90 900 kw (AC-3/400 V) Comfort range: 1 Mechanical interlock a Page 5/43 Terminal cover 4 a Page 5/47 a Page 5/5 Overload relays 3 Auxiliary contact modules 5 Standard range 90 50 kw 1 a Page 5/7 a Page 6/11 a Page 5/30

5/16 Ordering Basic units up to 170 A Ordering Basic units up to 170 A 5/17 DILM Moeller HPL011-007/008 Moeller HPL011-007/008 DILM AC operation DC operation Basic units Screw terminals Rated operational current Max. rating for three-phase motors, 50 60 Hz Conventional free air thermal current I th = I e AC-1 at 60 C Contacts AC-3 AC-3 AC-4 Open N/O = Normally open 380 V 400 V 0 V 30 V 380 V 400 V 660 V 690 V 0 V 30 V 380 V 400 V 660 V 690 V I e P P P P P P A A kw kw kw kw kw kw I th = I e N/C = Normally closed Contact sequence Can be combined with auxiliary contact 4 pole 1 3.5 5.5 6.5 3 4.4 0 A1 1 3 5 7 DILM3-XHI.. DILA-XHI(V).. 3 pole 7. 3 3.5 1..9 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. Part no. Article no. DILMP0(30V50HZ) 76970 DILM7-10(30V50HZ) 76550 7. 3 3.5 1..9 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM7-01(30V50HZ) 76585 9.5 4 4.5 1.5.5 3.6 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM9-10(30V50HZ) 76690 9.5 4 4.5 1.5.5 3.6 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM9-01(30V50HZ) 7675 1 3.5 5.5 6.5 3 4.4 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM1-10(30V50HZ) 76830 1 3.5 5.5 6.5 3 4.4 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM1-01(30V50HZ) 76865 15.5 4 7.5 7 3 4.4 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM15-10(30V50HZ) 90058 15.5 4 7.5 7 3 4.4 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM15-01(30V50HZ) 90093 8 see price list Part no. Article no. DILMP0(4VDC) 76985 DILM7-10(4VDC) 76565 DILM7-01(4VDC) 76600 DILM9-10(4VDC) 76705 DILM9-01(4VDC) 76740 DILM1-10(4VDC) 76845 DILM1-01(4VDC) 76880 DILM15-10(4VDC) 90073 DILM15-01(4VDC) 90108 see price list Std. pack 1 off 3 1 3 pole 18 5 7.5 11.5 4.5 6.5 35 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 18 5 7.5 11.5 4.5 6.5 35 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S 5 7.5 11 3.5 6 8.5 40 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 5 7.5 11 3.5 6 8.5 40 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S 3 10 15 17 4 7 10 40 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 3 10 15 17 4 7 10 40 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S DILM17-10(30V50HZ) 77004 DILM17-01(30V50HZ) 77036 DILM5-10(30V50HZ) 7713 DILM5-01(30V50HZ) 771 DILM3-10(30V50HZ) 7760 DILM3-01(30V50HZ) 779 DILM17-10(RDC4) 77018 DILM17-01(RDC4) 77050 DILM5-10(RDC4) 776 DILM5-01(RDC4) 77178 DILM3-10(RDC4) 7774 DILM3-01(RDC4) 77306 Accessories 1 Overload relay a 6/7 Suppressor a 5/4 3 Auxiliary contact module a 5/8 Further actuating voltages a 5/56 Accessories a 5/43 The DC operated contactors have integral suppressor circuits (DILM7 - DILM15: Varistor). DILM115, DILM150 and DILM170 have a built-in suppressor circuit. Mirror contact for DILM7-01 to DILM3-01 Contactor contact according to EN 5001 3 pole 40 1.5 18.5 3 5 9 1 50 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 50 15.5 30 6 10 15 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 65 0 30 35 7 1 17 80 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 7 5 37 35 7 1 17 80 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. DILM40(30V50HZ) 77766 DILM50(30V50HZ) 77830 DILM65(30V50HZ) 77894 DILM7(30V50HZ) 107670 DILM40(RDC4) 77780 DILM50(RDC4) 77844 DILM65(RDC4) 77908 DILM7(RDC4) 107671 3 pole 80 5 37 1 0 6 90 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 95 30 45 75 16 6 35 110 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 115 37 55 90 17 8 43 130 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 150 48 75 96 0 33 48 160 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 170 5 90 0 0 33 48 185 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. DILM80(30V50HZ) 3940 DILM95(30V50HZ) 39480 DILM115(RAC40) 39548 DILM150(RAC40) 39588 DILM170(RAC40) 107013 DILM80(RDC4) 39416 DILM95(RDC4) 39510 DILM115(RDC4) 39555 DILM150(RDC4) 39591 DILM170(RDC4) 107016

5/18 Ordering Basic units up to 170 A Ordering Basic units up to 170 A 5/19 DILM Moeller HPL011-007/008 Moeller HPL011-007/008 DILM AC operation DC operation Rated operational current Max. rating for three-phase motors, 50 60 Hz Conventional free air thermal current I th = I e AC-1 at 60 C Contacts AC-3 AC-3 AC-4 Open N/O = Normally open N/C = Normally closed 380 V 400 V 0 V 30 V 380 V 400 V 660 V 690 V 0 V 30 V 380 V 400 V 660 V 690 V I e P P P P P P A A kw kw kw kw kw kw I th = I e Contact sequence Can be combined with auxiliary contact Part no. Article no. see price list Part no. Article no. see price list Std. pack Basic units spring-loaded terminals 3 pole 7. 3 3.5 1..9 0 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC7-10(30V50HZ) 77389 7. 3 3.5 1..9 0 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC7-01(30V50HZ) 7741 9.5 4 4.5 1.5.5 3.6 0 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC9-10(30V50HZ) 77453 9.5 4 4.5 1.5.5 3.6 0 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC9-01(30V50HZ) 77485 1 3.5 5.5 6.5 3 4.4 0 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC1-10(30V50HZ) 77517 1 3.5 5.5 6.5 3 4.4 0 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC1-01(30V50HZ) 77549 DILMC7-10(4VDC) 77404 DILMC7-01(4VDC) 77436 DILMC9-10(4VDC) 77468 DILMC9-01(4VDC) 77500 DILMC1-10(4VDC) 7753 DILMC1-01(4VDC) 775 1 off 3 spring-loaded terminals on the auxiliary and control circuit terminals 3 pole 18 5 7.5 11.5 4.5 6.5 35 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC17-10(30V50HZ) 77581 18 5 7.5 11.5 4.5 6.5 35 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC17-01(30V50HZ) 77611 5 7.5 11 3.5 6 8.5 40 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC5-10(30V50HZ) 771 5 7.5 11 3.5 6 8.5 40 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC5-01(30V50HZ) 77671 3 10 15 17 4 7 10 40 1 N/O A1 1 3 5 13 DILM3-XHIC.. DILA-XHIC(V).. DILMC3-10(30V50HZ) 77701 3 10 15 17 4 7 10 40 1 N/C A1 1 3 5 1 DILA-XHIC(V).. DILMC3-01(30V50HZ) 77731 3 pole 40 1.5 18.5 3 5 9 1 50 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 50 15.5 30 6 10 15 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 65 0 30 35 7 1 17 80 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 3 pole 80 5 37 1 0 6 90 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 95 30 45 75 16 6 35 110 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 115 37 55 90 17 8 43 130 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. 150 48 75 96 0 33 48 160 A1 1 3 5 DILM150-XHIC(V).. DILM1000-XHIC.. DILMC40(30V50HZ) 77965 DILMC50(30V50HZ) 77995 DILMC65(30V50HZ) 7805 DILMC80(30V50HZ) 39618 DILMC95(30V50HZ) 39685 DILMC115(RAC40) 39736 DILMC150(RAC40) 39751 DILMC17-10(RDC4) 77595 DILMC17-01(RDC4) 7765 DILMC5-10(RDC4) 77655 DILMC5-01(RDC4) 77685 DILMC3-10(RDC4) 77715 DILMC3-01(RDC4) 77745 DILMC40(RDC4) 77979 DILMC50(RDC4) 78009 DILMC65(RDC4) 78039 DILMC80(RDC4) 3965 DILMC95(RDC4) 39715 DILMC115(RDC4) 39741 DILMC150(RDC4) 39765 Accessories 1 Overload relay a 6/7 Suppressor a 5/4 3 Auxiliary contact module a 5/8 Further actuating voltages a 5/56 Accessories a 5/43 1 The DC operated contactors have integral suppressor circuits (DILM7 - DILM15: Varistor). DILM115, DILM150 and DILM170 have a built-in suppressor circuit. Mirror contact for DILM7-01 to DILM3-01 Contactor contact according to EN 5001

5/0 Complete devices DILM Screw terminals Ordering Complete devices up to 170 A DLLM Rated operational current Max. rating for three-phase motors, 50 60 Hz AC-3 AC-3 AC-4 380 V 400 V 380 V 400 V 0 V 30 V 380 V 400 V 660 V 690 V 0 V 30 V 380 V 400 V 660 V 690 V I e P P P P P P I th = I e A kw kw kw kw kw kw A Moeller HPL011-007/008 Conventional free air thermal current I th = I e AC-1 at 60 C Open Moeller HPL011-007/008 Contacts Contact sequence AC operation DC operation N/O = Normally open N/C = Normally closed Part no. Article no. 7. 3 3.5 1..9 0 N/O 1 N/C A1 1 3 5 13 1 33 DILM7-1(30V50HZ) 7660 7. 3 3.5 1..9 0 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM7-3(30V50HZ) 76655 7. 3 3.5 1..9 0 N/O B A1 1 3 5 13 1 31 43 DILM7-(30V50HZ) 1060 9.5 4 4.5 1.5.5 3.6 0 N/O 1 N/C A1 1 3 5 13 1 33 DILM9-1(30V50HZ) 76760 9.5 4 4.5 1.5.5 3.6 0 N/O B A1 1 3 5 13 1 31 43 DILM9-(30V50HZ) 1061 9.5 4 4.5 1.5.5 3.6 0 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM9-3(30V50HZ) 76795 1 3.5 5.5 6.5 3 4.4 0 N/O 1 N/C A1 1 3 5 13 1 33 DILM1-1(30V50HZ) 76900 1 3.5 5.5 6.5 3 4.4 0 N/O B A1 1 3 5 13 1 31 43 DILM1-(30V50HZ) 106 1 3.5 5.5 6.5 3 4.4 0 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM1-3(30V50HZ) 76935 15.5 4 7.5 7 3 4.4 0 N/O B A1 1 3 5 13 1 31 43 DILM15-(30V50HZ) 10 18 5 7.5 11.5 4.5 6.5 35 N/O 1 N/C A1 1 3 5 13 1 33 DILM17-1(30V50HZ) 77068 18 5 7.5 11.5 4.5 6.5 35 N/O B A1 1 3 5 13 1 31 43 DILM17-(30V50HZ) 10 18 5 7.5 11.5 4.5 6.5 35 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM17-3(30V50HZ) 77100 5 7.5 11 3.5 6 8.5 40 N/O 1 N/C A1 1 3 5 13 1 33 DILM5-1(30V50HZ) 77196 5 7.5 11 3.5 6 8.5 40 N/O B A1 1 3 5 13 1 31 43 DILM5-(30V50HZ) 1065 5 7.5 11 3.5 6 8.5 40 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM5-3(30V50HZ) 778 3 10 15 17 4 7 10 40 N/O 1 N/C A1 1 3 5 13 1 33 DILM3-1(30V50HZ) 7734 3 10 15 17 4 7 10 40 N/O B A1 1 3 5 13 1 31 43 DILM3-(30V50HZ) 1066 3 10 15 17 4 7 10 40 3 N/O N/C A1 1 3 5 13 1 31 43 53 DILM3-3(30V50HZ) 77356 40 1.5 18.5 3 5 9 1 50 N/O N/C A1 1 3 5 13 1 31 43 DILM40-(30V50HZ) 77798 50 15.5 30 6 10 15 N/O N/C A1 1 3 5 13 1 31 43 DILM50-(30V50HZ) 7786 65 0 30 35 7 1 17 80 N/O N/C A1 1 3 5 13 1 31 43 DILM65-(30V50HZ) 7796 34 3 3 34 3 3 34 3 3 3 34 3 3 34 3 3 34 3 3 3 3 3 44 54 44 44 44 54 44 44 54 44 44 44 54 44 44 54 44 44 54 44 44 44 Part no. Article no. DILM7-1(4VDC) 765 DILM7-3(4VDC) 76670 DILM7-(4VDC) 1067 DILM9-1(4VDC) 76775 DILM9-(4VDC) 1068 DILM9-3(4VDC) 76810 DILM1-1(4VDC) 76915 DILM1-(4VDC) 1069 DILM1-3(4VDC) 76950 DILM15-(4VDC) 1070 DILM17-1(RDC4) 7708 DILM17-(RDC4) 1071 DILM17-3(RDC4) 771 DILM5-1(RDC4) 7710 DILM5-(RDC4) 107 DILM5-3(RDC4) 774 DILM3-1(RDC4) 77338 DILM3-(RDC4) 1073 DILM3-3(RDC4) 77370 DILM40-(RDC4) 7781 DILM50-(RDC4) 77876 DILM65-(RDC4) 77940 Ordering Complete devices up to 170 A Std. pack 1 off DILM Accessories 1 Overload relay a 6/7 Suppressor a 5/4 Accessories a 5/43 The DC operated contactors have integral suppressor circuits (DILM7 - DILM15: Varistor). DILM115, DILM150 and DILM170 have a built-in suppressor circuit. Mirror contact for DILM7 to DILM150 Contactor contact according to EN 5001 1 5/1 80 5 37 1 0 6 90 N/O N/C A1 1 3 5 13 1 31 43 DILM80-(30V50HZ) 39449 3 44 95 30 45 75 16 6 35 110 N/O N/C A1 1 3 5 13 1 31 43 DILM95-(30V50HZ) 3957 3 44 115 37 55 90 17 8 43 130 N/O N/C A1 1 3 5 13 1 31 43 DILM115-(RAC40) 39578 3 44 150 48 75 96 0 34 48 160 N/O N/C A1 1 3 5 13 1 31 43 DILM150-(RAC40) 39598 3 44 DILM80-(RDC4) 394 DILM95-(RDC4) 39541 DILM115-(RDC4) 39581 DILM150-(RDC4) 39601

5/ Ordering up to 150 A with electronic actuation Ordering up to 150 A with electronic actuation 5/3 DILMF Moeller HPL011-007/008 Moeller HPL011-007/008 DILMF Basic units Screw terminals Rated operational current Max. rating for three-phase motors, 50 60 Hz Conventional free air thermal current I th = I e AC-1 at 60 C Contacts AC-3 AC-3 AC-4 Open N/O = Normally open N/C = Normally closed 380 V 400 V 0 V 30 V 380 V 400 V 660 V 690 V 0 V 30 V 380 V 400 V 660 V 690 V I e P P P P P P A A kw kw kw kw kw kw I th = I e Contact sequence Can be combined with auxiliary contact 3 pole 7. 3 3.5 1..9 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. AC operation Std. pack Part no. Article no. DILMF8-10(RAC40) 104413 7. 3 3.5 1..9 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILMF8-01(RAC40) 104417 9.5 4 4.5 1.5.5 3.6 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILMF11-10(RAC40) 10441 9.5 4 4.5 1.5.5 3.6 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILMF11-01(RAC40) 10445 1 3.5 5.5 6.5 3 4.4 0 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILMF-10(RAC40) 10449 1 3.5 5.5 6.5 3 4.4 0 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILMF-01(RAC40) 104433 18 5 7.5 11.5 4.5 6.5 35 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 18 5 7.5 11.5 4.5 6.5 35 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S 5 7.5 11 3.5 6 8.5 40 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 5 7.5 11 3.5 6 8.5 40 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S 3 10 15 17 4 7 10 40 1 N/O A1 1 3 5 13 DILM3-XHI.. DILA-XHI(V).. DILM3-XHI11-S 3 10 15 17 4 7 10 40 1 N/C A1 1 3 5 1 DILA-XHI(V).. DILM3-XHI11-S 3 pole 40 1.5 18.5 3 5 9 1 50 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 50 15.5 30 6 10 15 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 65 0 30 35 7 1 17 80 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. DILMF17-10(RAC40) 104437 DILMF17-01(RAC40) 104441 DILMF5-10(RAC40) 104445 DILMF5-01(RAC40) 104449 DILMF3-10(RAC40) 104453 DILMF3-01(RAC40) 104457 DILMF40(RAC40) 104461 DILMF50(RAC40) 104465 DILMF65(RAC40) 104469 see 1 off 1 Accessories Page 1 Overload relay a 6/7 Auxiliary contact module a 5/8 Further actuating voltages a 5/58 Accessories a 5/43 suitable for semi-conductor industry accordinf to SEMI F47. humm-free, suitable for building services automation. Operating mechanism adjustable from 50 Hz to 400 Hz. 3 pole 80 5 37 1 0 6 90 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 95 30 45 75 16 6 35 110 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 115 37 55 90 17 8 43 130 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. 150 48 75 96 0 33 48 160 A1 1 3 5 DILM150-XHI(V).. DILM1000-XHI(V).. DILMF80(RAC40) 104473 DILMF95(RAC40) 104477 DILMF115(RAC40) 104481 DILMF150(RAC40) 104485 All contactors have a built-in suppressor circuit. Mirror contact for DILMF8-01 to DILMF3-01 Contactor contact according to EN 5001

1) 5/4 Ordering Comfort devices greater than 150 A Ordering Comfort devices greater than 150 A 5/5 DILM, DILH DILM, DILH Rated operational current Max. rating for three-phase motors, 50 60 Hz Conventional Contact sequence free air thermal current I th = I e AC-1 at 40 C Part no. Article no. see Std. pack Note concerning the product DILM contactors, comfort AC-3 AC-3 AC-4 Open 380 V 0 V 380 V 660 V 1000 V 0 V 380 V 660 V 1000 V 400 V 30 V 400 V 690 V 30 V 400 V 690 V I e P P P P P P P P I th = I e A kw kw kw kw kw kw kw kw A 185 55 90 175 108 41 75 17 108 75 A1 1 3 5 13 1 31 43 DILM185/(R50) 08193 5 70 110 15 108 51 90 155 108 315 3 44 DILM5/(R50) 08197 50 75 13 40 108 6 110 189 108 350 DILM50/(R50) 0801 1 off Classical DILM185 to DILM1000, DILH00 DILM1600, DILH000 A1/ are attached to power supply as normal (+) L1 ( ) N A10 a (+) L1 ( ) N A10 a A11 A1 A11 A1 300 90 160 86 13 75 13 9 13 400 DILM300/(R50) 0805 400 15 00 344 13 9 160 83 13 500 DILM400/(R50) 0809 500 155 50 344 13 11 00 344 13 700 DILM500/(R50) 0813 580 185 315 560 600 3 50 440 509 800 DILM580/(R50) 0816 650 05 355 0 600 161 80 494 509 850 DILM650/(R50) 0819 750 40 400 70 800 181 315 556 678 900 DILM750/(R50) 08 80 60 450 750 800 09 355 3 678 1000 DILM80/(R50) 085 1000 315 560 1000 1100 60 450 780 1000 1000 DILM1000/(R50) 67 1600 500 900 1600 1) 430 750 1300 1) 1800 A1 1 3 5 13 1 31 43 DILM1600/ (RAW50) 3 44 10677 Direct from the PLC A 4 V output from the PLC can be directly connected to the connections A3/A4. (+) L1 ( ) N 4 V GND From a low-power actuating device Low-power actuating devices such as PCB relays, actuating devices or position switches can be directly connected to A10/A11. A10 A11 b A3 A4 A1 A3 A4 (+) L1 ( ) N A10 A11 A1 a a (+) L1 ( ) N 4 V GND TY TX A10 A11 TY TX b A3 A4 A1 A3 A4 (+) L1 ( ) N A10 A11 A1 a a A3 TY A3 A4 TX A4 DILM contactors, comfort 00 A1 1 3 5 13 1 31 43 DILH00/(RAW50) 7441 000 3 44 DILH000/(RAW50) 744 1 off a Stopping in case of emergency (Emergency-stop) b max. capacity 6 nf All contactors can be combined with auxiliary contact module DILM 1000-XHI... Note concerning the product 660 V, 690 V or 1000 V: not directly reversing All contactors have a built-in suppressor circuit. When operating contactors DILM580 to DIL1600 with frequency inverter, the suppressor circuit on the load side must be removed. During a high voltage test for the contactors DILM580 to DILH000 the suppressor circuit on the load side must be removed. Control voltages R50 q 110 V 50 V AC/DC RAW50 q 30 V 50 V AC/DC Accessories Auxiliary contact modules a 5/30 Enclosures Further actuating voltages a 5/59

1) 5/6 Ordering Standard devices greater than 150 A Ordering Standard devices greater than 150 A 5/7 DILM Moeller HPL011-007/008 Moeller HPL011-007/008 DILM Complete devices DILM Complete devices DILM Rated operational current Max. rating for three-phase motors, 50 60 Hz AC-3 AC-3 AC-4 Open 380 V 400 V 0 V 380 V 660 V 1000 V 0 V 380 V 660 V 1000 V I th = I e 30 V 400 V 690 V 30 V 400 V 690 V I e P P P P P P P P A kw kw kw kw kw kw kw kw A Conventional free air thermal current I th = I e AC-1 at 55 C Contact sequence Can be combined with auxiliary contact Part no. Article no. 185 55 90 175 108 41 75 17 108 337 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM185-S/(0-40V50/60HZ) 74185 5 70 110 15 108 51 90 155 108 386 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM5-S/(0-40V50/60HZ) 74187 50 75 13 40 108 6 110 189 108 49 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM50-S/(0-40V50/60HZ) 74190 3 3 3 44 44 44 see Std. pack 1 off DILM...-S contactors are triggered in the conventional manner (+) L1 ( ) N A1 a 300 90 160 86 13 75 13 9 13 490 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM300-S/(0-40V50/60HZ) 74193 3 44 400 15 00 344 13 9 160 83 13 61 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM400-S/(0-40V50/60HZ) 74196 3 44 500 155 50 344 13 11 00 344 13 857 A1 1 3 5 13 1 31 43 DILM1000-XHI... DILM500-S/(0-40V50/60HZ) 74199 3 44 a Standstill in an emergency (Emergency-Stop) 660/690 V or 1000 V: not directly reversing All contactors have a built-in suppressor circuit. Accessories Auxiliary contact modules a 5/30 Enclosure Further actuating voltages a 5/59

5/8 Ordering Auxiliary contact modules DILM, DILA Moeller HPL011-007/008 Connection technique Conventional thermal current I th = I e AC-1 at 50 C Contacts Contact sequence Can be combined with basic unit Part no. Article no. see price list Std. pack Open I th = I e A N/O = Normally open, N/O E = Normally open (early make contact) N/C = Normally closed N/C L = Normally closed (late break contact) Auxiliary contact modules With positively driven contacts; except XHIV and XHICV Top mounting auxiliary contacts Screw terminals pole 16 1 N/O 1 N/C 1 33 DILM(C)7-10... DILM(C)9-10... DILM3-XHI11 77376 pole N/C 34 DILM(C)1-10... 1 31 DILM(C)15-10... DILM3-XHI0 DILM(C)17-10... 77375 4 pole N/O N/C 3 1 31 43 53 DILM(C)5-10... DILM(C)3-10... DILM3-XHI 77377 3 44 54 5 off 3 M 1 N/C 1 33 43 53 DILM3-XHI31 10611 34 44 54 springloaded terminals Screw terminals springloaded terminals pole 16 1 N/O 1 N/C 1 33 DILM3-XHIC11 77751 pole N/C 1 31 DILM3-XHIC0 77750 4 pole N/O N/C 1 31 43 53 DILM3-XHIC 7775 pole 16 N/O 53 DILM(C)7... DILM(C)9... DILA-XHI0 7 1 N/O 1 N/C 54 DILM(C)1... 53 61 DILM(C)15... DILA-XHI11 DILM(C)17... 71 6 N/C 54 51 61 DILM(C)5... DILM(C)3... DILA-XHI0 70 1 N/O E 1 N/C L 57 65 DILA-XHIV11 73 4 pole 16 4 N/O 53 73 83 DILA-XHI40 78 3 N/O 1 N/C 53 61 73 83 DILA-XHI31 77 N/O N/C 53 61 71 83 DILA-XHI 76 1 N/O 3 N/C 53 61 71 81 DILA-XHI13 75 4 N/C 51 61 71 81 DILA-XHI04 74 1 N/O, 1 N/C, 57 65 71 83 DILA-XHIV 1 N/O E 1 N/C L 79 pole 16 N/O 53 DILA-XHIC0 7658 5 54 3 3 6 58 54 54 54 54 5 58 34 66 44 74 6 6 6 6 66 54 74 7 7 84 84 8 7 8 7 84 84 1 N/O 1 N/C 53 61 DILA-XHIC11 7657 54 6 N/C 51 61 DILA-XHIC0 7656 5 6 1 N/O E 1 N/C L 57 65 DILA-XHICV11 7659 58 66 Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L, within the auxiliary contact modules (not N/O (early make) and N/C (late break) contacts) and for the built-in auxiliary contacts of the DILM7 DILM3 Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not N/C (late break) contact)

Ordering Auxiliary contact modules 5/9 Moeller HPL011-007/008 DILM, DILA Connection technique Conventional thermal current I th = I e AC-1 at 50 C Contacts Contact sequence Can be combined with basic unit Part no. Article no. see price list Std. pack Open I th = I e A N/O = Normally open, N/O E = Normally open (early make contact) N/C = Normally closed N/C L = Normally closed (late break contact) Auxiliary contact modules With positively driven contacts; except XHIV and XHICV Top mounting auxiliary contacts springloaded 4 pole 16 4 N/O 53 73 83 DILM(C)7... DILM(C)9... DILA-XHIC40 76534 54 74 84 terminals DILM(C)1... 3 N/O 1 N/C 53 61 73 83 DILM(C)15... DILM(C)17... DILA-XHIC31 76533 N/O N/C 5 74 53 61 71 84 83 DILM(C)5... DILM(C)3... DILA-XHIC 7653 1 N/O 3 N/C 53 61 71 81 DILA-XHIC13 76531 1 N/O, 1 1 N/C, 1 N/O E N/C L 54 54 6 6 7 7 8 84 4 N/C 51 61 71 81 DILA-XHIC04 76530 5 58 6 57 65 66 7 8 71 7 83 84 DILA-XHICV 76535 5 off High version 1) Screw terminals pole 16 N/O 53 DILM7... DILM9... DILA-XHIT0 10104 1 N/O 1 N/C 54 DILM1... 53 61 DILM15... DILA-XHIT11 101043 N/C 51 61 DILA-XHIT0 101041 4 pole N/O N/C 53 61 71 83 DILA-XHIT 101044 5 54 6 54 6 6 7 84 5 off Side mounting auxiliary contacts ) Screw pole 10 1 N/O 1 N/C 53 61 DILM17... terminals DILM5... 5 DILM3... DILM3-XHI11-S 101371 1 off 1) Suitable for combination with electrical wire jumpers in tool-less plug connection; for use with: DILM1-XSL DILM1-XRL DILM1-XS1 1 PKZM0-XDM1 PKZM0-XRM1 PKZM0-XSM1 4 1 PKZM0 DILM7 DILM15 3 DILA-XHIT 4 PKZM0-XDM1 3 ) Can be fitted only to the left of the contactor; can not be combined with top-mounting auxiliary contacts or mechanical interlocks Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L, within the auxiliary contact modules (not N/O (early make) and N/C (late break) contacts) and for the built-in auxiliary contacts of the DILM7 DILM3 Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not N/C (late break) contact) No auxiliary contacts can be fitted between contactors.

5/30 Ordering Auxiliary contact modules DILM Moeller HPL011-007/008 Connection technique Conventional thermal current I th = I e AC-1 Open I th = I e A Contacts N/O = Normally open, N/O E = Normally open (early make contact) N/C = Normally closed N/C L = Normally closed (late break contact) Contact sequence Can be combined with basic unit Part no. Article no. Auxiliary contact modules With positively driven contacts; except XHIV and XHICV 13 3 Screw pole 16 N/O DILM40... DILM150-XHI0 terminals DILM50... 77945 16 1 N/O 1 N/C 4 DILM65... 13 1 DILM7 DILM150-XHI11 DILM7... 77946 16 1 N/O 1 N/C DILM80... 53 61 DILM95... DILM150-XHIA11 DILM115... 834 5 16 N/C DILM170 11 1 DILM150-XHI0 77947 1 see price list Std. pack 5 off Screw terminals 4 pole 16 4 N/O 13 3 33 43 DILM150-XHI40 77948 16 3 N/O 1 N/C 13 1 33 43 DILM150-XHI31 77949 16 N/O N/C 13 1 31 43 DILM150-XHI 77950 16 N/O N/C 53 61 71 83 DILM150-XHI 834 16 1 N/O 3 N/C 13 1 31 41 DILM150-XHI13 77951 16 4 N/C 11 1 31 41 DILM150-XHI04 7795 16 1 N/O, 1 N/O E 1 N/C, 1 N/C L 1 54 4 6 13 1 34 3 3 3 34 7 35 36 4 4 44 44 44 84 47 48 DILM150-XHIV 77953 Side mounting auxiliary contacts Screw terminals pole 10 1 N/O 1 N/C 13 1 DILM40 DILH000 10 1 N/O E 1 N/C L 17 5 DILM40 DILH000 10 1 N/O 1 N/C 53 61 DILM80 DILH000 18 44 43 48 47 84 6 5 3 31 36 35 7 71 83 DILM1000-XHI11-SI 7845 DILM1000-XHIV11-SI 7846 DILM1000-XHI11-SA 7847 1 off

Engineering Auxiliary contact modules 5/31 Moeller HPL011-007/008 DIL DILM40... DILM7 DILM80( )... DILM170 DILM185... DILM1600 DILM1000-XHI(V)11-SI DILM1000-XHI(V)11-SA DILM150-XHI0 DILM150-XHI11 DILM150-XHI0 DILM150-XHI40 DILM150-XHI31 DILM150-XHI(V) DILM150-XHI13 DILM150-XHI04 DILM150-XHIA11 x 1 x x 1 x 1 x 1 x 1 x 1 x x x x 1 x x 1 x x 1 x x 1 x x x DILM150-XHI DILH00... DILH000 x x Side mounting auxiliary contacts DILM1000-XHI(C).. + a + DILM1000-XHI(C)..-SI + + b + + DILM1000-XHI(C)..-SA a DILM40 DILM7 b DILM80 DILH000 Positive action contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact module (not N/O early close and N/C late open) Auxiliary contacts can be used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open) No auxiliary contact is possible between two contactors with mechanical interlock. auxiliary contacts DILM1000-XHI11-SI are already built into the contactors DILM185/ to DILH000/.

5/3 Ordering for capacitors DILK Moeller HPL011-007/008 DILK contactors for capacitors Three-phase capacitors 50 60 Hz Contact sequence Part no. Article no. Open 30 V 50 Hz 55 V 690 V kvar kvar kvar kvar With series resistors without quick-discharge resistor Basic units 7.5 1.5 16.7 0 DILK1-11(30V50HZ) 93988 A1 1 3 5 13 1 11 0 5 33.3 DILK0-11(30V50HZ) 94010 15 5 33.3 40 DILK5-11(30V50HZ) 9403 see price list Std. pack 1 off 0 33.3 40 55 DILK33-10(30V50HZ) 94054 A1 1 3 5 13 5 50 65 85 DILK50-10(30V50HZ) 94076 Weld-resistant for capacitors with inrush current peaks up to 180 x I N L1 L L3 A1 1 3 5 R11 C1 R11 R11 Accessories Enclosure Accessories a 5/58 Further actuating voltages a 5/58 In the case of group compensation multi-stage capacitor banks are connected to the mains, as required. In the process, transient currents of up to 180 x I e can flow between the capacitors. The capacitors are pre-charged via the early-make auxiliary contacts and the fitted wire resistors, thereby reducing the inrush current. The main contacts then close after a time lag and carry the uninterrupted current. The contactors for capacitors are weld-resistant with inrush current peaks up to 180 x I e. due to their special contacts. For the switching of choked compensation systems please see engineering notes a Engineering, Power factor Correction

Moeller HPL011-007/008 Engineering for power factor correction DILM, DILK 5/33 Ordering data Switching duty 30 V 400 V 55 V 690 V 40 V 440 V Part no. Page kvar kvar kvar kvar Individual compensation, open version DILM7 a 5/17 1,5 3 3,5 5 DILM9 a 5/17 4 4,5 6 DILM1 a 5/17,5 4,5 5,5 7 DILM15 a 5/17,5 4,5 5,5 7 DILM17 a 5/17 6,5 1,5 19 DILM5 a 5/17 7 13,5 16 1 DILM3 a 5/17 7,5,5 17,5 DILM40 a 5/17 11 0,5 4,5 3 DILM50 a 5/17 11,5 6 34,5 DILM65 a 5/17 1,5 3,5 8 37 DILM80( ) a 5/17 16 30,5 36,5 48 DILM95 a 5/17 18 34 41 54 DILM115 a 5/17 4 46 54,5 7 DILM150 a 5/17 8 53,5 83,5 DILM185 a 5/5 87 150 190 150 DILM300 a 5/5 115 00 65 00 DILM580 a 5/5 175 300 400 300 Group compensation, with choke, open version DILM7 a 5/17 4 7 7,5 1 DILM9 a 5/17 5 8 10 DILM1 a 5/17 5,5 10 1 16 DILM15 a 5/17 5,5 10 1 16 DILM17 a 5/17 7,5 18 0 8 DILM5 a 5/17 10 0 3 30 DILM3 a 5/17 1.5 5 5 3 DILM40 a 5/17 15 30 30 40 DILM50 a 5/17 0 40 40 48 DILM65 a 5/17 5 50 50 57 DILM80( ) a 5/17 30 60 70 90 DILM95 a 5/17 35 70 80 104 DILM115 a 5/17 50 95 100 15 DILM150 a 5/17 55 115 115 15 DILM185 a 5/5 80 150 00 60 DILM5 a 5/5 100 175 30 300 DILM50 a 5/5 110 190 60 340 DILM300 a 5/5 130 5 90 390 DILM400 a 5/5 160 80 370 480 DILM500 a 5/5 0 390 500 680 Group compensation, without choke, open version DILK1 a 5/3 7.5 1.5 16.7 0 DILK0 a 5/3 11 0 5 33.3 DILK5 a 5/3 15 5 33.3 40 DILK33 a 5/3 0 33.3 40 55 DILK50 a 5/3 5 50 65 85 DILM185 a 5/5 66 115 5 115 DILM300 a 5/5 85 150 195 150 DILM580 a 5/5 5 50 333 50 Use of the contactor DILM without series resistance for group compensation When using the contactors for group compensation in a system without chokes each capacitor must have a minimum induction of approx. 6 mh to limit the switch-on peaks. This means coil of cable with 5 turns and a diameter of approx. 0 mm. The conductor cross section must correspond to the rated phase current.

5/34 Ordering Lighting contactors DILL... Moeller HPL011-007/008 Lighting contactors DILL Rated operational current Conventional free air thermal current th = e AC-1 at 60 C AC-5a operation AC-5b operation Open 30 V 400 V 30 V 400 V I th = I e I e I e I e I e A A A A A Contact sequence Part no. Article no. Lighting contactors DILL 1 1 4 A1 1 3 5 DILL1(30V50HZ) 10440 1 1 4 A1 1 3 5 DILL1(4V50HZ) 104401 1 1 4 A1 1 3 5 DILL1(400V50HZ) 104403 18 18 1 1 35 A1 1 3 5 DILL18(30V50HZ) 104405 18 18 1 1 35 A1 1 3 5 DILL18(4V50HZ) 104404 18 18 1 1 35 A1 1 3 5 DILL18(400V50HZ) 104406 0 0 7 7 40 A1 1 3 5 DILL0(30V50HZ) 104408 0 0 7 7 40 A1 1 3 5 DILL0(4V50HZ) 104407 0 0 7 7 40 A1 1 3 5 DILL0(400V50HZ) 104409 see price list Std. pack 1 off

Engineering Switchgear for lighting systems 5/35 Moeller HPL011-007/008 DIL L1 L18 L0 M7 M9 M1 M17 M5 M3 M40 M50 Permissible compensation capacitance C max [mf] 470 470 470 47 80 100 0 330 470 470 500 Filament bulbs I e [A] 1 7 6 7.5 10 1 7 33 4 Mercury blended lamps I e [A] 1 16 3 5 6.5 8.5 1 16 3 30 38 Fluorscent lamps, conventional choke I e [A] 0 6 35 9 10 15 0 6 35 41 45 starter circuit Fluorescent lamps, duo circuit (series I e [A] 0 6 35 5.5 8 13 15.5 9 36 47 compensated) Electronic upstream devices I e [A] 1 18 0 5 6.5 8.5 1 17.5.5 8 35 High-pressure lamps I e [A] 1 18 0 3.5 6 10 1 17.5 0 5 30 Metal-halide lamps I e [A] 1 18 0 3.5 6 10 1 17.5 0 5 30 High-pressure sodium lamps I e [A] 1 18 0 3.5 6 10 1 17.5 0 5 30 Low-pressure sodium lamps I e [A] 7.5 10 1 3 7.5 10 1 15 Lighting contactors DILL DIL M65 M80 M95 M115 M150 M185 M5 M50 M300 M400 M500 Permissible compensation capacitance C max [mf] 500 550 60 830 970 055 300 600 3000 350 3500 Filament bulbs I e [A] 55 67 79 95 15 153 187 08 49 33 415 Mercury blended lamps I e [A] 45 65 67 80 110 13 150 167 00 66 33 Fluorscent lamps, conventional choke I e [A] 55 95 100 15 5 07 37 300 375 55 starter circuit Fluorescent lamps, duo circuit (series I e [A] 59 71 95 100 138 186 13 36 70 338 473 compensated) Electronic upstream devices I e [A] 45.5 56 66.5 80.5 105 130 158 175 10 80 350 High-pressure mercury vapour lamps I e [A] 36 55 60 80 95 138 158 175 00 50 350 Metal-halide lamps I e [A] 36 55 60 80 95 138 158 175 00 50 350 High-pressure sodium lamps I e [A] 36 55 60 80 95 138 158 175 00 50 350 Low-pressure sodium lamps I e [A] 5 35 40 50 70 100 111 13 0 175 45 With compensated lamps the total of the capacities must not exceed the max.permissible capacitor load (C max ) of the contactor.

5/36 Ordering Star-delta starter combinations Ordering Star-delta starter combinations 5/37 SDAINL Moeller HPL011-007/008 Moeller HPL011-007/008 SDAINL Contactor combinations Star-delta combinations Operating frequency max. 30 starts/hour AC operation Rated operational current Max. rating for three-phase motors, 50 60 Hz Max. changeover time Part no. Article no. see price list AC-3 AC-3 Mains contactor Q11 380 V 400 V 380 V 400 V 0 V 30 V 380 V 400 V 500 V 660 V 690 V Std. pack Individual components of the combination Spare auxiliary contacts Delta contactor Q15 Star contactor Q13 I e P P P P Part no. Part no. Part no. Part no. A kw kw kw kw s 1 4 5.5 5.5 30 SDAINLEM(30V50HZ) 051840 1 off DILEM-10 + DILEM DILEM-01 DILEM-10 + 0DILEM Timing relay K1 Q11 Q13 Q15 DILET 1 31 53 3 54 Contactor combinations 1 3 5.5 5.5 5.5 0 SDAINLM1(30V50HZ) 7886 DILM7-10 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 ETR4-51 1 3 5.5 5.5 5.5 0 SDAINLM1(4VDC) 100416 16 4 7.5 7.5 7.5 0 SDAINLM16(30V50HZ) 78311 16 4 7.5 7.5 7.5 0 SDAINLM16(4VDC) 100417 5.5 11 11 11 0 SDAINLM(30V50HZ) 78336 5.5 11 11 11 0 SDAINLM(4VDC) 100418 30 7.5 15 18.5 18.5 0 SDAINLM30(30V50HZ) 78361 30 7.5 15 18.5 18.5 0 SDAINLM30(RDC4) 100419 45 11 30 0 SDAINLM45(30V50HZ) 78386 DILM7-10 + DILA-XHI0 DILM9-10 + DILA-XHI0 DILM9-10 + DILA-XHI0 DILM1-10 + DILA-XHI0 DILM1-10 + DILA-XHI0 DILM17-10 + DILA-XHI0 DILM17-10 + DILA-XHI0 DILM5-10 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM9-01 + DILA-XHI0 DILM9-01 + DILA-XHI0 DILM1-01 + DILA-XHI0 DILM1-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 DILM5-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM7-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 1 Accessories 1 Overload relay a 6/7 Accessories a 5/4 Main circuit: Depending on the coordination type required (i.e. Type 1 or Type ) it must be established whether the fuse protection and the input wiring for the mains contactor and delta contactor are to be common or separate. 45 11 30 0 SDAINLM45(RDC4) 10040 55 15 30 37 30 0 SDAINLM55(30V50HZ) 78411 DILM5-10 + DILA-XHI0 DILM3-10 + DILA-XHI0 DILM5-01 + DILA-XHI0 DILM3-01 + DILA-XHI0 DILM17-01 + DILA-XHI0 DILM5-01 + DILA-XHI0 Circuit diagram a Engineering 55 15 30 37 30 0 SDAINLM55(RDC4) 10041 DILM3-10 + DILA-XHI0 DILM3-01 + DILA-XHI0 DILM5-01 + DILA-XHI0

5/38 Engineering Star-delta combinations SDAINL Moeller HPL011-007/008 Circuit diagrams, Star-delta combinations SDAINLEM L1 L L3 Contactor combinations Q11 1 3 5 F1 Q15 A C 0.58 x I n 0.58 x I n B 1 x I n 1 3 5 Q13 1 3 5 I 0 13 1 Q11 Q11 13 44 Q13 43 13 Q15 K1 1 15 16 18 Q13 1 U1 V1 W1 M1 3~ M V W U K1 N A1 Q11 N A1 Q13 Y A1 Q15 A1 SDAINLM1 SDAINLM55 L1 L L3 F1 B 1 x I n 0 S11 I 1 13 Q11 13 Q11 1 3 5 Q15 A C 0.58 x I n 0.58 x I n U1 V1 W1 M1 3~ M 1 3 5 V W U Q13 1 3 5 54 Q11 53 Q13 A1 Q11 ( )N N 54 53 54 53 Q15 K1 A1 K1 Q15 Q13 Y 17 18 1 A1 K1 Q13 Q15 17 8 1 A1 SDAINLM70 SDAINLM60 L1 L L3 F1 B 1 x I n 0 S11 I 1 13 Q11 13 Q11 1 3 5 Q15 A C 0.58 x I n 0.58 x I n U1 V1 W1 M1 3~ M 1 3 5 V W U Q13 1 3 5 44 Q11 43 Q13 A1 Q11 ( )N N 13 13 Q15 K1 A1 K1 Q15 Q13 Y 17 18 1 A1 K1 Q13 Q15 17 8 1 A1 Overload relay settings Starting A: I N x 0.58 F 15 s Motor protected in Y and d- positions B: I N x 1 15 40 s Only partial motor protection in Y position C: I N x 0.58 > 40 s Motor not protected in Y position Timing relay set to approx. 10 s Main circuit: Depending on the coordination type required (i.e. Type 1 or Type ) it must be established whether the fuse protection and the input wiring for the mains contactor and delta contactor are to be common or separate.