USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Similar documents
USER MANUAL MPS 1-5KW SERIES

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

1. Important Safety Warning

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Solar Hybrid Inverter SP Brilliant Series

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Uninterruptible Power System

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation and Operation Back-UPS BX550CI-CN

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

General Precautions. Personnel Precautions

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual. 3kW Hybrid PV Inverter HX-3000

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

User Manual. Solar Charge Controller 3KW

Solar Hybrid Inverter SP Efecto Series

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual. Hybrid PV Inverter. Version: 2.1

Pure sine wave charger inverter Product Manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

User Manual Solar Charge Controller 3KW

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Solar Hybrid Inverter SP Efecto Series

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

R series solar charger inverter 1000W to 6000W

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

SOLARINVERTER MPPT 4KVA - 5KVA

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

according to VDE AR-E Manual V 3.1

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

SAFETY INSTRUCTIONS INTRODUCTION

CP900EPFCLCD User s Manual K

User Manual 1.5KVA 3KVA 1.0PF INVERTER / CHARGER

User Manual. EGL - 6K/10K Online UPS. Uninterruptible Power Supply System

Solar Hybrid Inverter SP Initial Series

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

SOLAR INVERTER/CHARGER

Solar Inverter Manual

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

User Manual. PF0.9 6K/10K Online UPS

User Manual / Manuel utilisateur

User Manual G1 Solar MPPT Inverter Solar MPPT Charger English version..1

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual. The power behind competitiveness

USER MANUAL. Uninterruptible power supply MODEL: 53965,

PR1000ELCD / PR1500ELCD User s Manual

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 3KW 120VAC. Appliances. Airconditioning Fridge. Washing machine

User Manual. 6K/10K Online UPS with Isolation Transformer. Uninterruptible Power Supply System

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

OHY3P kW Hybrid Inverter (3-Phase) USER MANUAL V2.0

User Manual Rittal PMC UPS 6kVA

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 3KW-5KW. Appliances. Airconditioning Fridge. Washing machine

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

GSM Series MPPT PV Controller. Version 1.0. Manual

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

CPS Energy Balancer. Version: 1.0

Uninterruptible Power System

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

HYBRID SOLAR INVERTER

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Transcription:

USER MANUAL IPS home inverters with UPS function Suitable for UPS: - IPS300-SIN - IPS300-SIN-WM - IPS300-SIN-DC - IPS600-SIN - IPS600-SIN-WM - IPS600-SIN-DC - IPS1000-SIN - IPS1000-SIN-DC - IPS1600-SIN - IPS1600-SIN-DC - IPS2500-SIN - IPS3500-SIN 1

Table of Contents 1 Safety Information... 1 2 Product Overview... 4 2.1 Specifications... 4 2.2 Front panel features... 6 2.3 Rear panel features... 6 3 Installation Instructions... 8 3.1 Unpacking Inspection..... 8 3.2 Installation... 8 4 Operations... 10 4.1 Turn the inverter On/Off... 10 4.2 Display interface... 10 4.3 Settings... 10 4.4 Troubleshooting... 13 2

Models quick description IPS300-SIN IPS600-SIN IPS1000-SIN IPS1600-SIN IPS2500-SIN IPS3500-SIN Standalone metal case IPS300-SIN-DC IPS600-SIN-DC IPS1000-SIN-DC IPS1600-SIN-DC IPS300-SIN-WM IPS600-SIN-WM Standalone metal case with DC output and PV input Wall mounted metal case 1 Safety Information CAUTION Non-qualified electricians are forbidden to open the case due to hazard of electrical shock. Consulting the dealer is required before using for below equipment. Its application, configuration, management and maintenance must be specially considered and designed. Medical equipment which is directly related to patients life Elevator and other equipment which may endanger personal safety Safety and General Information Read all safety information and operating instructions carefully before attempting to install, operate, service or maintain the inverter. Do not disassemble this inverter. Contact your local service center if maintenance or repair is needed. Disconnect all connection wiring before maintenance or cleaning to avoid the risk of electric shock. Do not use liquid extinguisher if there is a fire, a dry powder extinguisher is recommended. Do not dispose of the batteries with fire. The batteries may explode. Do not open or mutilate batteries. Released electrolyte inside is harmful to the skin and eyes, and maybe toxic. Do not connect the positive pole and negative pole directly, otherwise it will cause electric shocks or will be on fire. 3

2 Product Overview 2.1 Specifications MODEL 300W 600W 1000W 1600W 2500W 3500W DC Input (the inverter must be connected to batteries to work properly) Nominal input voltage 12V 24V DC input range 10 ~ 15V 20 ~ 30V AC Input Bypass input range 0 ~ 264Vac for 220Vac/230Vac/240Vac, Mains input range 150 ~ 282Vac for 220Vac; 156 ~ 294Vac for 230Vac; 163 ~ 307Vac for 240Vac; Input frequency range 50Hz / 60Hz (Auto-sense& Settable:5% ~15%,default 15%), 42.5 ~ 57.5Hz for 50Hz, 51 ~ 69Hz for 60Hz 99 ~ 282Vac for 220Vac; 104 ~ 294Vac for 230Vac; Input range of the 108 ~ 307Vac for 240Vac; generator No AVR in generator mode Input frequency range of the generator 40 ~ 70Hz Input power matching of the generator Rated power 10% ~ 150%, regulating step 10%,default 120% Output Inverter output range 220Vac / 230Vac / 240Vac ± 5% or Bypass output range 0 ~ 264Vac for 220V/230V/240V, Mains output range 174 ~ 242Vac for 220Vac; 182 ~ 253Vac for 230Vac; 190 ~ 264Vac for 240Vac; Output frequency 50Hz / 60Hz ± 0.3 (Auto-sense & settable) Output waveform Pure sine wave Output power 300W 600W 1000W 1600W 2500W 3500W Putput sockets 2x schuko CEE 7/3 Block terminal Efficiency Max. 95% (Mains mode); Max. 80% (Inverter mode) ECO mode Settable, load<3%,enter in 80 s No-load shutdown Settable, time can be set (1 ~ 99 min), load can be set (3% ~ 50%) Transfer time 10 ms 15 ms Power factor 1.0 THDV < 5% (linear load) Inductive load Yes Motor load Yes Rectifier load Yes Overload capability Mains mode: 110% 120 s; 125% 60 s; 150% 10 s (switch to bypass) Inverter mode: 110% 60s; 125% 10 s; 150% 10s (shut down) Battery String battery q-ty 1 1 1 2 2 2 Default Charging current Default 20A, regulating step 1A (< 10A) / 5A (> 10A) 10A (selectable) Max. 15A Max. 30A Max. 40A Max. 40A Max. 50A Max. 60A Equalizing charge voltage Single battery 14.4Vdc (default), 13.6 ~ 15Vdc settable Floating charge voltage Single battery 13.7Vdc (default), 13.2 ~ 14.6Vdc settable DOD Single battery 10.8Vdc (default), 9.6 ~ 13Vdc settable EOD Single battery 10.2Vdc (default), 9.6 ~ 11.5Vdc settable Reverse warning Buzzer Alarm Switch on / off Continuous beep 2 s Low battery Beep 0.2 s at interval of 0.4 s Overload Beep 2 s at interval of 2.5 s Mains power abnormal Beep 0.3 s at interval of 5 s MPPT Modules (for DC series only) Model 40A / / 4

Max. PV input voltage(voc) 40 V 60 V / / PV optimum operating voltage(vmp) 18 V ~ 32 V 29V ~ 48 V / / Max.PV. power 120W / 240W / 240W / 480W / 360W / 480W 720W / 960W / DC Outputs (for DC series only) Model 5V (2A), 9V / 12V (1A), 15V / 24V (1A), 2pin socket: 12V (10A) Other 1x PoE, 2x USB 5B (2A) Others Overload short-circuit overvoltage undervoltage overcharge Protections overtemperature excessive low battery missing insert Interface LCD & BUZZER Operating 0 ~ 40 temperature Operating humidity Relative humidity 93% < 1000m, (above 1000m, derating 1% for each additional 100 m), Altitude 4000 m max. Net weight (kg) 8.0/8.5/7.4 10.9/11.4/11 14.0/14.6 18.0/18.5 32.0 36.0 Gross weight (kg) 9.0/9.5/8.4 11.9/12.4/12 15.0/15.6 19.0/19.5 34.0 38.0 280 258 120 (w/o option) Dimensions (W D H) 293 280 160 (w/ option) 293 280 160 302 479 209 mm 400 210 127 (Wall mounted) Packaged dimensions (W D H) mm 330 352 200 (w/o option) 370 355 235 (w/ option) 490 290 195 (Wall mounted) 370 355 235 353 582 287 Note: Specifications are subject to change without notice;mppt modules and DC modules are optional. Charging features Charging process Three-stage: CC (constant current) CV (constant voltage) Float (floating charge) Process diagram Constant voltage charging time: 60 S 5

2.2 Front panel features 300W ~ 1600W front panel 300W ~ 600W front panel Tower type Wall mounted type 2500W ~ 3500W front panel 2.3 Rear panel features 300W ~ 1600W rear panel 1 AC input socket 2 Output sockets 3 Overcurrent protector 4 Buzzer for battery reverse 5 Battery wiring 6 Battery breaker 7 Fan Tower type Wall mounted type 6

8 9 10 DC output fuse MPPT (optional) DC output (optional) Optional model (with MPPT / DC modules) 2500W ~ 3500W rear panel 1 2 3 4 5 6 Input/output terminal block Overcurrent protector Battery breaker Buzzer for battery reverse Battery wring terminal Fan 7

3 Installation Instructions 3.1 Unpacking inspection Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged. 300W ~ 1600W package contents 300W ~ 1600W Inverter AC input power cords 2500W ~ 3500W package contents Operation manual 2500W ~ 3500W Inverter Operation manual 3.2 Installation CAUTION The inverter is designed for indoor use. Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Place batteries in sound ventilation environment. Use insulated tools to reduce the risk of short-circuit when installing or working with the inverter, the batteries, or other equipments attached to this unit. Be sure that the ground terminal has been connected with the ground. 3.2.1 Installation information Inspect whether the battery voltage and Mains voltage are correct or not. Connect the inverter with batteries, utility power and loads. Be sure all wiring is correct, terminals are screwed tightly and terminal cover is locked. Open the battery breaker, press ON button, then the inverter starts up in 3 seconds, and then check if the load has problem (overload, short-circuit ect.). If it does, check and correct until confirming it is normal, and then connect to the utility power. 8

3.2.2 Connect external battery 300W / 600W / 1000W inverter battery connection Optional model (with MPPT modules) (Note that the red cable is connected to the positive terminal, black cable is connected to the negative terminal) 1600W inverter battery connection Optional model (with MPPT modules) (Note that the red cable is connected to the positive terminal, black cable is connected to the negative terminal) 2500W / 3500W inverter battery connection (Note that the red cable is connected to the positive terminal, black cable is connected to the negative terminal, and 2500W battery cable is more than 35mm 2, 3500W battery cable is more than 50 mm 2 ) 9

4 Operations CAUTION Turn on the inverter in battery mode first. Be sure that the load has no problem (overload, short-circuit ect.) before connecting to utility power. 4.1 Turn the inverter On/Off Without connecting to utility power, press and hold ON button for 3 seconds, release it until the buzzer beeps, the inverter starts up. In the process of the inverter running, press and hold OFF button for 3 seconds, release it until the buzzer beeps, the inverter is shut down. When the inverter works in mains power / AC mode, press and hold OFF button for 3 seconds, release it until the buzzer beeps, the inverter goes to bypass mode. When the inverter works in bypass mode, press and hold ON button for 3 seconds, release it until the buzzer beeps, the inverter goes to AC mode. 4.2 Display interface Inverter mode Battery capacity Fan swing Mains power mode Inverter output frequency Load Load Inverter output voltage 4.3 Settings Input voltage 4.3.1 Setting operation Output voltage In normal mode, press and hold ON + OFF button at the same time for 3 seconds to go to Setup mode. In Setup mode, press and hold ON + OFF button at the same time for 3 seconds to exit from Setup mode, and the setting are not saved. In Setup mode, press ON button for page turning to select configuration options. In Setup mode, press OFF button to configure current settings. In Setup mode, press ON button to turn to page Save & Exit interface, press OFF button and select Y, then press ON button to confirm to save datas and exsit from Setup mode. After the setting is configured, shut down and restart the inverter before the settings takes effect. 10

In normal mode and starting state, press OFF button to mute. If there is failure and failure is solved, press OFF button first and release it to press ON button, and restart the inverter for normal use. 4.3.2 General settings Configure these settings at any time, using the display interface. No. Parameters Default Value Options LCD display 1 OUT: Rated output voltage of the inverter (option) 230V 220V / 230V / 240V 2 INP: Input power matching of the generator (option) 120% 10% ~ 120% (based on rated power) 3 HZ: Rated output frequency of the inverter (option) 50HZ 50HZ / 60HZ RANG: Input frequency range 4 setting (option) ± 5% ± 5% ~ ± 15% 5 B: Equalizing charge voltage (option) 14.1V 13.6V ~ 15.0V 6 F: Floating charge voltage (option) 13.5V 13.2V~14.6V 7 A: Battery low voltage alarm point setting (option) 10.8V 9.6V ~ 13.0V 8 E: End of discharge voltage (option) 10.2V 9.6V ~ 11.5V 9 CUR: Charging current (option) IECO: Inverter no-load ECO mode 10A (300W ) 20A (600W ~3500W) 0 ~ 60A 10 Note: If select Y, check whether the configured load rate in Inverter shutdown load rate is correct or not, if not, change it. (option) N Y / N 11

INLS: Inverter no-load shutdown function 11 Note: If select Y, check whether the configured load rate in Inverter shutdown load rate is correct or not, if not, change it. (option) N Y / N 12 13 INLS: Setting of the load rate of UPS auto-shutdown, The load rate of shutdown needed on the scene shall prevail during application. (Shall be taken as valid only when DC supply power) (option) INLS: Setting of the delay time of UPS auto-shutdown, When load setting value, the system will shut down after the configured time. (Shall be taken as valid only in battery mode) (option) 3 % 3 % ~ 50 % 1 min 1 ~ 99 min 14 ACAU: AC self-starting function (option) Y Y / N DCAU: DC auto restart function 15 Note: If select Y, check whether the configured time in DC auto N Y / N restart time is correct or not, if not, change it. (option) 16 T: DC auto restart time (option) 1H 0.5H ~ 8.0H 17 ITR: Input voltage display setting, displays the current rated voltage of the system; If select 100 / / 240, the input voltage displays 100V / / 240V, the transformer variable is the configured voltage value: rated voltage value. (option) OFF 200-240V UPS: OFF / 100 / 110 / 115 / 120; 100-120V UPS: OFF / 200 / 220 / 230 / 240 18 OTR: Output voltage display setting, displays the current rated voltage of the system; If select 100 / / 240, the output voltage displays 100 V/ /240 V, the transformer variable is the configured voltage value: rated voltage value. (option) OFF 200-240V UPS: OFF / 100 / 110 / 115 / 120; 100-120V UPS: OFF / 200 / 220 / 230 / 240 19 SAVE: Save and Exit Y / N 12

4.4 Troubleshooting This section lists the status and alarm messages that the UPS might display. A suggested corrective action is listed with each display message to help you troubleshoot problems. No. Problem Description Display Message Corrective Action 1 AC output short circuit Check if the load is short circuited. 2 AC output voltage is too high 3 AC output voltage is too low 4 Output overload Check the load. 5 Relay fault 6 MOSFET overcurrent 7 MOS overtemperature Decrease the operating load. Contact the dealer or supplier if the problem persists. 8 Connection of heat sink and temperature sensor abnormal 9 Transformer overtemperature Decrease the operating load. Contact the dealer or supplier if the problem persists. 10 Inverter AC output voltage is too high 11 Inverter AC output voltage is too low 13

12 Soft-start fault 13 BUS voltage is too high (Battery is overchargered ) Check the battery voltage. Contact the dealer or supplier if the problem persists. 14 Charging overcurrent 15 Battery voltage is too high Check the battery voltage. 16 Battery overdischarge protection Check the battery voltage 17 Fault self-locking Wait for auto clearance or manually shut down and restart the inverter 18 CT fault Check the CT signal line IPS-UPS Ul. Mikołowska 39 44-200 Rybnik, Poland 14