Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Similar documents
Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTION

ECONOMIZERS. 1/2012 Supersedes

Installation Instructions

ECONOMIZERS. 5/2012 Supersedes

Installation Instructions

Installation Instructions

Library Product Section Product Model Literature Type Sequence Date File No. Supersedes

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

Installation Instructions

Installation Instructions

Installation Instructions

CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Installation Instructions

Installation Instructions

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTIONS MODELS (-)XRD-MCCM3 & (-)XRD-MECM3/TECM3 CONVERTIBLE AIRFLOW ECONOMIZERS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

LF Series At A Glance

INSTALLATION INSTRUCTIONS

R81EAA-2 Economizer Circuit Board

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Installation Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

INSTALLATION INSTRUCTIONS MODELS (-)XRD-RGCM3 HORIZONTAL AIRFLOW ECONOMIZERS

MicroMetl. INSTALLATION INSTRUCTIONS Dual Stage Relief Economizer ECD-SRT12DR, ECD-SRT34DR, ECD-SRT5SDR & ECD-SRT5LDR

Installation, Operation and Maintenance Manual

& 76 CHEVROLET NOVA HEATER ONLY

Installation Instructions

Installation Instructions

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS


Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

SLIMZONE CLASSIC /

LF Series Spring Return Direct Coupled Actuator

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

CHP

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

INSTALLATION INSTRUCTION

INSTRUCTIONS FOR (-)XRX-AW04 or (-)XRX-AW05 MOTORIZED FRESH AIR DAMPER KIT

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Digital Room Thermostats with Touch Screen LCD

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

MA-5200 Series MA-5300 Series

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

REPLACEMENT PARTS MANUAL

D M S 760 C01 A A 1 1

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

INSTALLATION INSTRUCTIONS

Installation Instructions

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

Metasys Zoning Package Installation

REPLACEMENT PARTS MANUAL

SINGLE PACKAGE HEAT PUMPS

General Information... 2

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

2520- EC Motor Speed Controller

INSTALLATION INSTRUCTIONS

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

OVEN PARTS For Models:KEBC277KBL0, KEBC277KWH0, KEBC277KBT0 (Black) (White) (Biscuit)

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

Wiring Diagrams (Including Accessories) (50/60 Hz)

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Transcription:

ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully before beginning installation. For Down (for Horizontal Application go to page ) 1. Unpack top and bottom filter racks, and filters. Remove side panel on HVAC unit. ILL. 1 Compressor Compartment 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to right side of coil frame through pre-punched hole. Maximum screw length 1/2.. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to right side of coil frame. Maximum screw length 1/2.. Remove screw in the side of the HVAC unit and re-insert through prepunched hole in the end of top rack.. If using 2 wide filter, remove spacers from top and bottom filter racks. (ILL..) 6. To change filter: Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. (Note ) Note Side Panel shipped with HVAC unit. Remove and discard. Rack Detail ILL. 2 Top filter rack (Note ) Evaporator coil RIGHT SIDE Spacer for 1 filter ILL. Filter Bottom filter rack Width (Note 2) Qty. / Size 1 filter () 12 X 2 X 1 Bottom filter rack 2 filter () 12 X 2 X 2 Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. Form No. 02-1P Copyright MicroMetl Corporation 2007. All rights reserved.

Down ILL. 1 7 / 16 Install additional screw through HVAC unit flange into replacement panel. Replacement panel. Shipped with Coil economizer 2 9 / 16 Install / x 1/8 gasket along divider flange Divider Divider w/hvac unit /8 Alignment Holes flange 1/2 flange Gasket Top View Horizontal filter access door 2 7 / 16 Relief Blade Detail Damper actuator MicroMetl economizer Install / x 1/8 gasket along economizer bottom 28 ½ Add / x 1/8 gasket here. cover panel 7. Install the replacement panel (shipped with the economizer) over the compressor compartment of the HVAC unit. in place through the prepunched holes. NOTE: Top left hole will need to be field drilled. See ILL.. 8. Slide the economizer into the return air chamber, ILL.. Slide the economizer as far to the left as possible. The economizer's right side will slightly overlap the bottom filter rack. Be sure economizer is flat. 9. Install / x 1/8 gasket to bottom flange of economizer, see detail. Install gasket to HVAC unit divider. See detail. 10. Route the economizer wiring harness through the grommet in the economizer side (ILL. ) and through the HVAC units provided hole located in the upper part of the HVAC unit divider. (Install provided grommet in divider hole of HVAC unit. Follow the included harness routing diagram. (see page 9) 11. Install the economizer cover panel over the economizer. Slide panel underneath HVAC unit flange. in place to the divider in the HVAC unit, base and top. Also, align economizers /8 flange to the outside of 1/2 flange as shown and secure economizer cover panel to economizer using provided pre-punched alignment holes with 1 long tek screw. 2

1. After adjusting the minimum position setting on the actuator, screw the rainhood to the economizer panel through the prepunched holes. The top flange of the hood slips underneath the HVAC unit flange. Caulk hood perimeter. Install the aluminum filter in the rain hood. 1. Remove the cover panel shipped over the horizontal return opening. Locate the filter access panel and door latch. Install door latch angle. the hinge to the HVAC unit over the horizontal return opening. Adjust the closure handles for a tight seal. Install the provided filter access sticker on the hinged door. ILL. 6 Filters Down Rainhood ILL. 7 Horizontal supply air cover panel. Shipped on HVAC unit. SIDE VIEW Down Aluminum water entrainment filter (2 7/8 x 17 1/2 x 2) Replacement panel 1 1 8 Rainhood Door latch angle Filter access door - hinged Install filter access door sticker 1. Be sure the seams are all water tight. Seal as required. 1. Follow the wiring instructions enclosed. (see page 7,8) TOP VIEW ILL. 8 Filter rack Coil Unit panel Compressor Door latch angle DOOR LATCH ANGLE DETAIL Hinge Hood 0 Replacement Panel

Horizontal For Horizontal (for Down Application go to page 1) ILL. 1 1. Unpack top and bottom filter racks, and filters. Remove side panel on HVAC unit. 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to right side of coil frame through pre-punched hole. Maximum screw length 1/2. Compressor Compartment. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to right side of coil frame. Maximum screw length 1/2.. Remove screw in the side of the HVAC unit and re-insert through prepunched hole in the end of top rack.. If using 2 wide filter, remove spacer from top and bottom racks. ILL.. 6. To change filter: Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. (Note ) Note Side Panel shipped with HVAC unit. Remove and discard. Rack Detail ILL. 2 Top filter rack (Note ) Evaporator coil RIGHT SIDE Spacer for 1 filter ILL. Filter Bottom filter rack Width (Note 2) Qty. / Size 1 filter () 12 X 2 X 1 Bottom filter rack 2 filter () 12 X 2 X 2

ILL. Horizontal Install provided grommet in HVAC unit divider. Replacement panel Shipped with economizer Install / x 1/8 gasket along HVAC bottom 1 7/16 Install additional screw through unit flange into replacement panel. 2 9 / 16 Divider w/hvac unit Install / x 1/8 gasket along HVAC divider flange. Alignment holes 2 7 / 16 Coil Gasket cover panel Horizontal filter access door Rain hood Divider blank-off Blank-off blank-off (see detail) into base Detail Caulk these corners after Install / x /8 economizer is installed gasketing, sides. 6. Install the replacement panel over the compressor compartment. in place through the prepunched holes. NOTE: Top left hole will have to be field drilled. See ILL.. 7. Install provided economizer blank-off to bottom of economizer. See blank-off detail. in place through the pre-punched holes. 8. Install the / x /8 gasketing on the bottom flanges of the economizer (shaded area), ILL.. ( is shown in rotated position). 9. Rotate the economizer on its side as shown, ILL.. Slide the economizer into the cabinet and as far to the left as possible. The economizer will set against the left side of the HVAC unit. Caulk as required. Install the economizer cover panel over the economizer. Slide panel underneath HVAC unit flange. in place to the divider in the HVAC unit, base and top. 10. Align the economizer to the cover panel with 1 long tek screw using the provided pre-punched alignment holes. 28 ½ Remove molded gasket from economizer for horizontal application NOTE: The relief damper must be sealed shut for the horizontal discharge application.

Horizontal HVAC Unit ILL. Replacement panel shipped with economizer Filter access door for horizontal application Install filter access door sticker. Rainhood 11. Route the economizer wiring harness through the grommet in the economizer side and through the HVAC unit's provided hole located in the upper part of the HVAC unit divider. ILL.. (Install provided grommet in divider hole.) Follow the included harness routing diagram. (see page 9) 12. After adjusting the minimum position setting on the actuator, screw the rainhood to the economizer panel through the prepunched holes. The top flange of the hood slips underneath the HVAC unit flange. Caulk rainhood perimeter. Install the aluminum filter in the rainhood. Install the provided filter access sticker on the horizontal filter door. The side hinged panel and horizontal cover panel will not be used in the horizontal application. 16 1 1 / 8 1. Follow the wiring instructions.(see page 7, 8) ILL. 6 6

Minimum Position Wiring Diagram For s with Heat Pump Gray Equipment Transformer L1 L2 2 YELLOW ORANGE BROWN GREEN WHITE Main 2V Splice Box YEL. R1 N.O. 11 R1 11 Sensor resistor RED 9 TR Gray TR1 S O + 8 resistor S R + 620 7 6 1S 1K 1 2 1S1 2K ACTUATOR TR 2 VAC TR1 T T1 Orange Green Sensor s + Dry Bulb Outside Air Sensor (or optional enthalpy) 7 VOILET BLUE T P T1 P1 Min. Pos P1 P NOTES: RED 1 OPTIONAL LOW AMBIENT CONTROL. EQUIPMENT TRANSFORMER MUST BE SIZED TO ACCOMMO- 2 DATE AN ADDITIONAL 12VA. IF NOT, AN ADDITIONAL OPTIONAL TRANSFORMER IS REQUIRED. POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. MUST BE INSTALLED IN SUPPLY AIR STREAM. 000 OHMS AT 2ºC, 77ºF REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOM- ETER IS USED 1S IS AN ELECTRONIC SWITCH WHICH CLOSES WHEN 6 POWERED BY A 2 VAC INPUT. RELAY 1K & 2K ACTUATE WHEN THE OUTSIDE AIR SENSED 7 BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. FACTORY INSTALLED 620 OHM, 1 WATT, % RESISTOR SHOULD BE REMOVED ONLY IF AN ENTHALPY OR ADJUST- 8 ABLE DRY BULB SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL. 9 RESISTOR ONLY REQUIRED FOR FIXED DRY BULB. R1- RELAY IS FACTORY SUPPLIED AND FIELD INSTALLED. 11 MOUNT RELAY IN CONTROL BOX, ABOVE INDOOR FAN RELAY. Form No. 291-2PW2 R1 11 1 R W2 W1 G O Y1 THERMOSTAT Optional Remote Potentiometer Y2 CAUTION 1. Disconnect power supply before connecting wiring to prevent electrical shock or equipment damage L WIRING LEGEND Terminals Wire nut or equivalent connection MMC wiring harness Field supplied low voltage wire Field supplied high voltage wire Other low voltage wire

Wiring Diagram for s (no heat pump) 8 L1 L2 Equipment Transformer 2 CC Yellow Brown 1FR Green HC White Main 2V Splice Box Yel. Brn. Grn. Red Blue Resistor 9 Sensor TR S O S R 1 T P ACTUATOR TR1 + + 2 T1 P1 8 resistor 7 2K 1K 6 1S Gray Gray 1S1 Min. Pos TR 2 VAC TR1 T T1 P1 P Sensor Minimum Position Orange Green s + Dry Bulb outside air sensor (or optional enthalpy) 1 2 NOTES: Red Optional Low Ambient Control TRANSFORMER in HVAC Unit. POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Must be installed on supply air fan. 000 OHM at 2 C, 77 F 1 Optional Remote Potentiometer L WIRING LEGEND Terminals Wire nut of equivalent connection MMC wiring harness Field supplied low voltage wire Field supplied high voltage wire 6 7 8 9 Remove jumper when optional remote potentiometer is used. 1s is an electronic switch which closes when powered by a 2 vac input. Relay 1k & 2k actuate when the outside air sensed by the enthalpy or dry bulb is lower than the set point A-D. FACTORY INSTALLED 620 OHM, 1 WATT, % RESISTOR SHOULD BE REMOVED ONLY IF A SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL changeover. Resister only required for fixed dry bulb. R W1 G Y1 Y2 2- STAGE THERMOSTAT CC CC HC Other low voltage wire Compressor control Indoor fan control Gas / Electric heat control CAUTION 1. Disconnect power supply before connecting writing to prevent electrical shock or equipment damage.

Routing Wiring Harness Filter Damper actuator Damper logic module rainhood rainhood A ECONOMIZER CONTROLS INSTALLATION A Supply fan Supply fan Dry bulb or enthalpy (optional) Water entrainment filter in hood harness from actuator Main 2V splice box sensor. Field install. Coil Top View Wiring harness. Factory attached to economizer actuator. Factory run to splice box. Replacement panel shipped with economizer Main 2V splice box harness ACCESSORY SLIDE-IN ECONOMIZER CONTROL INSTALLATION. 1. Unpackage economizer. 2. Install accessory in unit per installation instructions provided.. Remove parts bag and instructions from inside of accessory.. Install the discharge sensor in the supply fan section. The sensor must protrude into the supply air stream. It should not interfere with blower, etc.. Uncoil the wiring harness. Connect the two gray wires of the harness to the discharge sensor leads using the two wire nuts provided. 6. Route the remainder of the wire harness through the unit to the main 2V splice box. 7. Mount thermostat downstairs per the manufacturer s instructions. Run proper wire from the thermostat to the unit control panel. 8. Review the MicroMetl wiring diagram from this booklet. Connect unit, wire from the thermostat and harness from the economizer, together to match the diagram. 9. Follow start-up instructions below. Damper actuator and dry bulb or enthalpy Compressor A-A Side View sensor. Field install. 10. Adjust change over setpoint on logic module. 11. Adjust minimum position set point on logic module. START-UP INSTRUCTIONS 1. After unit is wired begin start-up procedures. 2. Set thermostat functions to OFF. Set comfort levels to minimum cool and minimum heat.. Turn unit power on following manufacturer's start up instructions.. Turn thermostat fan function to ON. Unit indoor blower should start and damper motor will drive to minimum vent position. Minimum vent position should be adjusted on the economizer logic for the proper percentage of outdoor air.. Switch the thermostat function from OFF to HEAT or AUTO. Bring the comfort setpoint for heat up to engage first stage heating. Follow manufacturer s procedures to check heating cycle. Bring the comfort setpoint for heat up to engage second stage heating if available. Check this heating cycle also. 6. Under no circumstance should the economizer operate in a heating mode except for minium vent position. 9 7. Change the thermostat function from HEAT to COOL or leave in AUTO. Drop the comfort setpoint down to engage first stage call for cooling. The first stage cooling call travels to the economizer. If the outdoor air is above the A through D setpoint, (see chart on next page), the first stage mechanical cooling is brought on. As the comfort setpoint is reduced more there will be a second call for cooling which will bring on second stage mechanical cooling if available. 8. In the cooling mode if the outdoor air is below the setpoint, the first stage call for cooling will open the economizer. As the comfort setpoint is reduced more there will be a second call for cooling. This call will bring on the first stage mechanical cooling to back up the economizer. 9. Once all stages have been cycled, and all adjustments made return thermostat to its proper operating mode, replace all doors, panels and hoods. 10. Leave a copy of these instructions with the customer.

System Description These instructions are for fully modulating electronically controlled economizers utilizing solid state logic throughout. A standard single or (recommended) two stage thermostat is all that is needed to complete the control and economizer system for the HVAC equipment. 1 2 6 8 11 10 7 9 Component Description 1. Damper actuator... 9901-008 provides 2v modulating control of economizer dampers, 2 in. lb. of torque. (Honeywell M71A-1006) 2. Ball joint for linkage connection.. sensor... 9901-0001 provides a signal (000 Ohms at 2 C or 77 F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below. At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 0 F. to 6 F. discharge temperature.. Wire nuts to connect discharge sensor to the harness.. logic... 9901-0017 accepts input from discharge sensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment and enthalpy or adjustable dry bulb adjustment. When used with optional differential sensors in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W79A-1001) 6. Dry bulb...9901-018 senses temperature of outside air and provides signal to the economizer logic. Opens outside air at 60, closes outside air at 70 (enthalpy optional). 7. /8 grommet fits /8 hole that wires may pass through to keep from chaffing. 8. Wire clamps to secure wires to base, dividers, etc.. 9. Wire harness color coded and pre-wired to actuator and economizer logic... 9962-0087. 10. 1/2 hex head screws to secure wire clamps. 11. DPDT relay for heat pumps. 10

INTEGRATED ECONOMIZERS The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer is automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy (optional) conditions are low, the economizer actuator will proportion to maintain between 0º F and 6º F at thermistor discharge sensor. If the mixed or discharge temperature is above 6º F, actuator will open to admit additional outdoor air until the temperature returns to the 0º to 6º F range. If the mixed or discharge air temperature is below 0º F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 0º to 6º F range. During the occupied period, the actuator will not close past the minimum position. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. When in heating operation, or when outdoor air temperature or enthalpy (optional) conditions are high, economizer operation is locked out, and actuator is held at minimum position. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. 11

Minimum Position Adjustment The minimum position potentiometer keeps the outdoor air damper from closing completely during system operation to provide ventilation. 1. Make sure the factory installed jumper is in place across terminals P and P 1. 2. If remote control of dampers is desired, connect the remote potentiometer to P and P 1 and turn it fully clockwise before adjusting the minimum position.. Connect 2V AC to system and adjust the potentiometer on the face of the logic module with a screwdriver for desired minimum position. Enthalpy Changeover Setpoint (optional) Single enthalpy: The enthalpy changeover setpoints is set to return the outdoor air damper to minimum position when the enthalpy rises above its set point. The enthalpy setpoint scale markings, located on W79 are A,B,C,D as shown below. The factory-installed 620-ohm jumper must be in place across terminals + and S R unless using differential enthalpy. Differential Changeover Setting (optional) Differential enthalpy control (optional) utilizes two enthalpy sensors connected to one W79 Control. The enthalpy setpoint scale markings, located on the W79, are A,B,C,D. Turn the setpoint potentiometer fully clockwise past the D setting. The economizer will select the air with lower enthalpy for cooling; i.e., if outdoor air has lower enthalpy than return air, then the outdoor air damper will be opened to bring in outdoor air for free cooling. The differential enthalpy connects to S R and + on the W799 logic. Note: The C760A adjustable dry bulb can also be used for differential change over. Only the temperature of the outdoor air and return air will be compared and the best selected for free cooling. W79 Logic Module CAUTION Exercise care when adjusting the changeover set point and minimum position setting. EXCESSIVE FORCE MAY DAMAGE THE CONTROLS Enthalpy Changeover Set Point Minimum Damper Position Setting LED Lights up to indicate Outdoor Air is Suitable for Free Cooling Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. Form No. 02-1P Copyright MicroMetl Corporation 2007. All rights reserved. 12