Insulated Crimp Terminals

Similar documents
Enclosures & Consumables

Contents. Connectors - Crimp Terminals. Page

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n

web:

Insulated crimp terminals For reliable device connection

Termco Lugs and Terminals

CONTENTS UNINSULATED & PREINSULATE TERMINALS

Engineered installation products Solutions for control panel applications

Electrical. Hardware & Fastening Solutions. Battery Supplies. J-Case Fuses - Regular... Page 162

CONNECTORS - SINGLE POLE

023_quick splice_vinyl. Terminals & Cable Ties

K SERIES PUSH ON & BULLET TERMINALS

Fax: PO Box 100, 2222 Moore Rd. Jonesville, MI

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

PRODUCT CATALOG

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!!

TECHNICAL INFORMATION

Cable & Wiring Accessories

Cable & Wiring Accessories

Contents. 1. Wiring Terminals 2. Cable Ties and Fixings 3. Tools 4. Tapes 5. Heat Shrink Tubing 6. Automotive Range

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

ELECTRICAL TABLE OF CONTENTS

BATTERY. Connectors. Quick Cable products Lift Truck Parts Professionals

Pre-insulated terminals mm²

circuit protection & wiring accessories

FUSE & CIRCUIT PROTECTION

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

GENERAL CATALOGUE. Certified Quality. Management System. Certified Enviromental. Management System

PANAMF11 150KVa 3-pH AMF PANBASE Phase PANAMF KVa 3-pH AMF PANBASE Phase

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

General characteristics and technical data Series MCS

Water-Proof Connectors

Spade Terminals: Locking

HVAC No. MFG Part No. Description Price

Heavy Duty Copper Battery Terminals

Product Data Sheets. C.27/4 Series C.27/6 Series C.27/7 Series


circuit protection & wiring accessories

TERMINAL CLASSIFICATION OF PRODUCTS GENERAL INFORMATION

Get a FREE Storage Rack!

- 1 - General ordering data Order No

Cam switches, Indication, Pushbuttons

Engineer Solar Limited

CONTENTS TERMINAL BLOCKS

Circuit Breaker Types

C A B L E C O N N E C T O R S

...at Altech, of course!

HALOGEN FREE INSULATED TERMINALS OPERATING TEMPERATURE UP TO 115 C. Cond. Size sqmm (AWG) Quantity Box/Bag 0,2 0,5 (24 20) 0,25 1,5 (22 16)

AMF PANELS 3-PHASE (12V / 24V)

LOW PROFILE MINI FUSES AFTERMARKET MINI BLADE FUSES MINI BLADE FUSES. 34 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

KEY START PANELS 3-PHASE (12V / 24V) PANKEY Phase BASE LOAD PANELS 3-PHASE (12V / 24V)

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Tool sets. Contents. Tool sets. Tool sets H.1. Introduction H.2. Tool cases H.4. Crimp Sets and accessories H.5. Assortment boxes and cases H.

Circuit Breakers/Protection, Fuses/Fuse Products

Wiring Color Code - Direct Current Systems - Under 50 Volts

Fish Tapes... B-2 Fish Tape Accessories... B-6 Wire Pulling Lubricants... B-7 Accessories... B-11 Conduit Benders... B-12 Pulling Supplies...

Han-Power Energy Bus Components

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES

AMF PANELS 3-PHASE (12V / 24V) 25 kva 3-Ph AMF 12V Panel R R kva 3-Ph AMF 12V Panel R

BX8848 Installation Instructions 4 Diode Wiring Kit For Motorhomes With Red Tail Lights

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

FLEX-O-POWER FLEXIBLE WELDING

Specialty Electrical Supplies and Tools

Model C4 - Diagram #1

ELECTRICAL - Non Insulated Terminals

For a complete listing of kit contents, see page 225.

PLASTIC BOXES - WIRE DUCTS - DIN RAILS - CABLE TIES

THE UK S BENCHMARK FOR TRI-RATED CABLE

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

Terminal Overview Stud Sizes Solderless Terminals, Rings, Spades

Electrical Components & Accessories Catalogue TERMINATION CONNECTION PROTECTION BUNDLING IDENTIFICATION HARDWARE TOOLING KITS. carroll.com.

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

GROUNDING & BONDING PRODUCTS

Circuit Breaker Types

Electrical. Columbus Fleet Industrial Supply. Phone: Fax:

Distribution Blocks & Bus-bar Solutions

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

VINYL SOLDERLESS TERMINALS

Castle Model TSM-21 Standard Screw Pocket Machine

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

PREINSULATED COPPER TERMINALS

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Catalogue. Index INDUSTRIAL CABLE

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

Electronic Circuit Breaker ESS20-0..

INSTRUCTION, GPT LOW VOLTAGE THERMAL SWITCH (LVTS) INSTALLATION KIT P/N

VINYL SOLDERLESS TERMINALS

Battery Products. Call or Fax:

Data sheet chainflex CF8821

Cable connection technology

Timer Relays - Fixed & Adjustable

RMP SERIES INFORMATION GUIDE

ELECTRICAL WIRE AND FITTINGS

Tooling CONTENTS PAGE

Around the cable. Socket sleeves.... convincing solutions

General characteristics

Power cable accessories catalogue

Transcription:

CONTENTS PVC Insulated ring terminals 3 PVC insulated spade terminals 3 PVC insulated pin terminals 4 PVC insulated blade terminals 4 PVC insulated butt connectors 4 PVC insulated female disconnectors 5 PVC fully insulated female disconnectors 5 PVC insulated male disconnectors 5 PVC insulated piggy back disconnectors 5 PVC fully insulated receptacle disconnectors 6 PVC insulated bullet disconnectors 6 Twin Cord-end terminals 6 Nylon insulated cord-end terminals 7 Crimping tools 8 Coming Soon 9 Insulated Crimp Terminals revised 10.2.2011

INSULATED CRIMP TERMINALS R&D Technology s range of pre-insulated terminals is comprehensive, and is being developed continually as switchgear, contractors, terminal blocks etc evolve. In more recent years terminals have been getting smaller and we have developed our range of 0.5mm tab thickness quick connectors, increased our range of bootlace pins and introduced the 0.3mm range of terminals to name a few developments. Our terminals are of high quality, having many advanced features for ease of use. High quality product meeting the following International Standards ISO9001 UL Listed CUL Listed All terminals should be crimped onto the connector using an R&D Technology s crimper or any quality crimper that is designed to crimp the specifi c terminal type. If unsure of the terminal/conductor/crimper combination refer to the technical information following and test the nominal pull out force of the crimped connection. If the conductor does not pull out when the nominal pull out force is applied and held for one minute, this will give a good indication of the integrity of the joint. R&D Technology offer a range of crimpers for various applications and terminal types that are shown within this catalogue. Nominal Current Ratings and other specification (according to UL/cUL Standard) Terminal color Red Blue Yellow Wire Range (Sqmm) 0.5-1.5 1.5-2.5 4.0-6.0 Terminal Material Plating Maximum Volts Maximum Temp. Ring Terminal 19A 27A 48A 600V Forked Spade 19A 27A 48A Copper 600V 75 degree C for PVC Pin connector 19A 27A 48A 99.9% Pure insulated 600V 105 degree C for Nylon Flat Blade 19A 27A 48A 600V insulated Tin Bullet 10A 15A 24A 300V Quick Splice 10A 15A 24A Brass 70% Copper 600V 105 degree C 10A 15A 24A 30% Zinc 300V Quick Connector Strip length for Terminals 6.0mm 6.0mm 7.0mm 75 degree C for PVC insulated/105 degree C for Nylon insulated Nominal Pull Out Force (according to UL/cUL Standard) Wire size (Sqmm) Pull Out Force (kg) 0.32 3.6 0.52 5.9 0.82 9.1 1.3 13.6 2.1 22.7 3.3 31.8 5.3 36.3

PVC INSULATED RING TERMINALS PVC INSULATED SPADE TERMINALS 1. MAXIMUM ELECTRICAL RATING : 600 VOLTS 3. TERMINAL MATERIAL: COPPER 1. MAXIMUM ELECTRICAL RATING : 600 VOLTS 3. TERMINAL MATERIAL: COPPER 6 INSULATION MATERIAL: VINYL (PVC) STUD SIZE d2 DIMENSIONS mm B L F E D dl STUD SIZE d2 B L F E D dl R1-2VC 2.2 6.6 19.6 6.3 S1-3SVC 100 3.2 5.0 21.0 6.3 R1-3VC 100 3.2 5.5 16.7 4.0 S1-3VC 3.2 5.8 21.0 6.3 R1-3.5SVC 3.7 5.5 16.7 4.0 S1-3.5SVC 100 3.7 5.8 21.0 6.3 R1-3.5MVC 3.7 6.6 19.6 6.3 S1-3.5MVC 3.7 6.4 20.6 6.3 R1-3.5LVC 3.7 8.0 21.0 7.0 S1-3.5LVC 3.7 7.2 21.0 6.3 0.5-1.5 R1-4SVC 100 4.3 6.6 19.6 6.3 R1-4LVC 100 4.3 8.0 21.0 7.0 10.0 4.5 1.7 0.5-1.5 S1-4SVC 100 4.3 6.4 20.6 6.3 S1-4MVC 4.3 7.2 21.0 6.3 10.0 4.5 1.7 R1-5VC 100 5.3 8.0 21.0 7.0 S1-4LVC 4.3 8.0 21.0 7.0 R1-6VC 100 6.5 11.6 26.8 11.1 S1-5SVC 100 5.3 8.0 21.0 7.0 R1-8VC 100 8.4 11.6 26.8 11.1 S1-5LVC 5.3 9.5 21.0 7.0 R1-10VC 100 10.5 13.6 30.7 13.9 S1-6SVC 100 6.5 9.5 21.0 7.0 R1-12VC 13.0 19.2 35.6 16.0 S1-6LVC 6.5 12.0 27.2 11.0 R2-2VC 2.2 6.4 17.5 4.3 S1-8VC 8.4 12.0 27.2 11.0 R2-3VC 100 3.2 6.4 17.5 4.3 S2-3SVC 100 3.2 5.0 21.0 6.3 R2-3.5SVC 3.7 6.4 17.5 4.3 S2-3VC 3.2 5.8 21.0 6.3 R2-3.5MVC 3.7 6.6 19.5 6.3 S2-3.5SVC 100 3.7 5.8 21.0 6.3 R2-3.5LVC 3.7 8.5 22.0 7.8 S2-3.5MVC 3.7 6.4 21.0 6.3 R2-4SVC 100 4.3 6.6 19.5 6.3 S2-3.5LVC 3.7 7.2 21.2 6.5 1.5-2.5 R2-4LVC 4.3 8.5 22.0 7.8 10.0 5.0 2.3 S2-4SVC 4.3 6.4 21.0 6.3 R2-5SVC 100 5.3 8.5 22.0 7.8 1.5-2.5 S2-4MVC 4.3 7.2 21.2 6.5 10.0 5.0 2.3 R2-SLVC 5.3 9.5 22.0 7.3 S2-4LVC 4.3 8.5 22.0 7.3 R2-6VC 100 6.5 12.0 27.0 11.0 S2-5SVC 100 5.3 8.5 22.0 7.3 R2-8VC 100 8.4 12.0 27.0 11.0 S2-5LVC 5.3 9.5 22.0 (7.3 R2-10VC 100 10.5 13.6 30.7 13.9 S2-6SVC 100 6.5 9.5 22.0 7.3 R2-12VC 100 13.0 19.2 35.6 16.0 S2-6LVC 6.5 12.0 27.2 11.0 R5-3VC 3.2 7.2 22.5 5.9 S2-8VC 8.4 12.0 27.2 11.0 R5-3.5SVC 3.7 7.2 22.5 5.9 S5-3.5SVC 50 3.7 7.2 25.7 7.5 R5-3.5LVC 50 3.7 9.5 26.0 8.3 S5-3.5LVC 3.7 8.5 25.7 7.5 R5-4SVC 4.3 7.2 22.5 5.9 S5-4SVC 50 4.3 8.5 25.7 7.5 4-6 R5-4LVC 50 4.3 9.5 26.0 8.3 R5-5VC 5.3 9.5 26.0 8.3 13.0 6.8 3.4 4-6 S5-4LVC 4.3 9.5 25.7 7.5 S5-5VC 50 5.3 9.5 25.7 7.5 13.0 6.8 3.4 R5-6VC 50 6.5 12.0 29.5 10.5 S5-6SVC 50 6.5 9.5 25.7 7.5 R5-8VC 50 8.4 15.0 34.2 13.7 S5-6LVC 6.5 12.0 31.7 12.0 R5-10VC 50 10.5 15.0 34.2 13.7 S5-8VC 8.4 13.5 30.5 10.5) R5- I2VC 50 13.0 19.2 38.6 16.0 www.rdtechnology.com.au 3

PVC INSULATED PIN TERMINALS PVC INSULATED BLADE TERMINALS 1. MAXIMUM ELECTRICAL RATING : 600 VOLTS 3. TERMINAL MATERIAL: COPPER 6 INSULATION MATERIAL: VINYL (PVC) 1. MAXIMUM ELECTRICAL RATING : 600 VOLTS 3. TERMINAL MATERIAL: COPPER B L F E D dl B L F E D dl 0.5-1.5 1.5-2.5 PT1-9VC 19.5 9.5 PT1-10VC 20.5 10.5 PT1-12VC 100 1.9 22.5 12.5 10.0 4.5 1.7 PT1-13VC 23.5 13.5 PT1-18VC 28.5 18.5 PT2-9VC 19.5 9.5 PT2-10VC 20.5 10.5 PT2-12VC 100 1.9 22.5 12.5 10.0 5.0 2.3 PT2-13VC 23.5 13.5 PT2-18VC 28.5 18.5 4-6 P T 5-13VC 50 2.8 26.7 13.7 13.0 6.8 3.4 BT1-10VC 100 2.4 20.5 10.5 BT1-11VC 21.0 11.0 0.5-1.5 3.0 BT1-14VC 24.0 14.0 BT1-18VC 100 2.4 28.0 18.0 BT2-9VC 2.8 19.0 9.0 BT2-10VC 20.5 10.5 1.5-2.5 BT2-13VC 100 2.4 23.0 13.0 BT2-18VC 100 28.0 18.0 4-6 BT5-10VC 50 2.8 23.5 10.5 BT5-18VC 50 3.0 31.0 18.0 10.0 4.5 1.7 10.0 5.0 2.3 13.0 6.8 3.4 PVC INSULATED BUTT CONNECTORS 1. MAXIMUM ELECTRICAL RATING : 600 VOLTS 3. TERMINAL MATERIAL : COPPER STRIP 6. INSULATED MATERIAL : VINYL (PVC) L d D 0.5-1.5 WBC1VC 100 1.7 4.5 26.0 1.5-2.5 WBC2VC 100 2.3 5.0 4-6 WBC5VC 50 30.0 3.4 6.8 4 Insulated Crimp Terminals Catalogue

PVC INSULATED FEMALE DISCONNECTORS PVC FULLY INSULATED FEMALE DISCONNECTORS 2. MAXIMUM TEMPERATURE: 75 C 0.5-1.5 NEMA TAB F1-2.8VC/5 0.5*2.8 3.2 6.4 18.5 F1-2.8VC/8 0.8*2.8 F1-4.8VC/5 0.5*4.8 5.0 6.5 19.0 F1-4.8VC/8 0.8*4.8 F1-6.4VC 100 0.8*6.4 6.6 7.9 21.0 F1-8VC 0.8*8.0 8.4 10.0 24.0 B F L E D dl 10.0 4.3 1.7 F2-2.8VC/5 0.5*2.8 3.2 6.4 18.5 F2-2.8VC/8 0.8*2.8 F2-4.8VC/5 0.5 4.8 5.0 6.5 19.0 10.0 1.5-2.5 F2-4.8VC/8 0.8*4.8 5.0 2.3 F2-6.4VC 0.8*6.4 6.6 7.9 21.0 F2-8VC 0.8*8.0 8.4 10.0 24.0 F2-9.5VC 1.2*9.5 9.9 12.5 29.0 12.5 12.5 6.5 3.4 2 F5-6.4VC 0.8*6.4 6.6 7.9 23.5 4-6 mm F5-9.5VC 1.2*9.5 9.9 12.5 28.5 2. MAXIMUM TEMPERATURE: 75 C 0.5-1.5 NEMA TAB F1-2.8VFC/5 0.5*2.8 3.2 6.4 19.0 F1-2.8VFC/8 0.8*2.8 F1-4.8VFC/5 0.5*4.8 5.0 6.5 20.0 F1-4.8VFC/8 0.8*4.8 F1-6.4VFC 100 0.8*6.4 6.6 7.9 22.0 B F L E D dl 10.0 4.3 1.7 F2-2.8VFC/5 0.5*2.8 3.2 6.4 19.0 F2-2.8VFC/8 0.8*2.8 1.5-2.5 F2-4.8VFC/5 0.5*4.8 10.0 5.0 2.3 5.0 6.5 20.0 F2-4.8VFC/8 0.8*4.8 F2-6.4VFC 100 0.8*6.4 6.6 7.9 22.0 4-6 F5-6.4VFC 50 0.8*6.4 6.6 7.9 25.0 13.0 6.5 3.4 PVC INSULATED MALE DISCONNECTORS PVC INSULATED PIGGY BACK DISCONNECTORS NEMA TAB DIMENSIONS inch (mm) B B1 F Fl L E D dl 0.5-1.5 PB1-6.4VFC 100 4.3 1.7 21.0 10.0 1.5-2.5 PB2-6.4VFC 100 0.8*6.4 6.6 6.4 8.0 8.2 5.0 2.3 4-6 PB5-6.4VFC 50 23.5 12.5 6.5 3.4 0.5-1.5 1.5-2.5 NEMA TAB M1-2.8VC/5 0.5*2.8 7.0 19.2 2.8 M1-2.8VC/8 0.8*2.8 7.8 20.5 M1-4.8VC/5 0.5*4.8 7.0 19.2 4.8 M1-4.8VC/8 0.8*4.8 20.5 7.8 M1-6.4VC 100 0.8*6.4 6.4 21.2 M2-2.8VC/5 0.5*2.8 7.0 19.2 2.8 M2-2.8VC/8 0.8*2.8 7.8 20.5 M2-4.8VC/5 0.5*4.8 7.0 19.2 4.8 M2-4.8VC/8 0.8*4.8 20.5 7.8 M2-6.4VC 100 0.8*6.4 6.4 21.2 B F L E D dl 10.0 4.3 1.7 10.0 5.0 2.3 4-6 M5-6.4VC 50 0.8*6.4 6.4 7.8 23.7 12.5 6.5 3.4 www.rdtechnology.com.au 5

PVC FULLY INSULATED RECEPTACLE DISCONNECTORS PVC INSULATED BULLET DISCONNECTORS B F L E D dl B F L E D dl 0.5-1.5 RE1-4VFC 100 4.3 1.7 4.0 RE2-4VFC 23.5 11.0 1.5-2.5 5.0 2.3 9.0 RE2-5VFC 100 5.0 4-6 RE5-5VFC 50 25.0 13.0 6.5 3.4 0.5-1.5 BD1-4VC 100 4.3 1.7 4.0 BD2-4VC 21.0 10.0 1.5-2.5 8.5 5.0 2.3 BD2-5VC 100 5.0 4-6 BD5-5VC 50 23.5 13.0 6.5 3.4 TWIN CORD-END TERMINALS (DIN 46228/4) 1. TEMPERATURE RANGE : -40 C UP TO +105 C 2. TERMINAL MATERIAL: COPPER TUBE 3. PLATING: ELECTRO TIN PLATED 4. INSULATION MATERIAL: NYLON PACK COLOUR F L C W1 W2 SYSTEM 2 x 0.5 CT205008 8.0 15.0 1.5 4.7 2.5 WHITE 2 x 0.75 2 x 1.0 2 x 1.5 2 x 2.5 CT207508 500 8.0 15.0 CT207510 10.0 17.0 CT210008 500 8.0 15.0 CT210010 10.0 17.0 CT215008 500 8.0 16.0 CT215012 12.0 20.0 CT225010 500 10.0 18.5 CT225013 13.0 21.5 1.8 5.0 2.8 GREY 2.05 5.4 3.4 RED 2.3 6.6 3.6 BLACK 2.8 7.8 4.2 BLUE 2 x 4.0 CT240012 500 12.0 23.0 3.7 8.8 4.9 GREY 2 x 6.0 CT260014 500 14.0 26.0 4.8 10.0 6.9 YELLOW 2 x 10.0 CT210014 14.0 26.5 6.4 12.8 7.6 RED 2 x 16.0 CT216014 14.0 31.5 8.3 18.6 9.6 BLUE 6 Insulated Crimp Terminals Catalogue

NYLON INSULATED CORD-END TERMINALS (DIN 46228/4) 1. TEMPERATURE RANGE : -40 C UP TO +105 C 2. TERMINAL MATERIAL: COPPER TUBE 3. PLATING: ELECTRO TIN PLATED 4. INSULATION MATERIAL: NYLON PACK F F L C W COLOUR SYSTEM 0.14 0.25 0.34 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 CE001406 6.0 10.0 CE001408 8.0 12.0 CE002506 6.0 10.0 CE002508 8.0 12.0 CE003406 6.0 10.0 CE003408 8.0 12.0 CE005006 6.0 12.0 CE005008 500 8.0 14.0 CE005010 10.0 16.0 CE007506 6.0 12.0 CE007508 8.0 14.0 CE007510 500 10.0 16.0 CE007512 12.0 18.0 CE010006 6.0 12.0 CE010008 500 8.0 14.0 CE010010 10.0 16.0 CE010012 12.0 18.0 CE015008 500 8.0 14.0 CE015010 10.0 16.0 CE015012 12.0 18.0 CE015018 500 18.0 24.0 CE025008 500 8.0 14.0 CE025010 10.0 16.0 CE025012 12.0 18.0 CE025018 500 18.0 24.0 CE040010 500 10.0 16.0 CE040012 12.0 18.0 CE040018 500 18.0 24.0 CE060012 500 12.0 20.0 CE060018 500 18.0 26.0 CE100012 12.0 22.0 CE100018 18.0 28.0 CE160012 12.0 24.0 CE160018 18.0 28.0 CE250016 16.0 30.0 CE250022 22.0 36.0 CE350016 16.0 30.0 CE350018 18.0 32.0 CE350025 25.0 39.0 CE500020 20.0 36.0 CE500025 25.0 40.0.70 1.6.75 1.9 VIOLET.80 1.9 PINK 1.0 2.6 WHITE 1.2 2.8 BLUE 1.4 3.0 RED 1.7 3.5 BLACK 2.2 4.2 GREY 2.8 4.8 ORANGE 3.5 6.3 GREEN 4.5 7.6 BROWN 5.8 8.8 IVORY 7.3 11.2 BBLACK 8.3 12.7 RED 10.3 15.0 BLUE 70 CE700021 21.0 37.0 13.5 16.0 YELLOW 95 CE950025 25.0 44.0 14.7 18.0 RED 120 CE120027 27.0 48.0 16.7 20.0 BLUE 150 CE150032 32.0 58.0 19.5 23.0 YELLOW www.rdtechnology.com.au 7

CRIMPING TOOLS JSL307 FOR INSULATED CORD END TERMINALS :0.25~2.5mm² JSL1305-1 FOR 2 PCS INSULATED TERMINALS AND CONNECTORS (SINGLE CRIMP) OR 3 PCS INSULATED DISCONNECTORS (DOUBLE CRIMP) : 0.5~1.5mm²=22~16AWG 1.5~2.5mm²=16~14AWG 4~6mm²=12~10AWG JSL1305-2 FOR 3 PCS INSULATED TERMINALS AND CONNECTORS (DOUBLE CRIMP) : 0.5~1.5mm²=22~16AWG 1.5~2.5mm²=16~14AWG 4~6mm²=12~10AWG JSL1370 FOR CORD END TERMINALS : 0.5~4.0mm² JSL1371 8 Insulated Crimp Terminals Catalogue

Coming Soon WIRING DUCT Wiring Duct available in slotted, closed & open or solid wall variations. High impact strength self extinguishing 94V-0 PVC Service temperature 85 o C SPIRAL BANDING Manufactured from P. E. Binds Cables and protects them from damage CABLE TIE SADDLES Available in Screw-in or Stick-on Colour - White CABLE TIES Manufactured from UL approved Nylon 66 94V-2 Service Temperature -40 O C to + 105 O C One piece design ensures strong locking Packed Quantity 100 CABLE GLANDS Manufactured from UL approved Nylon 66 94V-2 black Temperature -40 O C to + 105 O C Cable Grab Claw stays on gland body to reduce installation time IP68 rating www.rdtechnology.com.au 9