ISO 9002 Hansen Technologies Corp. Burr Ridge, IL Cert. # Orlando, FL Cert. #

Similar documents
Specifications, Applications, Service Instructions & Parts. HCK1, HCK1W PISTON-TYPE CHECK VALVE ¾" thru 6" (20 thru 150 mm)

Specifications, Applications, Service Instructions & Parts. Flanged and Weld-in 3/4" thru 4" Port (20 mm thru 100 mm) for Refrigerants

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Refrigerating Specialties Division 1. BULLETIN DN23-05B Type A4A-DN, A4AK-DN, A4AE-DN, A4AR-DN. January 2007 Installation and Service Information

Specifications, Applications, Service Instructions & Parts. Butt Weld Shut-off valves

Specifications, Applications, Service Instructions & Parts BUTT WELD SHUT-OFF VALVES

Specifications, Applications, Service Instructions & Parts. Socket Weld Shut-off valves

BULLETIN Type A4AM. March 2002 Installation, Service and Parts Instruction. Refrigerating Specialties Division Fig.

Hand Shut-Off Valves for Standard and Extended Bonnets

Specifications, Applications, Service Instructions & Parts SEALED MOTOR VALVE & CONTROLLERS

Specifications, Applications, Service Instructions & Parts MOTORIZED CONTROL VALVE & CONTROLLERS

Industrial Refrigeration Control Valves. Catalog C12

ADAPTOMODE INLET PRESSURE REGULATORS Types: A4AS, A4AB, A4AD, A4AZ

Parker Weld-in Valve Stations

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Operator Installation & Instructions HERMETIC LIQUID REFRIGERANT PUMPS CAM AND CNF SERIES

CV Control Valves Installation and Operation Manual

t EVAPORATOR PRESSURE REGULATING VALVES

Pilot operated main valves for regulating pressure and temperature, type PM

Shut-off Check valves and regulating valves for for Industrial Refrigeration

SERIES 270A HIGH SIDE FLOAT VALVES BULLETIN 270A-SB11-02 SERVICE BULLETIN

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Installation, Operation and Maintenance Manual

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

2017 LIST PRICE SCHEDULE & PARTS LIST PRICING

Installation, Operation and Maintenance Instructions

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

611H Flo-Con Pressure Regulators & Valves

EVAPORATOR PRESSURE REGULATORS

Pilot-operated servo valve Type ICS

Pressure control valve Type KDC

Installation, Operation & Maintenance Manual

Valve Station in stainless steel ICF SS 20 and ICF SS 25

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

Crispin Valves Operating Guide. Crispin

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

SECTION METERS AND GAGES FOR PLUMBING PIPING

Type 644 and 645 Differential Pressure Pump Governors

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Check & stop valve, SCA-X Check valve, CHV-X

Hansen Introduction Stop And Regulating Valves Pressure Regulators Control Valve Pilots

NECO Pumping Systems

Valve Station ICF 20-40

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Pilot-operated servo valve Type ICS

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Pilot controlled servo valves Type ICS - Solenoid Valves Pressure Regulating Valves. Technical leaflet MAKING MODERN LIVING POSSIBLE

Shut-off Check valves and regulating valves for for Industrial Refrigeration

GT-200 GATE VALVES PN16, Screwed end

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Pilot-operated servo valve Type ICS

Solenoid valves type EVRA 3 to 40 and EVRAT 10 to 20

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SECTION Pressure & Temperature Control

PRESSURE REDUCING VALVE

GP-2000 : Trouble Shooting. Cause of problems

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Solenoid valves EVRA and EVRAT

PRESSURE REDUCING CONTROL VALVE

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

270A SERIES HIGH-SIDE FLOAT VALVES BULLETIN 270A-SB13-01 SERVICE BULLETIN

Colt Series C400, C500

1090, 1170 & 1175 Volume 1 of 2

THIS WARRANTY IS IN LIEU

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

Installation Instructions

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

Stop check valves type SCA , SCA-SS Check valves type CHV , CHV-SS Technical leaflet REFRIGERATION AND AIR CONDITIONING

Condensed Catalog 410A January 2008

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Series 867 Reduced Pressure Zone Assemblies

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

CIRCLE SEAL CONTROLS

Stop check valves, SCA-X Check valves, CHV-X

Parts List. Item # Part # # Reqd. Description

PRESSURE REDUCING VALVE

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

PRESSURE REDUCING VALVE

MODEL G-15 VERTICAL AMMONIA COMPRESSORS

Purging Air From Divider Block Lubrication Systems

CIRCLE SEAL CONTROLS

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

GROOVED END FLO-TREX COMBINATION VALVE

ATMOSPHERIC RELIEF VALVE

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Porta-Punch Manual

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Shut-off valves Types SVA-S and SVA-L

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

Pilot-Operated Regulators

Transcription:

HANSEN CORPORATION TECHNOLOGIES Specifications, Applications, Service Instructions & Parts HCK, HCKW PISTON-TYPE CHECK VALVE ¾" thru 6" (0 thru 50 mm) Flanged ¾" thru " FPT, SW, WN, ODS for refrigerants Piston-Type Check Valve: " HCK ISO 900 Hansen Technologies Corp. Burr Ridge, IL Cert. # 0007 Orlando, FL Cert. # 0053 INTRODUCTION These flanged, heavy-duty, piston-type check valves control the flow of refrigerant. Valves open wide for flow in the direction of the arrow on the valve body. Valves close tight when flow reversals occur. The piston design minimizes pulsations. Valves open when inlet pressure exceeds outlet pressure ( psid [.07 bar] minimum), thereby lifting the piston/seat assembly and allowing flow through the valve. When inlet pressure and outlet pressure are equalized, the weight of the piston/seat assembly causes the valve to close. If outlet pressure exceeds inlet pressure, the outlet pressure acting on top of the piston/seat also helps seat the valve closed. Also available, Type HCK in-line check valves and Type SCK combination stop/check valves; contact Hansen KEY FEATURES ADVANTAGES This normally closed valve requires very little pressure drop to operate. Valve sizes ¾" thru ¼" have spring-assisted closing. Valve sizes ½" thru 6" have a special, spool-type, dirt-resistant piston/ seat. A manual opening stem allows positive opening during servicing or troubleshooting the system. The flange-to-flange dimension and flange pattern are the same as the Parker R/S allowing this valve to be dropped in without main line piping changes (exception: ¼"). APPLICATIONS The HCK piston-type check valve prevents reverse flow of refrigerant in liquid, discharge, suction, and hot gas lines. It is an ideal valve where constant pulsating of gas or liquid is present, or where a manual opening of the valve is desirable. This valve is suitable for ammonia, R, R3a, and other common refrigerants.

MATERIAL SPECIFICATIONS Body: ¾" thru ": Ductile iron ASTM A536 65,000 psi tensile (nodular iron GGG-0) 5" & 6": Cast steel Piston/Seat: ¾" thru ¼": Stainless steel with Teflon seat ½" thru 6": Ductile iron, ASTM A536 Closing Spring: Stainless steel (¾" thru ¼" only) Gaskets: Nonasbestos, graphite composite Stem: Plated steel Cover: Steel Stem Seal: O-ring plus graphite composite packing Companion Flanges: Forged steel Safe Working Pressure: 00 psig (7 bar) Operating Temperature: 5F to +50F ( 3 to + C) INSTALLATION Protect the interior of the valve from dirt and moisture during storage and installation. The valve must be installed upright in a horizontal line. The arrow on the valve body should be in the normal direction of refrigerant flow. The system should be free of dirt, weld slag, and rust particles. Install the valve in an accessible location for servicing. Do not install a check valve at the inlet of a solenoid valve or regulator with electric shut-off. Do not install a check valve at the inlet of an outlet regulator where liquid may be trapped between the valves. Check valves in general, when installed, should be at the outlet of control valves to avoid trapping refrigerant between the valves. SIZING The same care should be taken when sizing check valves as with any other type of control valve. Check valves should be sized so that the valve is fully open under all normal operating conditions. Also, the check valve port size is not always the same as the line size. This is particularly true for gas flow in compressor discharge lines and hot gas lines. Under some conditions, the port size of a properly-selected check valve can be one or two sizes smaller than the line. The pressure drop across the HCK check valve should normally be to 5 psi under full load conditions. In addition, the pressure drop across the check valve at normal minimum load should be determined. For the Hansen HCK check valve, a minimum of psi at minimum load is required to ensure that the valve is fully open during all normal flow conditions. CAPACITIES (Tons) ( Ton=,000 Btu/hr= 3.57 kw= 30 kcal/hr) REFRIG. R77 R APPLICATIONS DESCRIPTION Discharge Line Compressor Sideport Liquid Line Discharge Line Compressor Sideport Liquid Line Cv (Kv) P ¾" (3) " (3) ¼" (3) ½" (0) PORT SIZE (mm) " (50) ½" (65) 3" (0) " (00) 5" (5) 6" (50) psi 9 50 33 750 95 5 psi 3 5 69 00 3 37 535 73 7 9 psi 6 5 7 36 93 -- -- -- 5 psi 9 5 3 0 9 09 96 -- -- -- TONS psi 09 7 5 7 35 3 39 703 -- -- GPM psi 9 3 97 57 6 -- -- psi 7.5 9. 5 5 3 59 3 5 psi 6 70 33 9 55 675 psi.7 6. 9.6 7 3 5 7 -- -- -- 5 psi 7. 9.5 5 50 0 -- -- -- TONS psi 63 97 330 53 756 656 -- -- GPM psi 9.9 3 0 5 6 0 56 3 -- -- (7) 0.5 (9) 6.3 () 7 (0) 55 (7) psi = 0. bar 5 psi = 0.35 bar U.S. GPM (gallons per minute) = 0.7 m 3 /hr 9 (76) 6 (0) 76 (36) 350 (300) Discharge line capacities based on +6F (+30 C) condenser, +0F (+60 C) discharge, and +5F ( 9. C) evaporator. Compressor sideport capacities based on +0F ( 6.7 C) economizer and +6F (+30 C) condensing. 50 (35) Liquid line capacities based on +0F ( 6.7 C) liquid and +5F ( 5 C) evaporator, with no flashing through valve. To convert to +6F (+30 C) liquid, multiply values in table by 0.9. To convert R capacities to R3a, multiply tons in table by 0.9 (accuracy within %). GPM correction factors for temperatures between 0F ( 0 C) and +0F (+. C) are negligible.

TYPICAL APPLICATIONS DISCHARGE LINE COMPRESSOR SIDEPORT INTERMEDIATE PRESSURE GAS TO COMPRESSOR SUCTION HCK PISTON-TYPE CHECK VALVE ECONOMIZER COOLER PUMP DISCHARGE LINE TRANSFER SYSTEM PUMP ACCUMULATOR VENT/BYPASS LINE LIQUID RELIEF HCK PISTON-TYPE CHECK VALVE The above are schematic drawings of fictional refrigeration systems to show Hansen product applications in a system. These drawings should not be used for design or construction. 3

INSTALLATION DIMENSIONS ¾" thru " (0 mm thru 00 mm) 5" & 6" (5 mm & 50 mm) 0.0" (5 mm) PORT SIZE (mm) ¾", " (0), (5) ¼" (3) ½", " (0), (50) ½" (65) 3" (0) " (00) 5" (5) 6" (50) HCK Flange-to-flange dimensions (L) are the same as the Parker R/S Type CK, except ¼", 5", and 6". L H H FPT, SW." (07)." (07) 7." ().06" (05).3" (3) 9." (5).3" (30).3" (30).30" (0).30" (0) 5.3" (36) 6.0" (55) 6.56" (67) 7.3" (7).3" (36).3" (36).0" (0).0" (0).39" (35) 3.0" (330) 5.3" (39) 7.0" (3) DIMENSIONS (mm) WN, ODS.9" (7).9" (7) 3.39" (30).03" (356) 6.0" (7) 0.5" (5) L * L W ** 6.9" (57) 6.9" (57) 9." (5) 9." (5).5" (3)." (359) 7.0" (3) 7.0" (3) 0.9" (77).0" (0) 3.3" (30) 5.0" (3) -- -- -- -- -- -- -- -- *L is the flange face-to-face dimension. **W dimension is the maximum width of the valve..50" ().50" ().50" () 5.6" (3) 6.50" (65).06" (05).75" (3).75" (3)

HCK PARTS LIST, ¾" thru ¼" (0 mm thru 3 mm) ITEM DESCRIPTION QTY PART NO. a b 3 Piston/Seat Kit ¾", " Piston/Seat Kit ¼" Above kits consist of: xxpiston/seat ¾", " xxpiston/seat ¼" xxclosing Spring xxcover O-ring, Lower xxcover O-ring, Upper 70-09 70-0 70-063 70-067 70-055 70-030 70-03 3 5 6 7 9 Gasket Kit ¾", ", ¼" Above kit consists of: xxcover O-ring, Lower xxcover O-ring, Upper xxstem O-ring xxstem Washer xxpacking xxpacking Nut xxseal Cap O-ring xxflange Gasket 70-07 70-030 70-03 70-000 70-006 70-005 70-009 70-00 70-03 9 0 xxseal Cap xxseal Cap O-ring xxstem 50-0 70-00 70-0 3a 3b 5 6 7 Cover Body ¾", " Body ¼" Flange (various) Bolt ( 5 /"- x 3 /") Nut ( 5 /"-) 70-0307 70-0369 70-0369 FACTORY 70-0339 70-036 5

HCK PARTS LIST, ½" thru " (0 mm thru 00 mm) ITEM DESCRIPTION QTY PART NO. a b c a b c a b c 3a 3b a b 5a 5b 6a 6b 7a 7b a b a b c d Piston/Seat Kit ½", " Piston/Seat Kit ½" Piston/Seat Kit 3" Piston/Seat Kit " Above kits consist of: xxpiston/seat ½", " xxpiston/seat ½", 3" xxpiston/seat " xxcover Gasket ½", " xxcover Gasket ½", 3" xxcover Gasket " Gasket Kit ½", " Gasket Kit ½" Gasket Kit 3" Gasket Kit " Above kits consist of: xxcover Gasket ½", " xxcover Gasket ½", 3" xxcover Gasket " xxback-up Washer ½", ", ½", 3" xxback-up Washer " xxstem O-ring ½", ", ½", 3" xxstem O-ring " xxstem Washer ½", ", ½", 3" xxstem Washer " xxpacking ½", ", ½", 3" xxpacking " xxpacking Nut ½", ", ½", 3" xxpacking Nut " xxseal Cap O-ring ½", ", ½", 3" xxseal Cap Gasket " xxflange Gasket ½ ", " xxflange Gasket ½ " xxflange Gasket 3" xxflange Gasket " 75-00 75-005 75-006 75-0 75-0 75-0 75-0 75-096 75-0 75-03 75-007 75-00 75-009 75-07 75-096 75-0 75-03 75-05 50-035 50-079 50-053 50-006 50-07 50-005 50-0 50-003 50-05 50-03 50-070 75-03 75-05 75-037 75-053 ITEM DESCRIPTION QTY PART NO. 9a 9b 9c 0a 0b a b c a b c 3a 3b 3c 3d 3e 5 6a 6b 6c 7a 7b 7c Stem ½", ", ½" Stem 3" Stem " Seal Cap ½", ", ½", 3" Seal Cap " Cover ½", " Cover ½", 3" Cover " Cover Bolts ½", " Cover Bolts ½", 3" Cover Bolts " Body ½" Body " Body ½" Body 3" Body " Flange (various) Flange Bolt ½", "( 5 /"- x 3 /") Flange Bolt ½", 3"(¾"-0 x 3¾") Flange Bolt "( 7 /"-9 x ") Flange Nut ½", "( 5 /"-) Flange Nut ½", 3" (¾"-0) Flange Nut "( 7 /"-9) 75-0 75-035 75-0 75-039 50-060 75-007 75-0 75-03 75-075 65-0057 75-09 75-097 75-097 75-0 75-09 75-03 FACTORY 70-035 75-00 75-079 70-036 75-00 75-00 6

HCKW PARTS LIST, 5" & 6" (5 mm & 50 mm) ITEM DESCRIPTION QTY PART NO a b 3 5 6 7 9 0 3 a b xpiston/seat 5" xpiston/seat 6" xcover O-ring, Inner, 5" & 6" xcover O-ring, Outer, 5" & 6" xback-up Washer xstem Seal O-ring xstem Washer xpacking xpacking Nut xseal Cap Gasket xstem xseal Cap xcover xcover Bolts xbody 5" xbody 6" 7 75-066 75-060 75-0605 75-0606 50-03 50-093 50-099 50-090 50-09 50-035 75-05 50-030 75-053 75-060 75-063 75-0639

SERVICE AND MAINTENANCE Failure to Close: The manual opening stem is turned in, mechanically holding the piston/seat open. Dirt may be lodged between the piston/seat and the valve piston wall. Failure to Open: The pressure difference is not high enough. Inlet pressure must be at least psi above outlet pressure. Adjacent shut-off valves or control valves are not open. Dirt may be lodged between the piston/seat and valve piston wall. Manual Operation: If it is necessary to manually hold open the HCK valve, remove the seal cap cautiously. There may be a small amount of refrigerant trapped in it. Turn the manual opening stem inward (clockwise) as far as possible. The piston/seat is then mechanically held open. The valve cannot close until the manual opening stem is turned out (counter-clockwise). If it is necessary to remove or disassemble the valve for servicing, be sure it is completely isolated from the refrigeration system and all refrigerant is removed (pumped out to zero pressure). Be sure to follow refrigeration system safety procedures and read the Caution section in this bulletin. To inspect valve interior, slowly loosen the screwed cover or four cover bolts equally, being careful to avoid any refrigerant which may still remain. Remove the piston/ seat. Then clean and inspect for burrs and damage to the seating surfaces. Slight marks and burrs can often be removed by hand with emery paper or by power lapping. Damaged parts should be replaced. Lightly lubricate the main valve interior bore with refrigerant oil, and install the piston/seat and closing spring (a closing spring is used in ¾" - ¼" valves only). Replace the cover, gasket and bolts (½" - 6"). Carefully check the entire valve for leaks before restoring the valve to service. CAUTION Hansen valves are only for refrigeration systems. These instructions and related safety precautions must be completely read and understood before selecting, using, or servicing these valves. Only knowledgeable, trained refrigeration mechanics should install, operate, or service these valves. Stated temperature and pressure limits should not be exceeded. The valve cover or pilot line should not be removed from valves unless the system has been evacuated to zero pressure. See also Safety Precautions in the current List Price Bulletin and the Safety Precautions Sheet supplied with the product. Escaping refrigerant might cause injury, particularly to the eyes and lungs. ORDERING INFORMATION, PISTON-TYPE CHECK VALVES PORT SIZE (mm) FLANGE STYLE AND SIZES CONNECTIONS AVAILABLE SW, WN, FPT ODS STD ALSO STD ¾"x(0) ¾" ", ¼" 7 /" "x(5) " ¾", ¼" /" ¼"x(3) * ¼" ", ¾" 3 /" ½"x(0) ½" " 5 /" "x(50) " ½" /" ½"x(65) ½" 3" 5 /" 3"x(0) 3" -- 3 /" "x(00) " -- /" 5"x(5) ** 5" BW -- -- 6"x(50) ** 6" BW -- -- * ¾", ", and ¼" valves are -bolt design. **5" & 6" are integral butt weld only, Type HCKW. To Order: Specify Type HCK (or HCKW), port size, flange connection style and size. TYPICAL SPECIFICATIONS Piston-type check valves shall be ductile iron or steel bodied, normally closed, with a manual opening stem, as manufactured by Hansen Technologies Corporation or approved equal. OTHER PRODUCTS Ammonia Pressure-Relief Valves Gauge, Purge, and Needle Valves Shut-off Valves Expansion Valves (Regulators) Refrigerant Solenoid Valves Refrigerant Pressure Regulators Small Pressure Regulators Refrigerant Check Valves Strainers Gas-Powered Valves Refrigerant Float Switches Float Regulators (High Side) Refrigerant Liquid Pumps AUTO-PURGER Non-condensable Gas Purgers Vari-Level Adjustable Level Controls Techni-Level Transducer Probes Frost Master Defrost Controllers SEE-LEVEL Refrigerant Liquid Indicators WARRANTY Hansen valves are guaranteed against defective materials or workmanship for one year F.O.B. factory. No consequential damages or field labor is included.