SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Similar documents
Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Braking Module / braking resistor SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation. Connection 4

Siemens Drives & PLCs

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

Products for specific requirements

Industrial Controls. Load Feeders and Motor Starters. SIRIUS MCU Motor Starters. Gerätehandbuch. Answers for industry.

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

SINAMICS DCM DC Converter, Control Module

Safety Integrated for entry level personnel SINAMICS. SINAMICS G converters Safety Integrated for entry level personnel. Hazards in plants and

System Manual 02/2008

Siemens Drives & PLCs Answers for industry.

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Galaxy VM. Battery Breaker Box Installation 09/

SINAMICS. SINAMICS G120 inverters. PM230 Power Modules, IP20 / push-through technology (PT) Hardware Installation Manual

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Installation Instructions Electric Heaters 5 20 kw

Low-Voltage Motors N-compact Standardline Operation on supply system

BA 2039 SIMOGEAR. Adapter for gearbox BA General information and safety notes 1. Technical description. Installing 3.

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SIMOREG CM. Application CM for more than three thyristors in parallel. 6RA70 Series. Microprocessor-Based Converters for Variable-Speed DC Drives

HST-BL-2830MS & HST-BL-2830MS-USA

High Frequency SineWave Guardian TM

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Aurora Wind Interface Box

Belt Scales. Milltronics MWL Weight Lifter. Operating Instructions 11/2011. Milltronics

Belt Scales Accessories. Milltronics Test Chain. Operating Instructions 04/2013. Milltronics

Belt Scales. Milltronics MUS Belt Scale. Operating Instructions 06/2012. Milltronics

SIMOREG SIMOREG DC-MASTER. Converter Commutation Protector. Betriebsanleitung / Operating Instructions. Answers for industry. Edition Ausgabe 07/2013

Hardware Installation Manual

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

MANUAL. Single charger

SINAMICS S120. Chassis Liquid Cooled Power Units. Equipment Manual 01/2011 SINAMICS

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

1PH4 induction motors. Operating instructions 05/2010

BWN, BWT, BNT. Operating Instructions. FLENDER couplings BIPEX. 3400en. Edition 03/2017.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Industrial Controls. Load Feeders. SIRIUS - SIRIUS 3RA Load Feeders. Gerätehandbuch. Siemens Controls 09/2016. Edition. siemens.

SIMOREG DC-MASTER Converter Commutation Protector

FLENDER COUPLINGS SIPEX. Operating Instructions 3800en Edition 10/2017 SNN, SGG, SGG-A, SHH, SKK, SII, SGS, SHH-W

Order No. of the options EMC filter Class A

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Wind Power Inverter WINDY BOY 5000A/6000A

Oil-free piston compressors KK and piston vacuum pumps KV

SIMOREG SIMOREG DC-MASTER. 6RA70 Series

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

Installation Instructions. Y-Series Brushless Servo Motor

Induction motor SIMOTICS M-1PH8

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

D, E, M. Operating Instructions. FLENDER couplings N-EUPEX. 3102en. Edition 03/2017.

Instruction Manual August milltronics MSI BELT SCALE

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Installation Instructions

Installation Instructions

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

%BUB4IFFU. 3-line sine-wave EMC output filters for converters and power electronics SineFormer 520 V AC, A, 40 C. Date: November 2007

RWB, RBS. Operating Instructions. FLENDER couplings RUPEX. 3602en. Edition 03/2017.

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Mini slide EGSC-BS-KF. Operating instructions b [ ]

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

MOTOX input units BA Operating Instructions 05/2010 MOTOX. Answers for industry.

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Operating Instructions Edition 03/2008. Three-phase induction motor AC COMPACT DRIVES Type 1PL628.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Active Interface Module Active Line Module chassis format, air-cooled

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

RWN, RWS, RWB, RBS, RFN, RFS. Operating Instructions. FLENDER couplings RUPEX. 3600en. Edition 03/2017.

Drive System Application

SINAMICS S120 drive system

System Monitoring SCHOOLMETERBOX AU

LV Capacitor CLMD03 Power Module Instruction manual

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

1329I Integrated Drive/Motor CE Filter Option Kit

Exchange of rollers from the XTS-Mover

Operating Instructions Edition 03/2008. Three-phase induction motor AC COMPACT DRIVES Type 1PL622.

Ultrasonic flowmeters. SITRANS F US SONOKIT 2-tracks. Operating instructions 03/2009 SITRANS F. Siemens Controls

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Type NR oil switch installation and operation instructions

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry.

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Galaxy Receiving and Unpacking 09/

Transcription:

SINAMICS G130 Operating Instructions 05/2010 SINAMICS s

Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.3 SP2 05/2010 A5E00409660A

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recoended or approved by Siemens. Proper transport, storage, installation, assembly, coissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E00409660A P 08/2010 Copyright Siemens AG 2010. Technical data subject to change

Table of contents 1 Safety information... 7 1.1 Warnings...7 1.2 Safety and operating instructions...8 2 General... 9 3 Mechanical installation... 13 4 Electrical installation... 17 5 Technical specifications... 19 Operating Instructions, 05/2010, A5E00409660A 5

Table of contents 6 Operating Instructions, 05/2010, A5E00409660A

Safety information 1 1.1 Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions. The successful and safe operation of this device is dependent on correct transport, proper storage and installation, as well as careful operation and maintenance. National safety guidelines must be observed. DANGER Five safety rules When carrying out any kind of work on electrical devices, the "five safety rules" defined in EN 50110 must always be observed: 1. Disconnect the system. 2. Protect against reconnection. 3. Make sure that the equipment is de-energized. 4. Ground and short-circuit. 5. Cover or enclose adjacent components that are still live. NOTICE For a UL-approved system use 60/75 C copper conductors only. Operating Instructions, 05/2010, A5E00409660A 7

Safety information 1.2 Safety and operating instructions 1.2 Safety and operating instructions DANGER This equipment is used in industrial high-voltage installations. During operation, this equipment contains rotating and live, bare parts. For this reason, they could cause severe injury or significant material damage if the required covers are removed, if they are used or operated incorrectly, or have not been properly maintained. When the machines are used in non-industrial areas, the installation location must be protected against unauthorized access (protective fencing, appropriate signs). Prerequisites Those responsible for protecting the plant must ensure the following: The basic planning work for the plant and the transport, assembly, installation, coissioning, maintenance, and repair work is carried out by qualified personnel and/or checked by experts responsible. The operating manual and machine documentation are always available. The technical specifications regarding the applicable installation, connection, environmental, and operating conditions are always observed. The plant-specific assembly and safety guidelines are observed and personal protection equipment is used. Unqualified personnel are forbidden from using these machines and working near them. This operating manual is intended for qualified personnel and only contain information and notes relating to the intended purpose of the machines. The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recoend engaging the support and services of your local Siemens service center for all planning, installation, coissioning and maintenance work. 8 Operating Instructions, 05/2010, A5E00409660A

General 2 Description reduce the voltage load on the motor windings by reducing the voltage gradients at the motor terminals that occur during converter operation. At the same time, the capacitive charge/discharge currents that occur at the converter output when long motor cables are used are reduced. The maximum output frequency when a motor reactor is used is 150 Hz. Note The connecting cables to the Power Module must be kept as short as possible. CAUTION The surface temperature of the motor reactors may exceed 80 C. CAUTION The 100 cooling clearances above and to the side of the components must be observed. CAUTION Provisions for component cooling must be made at the installation site. Power loss data are given in the technical specifications. Operating Instructions, 05/2010, A5E00409660A 9

General Assignment of motor reactor and Power Module Table 2-1 Assignment of motor reactor and Power Module Power Module Unit rating of the Power Module Suitable motor reactor Line voltage 380 480 V 3 AC 6SL3310-1GE32-1AAx 110 6SL3000-2BE32-1AA0 6SL3310-1GE32-6AAx 132 6SL3000-2BE32-6AA0 6SL3310-1GE33-1AAx 160 6SL3000-2BE33-2AA0 6SL3310-1GE33-8AAx 200 6SL3000-2BE33-8AA0 6SL3310-1GE35-0AAx 250 6SL3000-2BE35-0AA0 6SL3310-1GE36-1AAx 315 6SL3000-2AE36-1AA0 6SL3310-1GE37-5AAx 400 6SL3000-2AE38-4AA0 6SL3310-1GE38-4AAx 450 6SL3000-2AE38-4AA0 6SL3310-1GE41-0AAx 560 6SL3000-2AE41-0AA0 Line voltage 500 600 V 3 AC 6SL3310-1GF31-8AAx 110 6SL3000-2AH31-8AA0 6SL3310-1GF32-2AAx 132 6SL3000-2AH32-4AA0 6SL3310-1GF32-6AAx 160 6SL3000-2AH32-6AA0 6SL3310-1GF33-3AAx 200 6SL3000-2AH33-6AA0 6SL3310-1GF34-1AAx 250 6SL3000-2AH34-5AA0 6SL3310-1GF34-7AAx 315 6SL3000-2AH34-7AA0 6SL3310-1GF35-8AAx 400 6SL3000-2AH35-8AA0 6SL3310-1GF37-4AAx 500 6SL3000-2AH38-1AA0 6SL3310-1GF38-1AAx 560 6SL3000-2AH38-1AA0 Line voltage 660 690 V 3 AC 6SL3310-1GH28-5AAx 75 6SL3000-2AH31-0AA0 6SL3310-1GH31-0AAx 90 6SL3000-2AH31-0AA0 6SL3310-1GH31-2AAx 110 6SL3000-2AH31-5AA0 6SL3310-1GH31-5AAx 132 6SL3000-2AH31-5AA0 6SL3310-1GH31-8AAx 160 6SL3000-2AH31-8AA0 6SL3310-1GH32-2AAx 200 6SL3000-2AH32-4AA0 6SL3310-1GH32-6AAx 250 6SL3000-2AH32-6AA0 6SL3310-1GH33-3AAx 315 6SL3000-2AH33-6AA0 6SL3310-1GH34-1AAx 400 6SL3000-2AH34-5AA0 6SL3310-1GH34-7AAx 450 6SL3000-2AH34-7AA0 6SL3310-1GH35-8AAx 560 6SL3000-2AH35-8AA0 6SL3310-1GH37-4AAx 710 6SL3000-2AH38-1AA0 6SL3310-1GH38-1AAx 800 6SL3000-2AH38-1AA0 10 Operating Instructions, 05/2010, A5E00409660A

General Using a motor reactor and dv/dt filter to limit the voltage gradient and transients IGBT converter switching frequencies result in high voltage gradients (dv/dt) at the converter output. If long motor cables are used, this leads to an additional current load on the converter due to capacitive charge/discharge currents. The high voltage gradients, and the resulting transients at the motor terminals, cause the motors' electrical winding load to increase as compared with direct on-line operation. In conjunction with the connected cable capacitances, the motor reactors with their adapted inductances reduce the capacitive charge/discharge currents in the motor cables and, as a function of these motor cables, limit the voltage gradient (dv/dt) and the transients ÛLL at the motor terminals. 6 6 5 5 4 4 3 3 2 2 1 1 0 0 100 200 m 300 0 0 100 200 m 300 Û LL /U N Û LL /U N Û LL /U N Figure 2-1 Using a motor reactor and dv/dt filter to limit the voltage gradient and transients Operating Instructions, 05/2010, A5E00409660A 11

General 12 Operating Instructions, 05/2010, A5E00409660A

Mechanical installation 3 Dimension drawing Figure 3-1 Dimension drawing, motor reactor Operating Instructions, 05/2010, A5E00409660A 13

Mechanical installation Table 3-1 Dimensions of motor reactor, 380 V 480 V 3 AC, part 1 (all specifications in ) 6SL3000-2BE32-1AA0 2BE32-6AA0 2BE33-2AA0 2BE33-8AA0 Connection type Type 1 Type 1 Type 1 Type 1 a2 25 25 25 25 a3 5 5 5 5 a4 12.5 12.5 12.5 12.5 a5 11 11 11 11 I4 300 300 300 300 I5 100 100 100 100 h1 - - - - h2 194 227 194 194 h3 60 60 60 60 h4 285 315 285 285 n1 1) 163 183 163 183 n2 1) 224 224 224 224 n3 257 277 257 277 n4 79 79 79 79 n5 - - - - d3 1) Lengths n1 and n2 correspond to the drill hole spacing Table 3-2 Dimensions of motor reactor, 380 V 480 V 3 AC, part 2 (all specifications in ) 6SL3000-2BE35-0AA0 2AE36-1AA0 2AE38-4AA0 2AE41-0AA0 Connection type Type 2 Type 1 Type 1 Type 1 a2 30 40 40 40 a3 6 8 8 8 a4 15 20 20 20 a5 14 14 14 14 I4 300 410 410 410 I5 100 140 140 140 h1-392 392 392 h2 245 252 252 252 h3 60 120 120 120 h4 365 385 385 385 n1 1) 183 191 191 206 n2 1) 224 316 316 316 n3 277 292 292 302 n4 79 84.5 84.5 79.5 n5-30 30 - d3 1) Lengths n1 and n2 correspond to the drill hole spacing 14 Operating Instructions, 05/2010, A5E00409660A

Mechanical installation Table 3-3 Dimensions of motor reactor, 500 V 600 V 3 AC, part 1 (all specifications in ) 6SL3000-2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 2AH33-6AA0 Connection Type 1 Type 1 Type 1 Type 1 type a2 25 25 25 25 a3 5 5 5 5 a4 12.5 12.5 12.5 12.5 a5 11 11 11 11 I4 300 300 300 300 I5 100 100 100 100 h1 - - - - h2 194 194 194 194 h3 60 60 60 60 h4 285 285 285 285 n1 1) 118 118 118 118 n2 1) 224 224 224 224 n3 212 212 212 212 n4 79 79 79 79 n5 - - - - d3 1) Lengths n1 and n2 correspond to the drill hole spacing Table 3-4 Dimensions of motor reactor, 500 V 600 V 3 AC, part 2 (all specifications in ) 6SL3000-2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Connection Type 1 Type 1 Type 1 Type 1 type a2 30 40 40 40 a3 6 8 8 8 a4 15 20 20 20 a5 14 14 14 14 I4 350 410 410 410 I5 120 140 140 140 h1-392 392 392 h2 235 252 252 252 h3 60 120 120 120 h4 330 385 385 385 n1 1) 138 141 141 183 n2 1) 264 316 316 316 n3 215 292 292 279 n4 63 134.5 134.5 79.5 n5-30 30 - d3 1) Lengths n1 and n2 correspond to the drill hole spacing Operating Instructions, 05/2010, A5E00409660A 15

Mechanical installation Table 3-5 Dimensions of motor reactor, 660 V 690 V 3 AC, part 1 (all specifications in ) 6SL3000-2AH31-0AA0 2AH31-5AA0 2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 Connection type Type 1 Type 1 Type 1 Type 1 Type 1 a2 25 25 25 25 25 a3 5 5 5 5 5 a4 12.5 12.5 12.5 12.5 12.5 a5 11 11 11 11 11 I4 270 270 300 300 300 I5 88 88 100 100 100 h1 - - - - - h2 150 150 194 194 194 h3 60 60 60 60 60 h4 248 248 285 285 285 n1 1) 103 103 118 118 118 n2 1) 200 200 224 224 224 n3 200 200 212 212 212 n4 82 82 79 79 79 n5 - - - - - d3 1) Lengths n1 and n2 correspond to the drill hole spacing Table 3-6 Dimensions of motor reactor, 660 V 690 V 3 AC, part 2 (all specifications in ) 6SL3000-2AH33-6AA0 2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Connection type Type 1 Type 1 Type 1 Type 1 Type 1 a2 25 30 40 40 40 a3 5 6 8 8 8 a4 12.5 15 20 20 20 a5 11 14 14 14 14 I4 300 350 410 410 410 I5 100 120 140 140 140 h1 - - 392 392 392 h2 194 235 252 252 252 h3 60 60 120 120 120 h4 285 330 385 385 385 n1 1) 118 138 141 141 183 n2 1) 224 264 316 316 316 n3 212 215 292 292 279 n4 79 63 134.5 134.5 79.5 n5 - - 30 30 - d3 1) Lengths n1 and n2 correspond to the drill hole spacing 16 Operating Instructions, 05/2010, A5E00409660A

Electrical installation 4 Important safety precautions WARNING The devices are operated with high voltages. All connection procedures must be carried out when the cabinet is de-energized. All work on the device must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account. Work on an open device must be carried out with extreme caution because external supply voltages may be present. The power and control terminals may be live even when the motor is not running. Dangerously high voltage levels are still present in the cabinet up to five minutes after it has been disconnected due to the DC link capacitors on the Power Module. For this reason, the cabinet should not be opened until a reasonable period of time has elapsed. The operator is responsible for ensuring that the motor reactor and other components are installed and connected in accordance with the recognized technical rules in the country of installation and applicable regional guidelines. Special attention should be paid to cable dimensioning, fuses, grounding, shutdown, disconnection, and overcurrent protection. If an item of protective gear trips in a branch circuit, a leakage current may have been disconnected. To reduce the risk of fire or an electric shock, the current-conducting parts and other components in the built-in unit should be inspected and damaged parts replaced. When an item of protective gear trips, the cause of the trip must be identified and rectified. Operating Instructions, 05/2010, A5E00409660A 17

Electrical installation Connection When connecting the motor reactor, you must take into account the following conditions to ensure that it functions correctly: With analog control cables, connecting the shield at both ends can result in coupled-in noise. To prevent this, the shield must only be connected at one end on the Power Module. Control cables must be routed separately from power cables. Power cables are motor cables or connecting cables from the DC link of the Power Module (terminals DCPA/DCNA) to other components (e.g., Braking Module). In particular, you must ensure that control cables and power cables are not routed in parallel in a joint cable raceway, even if all the cables are shielded. You must use shielded motor cables. The shield for the motor cable must be attached to the shield plate and motor housing. The ground wire for the motor must be fed directly back to the Power Module. Connection overview U1 V1 W1 PE1 U2 V2 W2 PE2 1U1 1V1 1W1 1U2 1V2 1W2 V W U PE M ~ Figure 4-1 Connecting the motor reactor and Power Module 18 Operating Instructions, 05/2010, A5E00409660A

Technical specifications 5 General technical specifications Table 5-1 General technical specifications Output frequency 0... 150 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation Ambient temperature -25... +70 C -25... +70 C 0... +50 C Relative humidity (noncondensing), corresponds to class: 5... 95 % 1K4 to EN 60721-3-1 5... 95% at 40 C 2K3 to EN 60721-3-2 5... 95 % 3K3 to EN 60721-3-3 Mechanical stability Storage Transport Operation Vibrational load: - Displacement - Acceleration 1.5 at 5... 9 Hz 5 m/s² at >9... 200 Hz 3.5 at 5... 9 Hz 10 m/s² at >9... 200 Hz 0.075 at 10... 58 Hz 10 m/s² at >58... 200 Hz Shock load: - Acceleration 40 m/s² at 22 ms 100 m/s² at 11 ms 100 m/s² at 11 ms Detailed technical specifications Table 5-2 Technical specifications of motor reactors 380 V 480 V 3 AC, part 1 Order number 6SL3000-2BE32-1AA0 2BE32-6AA0 2BE33-2AA0 2BE33-8AA0 Suitable for Power Module 6SL3310-1GE32-1AAx 1GE32-6AAx 1GE33-1AAx 1GE33-8AAx Rated current A 210 260 310 380 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor m 0.436 0.486 0.454 0.5 300 (shielded) 450 (unshielded) Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 300 285 257 Weight kg 66 66 66 73 300 315 277 0.422 0.47 300 285 257 0.448 0.5 300 285 277 Operating Instructions, 05/2010, A5E00409660A 19

Technical specifications Table 5-3 Technical specifications of motor reactors 380 V 480 V 3 AC, part 2 Order number 6SL3000-2BE35-0AA0 2AE36-1AA0 2AE38-4AA0 2AE38-4AA0 Suitable for Power Module 6SL3310-1GE35-0AAx 1GE36-1AAx 1GE37-5AAx 1GE38-4AAx Rated current A 490 605 840 840 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor m 0.448 0.5 0.798 0.9 300 (shielded) 450 (unshielded) Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 300 365 277 Weight kg 100 130 140 140 410 392 292 0.75 0.84 410 392 292 0.834 0.943 410 392 292 Table 5-4 Technical specifications of motor reactors 380 V 480 V 3 AC, part 3 Order number 6SL3000-2AE41-0AA0 Suitable for Power Module 6SL3310-1GE41-0AAx Rated current A 985 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor Degree of protection Dimensions Width Height Depth m 0.939 1.062 IP00 410 392 302 Weight kg 146 300 (shielded) 450 (unshielded) 20 Operating Instructions, 05/2010, A5E00409660A

Technical specifications Table 5-5 Technical specifications of motor reactors 500 V 600 V 3 AC, part 1 Order number 6SL3000-2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 2AH33-6AA0 Suitable for Power Module 6SL3310-1GF31-8AAx 1GF32-2AAx 1GF32-6AAx 1GF33-3AAx Rated current A 175 215 260 330 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor m 0.357 0.403 M6 0.376 0.425 M6 300 (shielded) 450 (unshielded) 0.389 0.441 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 300 285 212 Weight kg 34 34 40 46 300 285 212 M6 300 285 212 0.4 0.454 M6 300 285 212 Table 5-6 Technical specifications of motor reactors 500 V 600 V 3 AC, part 2 Order number 6SL3000-2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Suitable for Power Module 6SL3310-1GF34-1AA0x 1GF34-7AAx 1GF35-8AAx 1GF37-4AAx Rated current A 410 465 575 810 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor m 0.481 0.545 0.631 0.723 300 (shielded) 450 (unshielded) 0.705 0.801 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 350 330 215 Weight kg 68 80 80 146 410 392 292 410 392 292 0.79 0.91 410 392 279 Operating Instructions, 05/2010, A5E00409660A 21

Technical specifications Table 5-7 Technical specifications of motor reactors 500 V 600 V 3 AC, part 3 Order number 6SL3000-2AH38-1AA0 Suitable for Power Module 6SL3310-1GF38-1AAx Rated current A 810 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor Degree of protection Dimensions Width Height Depth m 0.877 1.003 IP00 410 392 279 Weight kg 146 300 (shielded) 450 (unshielded) Table 5-8 Technical specifications of motor reactors 660 V 690 V 3 AC, part 1 Order number 6SL3000-2AH31-0AA0 2AH31-0AA0 2AH31-5AA0 2AH31-5AA0 Suitable for Power Module 6SL3310-1GH28-5AAx 1GH31-0AAx 1GH31-2AAx 1GH31-5AAx Rated current A 100 100 150 150 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor 0.26 0.3 0.26 0.332 m M6 M6 300 (shielded) 450 (unshielded) Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 270 248 200 Weight kg 25 25 25.8 25.8 270 248 200 M6 270 248 200 M6 270 248 200 22 Operating Instructions, 05/2010, A5E00409660A

Technical specifications Table 5-9 Technical specifications of motor reactors 660 V 690 V 3 AC, part 2 Order number 6SL3000-2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 2AH33-6AA0 Suitable for Power Module 6SL3310-1GH31-8AAx 1GH32-2AAx 1GH32-6AAx 1GH33-3AAx Rated current A 175 215 260 330 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor 0.403 0.425 0.441 0.454 m M6 M6 300 (shielded) 450 (unshielded) Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 300 285 212 Weight kg 34 34 40 46 300 285 212 M6 300 285 212 M6 300 285 212 Table 5-10 Technical specifications of motor reactors 660 V 690 V 3 AC, part 3 Order number 6SL3000-2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Suitable for Power Module 6SL3310-1GH34-1AAx 1GH34-7AAx 1GH35-8AAx 1GH37-4AAx Rated current A 410 465 575 810 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor 0.545 m 0.631 0.723 300 (shielded) 450 (unshielded) 0.705 0.801 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 350 330 215 Weight kg 68 80 80 146 410 392 292 410 392 292 0.78 0.91 410 392 279 Operating Instructions, 05/2010, A5E00409660A 23

Technical specifications Table 5-11 Technical specifications of motor reactors 660 V 690 V 3 AC, part 4 Order number 6SL3000-2AH38-1AA0 Suitable for Power Module 6SL3310-1GH38-1AAx Rated current A 810 Power loss - at 50 Hz - at 150 Hz Connections - to the Power Module - load - PE Max. permissible cable length between motor reactor and motor Degree of protection Dimensions Width Height Depth m 0.877 1.003 IP00 410 392 279 Weight kg 146 300 (shielded) 450 (unshielded) 24 Operating Instructions, 05/2010, A5E00409660A

Siemens AG Industry Sector Drive Technologies Large Drives Postfach 4743 90025 NUREMBERG GERMANY www.siemens.com/automation Subject to change Siemens AG 2010