INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

Similar documents
INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

TNT SERIES WATER CONDITIONERS

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

Fleck Fiberglass Section 9 Chloride Dealkalizers

PRESSURE GAGES AND TEST TAPS

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

Fleck Top Mount Section 1 Fiberglass Softeners

Fleck Epoxy Lined Section 2 Steel Softeners

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

Commercial Softeners

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

AquaMatic Series. A100 and A200 Stager Controls

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

Control Valves, Fittings and Accessories

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

Control Valves, Fittings and Accessories

BNT 85 /185 Valve Operation Manual

HYDRO ION Water softener Type: VAD CS

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Installation and Operations Manual

Signature Series. Duplex Softener Service Manual

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

COMMERCIAL CONTROL VALVES. Magnum Control Valve

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

HIGH VOLTAGE HP Water Cooled Dynamometer Calibrated Load Cell, Precision Control and Instrument Package

INSTALLATION, OPERATING AND SERVICE MANUAL

Assembled Engineered Systems. Softeners Filters Specialty Systems

IWT 565 Series Valve Operation Manual

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

DCS7 Water Softener - Product Manual

Integrated Vector-Type Pump Drive Product Group D and W

P/N: (Rev. G 1/19/10)

CLEAVER-BROOKS. SAB/Q Heavy Duty Co-Current Commercial and Industrial Water Softeners

All Greenerd Presses are designed and built to ANSI B (R-2000) compliance. 4-POST HYDRAULIC DEEP DRAW PRESS

2inch Valve S D S D

65 Series. Valve Operation Manual

Dry Chemical Feed Systems

Model 5000 Level Controller

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

COMMERCIAL UST ADD WATER BULLETIN; ISSUE 1

Owner s Manual AMERICAN AQUA Saline, MI (734) Howell, MI (517) Adrian, MI (517)

Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48

EPDM,(Options for Buna, Viton - Depending on Process) B-7 All Thread w/ Stainless Sleeve

HIGH POWER SOLENOID DRIVER 1

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

ROGERS MACHINERY COMPANY, INC

ANSI DIME. Engineered for EXTREME Reliability in Chemical Processes

AquaMatic Control Valves, Stagers and Controllers

Performance Specifications

ROGERS MACHINERY COMPANY, INC

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Series 774 Automatic Skid Package

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

Owner s Manual. H151 HE - High Efficiency Water Softening System

RAPIDMIX 400CW. Length of Machine (19.5m) Length when erected Width of Machine 9-10 (3.00 m) Width Same

H-125 HE SERIES. Owner s Manual HIGH EFFICIENCY SYSTEM. Manufactured by: HELLENBRAND, INC. Web:

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

EZ SERIES BOOSTER PUMPS

earth safe Fuel Systems for Critical Power

6700XTR Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

2014 Auxiliary Catalog. Controllers Packages Systems Accessories. 37 Forestwood Dr., Romeoville, IL

BUILT SMART, CLEANS TOUGH!

Excellence through Versatility

Owner s Manual HELLENBRAND, INC.

3200NT Timer Service Manual

Zone Valves and Parts (Honeywell)

UNLEASH THE POWER REAL-WORLD SOLUTIONS

MARFAID Solenoid Valves

2017 CATALOG East Main Street Mesa, AZ

Auxiliary Equipment. Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B

SECTION H4 BOILERMATE DEAERATORS

FLECK 5600 SERVICE MANUAL. waterpurification.pentair.com

Reverse Osmosis (RO) Water Treatment Systems

Fold-Gluing. The high-performance system for longitudinal gluing and fold-softening. Precise, reliable, fast and effective

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Owner s Manual. Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin

Installation and Operation Manual

Increase Turbine Output. Gas Turbine Inlet Cooling

Sullair: An Industry Leader

FreezeFree TM Nitro Anti-Icing System GENERAL SPECIFICATIONS

VALVE. Water Treatment Controls ~~~~ SERVICEMANUAL ----

W-200-IS Specifications

FLECK 5600SXT DOWNFLOW

Salt Brine De-Icing & Dust Control Systems

Model 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

wd-2

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

+GF+ PNEUMATIC ACTUATED BALL VALVE +GF+ PNEUMATIC ACTUATED BALL VALVE +GF+ PNEUMATIC ACTUATED BALL VALVE 3-16

Transcription:

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES 150,000 TO 1,100,000 GRAINS CAPACITY (Single, Twin, Triple or Quadruple Demand Systems Available) 1 P age

Industrial Performance and Proven Reliability FRP/Composite Pressure Vessel (Non-code & ASME) - Industrial grade polyester/composite construction provides outstanding durability and higher corrosion resistance than carbon steel vessels (Chemical resistant Vinyl ester resins are available). Fiberglass vessel weights are about 1/3 less than steel tank vessels and cost less. Lakeside Provides Resins that are manufactured using full 8 % DVB. This process provides high chemical and physical stability, lower pressure drop and greater resistance to bead breakage. Lakeside resins are shipped in the sodium form providing immediate soft water for your customer. High tolerance resins are available for chlorine, high temperature, increased flow rates or lower hardness leakage applications. Underdrain - The radial hub underdrain construction uses high quality schedule 80 PVC pipe and fittings, delivering high performance standards. The.010 PVC slotted laterals provide high flow rates and reliable service. Lakeside also features a standard hide-out preventer in all vessels to reduce hardness leakage when dilute brine is not rinsed out in the bottom of the vessel during the regeneration process. Boiler applications that have very critical water quality requirements often request this feature on custom products. Brine Maker The non-toxic polyethylene rotationally molded brine tank provides the ultimate corrosion resistance and superior strength. Our standard grid plate and special brine valve maintain precise brine saturation for optimum ion exchange. The brine valve is designed with four internal primary checks delivering proven and reliable industrial performance. Thermoplastic Y-pattern diaphragm valve nest design allows each valve to be exactly designed and sized for the required function, providing the most cost effective, efficient and serviceable corrosion proof system in the market. 2 P age

Brine Eductors are constructed of PVC and deliver the correct brine concentration to the softener resin. These hydraulic eductors are pressure compensating and produce 8-12% brine concentration to the softener bed for proper Ion exchange. Flow Sensors are designed to interface with the controllers. The meter sends a pulse signal to the controller that converts into gallons. The correctly programmed K-Factor will ensure the correct batch count and deliver continuous soft water 24/7. The Standard Lakeside 2001 Programmable Microprocessor automatically controls the regeneration cycles by utilizing a pilot valve to operate the diaphragm valves. These valves can be hydraulically or pneumatically operated for your operational requirements. The 2001 microprocessor also features a pre-rinse cycle to prevent hardness leakage at the beginning of the service run on twin alternating systems. Boiler applications typically have very critical water quality requirements and often request this feature. The Optional Pentair 3214 Programmable Microprocessor provides single, twin, triple or quadruple system capabilities. The controller features twin alternating, progressive demand or parallel application options. Multiple tank applications, progressive demand and the diagnostic capabilities are premiere features of this controller. The progressive demand application allows one to four softeners to be online in proportion to the service demand. One softener is always in service, and the other units automatically come online as the flow increases. As the flow rate decreases, softeners will be removed from service based on the pre-programmed GPM settings. This feature provides uninterrupted flow of soft water 24/7 during variable and peak flows. (One auxiliary output is provided to start a chemical feeder, pump or motor application) 3 P age

Optional Allen Bradley PLC control packages come standard with the HMI EZ Touch color screen which has extremely user friendly programming. Lakeside PLC solenoid system features a hold, advance, resume, termination or close of all valves function, for fast, easy field service. The main screen can be designed to display a variety of parameters such as current flow rates, online tank status and remaining gallons of each vessel. Custom programming available. The AB 10/100 IP Ethernet Network Connection port is standard for building management capabilities. Custom programming and alternate communication protocols are available. Operating Parameters: Pressure 30-100psi. Temperature range 35F-100F Electrical: 120vac-60Hz Electrical enclosures rated NEMA 12/4X Drain piping limits: Max. 10ft. vertical discharged to an atmospheric floor drain sized to handle the backwash rate of the system. (Max proven length is 25ft). OPTIONS AVAILABLE: Skid mounted, pre-piped, pre-wired for faster and cost effective installations ASME code vessels are available 18 63 Low flow recirculation systems to prevent channeling during low service flow periods Hard water by-pass (single units) Brine Reclamation systems can save up to 25% on salt usage Pumped brine and dilution stations are available for pit or silo applications Pre-engineered systems and custom engineered systems are available 4 P age

Model LWTSF Capacity max. (Grains) Capacity min. (Grains) Qty. resin CU. FT. Cont. GPM PSI-D Peak GPM PSI-D Mineral Tank size (Inches) In / Out pipe size BWF Rate GPM Brine maker size (Inches) Salt storage Cap. (LBS) Salt dosage max. (LBS) Salt dosage Min. (LBS.) 90-2 90,000 60,000 3 31 15 45 25 14 X 65 2 5.0 24X41 450 45 18 120-2 120,000 80,000 4 39 15 59 25 16 X 65 2 6.0 24 X 41 450 60 24 150-2 150,000 100,000 5 48 15 81 25 18 X 65 2 8.0 24 X 41 450 75 30 210-2 210,000 140,000 7 56 15 76 25 21 X 62 2 10.0 24 X 54 610 105 42 210-3 210,000 140,000 7 70 15 84 25 21 X 62 3 10.0 24 X 54 610 105 42 300-2 300,000 200,000 10 80 15 112 25 24 X 72 2 15.0 30X 48 850 150 60 300-3 300,000 200,000 10 150 15 260 25 24 X 72 3 15.0 30 X 48 850 150 60 450-2 450,000 300,000 15 90 15 118 25 30 X 72 2 20.0 30 x60 950 225 90 450-3 450,000 300,000 15 165 15 215 25 30 X 72 3 20.0 30 X60 950 225 90 600-2 600,000 400,000 20 90 15 120 25 36 X 72 2 30.0 39 X 48 1250 300 120 600-3 600,000 400,000 20 210 15 255 25 36 X 72 3 30.0 39 X 48 1250 300 120 750-2 750,000 500,000 25 94 15 126 25 42 X 72 2 45.0 39 X 60 1630 375 150 750-3 750,000 500,000 25 185 15 245 25 42 X 72 3 45.0 39 X 60 1630 375 150 1,100-2 1,100,000 740,000 37 105 15 130 25 48 X 72 2 55.0 50 X 60 2,200 555 222 1,100-3 1,100,000 740,000 37 217 15 275 25 48 X 72 3 55.0 50 X 60 2,200 555 222 5 P age

LWTSF INDUSTRIAL WATER SOFTENERS 6 P age

Water Softener Dimensions MODEL NO. RESIN TANK BRINE TANK OAH WIDTH Overall Length Including Brine Tank SINGLE TWIN TRIPLE LWTSF-90 14" X 65" 24" X 41" 87 26 68 99 122 LWTSF-120 16" X 65" 24" X 41" 88 28 68 99 128 LWTSF-150 18" X 65" 24" X 41" 93 30 68 99 132 LWTSF-210 21" X 62" 24" X 54" 93 34 71 107 143 LWTSF-300 24" X 72" 30" X 48" 100 37 79 118 157 LWTSF-450 30" X 72" 30" X 60" 101 42 73 115 157 LWTSF-600 36" X 72" 39" X 48" 102 48 88 136 184 LWTSF-750 42" X 72" 39" X 60" 102 54 98 152 206 LWTSF-1100 48" X 72" 50" X 60" 105 60 113 173 233 Overall length including brine tank Dimensions are approximate. Add 6 for skid mounted. OAL includes 12-15 clearance between tanks. Clearance above tanks required to load resin. ASME tanks require additional height. 7 P age