Turbidity and Suspended Solids Transmitter

Similar documents
MagFlux Q 8200 Series

NEW. Level Transmitter 2.1. Data sheet

Royce Total Suspended Solids Systems. Water & Wastewater

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

mass flowmeter for compressed air

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UTM10 Series Ultrasonic Transit-time Flowmeters

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Flow meter Type Recordall (RCDL)

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

QUANTUM LX CONTROL PANEL

Flow VA 550 / 570. DVGW tested. Flow.

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

DISSOLVED OXYGEN MEASUREMENT

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Superstatic 440. Static Heat- and Cooling Meter. Application

Cerlic CBX Sludge blanket tracker

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

The right choice for your application. Pressure sensors from ifm.

INTECH Micro 2300-RTD6

Marsh McBirney Flo-Dar

Appendix. Clearance. Skewed profiles. Application Schematics

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

USERS MANUAL MCD REMOTE OPERATOR

Level and Flow Measurement. Sludge Finder 2

Flash Point Process Analyzer

Suppression Technology Valve Suppressors - special function

Hydrovar and Packaged Hydrovar

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Metal tube variable area flowmeter for gases, liquids and steam

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Pressure Transmitter

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Marine Shaft Power Meter Product Overview

List of Contents. Agrimag User Guide 1 V V

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

MULTICAL 6M2. Data sheet

Gladiator. Acoustic Switch & Auto Spray Cleaner. Data Sheet. A Higher Level of Performance. Non-contact Self Cleaning Blocked Chute Detection

Time Delta S Fixed Transit-Time Flow Meter System

Wind display type WSDI-2 DATA SHEET

Level Measurement Point level measurement - RF Capacitance switches

Electromagnetic Flowmeters. Product Overview.

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Ultrasonic Sludge Blanket Monitoring System

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Oxiperm 164 D for 30 to 2000 g/h

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

to mv Redox measurement accuracy. 173 x 195 x 103mm / 1.5kg Display

INSTRUMENTATION & CONTROL

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Weighing Products & Process Control Systems. Load Cells & Mounting Kits. Safety Critical Systems. Nuclear Build Load Cells. Custom Built Load Cells

Oxiperm 164 C for 150 to 2500 g/h

Level Measurement Continuous level measurement - Radar transmitters

Ultrasonic Sludge Blanket Monitoring System

Model Q45H/ Residual Chlorine Monitor...

SonoMeter 30 Energy Meters

SS Concentration Analyzer

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

flow x3 flow monitoring

ExBin-P Pressure switches 5 Pa Pa

Digital ph transmitter

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

MAIN FUNCTION FEATURES. . D = v t /2

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Model TUR-200D Turbine Flowmeter

MODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)

Range of Ultrasonic Flowmeters.

Positive displacement batch controller

MME/MOE Intelligent Electric Actuators About Ontrac

Flow switches Series AD/VH

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

SonoMeter 30 Energy Meters

Point level measurement Capacitance switches

F-2600 SERIES INLINE VORTEX FLOW METER

Optidew Vision Optical Dew-Point Meter

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Signet Pressure Transmitter

Pressure Transmitters

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Transcription:

Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

General MJK SuSix turbidity and suspended solids sensors are designed for measurement by immersing the sensor into open tanks, wells and containers or in-line pipe mounting. The SuSix transmitter is rugged and designed to handle tough applications. The scratch-proof saphire optics, the PUR cable and the heavy duty sensor housing ensure long life, even where scaling and biofouling are problems. Applications Sewage and wastewater plants Drinking water Biologic control Sludge treatment Filtering stations Groundwater pump stations Application examples for measuring with SuSix on a wastewater plant. Inlet Preclarifier Aeration basin Clarifier Effluent outlet Return to inlet Dewatering process Sludge digestion tank Sludge thickner One Sensor - Full Range The sensor provides a full range from 0.001 to 9999 FNU/NTU for turbidity and 0.001 to 400 g/l (SiO 2 ) for suspended solids measurements. The turbidity measurement complies with ISO 7027. The SuSix is equipped with beam forming optics for multi-angle detection of turbidity and suspended solids. This advanced optical system is combined with a progressive algorithm using neural logic to generate a reliable high quality measurement. The sensor compensates for errors due to fouling or aging of the optical array and compensates for gas bubbles in the sample. Calibration The SuSix sensor is provided with factory calibration for turbidity, and zero point factory calibration for suspended solids. A single point in-situ calibration can be conducted for many applications. For more rigorous or difficult applications a two- or three-point calibration is also possible. 2

High Quality Materials The SuSix sensor is constructed of stainless steel with chromium-dioxide coating and scratch resistant sapphire lenses in a highly polished stainless steel sensor face. An optional self-cleaning wiper system is available for particularly dirty and difficult applications. Flexible Installation MJK s modular design allows up to 300 meters (950ft.) between the sensor and the converter, and the Display Unit can be mounted up to 1000 m (3000 ft.) from the signal converter with ordinary twisted wires. One Display Unit can control up to four Mag- Flux converters and/or SuSix signal converters for greater economy, space savings and an improved overview of the multiple measurement values. 1 pc. SuSix with display (206305) ll RS- 485 3 pcs. SuSix without display (206308) ll RS- 485 ll RS- 485 Simple to Operate The SuSix Display Unit has a mobile phone-like menu structure and can display text in several selectable languages. 4 pcs. SuSix sensors (206310 or 206312) Max 1000 m PC Connection SuSix allows downloading setup configurations, uploading new instrument software updates and display customization. The onboard data logger captures 20.000 readings which are displayed as an electronic graph and can be retrieved as a CSV file on a PC. This connectivity is achieved with a common USB port and the free MJK Field Link software. Flexible In- and Outputs The SuSix converter has one 4-20 ma analogue output, two digital outputs for alarms or control, and one digital input for resetting alarms, batches, etc. User-definable Text Up to five lines of text and readings can be configured by the user. The graphic display is automatically adjusted to show the largest characters possible. Alarms can be displayed as pop-up alarms until they are reset. Modbus Communication The Display Unit uses the Modbus RTU communication protocol to connect to the SuSix Converter. The converter can in turn connect to SCADA systems with its Modbus communication protocol. Register lists are available upon request by our customers. 3

Specifications Converter and Display Unit Converter Accuracy Measuring input RS 485 +/- 0,1% of reading Analog output One active 4-20 ma, galvanically isolated (max. load 800 W) Digital outputs One voltage-free electromechanical relay (max. 50 V DC / 1 A) One optically isolated MOSFET relay (max. 50 VAC / V DC / 120 ma) Digital inputs One, max. 30 V DC, < 5 V DC = 0 (low), > 10 V DC = 1 (high), pulse length > 100 ms Communication MODBUS RTU-mode, 9600 baud, 2-wire RS 485, slave-mode Interface Power supply Cabinet material Enclosure rating IP 67, NEMA 6 Temperature range - 20 60 C Weight RS 485 for connection to Display Unit or PLC 24 V AC, 50 / 60 Hz ± 10 % or 115 V AC, 50 / 60 Hz ± 10 % or 230 V AC, 50 / 60 Hz ± 10 % Power consumption max. 10 W Polycarbonate, glass reinforced 1,1 kg CE approvals EN 61000-6-4:2001, EN 61000-6-2:2001 Display Unit Enclosure rating Dust and waterproof IP 67, NEMA 6 (when mounted on Converter) Housing material Polycarbonate, glass reinforced Protection lid Transparent polycarbonate Display White backlit LCD-display (64 x 128 pixels) with softkeys Indication Indication measurement, configuration and graph Clock Real-time clock with built-in battery backup Communication MODBUS RTU-mode, 9600 baud, 2-wire RS 485, master-mode Interface RS 485 Memory 256 Kb Flash memory, 20.000 entries with date, time and value Interface USB 1,1 type mini B, Female Temperature range - 20 60 C Electrical Connections on the Converter Pink Grey Brown White Shield +DC GND A Connection for SuSix Sensor B GND Line 4

Specifications Sensor SuSix Sensor Turbidity 0.001-9999 FNU/NTU 1) Suspended solids 0.001-400 g/l (SiO 2 ) Measurement principle Infrared-diode system and beam focusing (l = 860 nm) Turbidity Two-channel-90 scattered light measuring corresponding to DIN/EN 27027/ ISO7027 Additional verification by six-channel multi-angle measuring Suspended solids Six-channel, multi-angle with modified absorption 2 channels are used for absorption Materials Head: Stainless steel DIN 1.4460 Body: Stainless steel DIN 1.4435 Optical lenses: Sapphire O-ring: Viton Wiper (optional): PA (GF), TPU Cable: PUR Cable 3 x 2 x 0.34 mm 2, outer diameter Ø 8.3 mm Cable length 10 m (customized lengths, optional 2 ) Response time Flow velocity Power supply Current consumption Output Accuracy (turbidity) Accuracy (susp. solids) 1 second No limit 24 V DC (15-30 V DC) Approx. 45 ma RS 485, 9600 baud, 2-wire Better than 3% of actual concentration Better than 5% of actual concentration (depends on calibration and media) Temperature range 0-60 ºC short term to 80 ºC with wiper 0 to 50 ºC Enclosure rating Weight IP 68 to IEC 529 (10 m) / 10 bar pipe mounted, NEMA 6x 1,3 kg Approvals CE: EN61010-1, EN61326-1 ATEX: Ex II 3G 1) 4000 upwards FNU internal manufacturer norm. 2 ) Can be delivered with other cable lengths on request. Mechanical Dimensions Immersion Fitting SuSix Immersion fitting order no. 155215 Sensor Wall bracket for extension Extension for universal bracket 1 ISO RG 240 mm 40 mm Universal bracket 1000 mm 475 mm SuSix sensor T Insertion Fitting Ø49 mm 380 mm SuSix sensor SuSix insertion fitting order no. 155210 Measure position Two positions Service position 5

+DC GND A B Max. four MJK converters with Modbus can be connected to one : Converter #1 Converter #4 Display unit 2 wire 4 wire + A B - + - C NO C1 N01 C2 N02 PE N L -Display- -ma- -DI- -D01- -D02- Mains supply + A B - + - C NO C1 N01 C2 N02 PE N L -Display- -ma- -DI- -D01- -D02- Mains supply +DC GND A B Max. four MJK converters with Modbus can be connected to one : Converter #1 Converter #4 Display unit 2 wire 4 wire Data Sheet Mechanical Dimensions 162 156 186 89 183 85 Converter and Display Unit 83 79 150 144 M20 Order Numbers SuSix Converter, Displays, Sensors and Accessories Pink Grey Pink Grey 521269 Brown Shield 521269 Brown Shield Line 521268 Line Fuse 24V AC: 500mA T Fuse 115V AC: 125mA T Fuse 230V AC: 63mA T Fuse 24V AC: 500mA T Fuse 115V AC: 125mA T Fuse 230V AC: 63mA T 521268 206305, SuSix Converter with display 207930, Wall Mounting Kit 207935, Panel Mounting Bracket Converter mounted in a panel SuSix Converters 206304 SuSix Converter w/ display, 10-30 V DC 206305 SuSix Converter w/ display, 115 / 230 V AC 206306 SuSix Converter w/ display, 24 V AC 206307 SuSix Converter without display, 10-30 V DC 206308 SuSix Converter without display, 115 / 230 V AC 206309 SuSix Converter without display, 24 VA C 207930 Wall mounting kit / Junction box for sensor cable 207935 Panel mounting bracket SuSix Sensors 206310 SuSix Sensor 206312 SuSix Sensor w/ wiper Accessories for SuSix Sensors 206350 Wiper kit (5 pcs.) 206355 Wiper repair kit 206360 Gasket pulling/insertion tool 691120 Cable for SuSix sensor (PUR) Fittings for SuSix Sensors 155210 SuSix Insertion fitting 155215 SuSix Immersion fitting Accessories for SuSix Sensor Fittings 200205 Universal bracket 200210 Wall bracket for extension 200215 Extension for universal bracket Distributed by: MJK offices Denmark www.mjk.dk mjk@mjk.dk +45 45 56 06 56 Norway www.mjk.no mjk@mjk.no +47 69 20 60 70 The Netherlands North America mjknl@mjk.com DK: +45 45 mjkusa@mjk.com 56 06 56 +31 251 672171 NO: +47 69 +1 20 847 60 482 70 8655 Sweden Australia www.mjk.se kontoret@mjk.se mjk@mjk.com +46 53 31 77 50 +61 3 9758 8533