ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Similar documents
Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

EPS/ELA-Series User Manual EPS/ELA 250W

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES

DC POWER SUPPLY ALIMENTATION C.C.

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

DC REGULATED POWER SUPPLY

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

DC REGULATED POWER SUPPLY

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

3000 Series Operation Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Powerful Solutions DHP - Introduction

Low and High Voltage Power Supplies

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Switching DC Power Supply

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

SECTION DC POWER SUPPLY/BATTERY CHARGER

KEPCO Will Point You In The Right Direction!

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

DC POWER SUPPLY (Switching mode)

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Phoenix Inverter

B BASIC HEAT TREATMENT CONSOLE

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Low Profile DC Power Supply with Zero Voltage Soft Switching

TECHNICAL DESCRIPTION

Switching Power Supply

BLU SERIES Battery Load Units

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

VSD Series II Variable Speed Micro Drives

LV Capacitor Bank APC

INSTRUCTION MANUAL Model 1743B

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

PRODUCTS: POWER SUPPLY

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Technical Specification SENTINEL PRO

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Triple Output Power Supply

SST-ST75F-ESS The essential silver standard

LV Capacitor Bank APC

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

DC POWER SUPPLY SYSTEMS

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Industrial Chargers and

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Emergency lighting units EM powerled

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Induction Power Supplies

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

1 Phase electronic contactor (SC 1)

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

MCD 200 Series Soft Starters

TECHNICAL DATA SHEET KVA UPS Systemss

SINAMICS GM150 IGCT version

Z+ Series. 200W, 400W, 600W and 800W Programmable DC Power Supplies. Z+ Series 1. Model Selector. Minimises system rack height

Panel Model Adjust Adjust Power 5Hz-1MHz 20MHz BW 5Hz-1MHz % Output Jacks Range Range (W) (mv) (mv) (ma) ( VAC) (Option)

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

ELECTRICAL PANELS. Chap.

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

MJÖLNER 200 Microhmmeter

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Electronic Ballast EVG 2000-T

Industrial Power Supplies

Power Switching Devices

BC-2014 ULTRA COMPACT 4-BAY SMART BATTERY CHARGER (Military Grade)

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

AC/DC Converter MBP250-2A13D13M

Open Frame Power Supplies

J1000. Compact Inverter Series.

SSW07. Soft Starters. Applications. Standard Features

BLU SERIES Battery Load Units

Technical Data Sheets

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

EM DC Multi-Function DC Energy Meter

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Switching Power Supplies

Transcription:

$ PROGRAMMABLE POWER SUPPLY EAN CODE : 3760244880062 1 output Powerfull POWERFUL ALR3220 VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS232, RS485 & 0-10V isolated LabVIEW as a standard PERFORMANCE : output in the rear-panel,used for remote-sensing FUNCTIONS : square, positive and negative ramp, rise or fall time ELEGANT : New design and feathery SPACE-SAVING : vertical & COMPACT BOX / 640W PRACTICAL : Lightweight with built-in handle and cord storage area. QUIET : Silent temperature-controlled fan cooling. LOCKING : configuration & stand-by 640 WATTS 0-32V 0-20A LabVIEW ULTRA-COMPACT!!! C!@!! C Voltage Floating outputs : on 4mm safety terminals in the front-panel, and on screw terminal block for 2.5mm² on the rear-panel. Automatic constant voltage operation. Adjustable from 0 to 32.00 Volts (0 to ±10mV) ; resolution : 10mV. Setting accuracy : < 0,03% that to say ±10 mv. Regulation : < 50mV for a load change from 10 to 90%. < 1mV for a ±10% line change. Ripple : < 1mV rms including : < 3 mv peak to peak of noise (BP 20 MHz) < 15mV peak to peak of switching spikes Internal resistance : < 4mΩ. Display : 4 digits on graphic LCD. Accuracy measurement : < 0,03% that to say ±10 mv. Automatic constant current operation. Adjustable from 0 to 20.00 Amps ; resolution : 10mA. Setting accuracy : < 0,05% that to say ±10 ma. Regulation : < 10mA for a load charge from 10 to 90%. < 1mA for a ±10% line charge. Ondulation : < 6mA peak to peak or 2mA rms. Display : 4 digits on graphic LCD. Accuracy measurement : < 0,05% that to say ±10 ma. s Against short-circuits, by current regulation. Against overtemperature by fan and thermal circuit-breaker. Against overcurrent on main input, by internal fuses. Various and functions Dispaly : Graphic LCD 128 x 64 pixels with white backlight. Visualization of all parameters CV (Constant Voltage) mode or CC (Constant ) Memories : 16 including 15 configurable. OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi. Functions : 6 available on U or I (Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot). Time adjustement from 10ms to 60mn. Remote sensing : automatic function on the front side output. 4 wires mode on the back-side's terminal blocks. Correction of the voltage drop in the wires : 2V Standby : output, enable / disabled and standby of the power supply. Interfaces All the interfaces are insulated of the output (150V max). USB, RS232 and RS485 as a standard. LabVIEW's drivers as a standard. Controller 0 10V : for U and I by direct input 0-10V or potentiometer 10K or adjustable resistance 10K. In the back side on disconnect scribe terminal blocks. : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, CAT II. CEM : Complies with EN 61326-1 and EN 55011. Input voltage : 220-240 Volts ±10%, 50 / 60Hz. Mains input : Socket CE14 with C13, 2 poles + earth cable removable Power consumption : 770W maxi. Efficiency : > 84% of the maxi powerful. Operating temperature : +5 to +40 C. Coefficient of temperature / C : 0.01% for the voltage ; 0.05% for the current. Voltage on the earth : 100V Max. Presentation : Front-panel with sensitiv keypad, rear-panel with handle and cord storage area, metallic case with epoxy finish. 3 www.elc.fr

PROGRAMMABLE POWER SUPPLY EAN CODE : 3760244880871 2 outputs Powerfull DOUBLE ALR3206D VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS485 & 0-10V isolated LabVIEW as a standard PERFORMANCE : output in the rear-panel,used for remote-sensing COUPLING : Auto mode : Series, Parallel, Tracking FUNCTIONS : square, positive and negative ramp, rise or fall time ELEGANT : New design and feathery SPACE-SAVING : vertical & COMPACT BOX / 390W PRACTICAL : Lightweight with built-in handle and cord storage area. QUIET : Silent temperature-controlled fan cooling. LOCKING : configuration & stand-by 390 WATTS 2 x 0-32 V 0-6 A or 1 x ± 0-32 V 0-6 A or 1 x 0-64 V 0-6 A or 1 x 0-32 V 0-12 A LabVIEW ULTRA-COMPACT!! C!@!!! $ ' C Floating outputs : on 4mm safety terminals in the front-panel, and on spring terminal block with levers for 2mm² on the rear-panel. Automatic constant voltage and current operation. Channel 1 and 2 MASTER AND SLAVE Independent Tracking Series Parallel Output voltage 2 x 0-32 V ± 0-32 V 0-64 V 0-32 V Minimum voltage ± 10 mv ± 10 mv ± 20 mv ± 10 mv Adjustement accuracy 0.03% or ±10 mv (20 mv in series) Ripple (mv rms) < 0.7 mv < 0.7 mv < 1.5 mv < 1 mv Pics of commutation (BP 20 MHz) < 15 mvpp < 15 mvpp < 30 mvpp < 30 mvpp Regulation / load 0 to 100% 12 mv 12 mv 24 mv 40 mv Regulation / source ±10% 1 mv 1 mv 2 mv 1 mv Time of answer load 10 to 90% 2 ms 2 ms 2 ms 5 ms Display resolution 10mV 10mV 20mV 10mV Accuracy measurement 0.03% or ±10 mv (20 mv in series) Display 4 digits + parameters on graphic LCD Output current 2 x 0-6 A ± 0-6 A 0-6 A 0-12 A Minimum current 2 ma 2 ma 2 ma 10 ma Adjustement accuracy 0.03% or ±2 ma (10 ma in series) Ripple (marms) <1 ma <1 ma <1 ma <1 ma Regulation / load 0 to 100% 1 ma 1 ma 2 ma 2 ma Regulation / source ±10% 1 ma 1 ma 1 ma 1 ma Display resolution 2 ma 2 ma 2 ma 10 ma Accuracy measurement 0.03% or ±2 ma (10 ma in series) Display 4 digits + parameters on graphic LCD s Against short-circuits, by current regulation. Against overtemperature by fan and thermal circuit-breaker. Against overcurrent on main input, by internal fuses. Various and functions Dispaly : Graphic LCD 128 x 64 pixels with white backlight. Visualization of all parameters (CV, CC, RMT, etc...) Memory : 16, including 15 configurable. OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi. Functions : 6 available on U or I (Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot). Time adjustement from 10ms to 60mn. Remote sensing : 4 wires mode on the back-side's terminal blocks. Correction of the voltage drop in the wires : 2V Standby : output, enable / disabled and standby of the power supply. Interfaces All the interfaces are insulated of the output (150V max). USB and RS485 are standard. LabVIEW's drivers as a standard. Controller 0 10V : by direct input 0-10V for U for each channel or for U & I for channel 1 or potentiometer 10K or adjustable resistance 10K. In the back side on disconnect scribe terminal blocks. : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, CAT II. CEM : Complies with EN 61326-1 and EN 55011. Input voltage : 220-240 Volts ±10%, 50 / 60Hz. Mains input : socket C14 with C13 2 poles + earth cable removable Power consumption : 475W maxi. Efficiency : > 81% of the maxi powerful. Operating temperature : +5 to +40 C. Coefficient of temperature / C : 0.01% for the voltage and the current. Voltage on the earth : 100V Max. Presentation : Front-panel with sensitiv keypad, rear-panel with handle and cord storage area, metallic case with epoxy finish. 5 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880048 TRIPLE AL 936N EASY : Direct digital display of voltage and current, even in the series or parallel mode. SURE : Automatic disconnection each time the master and slave channel configuration is changed. COMPLETE : Third channel with fixed or variable position and voltage or current display. EFFECTIVE : Idc adjustment independent of load. QUIET : Silent temperature-controlled fan cooling. 200 WATTS 2 X 0-30V 0-3A or 1 X ± 0-30V 0-3A or 1 X 0-60V 0-3A or 1 X 0-30V 0-6A + 1 X 2-5,5V 3A or 1 X 5,5-15V 1A % C &! % $ C! $ $!! @! CHANNELS MASTER AND SLAVE AUXILIARY Configuration Independent Tracking Series Parallel Variable Variable Output voltage 2x 0-30V ± 0-30V 0-60V 0-30V 2-5,5V 5,5-15V Minimum voltage ± 10mV ± 10mV ± 20mV ± 10mV < 2V - Ripple (mv rms) 1mV 1mV 1mV 1mV 1mV 1mV Load regulation from 0 to 100% 12mV 12mV 50mV 24mV 12mV 10mV Line regulation from -6 to +7% 5mV 5mV 5mV 5mV 5mV 1mV Internal resistance 4mΩ 4mΩ 16mΩ 4mΩ 4mΩ 4mΩ Resp. for 10 to 90% load change 30µs 30µs 30µs 30µs 100µs 60µs Display resolution 100mV 100mV 100mV 100mV 10mV 100mV Display 14 mm 3 digit LED digital voltmeter Output current 2x 0-3A ± 0-3A 0-3A 0-6A 3A 1A Minimum current 10mA 10mA 10mA 20mA - - Ripple (ma rms) 1mA 1mA 1mA 4mA - - Load regulation from 0 to 100% 2mA 2mA 4mA 8mA - - Line regulation from -6 to +7% 1mA 1mA 1mA 5mA - - Display resolution 10mA 10mA 10mA 10mA 10mA 10mA Display 14 mm 3 digit LED digital ammeter Power supplies A and B (master and slave) The Standby mode disconnects the output terminals. It is automatic upon a change of mode. The Idc push-button shorts the output in the standby mode. It is used for setting Imax. I ndicators : green LED for voltage regulation red LED for current regulation. Display : automatic display switching depending on selected configuration. AUXILIARY power supply The Display button switches the display between voltage and current. The voltage is continuously adjustable from 2 to 15V. The max current goes from 3A to 1A after 5,5V. Short circuit protection, by current regulation. Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay. T ransformer primary overcurrent protection, by fuse. : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. Toroidal transformer, class II, complies with EN 61558-2-4. EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 410 VA. Dielectric strength : 2300V between input, output and chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metalcase, epoxy finish. 7 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880031 DOUBLE ALR3003D PRATICAL : Digital display of voltage and current. EASY : Automatic mode select button : separate, tracking and series. PRECISE : Fine voltage adjustment. QUIET : Silent temperature-controlled fan cooling. 180 WATTS 2 X 0-30V 0-3A or 1 X ± 0-30V 0-3A or 1 X 0-60V 0-3A or 1 X 0-30V 0-6A* & $ C! $ & C! $ $!! @! CHANNELS MASTER AND SLAVE Independent Tracking Series Output Voltage 2x0-30V ± 0-30V 0-60V Minimum Voltage ± 10mV ± 10mV ± 20mV Ripple (mv rms.) 1mV 1mV 1mV Load regulation from 0 to 100% 12mV 12mV 50mV Line regulation from -6 to +7% 5mV 5mV 5mV Internal resistance 4mΩ 4mΩ 16mΩ Resp. for 10 to 90% load charge 30µs 30µs 30µs Dispaly resolution 100mV 100mV 100mV Display 14mm 3 digit LED Voltmeter Output current 2x0-3A ± 0-3A 0-3A Minimum current 10mA 10mA 10mA Ripple (ma rms.) 1mA 1mA 1mA Load regulation from 0 to 100% 2mA 2mA 4mA Line regulation from -6 to +7% 1mA 1mA 1mA Dispaly resolution 10mA 10mA 10mA Display 14mm 3 digis LED Ammeter : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. Toroidal isolation transformer, class II, complies with EN 61558-2-4. EMC : Complies with EN 61326-1, performance criteria B, and Power Supplies A and B (master and slave) The "Tracking/Series" mode internally connects the - terminals of the master and + terminals of the slave (mid point). All adjustments are made from the slave power supply. The parallel mode* (external connection) provides up to 6 amperes. Indicators : green LED for voltage regulation red LED for current regulation. Display of voltage and current on 14 mm 3 digit red LED displays. Short circuit protection, by current regulation. Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay. T ransformer primary overcurrent protection, by fuse. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 400 VA. Dielectric strength : 2300V between input, output and chassis. Outputs : Presentation : safety sockets and safety inverted earth socket. screen-printed polycarbonate front panel, meta case, epoxy finish. 8 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880024 SIMPLE AL 924A PRACTICAL : Digital display of voltage and current. PRECISE : Coarse and fine voltage adjustment. - Adjustable current from 0 to 10A or 0 to 1A. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short circuit protection. ' &!! $ 300 WATTS 0-30V 0-10A & C $ C $!! @! Voltage Floating outputs on 4 mm safety terminals. Automatic constant voltage operation. Adjustable from 0 to 30V (0 to + or -5mV) with fine adjustment (about 2 Volts). Regulation : < 40mV for a load variation from 0 to 100%. < 25mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance: < 4 mω. Indicator : green LED for voltage regulation. Display : 14mm 3 digit LED digital voltmeter. Resolution : 100 mv. Automatic constant current operation. Two selectable current ranges : 10A or 1A. Adjustable from 0 to 10A or from 0 to 1A, depending on the selected range. Regulation : < 10 ma for a 10% line charge. < 20 ma for a load change from 0 to 100%. Ripple : < 10 ma peak to peak or 3,5 ma rms. Indicators : red LED for current regulation. Display : 14 mm 3 digit LED digital ammeter. Resolution : 10 ma on 1A range, 100 ma on 10A range : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 620 VA. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. Short circuit protection, by current regulation. Overtemperature protection, by fan, by thermal circuit-breaker and by relay on the transformer. Transformer primary overcurrent protection, by fuse. 9 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880017 SIMPLE AL 781NX PRACTICAL : Digital display of voltage and current. PRECISE : Coarse and fine voltage adjustment. - Adjustable current from 0 to 5A or 0 to 1A. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short circuit protection. ' &!! $ 150 WATTS 0-30V 0-5A & " C ' C $!! @! Voltage Floating outputs on 4 mm safety terminals. Automatic constant voltage operation. Adjustable from 0 to 30V (0 to + or -5mV) with fine adjustment (about 2,5 Volts). Regulation : < 20mV for a load variation from 0 to 100%. < 15mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance : < 4 mω. Indicators : green LED for voltage regulation. Display : 14mm 3 digit LED digital voltmeter. Resolution : 100 mv. Automatic constant current operation. Two selectable current ranges : 5A or 1A. Adjustable from 0 to 5A or from 0 to 1A, depending on the selected range. Regulation : < 10 ma for a 10% line charge. < 15 ma for a load change from 0 to 100%. Ripple : < 6 ma peak to peak or 2,1 ma rms. Indicators : red LED for current regulation. Display : 14mm 3 digit LED digital ammeter. Resolution : 10 ma. : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 315 VA. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. Short circuit protection, by current regulation. Overtemperature protection, by thermal circuit-breaker and by relay on the transformer. Transformer primary overcurrent protection, by fuse. 10 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880000 SIMPLE ALR3003 PRACTICAL : Digital display of voltage and current. - Cord housing. PRECISE : Coarse and fine voltage adjustment. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short-circuit protection. QUIET : Controlled fan cooling.!!! & & 90 WATTS 0-30V 0-3A '! C! ' C! @! Voltage Automatic constant voltage operation. Adjustable from 0 to 30 Volts (0 to ± 10 mv) with fine adjustment (about 2 Volts). Regulation : < 12 mv for a load variation from 0 to 100%. < 5 mv for a line variation of 10%. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance : < 4 mω. Display : 14 mm 3 digits LED digital voltmeter. Resolution : 100 mv Automatic constant current operation. Adjustable from 0 to 3 Amps. Regulation : < 1 ma for a line charge of 10 %. < 2 ma for a load charge from 0 to 100%. Ripple : < 1 ma rms. Display : 14 mm 3 digits LED digital ammeter. Resolution : 10 ma : Class II, Safety Extra Low Voltage (SELV) outputs with insulation enhanced transformer. Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and level : IP 21. Input voltage : 230 V ±10%, 50 / 60 Hz. Main input : Cord with 2 poles immovable. Power consumption : 176 VA max. Dielectric strength : 3000 V between the input and the output. Presentation : screen-printed polycarbonate front panel, metal case with cord housing, epoxy finish. s Short-circuit protection by current regulation. Overtemperature protection by temperature-controlled fan, relay and thermal circuit-breaker. Transformer primary and secondary overcurrent protection by fuse. 11 www.elc.fr

ADJUSTABLE POWER SUPPLY EAN CODE : 3760244880055 TRIPLE + INTERFACES AL 991S COMPLETE : Three outputs available simultaneously. PRATICAL : Digital voltage display. USEFUL : Setting memory. COMPATIBLE : RS232, USB* and LABVIEW interfaces. PROTECTED : Short circuit protection. 48 WATTS RS232 + LABVIEW + USB* 0 to ± 15V 1A or 0 to 30V 1A and 2 to 5,5V 3A and -15 to +15V 0,2A LabVIEW ' $! C *OPTION : USBRS232! $ C! @!!! Voltage Three outputs available simultaneously : - Power supply A : adjustable from 0 to ±15 Volts balanced. or 0 to 30V with the -15V terminal as reference. - Power supply B: adjustable from + 2 to + 5,5 Volts. - Power supply C: adjustable from - 15 to + 15Volts. Voltage adjustment : push-button selection of output A, B or C. Voltage incremented and decremented by four push-buttons : -1 V + 1 V - 0,1 V + 0,1V Automatic storage of the three voltage settings. Regulation : < 20mV for a load variation from 0 to 100%. < 10mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. I ndicators : Three red LEDs showing the selected output for display and adjustment. Display : 14 mm 3 digit LED digital voltmeter for the three outputs. Resolution : 100 mv. EMC : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. : Complies with EN 61326-1, performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). s Max I : 1A on output A. 3A to 5,5 Volts and 1,5A to 2 Volts on output B. 0,2A on output C. Display : limiting on one output causes the display to blink ; it shows : Ic.A, Ic.b, Ic.C or +Ic, depending on the overloaded output(s). Short circuit protection, by current limit. Transformer primary overcurrent protection, by fuse. Chassis ground output on 4 mm inverted safety socket. Interface RS-232 link, 9-way male SUB-D plug. USB option: Kit includes an adaptator null modem und RS232 cable Software LG991S for Windows95* or + LG991S LV and base VI under LabVIEW** Softwares are available for download on website www.elc.fr (*is a registered trademark of Microsoft Co.) (** (*is a registered trademark of National Instruments.) Power consumption : 100 VA max. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. 12 www.elc.fr

ADJUSTABLE & MULTIPLE POWER SUPPLY EAN CODE : 3760244880130 DOUBLE AC/DC ALR3002M COMPLETE : DC and AC voltages available simultaneously. POWERFUL : generator. PRACTICAL: No common reference. - Cord housing. PROTECTED : The DC output is protected by current regulation. - The AC outputs are protected by auto reset thermal circuit-breakers. 120 WATTS 0-5, 6, 12 or 30V 0-25mA, 250mA or 2,5A DC and 6 or 12 or 24V 5A AC! & &!! ' " C! @! " C DC outputs Automatic constant voltage operation. Four choices of voltage ranges with adjustement by trimer from 0 to max : 0 to 5V, 0 to 6V, 0 to 12V or 0 to 30V. Regulation : < 10 mv for a load variation from 0 to 100%. < 5 mv for a line variation from -6 +7%. Ripple : < 3 mv peak to peak or 1mV rms. Internal resistance : < 5 mω. Display : 14mm 3 digits LED digital voltmeter. Resolution : 10mV for 5 and 6V and 100 mv for 12 and 30V. Automatic constant current operation. Three choices of current ranges with adjustement by trimer from 0 to max : 0 to 25mA ; 0 to 250mA ; 0 to 2,5 Amps. Regulation : < 2 % for a load change from 0 to 100%. Ripple : < 1 ma rms. Display : 14mm 3 digits LED digital ammeter. Resolution : 100µA on 25mA range, 1mA on 250mA range, 10mA on 2,5A range. s Short circuit protections by current regulation. Overtemperature protection by transformer secondary switching relay and thermal circuit-breakers. Transformer primary overcurrent protections by fuse. AC outputs Three outputs with common point. Voltages : 6 Volts, 12 Volts and 24 Volts. No-load voltage 5% maximum above rated voltage. Max I : 5 Amps on 6,12, or 24V. s Secondary overcurrent protection by auto-reset thermal circuit-breakers. Precautions The AC and DC circuits can be used simultaneously but with a max power of 120W. EMC : Class II, Safety Extra Low Voltage (SELV) outputs with insulation enhanced transformer. Complies with EN 61010-1, overvoltage category II, pollution degree 2. : Complies with EN 61326-1, performance criteria B, and level : IP 21. : Transformer primary overcurrent protection, by fuse. Main input : 2 poles cable immovable. Power consumption : 250 VA max. Dielectric strength : 3000V from input to output. Presentation : screen-printed polycarbonate front panel, metal case with cord housing, epoxy finish. 13 www.elc.fr

MULTIPLE POWER SUPPLY EAN CODE : 3760244880123 DOUBLE AC/DC AL 843A COMPLETE : DC and AC voltages available simultaneously. PRACTICAL : No common reference. PROTECTED : The DC output is protected by fold-back current limiting. The AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6 or 12V 10A or 24V 5A DC and AC $ & % " C! & C! $ $!! @! DC outputs Three switchable outputs : 6V, 12V or 24V. Accuracy : ± 1% Regulation : < 40 mv at 6 and 12 V outputs for a load variation from 0 to 100%. < 20 mv at 24 V output for a load variation from 0 to 100%. Ripple : < 5 mv peak to peak or 1,8 mv rms. Internal resistance : < 4 mω. Max I : 10A at 6 or 12V output. 5A at 24V output. Short circuit protection by fold-back current limit, allowing continuous short circuit without overheating. AC outputs Three outputs with common point. Voltages : 6 Volts, 12 Volts and 24 Volts ± 10%. No-load voltage 5% maximum. Max I : 10A at 6 and 12V outputs. 5A at 24V output. Secondary overcurrent protection by auto-reset thermal circuit-breakers. Precautions The AC and DC circuits can be used simultaneously but with a max power of 120W. EMC : Class I, enhanced safety between mains input and outputs. Complies with EN 61010-1, overvoltage category II, pollution degree 2. : Complies with EN 61326-1, performance criteria B, and Transformer primary overcurrent protection, by fuse. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 250 VA max. Dielectric strength : 3700V from input to output, 2200V from input to chassis. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. 14 www.elc.fr

MULTIPLE POWER SUPPLY EAN CODE : 3760244880109 DOUBLE AC/DC AM061205 COMPLETE : DC and AC voltages available simultaneously. PRACTICAL : No common reference. - AC and DC power-on indicators. PROTECTED : The DC output is protected by current regulation. - The AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6 or 12V 5A DC and AC C $ ' " C $ " @! DC outputs Two switchable outputs : 6 Volts or 12 Volts. Accuracy : ± 1% Regulation : < 20mV for a load variation from 0 to 100%. < 5mV for a 10% line variation. Ripple : < 3 mv rms including : <3mV peak to peak of the signal at 100 KHz <4mV peak to peak of the signal at 100 Hz <12mV peak to peak of switching peak Hold up time : 25ms at half load and 12ms at full load (190V line input). Indicator : green power-on LED indicator. Max I Idc : 5A at 6 or 12V output. : 5,5A. Short circuit protection by current limiting, Overcurrent protection on source by fuse on main input AC outputs Two outputs with common point. Voltages : 6 Volts and 12 Volts + or - 5%. No-load voltage 10% maximum. Indicator: green power-on LED indicator. Max I : 5A at 6V or 12V output. Short circuit and overcurrent protection by auto-reset thermal circuit-breakers. Precautions Power supply max. power is of 120 Watts The AC and DC circuits can be used simultaneously. EMC Input voltage Mains input : Class II, double insulation Complies with EN 61010-1, overvoltage category II, pollution degree 2. : Complies with EN 61326-1, performance criteria B, and : 230V ±10%, 50 / 60 Hz. : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 145 VA max. : against overcurrent at the input by fuse level : IP 30 Dielectric strength : 3000V between input to output. Presentation : Metal case with epoxy finish 15 www.elc.fr

AC POWER SUPPLY & DC RECTIFIER EAN CODE : 3760244880116 DOUBLE AC/DC AM061210 COMPLETE : DC rectified and AC voltages available simultaneously. PRACTICAL : AC and DC power-on indicators. PROTECTED : The DC rectifier output and the AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6V 20A 12V 10A DC and AC " C "! C ' $ & @! DC outputs Two switchable outputs : 6 Volts or 12 Volts. Voltage rectified only Indicator : green power-on LED indicator. Max I : 20A at 6V output. : 10A at 12V output Short circuit protection by current limiting, Overcurrent protection on source by fuse on main input AC outputs Two outputs with common point. Voltages : 6 Volts and 12 Volts + or - 5%. No-load voltage 10% maximum. Indicator: green power-on LED indicator. Max I : 20A at 6V output. or 10A at 12V output Short circuit and overcurrent protection by auto-reset thermal circuit-breakers. Precautions Power supply max. power is of 120 Watts The AC and DC outputs can be used simultaneously on circuits without common refrence. EMC Input voltage Mains input : Class II, double insulation Complies with EN 61010-1, overvoltage category II, pollution degree 2. : Complies with EN 61326-1, performance criteria B, and : 230V ±10%, 50 / 60 Hz. : double insulation cord with 2 poles immovable. Power consumption : 145 VA max. : against overcurrent at the input by fuse level : IP 30 Dielectric strength : 3000V between input to output. Presentation : Metal case with epoxy finish 16 www.elc.fr

UNIVERSELLE BENCH POWER SUPPLY EAN CODE : 3760244880093 UNIVERSAL AL 841C UNIVERSAL : Choice of six voltages. PRACTICAL : ON/OFF switch. - Power-on indicator. PROTECTED : Short circuit protection. RESISTANT TO SHOCK : Polycarbonate case 12 WATTS 3 / 4,5 / 6 / 7,5 / 9 or 12V 1A ' ' $ % C &! & C! @! Voltage Output voltage : 3 V or 4,5 V or 6 V or 7,5 V or 9 V or 12 V selectable Accuracy : ± 4%. Regulation : < 20mV for a load variation from 0 to 100%. < 15mV for a 10% line variation. Ripple : 5 mv peak to peak or 1,8 mv rms. Internal resistance : < 20 mω. The max current is constant and independent of the selected output. Max I : 1 A. Indicator Green power-on LED indicator. : Class II - Safety Extra Low Voltage (SELV) output Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). ON/OFF control : toggle switch. Power consumption : 30 VA max. Dielectric strength : 3000Vac from input to output. Presentation : Polycarbonate case screen-printed. Short circuit protection, by current limit. Transformer primary overcurrent protection, by fuse. 27 www.elc.fr

SYMMETRIC BENCH POWER SUPPLY EAN CODE : 3760244880079 +15V or 12V or 24V ALF1501D PRATICAL : ON/OFF switch. - Power-on indicator. - 30 W available on the positive output alone. PRECISE : Output ripple < 3mV rms. - Output voltage adjustable from ±10 to ±15V. PROTECTED : against Short circuit. RESISTANT TO SHOCK 30 WATTS +/- 10 to 15V 1A or 12V 2,5A or 24V 1A ' ' $ C &!! ' C! @! Balanced-output power supply with common 0V. Floating outputs on 4-mm safety sockets. Ajustable output voltages : from ±10 to ±15V +15V output Regulation : < 15mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 3mV peak to peak of switching signal < 8mV peak to peak of the signal at 100Hz < 10mV peak to peak of switching spikes -15V output Regulation : < 10mV for a load charge from 0 to 100%. < 2mV for a line charge from 198 to 264 V. Ripple : < 3mV rms including : < 2mV peak to peak of switching signal < 4mV peak to peak of the signal at 100Hz < 15 mv peak to peak of switching spikes 24V Output (Adjustable from 20 to 30V) Available between output + and - Regulation : < 15mV for a load charge from 0 to 100% < 2mV for a line charge from 198 to 264V Ondulation : < 5mV rms including: < 3mV peak to peak of the switching signal < 12mV peak to peak of the signal at 100Hz < 30mV peak to peak of switching spikes Indicators 2 Green +15V and -15V power-on LED indicator. +15V (alone) I max : 3A at 10V 2,5A at 12V 2A at 15V -15V (alone) I max : 1,1A in short-circuit condition 1A from 10 to 15V 24V (Adjustable from 20 to 30V) I max : 1A from 20 to 30V Power Max output power : 30W. I max ±15V : 1A s Against short-circuits by current limit and disjunction. Against overcurrent on source by fuse. : Class II, Safety Extra Low Voltage (SELV) Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and level : IP30. Operating temperature : 5 to 40 C Input voltage : 198 to 264 V, 50 / 60 Hz. Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 40W max. ON/OFF control : toggle switch Dielectric strength : 3000 V between input to output. Presentation : polycarbonate case screenprinted. 29 www.elc.fr

SYMMETRIC POWER SUPPLY EAN CODE : 3760244880086 + 15V or 12V or 24V ALF1502D PRATICAL : ON/OFF switch. - Power-on indicator. - 60 W available on the positive output alone. PRECISE : Output ripple < 3mV rms. - Output voltage adjustable from ±10 to ±15V. PROTECTED : against Short circuit. RESISTANT TO SHOCK 60 WATTS +/- 10 to 15V 2A or 12V 5A or 24V 1A ' ' $! C &! " $ C! @! Balanced-output power supply with common 0V. Floating outputs on 4-mm safety sockets. Ajustable output voltages : from ±10 to ±15V. +15V output Regulation : < 15mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 3mV peak to peak of switching signal < 5mV peak to peak of the signal at 100Hz < 15mV peak to peak of switching spikes -15V output Regulation : < 30mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 4mV peak to peak of switching signal < 4mV peak to peak of the signal at 100Hz < 15 mv peak to peak of switching spikes 24V Output (Adjustable from 20 to 30V) Available between output + and - Regulation : < 15mV for a load variation from 0 to 100% < 2mV for a line variation from 198 to 264V Ondulation : < 3mV rms including: < 5mV peak to peak of the switching signal < 8mV peak to peak of the signal at 100Hz < 25mV peak to peak of switching spikes Indicators Green power-on LED indicator. Overheat or overcurent red LED "status" indicator. +15V (alone) I max : 5,5A on the short-circuit 5A from 10 to 12V 4A at 15V -15V (alone) I max : 2,1A in short-circuit condition 2A from 10 to 15V 24V (Adjustable from 20 to 30V) I max : 2,1A at the short circuit 2A from 20 to 30V Power Max output power : 60W. I max ±15V : 2A s Against short-circuits by current limit. Against overcurrent on source by fuse. Overtemperature protection by thermal circuit-breaker : Class II, Safety Extra Low Voltage (SELV) Complies with EN 61010-1, overvoltage category II, pollution degree 2. EMC : Complies with EN 61326-1, performance criteria B, and level : IP30. Operating temperature : 5 to 40 C Input voltage : 198 to 264 V, 50 / 60 Hz. Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 78W max. ON/OFF control : toggle switch Dielectric strength : 3000 V between input to output. Presentation : polycarbonate case screenprinted. 31 www.elc.fr