Directley mounted CAN-controls for proportional directional spool valves type PSL/PSV (valve bank design) acc. to D , D

Similar documents
Proportional pressure reducing valve type KFB 01 (hydraulic joystick)

Connection blocks type HMP with integrated lifting and lowering function for proportional spool valves type PSL and PSV, size 2 and 3

Discontinued type. 4/3-way proportional pressure reducing valve type FB and KFB (pilot valves)

Proportional pressure limiting valve Type PMV and PMVP Type PMVS and PMVPS (with external control oil inlet)

Lifting / Lowering valve type HSV and HZV

Proportional, solenoid actuated flow control valves type SE and SEH

4/3- and 3/3-way directional seated valves type VH (R) and VHP

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Lifting / Lowering valve type HSV

Clamping modules type SMD 2 and NSMD 2 for actuating hydraulic clamping devices

These 2/2-way directional cone seated valves show zero leakage while in blocked shifting position. The following versions are available:

Intermediate plate type NZP hole pattern conforming NG 6 (DIN A6)

Directional spool valve type SG and SP

Check valves type CRK, CRB and CRH to screw-in into simple to manufacture tapped holes

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief

Load-holding valves type LHDV

Directional spool valves type SWPN

Pressure controlled the 2-way directional valve type CNE

Proportional directional spool valve type PSL and PSV according to the Load-Sensing principle size 2 (valve bank design)

Releasable twin check valve type DRH

Proportional pressure relief valve, directly operated, rising characteristic curve

Axial piston variable displacement pump type V60N, Serie 03

Directional spool valve type SG and SP

Axial piston variable displacement pump type V60N

1. General. 2. Mounting. D 7055 Electrical operation 2.1. May be utilized for the following directional spool valves:

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional directional spool valve type EDL

Proportional directional spool valve type EDL

Brief operating manual for hydraulic power pack type MPN

Check valve type ER and EK

Valve bank type BNG. Product documentation. Manifold mounting Operating pressure p max : Flow rate Q max : 400 bar 60 lpm D 7788 BNG

2-way proportional throttle valve for block installation

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

D Additional information Flow Q max Operating pressure p max. = 19.9 lpm (1450 rpm) = 700 bar. Order example

Hydraulic power packs type MP turn-key versions with cover plate only or complete with tank equipped with pumps acc. to D 7200

Releasable twin check valve type DRH

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional directional spool valve type PSL and PSV according to the Load-Sensing principle size 2 (valve bank design)

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Flow control valve type SJ

FC2-1L Flow Control Valve, double

Hydraulic Valves «DSV»

Shut-off valve type AVT and AVM

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Check valve type ER and EK

Releasable check valve type RH

4/3 proportional directional valve, direct operated, with pq functionality and field bus interface (IAC-P)

Releasable check valve type HRP

Throttle valve and throttle check valve type CQ, CQR and CQV

Variable displacement axial piston pump type V30D

Linear-Transducer LMP48 - A

Proportional directional valve, direct operated, with pq functionality

3/2 and 4/2 directional seat valves with solenoid actuation

Double throttle check valve Type Z2FS 10

Proportional flow control valve, with integrated pressure compensator

Paddle-wheel flow controller for On/Off control

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Directional servo-valve of 4-way design

CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

CONTINENTAL HYDRAULICS VED03MX

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

Proportional amplifier type EV22K5

Flow sharing control block in sandwich plate design M7-25

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Hydraulic power pack type LP

Pump element type MPE and PE for radial piston pumps

2/2-way poppet valves with solenoid operation Type KSDER1

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Variable displacement axial piston pump type V80M

Pressure relief valve, pilot operated

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Application Software Dual Path Control DPC

Proportional Pressure Reducing Valve PDM08130

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Paddle-wheel flow controller for On/Off control

Throttle valve and shut-off valve type CAV

Pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

Proportional Throttle Valves Series TDL

Axial Piston Variable Double Pump A8VO

Proportional reducing valves

40 l/min (11 GPM) p max

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Heat Meter Integrator

Insertion magnetic inductive flowmeter

Lexium integrated drives

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Solenoid Pilot Operated Proportional Directional Control Valve

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Our policy is one of continued research and development. We therefore reserve the right

Proportional flow control valve, 2-way version

Check valve, pilot operated

GEMÜ 539 esydrive Motorized globe valve

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

4-way directional servo-valve

Transcription:

Directley mounted CAN-controls for proportional directional spool valves type PSL/PSV (valve bank design) acc. to D 7700-2, D 7700-3 Main parameter Nomenclature: Design: Oper. pressure Flow rating Proportional directional spool valve acc. to the Load-Sensing-principle with directly mounted CAN-controls Valve bank design max. 420 bar max. 200 lpm in total max. 120 lpm per section For additional information: ' Proportional directional spool valve type PSL/PSV D 7700-2 ' Proportional directional spool valve type PSL/PSV D 7700-3 ' Programmable logic valve control type PLVC D 7845 M 1. General These proportional directional spool valves serve to control both, the direction of movement and the load-independent, stepless velocity of the hydraulic consumers. In this way several consumers may be moved simultaneously, independently from each other at different velocity and pressure ratings, as long as the sum of the partial flows needed for this is within the total delivery supplied by the pump. This actuation version with directly mounted CAN-actuation is a supplement to the already actuation variants described in D 7700-2, D 7700-3. Advantages of this design: - Easy electrical connection - Integrated position transducer - Readily calibrated at HAWE (I min, I max, etc.) - Configurable valve characteristics (linearization, fine control range etc.) - Adjustable ramps - Improved response behavior - Adjustable max. flow - Diagnostic facility (fault detection, spool position etc.) 2.1 The electrical connection (power and CAN-Bus) between the valve sections is via internal lines. Table of content 1. General... 1 2. Layout, Main data... 2 2.1 Type coding key... 2 2.2 Actuation variants... 3 3. Additional data... 4 3.1 General and hydraulic... 4 3.2 Electrical... 5 3.3 Certificates and environmental tests... 5 4. Dimensions... 6 5. Append... 7 5.1 Safety notes... 7 5.1.1 Transport and storage... 7 5.1.2 Installation... 7 5.2 Assembly and installation notes... 7 5.2.1 Mounting... 7 5.2.2 Piping... 7 5.2.3 Seal kits... 7 5.2.4 Servicing of components... 7 5.3 CAN-Bus-controls... 8 5.3.1 General... 8 5.3.2 Lay-out of CAN-Bus systems... 8 5.3.3 Data flow and addressing... 8 5.4 Basic lay-out... 9 2009 by HAWE Hydraulik HAWE HYDRAULIK SE STREITFELDSTR. 25 81673 MÜNCHEN D 7700 CAN Directley mounted CAN-controls for prop. directional spool valves February 2011-00

D 7700 CAN page 2 2. Layout, Main data 2.1 Type coding key The type codings printed bold are detailed in this brochure. For all other details, see D 7700-2 or D 7700-3. Order example: PSV 31/D 170-2 ; -A 2 J 25/25 /EA CAN-C/2 < -A 2 J 25/25 /E CAN/2 < -A 2 J 25/25 /E CAN/2 < -E 4-AMP 12 = - > -0-PLVC/250? ; Connection block < Valve section (with directly mounted CAN-controls) = End plate > Specification for the socket? Specification for the CAN-protocol

D 7700 CAN page 3 2.2 Actuation variants Order example: PSV 31/D 170-2 -A 2 J 25/25 /EA CAN-C/2 -A 2 J 25/25 /E CAN/2 -A 2 J 25/25 /E CAN-C/2 -E 4-AMP -0-PLVC/250 Actuation Electrical actuation Description Electro-hydraulic Combined with manual actuation Coding E EA Suffix for CAN-controls All directly mounted CAN-controls do come with transducer. Basic rule for combinations: There must be min. one socket (coding CAN-C or CAN-T) either at the first or last valve section Directly mounted CAN-controls Description CAN-knot incl. socket CAN-knot incl. socket CAN-knot (at the first or last valve and terminating resistor (all valve sections) section) 120 Ω (at the first or last valve section) Coding CAN-C CAN-T CAN Possible combinations (examples) CAN-C - CAN -... - CAN - Socket at the first valve section CAN-T - CAN - - CAN - Socket with terminating resistor at the first valve section CAN - CAN - - CAN-C - Socket at the last valve section CAN-C - CAN - - CAN-C - Socket at the first and last valve section Socket Description 4-pin socket 4-pin socket (spec. AMP, with protective circuitry) (spec. SAAB, with protective circuitry) Coding AMP AMS Terminal assignment 1 Power + 1: CAN-L 2 CAN-L 2: Power + 3 CAN-H 3: Power - / GND 4 Power - / GND 4: CAN-H Suited plug Co. AMP No. 282 764-1 Co. AMP No. 1-967 059-1 CAN-protocol - 0 (default) - 1 (customer-specific) Description Protocol Baud rate Spec. for communication with spec. in kbaud type PLVC Coding - PLVC /125 - CANopen /250 (default) - J1939 /500 /1000

D 7700 CAN page 4 3. Additional data 3.1 General and hydraulic Type coding Design PSL and PSV Directional spool valve, valve bank, all-steel design Mounting Valve bank: M8; see dimensional drawings in sect. 4 Installed position Any Hydraulic connection P = Pressure inlet (pump) / lead-on R = Return A, B = Consumer ports U, W = Load-signal outlet at the indiv. spool valve section LS = Load-signal outlet e.g. connection of pump metering valve at PSV M = Pressure gauge port (pump side) Z = Pilot pressure port (20...40 bar inlet, 20 or 40 bar outlet) T = Control oil return port Y = Load-signal inlet port Port dimensions dep. on type coding, see D 7700-2, D 7700-3 Surface treatment All surfaces corrosion-inhibiting, gas nitrided Actuation coding suffix E. CAN = nickel galvanized Mass (weight) approx. Connection blocks, valve sections, end plates, see D 7700-2, D 7700-3 Actuation coding suffix E. CAN = +0.3 kg Pressure fluid Hydraulic fluid acc. to DIN 51524 table 1 to 3; ISO VG 10 to 68 acc. to DIN 51519 Viscosity range: min. approx. 4 mm 2 /sec; max. approx. 1500 mm 2 /sec Optimal operation range: approx. 10... 500 mm 2 /sec Also suitable are biologically degradable pressure fluids of the type HEPG (Polyalkylenglycol) and HEES (synth. Ester) at operation temperatures up to approx. +70 C. HETG (e.g. rape seed oil) or water based fluids e.g. HFA or HFC must not be used! Temperature Ambient: approx. -40... +80 C; Oil: -25... +80 C, pay attention to the viscosity range! Start temperature down to -40 C are allowable (Pay attention to the viscosity range during start!), as long as the operation temperature during consequent running is at least 20K higher. Biological degradable pressure fluids: Pay attention to manufacturer's information. With regard to the compatibility with sealing materials do not exceed +70 C. High temperatures accelerate the aging of electronic components. Rec. contamination class ISO 4406 18/14 Operating pressure Control circuit Flow Flow metering p max = 420 bar; Ports P, A, B, LS, M, Y, U, W p min = 50 bar The max. pressure achievable at the consumer side of the spool valves is lowered by the amount equivalent of the internal control pressure drop at the 3-way flow regulator of the PSL (see curve) Return port R(R1) 50 bar; port T pressure less with separate pipe (e.g. 8x1) to the tank, port Z approx. 20 (outlet); 40 bar (inlet) For control pressure, see Q-I-characteristics. The internal control oil circuit is sufficiently protected against contamination caused malfunctions by means of a disk filter. max. consumer flow acc. to the flow rate coding in the type coding Adjustment in 1/1000-steps, linearity ensured via individual calibration of the CAN-knots with the correction factors being saved in the control software Curves see D 7700-2, D 7700-3

D 7700 CAN page 5 3.2 Electrical Supply voltage U B Current rating I max Current consumption I V Socket Protocol 12 30 V DC max. 10 A max 800 ma at U B = 24 V DC (per valve section) max 1.5 A at U B = 12 V DC (per valve section) AMP = 4-pin AMP-JPT suited plug Co. AMP No. 282 764-1 AMS = 4-pin AMP-JPT suited plug Co. AMP No. 1-967 059-1 Conforming CANopen protocol definition DS-301 device profile DSP-408 "Device profile fluid power technology proportional valves and hydrostatic transmissions" Baud rate see specifications in sect. 2.2 CAN-Addressing Addressing via identifier, for description see sect. 5.3 3.3 Certificates and environmental tests EMV E1-ECE-directive No. 10 revision 3-11 July 2008 Protection class IP 67 DIN 40050-9 Salt spray test EN 60068-2-11 500 h Shock test EN 60068-2-29 25 g, 3-axis Oscillation test EN 60068-2-6 5..500 Hz, 2 mm amplitude (5..25 Hz), 5.0 g (25..500 Hz), 3-axis Change of temperature test EN 60068-2-14-40 C - +85 C (1.5 K/min) Cold test EN 60068-2-1-40 C Damp/heat test, cyclic EN 60068-2-30 95% moisture, 24 h Dry/heat test EN 60068-2-2 85 C, 16 h

D 7700 CAN page 6 4. Dimensions General Actuation suffix E.CAN-C, E.CAN-T Actuation suffix E.CAN PSL/PSV size 2 PSL/PSV size 3 B 49.5 49.5 B1 39.5 49.5 H 99.5 110.. 123 H1 277 303.5 H2 117.5 127.5 T 79.5 80 B2 39.5 49.5 Terminal assignment AMP-socket 4 Power - / GND 3 CAN-H 2 CAN-L 1 Power + Accesory: Line connector kit order No 6217 0180-00 Terminal assignment AMS-socket 1 CAN-L 2 Power + 3 Power - / GND 4 CAN-H Accesory: Line connector kit order No 6217 0180-00

D 7700 CAN page 7 5. Appendix 5.1 Safety notes All installation, set-up, maintenance and repairs must be performed by authorized and trained staff. The use of this product beyond the specified performance limits, use of non specified fluids and/or use of not genuine spares will cause the expiration of the guarantee. The general operating manual for mounting initial operation and service of hydraulic components and systems has to be observed! 5.1.1 Transport and storage Like with all hydraulic components attention has to be paid on proper storage and suitable packing of the product. The combination of hydraulic valve and electronic controls does not require any special care The plastic socket must not be mechanically stressed therefore it must not be used as handle etc.! 5.1.2 Installation The following notes, which prevent improper operating conditions have to be taken into account to ensure safe function and a long service life of the PSL/PSV CAN valve knot: - Mounting of the valves nearby machine parts and sub-assemblies which generate great development heat (e.g. exhaust) has to be avoided. - There must be sufficient distance to radio devices. - An emergency-stop of the power supply has to be provided. The emergency-stop at the machinery must be easily accessible at for the operator. The manufacturer of the machine (the vehicle) has to ensure that the machine achieves a sure state after the emergency stop has been actuated - One of the safeguarding mechanisms against bus interruptions, supported by the device, has to be employed. (Nodeguarding, Heartbeat) - The power supply (line and fuse) must be dimensioned sufficiently to cope with the power demand. Each valve section has a max. current consumption of ca. 1.5 A at 12 V DC or 0.8 A at 24 V DC. - The GND-line has to be dimensioned accordingly to the power supply line. The reference potential for all CAN users should vary as little as possible between the devices and be identical to the GND-connection for the power supply. - All valve knots have to be disconnected to any electric welding work. - All sockets of the valve bank have to be safeguarded against penetrating water by proper attachment with installing all necessary seals. - Use only suited bus lines within the bus network. The lines should be twisted and shielded. The characteristic impedance must be approx. 120 Ω. - Terminating resistors of 120 Ω have to be provided on both two ends of the CAN-Bus network. - Valve electronics and the respective solenoid body are sealed and are screwed together. Therefore they should not be separated. Take care of proper sealing during reassembly when replacing the valve spool or valve body. - A sufficient distance to sources of magnetic fields e.g. strong permanent magnets, eddy-current brakes, etc. has to be maintained - When the bus and power supply lines are separated from the valve sections for servicing it is mandatory to use new lines and seals. Care has to be taken that the end cap is properly positioned. New lines are available at HAWE. The following rules have to be observed during operation: - Flawless operation of the controls is only guaranteed between -40 C to +85 C. - Only emergency operation is available within a certain temperature range if the device detects internal overheating. - The surface of the solenoid may become hot during operation danger of burning! - The power supply voltage must be within the specified range. Excessive or permanent deviations may harm the electronics. 5.2 Assembly and installation notes 5.2.1 Mounting The mounting of the valve bank to the frame or machinery must be performed in such a way that no stress is induced. It is recommended to mount the valve bank via 3 bolts with elastic washers between valve body and frame. 5.2.2 Piping Only fittings with soft seals are to be used. Do not exceed the specified torque ratings. 5.2.3 Seal kits Size 2 Size 3 Connection block DS 7700-21 DS 7700-31 Valve section DS 7700-22 DS 7700-32 5.2.4 Servicing of components Valve sections or directly mounted CAN-controls can be only serviced at HAWE facilities.

D 7700 CAN page 8 5.3 CAN-Bus-controls 5.3.1 General CAN-Bus (controller Area Network) is asynchronous, serial bus system where only two lines are needed for the data transmission. Twisted-pair cables with a characteristic impedance of 108 to 132 Ω are recommended as bus line (acc. to ISO 11898-2 "High speed medium Access Unit"). The following protocols are common for data transmission formats: CANopen 2.0 A & B and J1939, based either on 11 or 29 bits address data. 5.3.2 Lay-out of CAN-Bus systems A linear network topology should be employed and tap lines avoided if possible. When tap lines are necessary, their length should not exceed the specifications in table 1. Shielding of the CAN-line can be neglected when only low EMC-load is anticipated. The CAN-line should be shielded with proper GND connection in case of long lines or EMC-contaminated surroundings. A suitable alternative in cable booms is a twisted arrangement of the bus lines. There must not be a potential shift between the individual CAN users. GND-lines of all CAN devices have to be sufficiently dimensioned and routed together to one single point. The permissible current rating for the socket is 10A. Take care that this max current rating of the socket is not exceed, when the bus line is patched through a CAN PSL/PSV valve bank i.e. when there are an input socket as well as an output socket. In general it is better to provide a separate power supply line for high load consumers. Transfer rate Bus length Max. length for tap lines 100 kbit/s 600 m 25 m 125 kbit/s 500 m 20 m 250 kbit/s 250 m 10 m 500 kbit/s 100 m 5 m 1000 kbit/s <20 m 1 m The power supply line and the CAN-Bus line is led from one to the next valve section via a internal line. The connection cable consists of four wires: Power supply (U bat, GND) and CAN-Bus (CAN High, CAN Low). The recommended terminating resistor can be neglected at short tap lines. 5.3.3 Valve knots as Plug&Play slave with type PLVC A Plug&Play-configuration can be used for CAN-knots to provide an extended output level with the HAWE controls type PLVC. These external valve outputs can be maintained via the operating system of the PLVC like the apparent valve outputs, without necessity of communication with the application program. The following is mandatory for addressing to maintain Plug&Play-functionality: The valves connected to the external outputs and controlled via CAN-Bus have to be addressed with CAN Node-IDs > 32, all other communication together with the corresponding monitoring and safety functions are maintained by the PLVC. Individual valves are addressed with consecutive indices >2000. The indices of double valves can be calculated by 2000 + 2 n ' (n = section No.). Section No. n PLVC ID Knot ID Ref. COB ID Act. COB ID 1 2000 32 0x220 0x1A0 2 2002 34 0x222 0x1A2 3 2004 36 0x224 0x1A4 4 2006 38 0x226 0x1A6 5 2008 40 0x228 0x1A8 6 2010 42 0x22A 0x1AA 7 2012 44 0x22C 0x1AC 8 2014 46 0x22E 0x1AE 9 2016 48 0x230 0x1B0 10 2018 50 0x232 0x1B2

D 7700 CAN page 9 5.4 Basic lay-out Components Cover internal BUS Socket for controls / power supply Housing of the valve controls Optional: Socket for additional valve bank / CAN-user Solenoids