Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Similar documents
Instruction and Installation Guide

SIGNAL WORDS QUALIFIED PERSON

Vacuum Circuit Breaker (Vehicle)

Vacuum Circuit Breakers (Vehicle)

Installation Instructions For Motor Control Center (MCC) Units

Vacuum Circuit Breakers (Vehicle) Type HKR 7.5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9928C

Vacuum Circuit Breakers (Vehicle)

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

IB PowlVac ITE-HK Remote Racking Device

Vacuum Circuit Breakers (Vehicle) Type MSV 5kV. Instructions Installation Operation Maintenance SGIM-9988

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9968

Vacuum Circuit Breakers (Vehicle)

Vacuum Circuit Breakers (Vehicle)

Vacuum Circuit Breakers (Vehicle)

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

Cradle Mounted Key Interlock Guide Frame Accessory

Vacuum Circuit Breakers (Vehicle)

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

RGZESDI Inverter Duty AC Induction Motors

Effective November 2016 Supersedes September 1998 (S )

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. August, 2012

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

February 28 th, 2018 UPDATE: Important Product Safety Bulletin Immediate Action Required INSTRUCTIONS FOR FIELD RISK MITIGATION

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Quik-Spec Coordination Panelboard

SecoVac * Ground & Test Device

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Instruction sheet WARNING. October, 2014

Figure 1. Kearney Type HX cutout.

Factory Authorized Mechanism Enhancement (FAME)

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Effective November 2016 Supersedes February 2012 (S )

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Not all Low Voltage Switchgear is created equal

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

GE CONSUMER & INDUSTRIAL

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Effective March 2015 Supersedes S August 2012

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Design Standard. Purpose: Design Standard:

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

Not all Low Voltage Switchgear is created equal

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Effective June 2016 New Issue

Design Guide for Integration of Fixed-Mount Circuit Breakers

BUSWAY Low Voltage (Pow-R-Flex)

Type 3AH kv to 38 kv vacuum circuit breaker operator module instruction manual

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

TIASTAR Motor Control Center Installation And Maintenance Instructions For Units Only

TYPE AST. Grounding Switch. ALL Ratings INSTALLATION & INSTRUCTION MANUAL

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. September, 2017

The safest, most reliable Switchgear in the market today

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Power/Vac Switchgear Concepts And Basic Configurations

Effective May 2017 Supersedes December 2004 (S )

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Galaxy VM. Battery Breaker Box Installation 09/

Type GM-SG 5 kv and 15 kv non-arc-resistant metal-clad switchgear instruction manual

Introduction. Features. Intelligent Technologies Motor Control Center Structures

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Type 38-3AH3 38 kv vacuum circuit breaker instruction manual. Installation operation maintenance E50001-F710-A238-V1-4A00. Answers for energy.

ibusway for Data Center

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Transcription:

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear IMPORTANT The information contained herein is general in nature and not intended for specific application purposes. It does not relieve the user of responsibility to use sound practices in application, installation, operation, and maintenance of the equipment purchased. Siemens reserves the right to make changes in the specifications shown herein or to make improvements at any time without notice or obligations. Should a conflict arise between the general information contained in this publication and the contents of drawings or supplementary material or both, the latter shall take precedence. NOTE These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, the matter should be referred to the local Siemens sales office. The contents of this instruction manual should not become part of or modify any prior or existing agreement, commitment, or relationship. The sales contract contains the entire obligation of Siemens Energy & Automation, Inc. The warranty contained in the contract between the parties is the sole warranty of Siemens Energy & Automation, Inc. Any statements contained herein do not create new warranties or modify the existing warranty. 1

Table of Contents Introduction and Safety Introduction 2 Qualified person. 2 Signal words.. 2 Dangerous procedure. 2 Field Service Operation. 2 General Description Introduction 3 Scope... 3 General Description 3 Special Features Switchgear Rear.. 4 Switchgear Front. 4 Breaker Compartment 5 Auxiliary Compartment. 5 D-Compartment Breaker 5 Sill Channel 6 Installation Indoor Floor Plan Dimensions...7 2

Introduction and Safety Introduction Type 2B Arc Resistant WL low voltage switchgear is designed to meet all applicable UL, ANSI, NEMA and IEEE standards. It is designed and performance tested to ANSI C37.20.7 to provide an additional degree of protection from internal arc faults. Successful application and operation of this equipment depends as much upon proper installation and maintenance by the user as it does upon the careful design and construction by Siemens. The purpose of this Instruction Manual is to assist the user in developing safe and efficient procedures for the installation, maintenance and use of the equipment. This Instruction Manual acts a supplement to 11-C-9100-01: Instruction & installation guide for low voltage metalenclosed switchgear. Application of Arc Resistant Low Voltage Switchgear meeting the requirements of IEEE C37.20.7 does not eliminate the requirements of Personal Protection Equipment (PPE). Contact the nearest Siemens representative if any additional information is desired. clothing, etc., in accordance with established safety procedures. Training in rendering first aid. Signal Words The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates an imminently hazardous situation which if not avoided, will result in death or serious injury. Warning - Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution - Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Dangerous Procedures In addition to other procedures described in this manual as dangerous, user personnel must adhere to the following: 1. Always work on de-energized equipment. Always de-energize a breaker, and remove it from the switchgear before performing any tests, maintenance or repair. 2. Always discharge energy from closing and opening (tripping) springs before performing maintenance on circuit breakers. Qualified Person For the purpose of this manual and product labels, a Qualified Person is one who is familiar with the installation, construction and operation of the equipment and the hazards involved. In addition, this person has the following qualifications: Training and authorization to energize, deenergize, clear, ground and tag circuits and equipment in accordance with established safety practices. Training in the proper care and use of protective equipment such as rubber gloves, hard hat, safety glasses, face shields, flash 3. Always let an interlock device or safety mechanisms perform its function without forcing or defeating the device. Field Service Operation Siemens Industrial Services Division can provide the following support services for Type WL low voltage switchgear. Call 1-800-241-4453 to obtain additional information and schedule an appointment. Start-up and Commissioning Component and System Testing Maintenance (Scheduled and Preventative) Repair and Refurbishing On Site Operational Training 3

General Description Scope These instructions cover the installation and maintenance of Siemens Type 2B WL Arc Resistant metal enclosed low voltage switchgear assemblies, using the Type WL UL -1066 low voltage power circuit breakers. A typical indoor Type 2B WL arc resistant switchgear assembly is shown in Figure 1. Instruction and installation details of standard switchgear have already been discussed in 11-C- 9100-01 Rev.1. This manual discusses the special features and maintenance associated with arc resistant switchgear. Figure 1: Front view of Switchgear Introduction Siemens Type 2B Arc Resistant Metal-Enclosed Low Voltage Switchgear is designed to provide an additional degree of protection for personnel performing normal operating duties in proximity to the energized equipment. Such duties include opening or closing breakers, closed door racking of breakers, reading of instruments, or other such activities that do not require the opening of doors or removal of covers except doors or covers of compartments specifically identified as lowvoltage control or instrumentation compartments. It is designed and performance tested to ANSI C37.20.7 to provide an additional degree of protection from internal arc faults. General Description Type 2B Arc Resistant WL switchgear is an assembly of an indoor enclosure and mounting base with arc plenum. It has an insulated bus bar system, removable rear cover panels/doors secured with captive screws, section barriers and cable compartment barriers. Flame retardant barriers and shutters are provided in power circuit breaker compartments. One piece circuit breaker compartment doors with insert panels for fuses, indicating lights and control switches are used when required. A 39 inch minimum front aisle, a 36 inch minimum rear aisle and a 118 inch minimum ceiling height must be maintained for proper functioning of arc resistant switchgear. The arc resistant ratings are listed on the switchgear rating label. Ratings are given for: (1) Accessibility Type, (2) Arcing SHORT-CIRCUIT current and voltage, and (3) Arcing duration. This instruction manual acts as a supplement to 11-C-9100-01 Rev. 1: Instruction & installation guide for low voltage metal-enclosed switchgear. Should additional information be desired, including replacement instruction books, contact your Siemens representative. 4

Special Features Switchgear - Rear Top cover plate pressure relief flaps These flaps should be closed under normal conditions. The flaps open outward in the event of an arc fault to relieve internal pressure. The opening of flaps should not be blocked by cables or bus. A clear space of 22 must be maintained above the flaps. Rear cover pressure dams All the vents in the rear side of switchgear have pressure dam flaps installed inside. These flaps close in the event of arc fault to prevent arc gases from exiting the rear of the equipment. During normal operation the flaps should be open by 2 to 3 for venting. The flaps should not be modified, removed or blocked open. Figure 2: Rear Isometric view of Switchgear Enclosure & Rear Covers Reinforced enclosure to withstand pressure from internal arcing faults. Reinforced bolted rear covers/doors. Ensure that all screws are in place and tightened Switchgear - Front Enhancements Reinforced and gasketed front doors with additional hinges and latching means. Ensure that all doors are properly secured before placing gear in service. Shutters required in breaker compartments. If shutters are removed for servicing, they must be replaced before gear is placed back into service. The mounting base with integrated arc plenum must be installed under the switchgear. Figure 3: Front Isometric view of Switchgear 5

Special Features Breaker Compartment Breaker compartment parts Flame Retardant gap protection parts provide protection in the event of arc fault. These parts must be in place during normal operation. If they are removed during installation or servicing, they must be replaced before gear is reenergized. Auxiliary Compartment Figure 4: Front View of Breaker Compartment Auxiliary compartment parts Auxiliary bucket gap protection parts provide protection in the event of arc fault. Flame Retardant parts are attached on the back of metal gap protection parts. These parts must be in place during normal operation. If they are removed during installation or servicing, they must be replaced before gear is reenergized. Figure 5: Isometric view of Auxiliary Compartment Breaker Cradle Button Plug The button plug must be replaced after installing or servicing anchor bolt. This part must be in place during normal operation. Bottom Compartment Breaker C Figure 6: Isometric view of D-Compartment 6

Sill Channel Figure 7: Front view of Mounting Base Gap between Switchgear and Mounting Base The gap between the Mounting Base and the Switchgear must be closed after installation with silicone caulking compound. Silicone caulking compound is installed at the factory if the switchgear is shipped installed on the Mounting Base. If the Mounting Base is shipped separately, a tube of silicone caulking compound is furnished with the switchgear. SPACE LEFT INTENTIONALLY BLANK. 7

Installation Indoor Floor Plan Arc-Resistant Switchgear Cable space above and below for arc resistant switchgear is different from the standard LV switchgear. The details are as shown: A Equipment Depth Cable Direction B C D G Anchor Bolt Spacing 62.6 (1590) Below 20.00 (508) (1) 32.59 (828) Above 13.68 (347) 13.88 (353) 37.59 (955) 67.6 (1717) Below 20.00 (508) (1) 32.59 (828) (Fused) Above 13.68 (347) 18.88 (480) 37.59 (955) 72.6 (1844) Below 30.00 (762) (1) 32.59 (828) Above 23.68 (601) 13.88 (353) 37.59 (955) 77.6 (1971) Below 30.00 (889) (1) 32.59 (828) (Fused) Above 23.68 (728) 18.88 (480) 37.59 (955) 82.6 (2098) Below 40.00 (1016) (1) 32.59 (828) Above 33.68 (855) 13.88 (353) 32.59 (828) 82.6 (2098) Below 35.00 (889) (1) 37.59 (955) (Fused) Above 28.68 (728) 18.88 (480) 37.59 (955) 59.13 (1502) 64.13 (1629) 69.13 (1756) 74.13 (1883) 79.13 (2010) 79.13 (2010) Note: Dimensions shown in inches and ( mm ). Drawings are not to scale. (1) Space available for cables below is reduced by 5.20 inches when a lower neutral bus is present. (2) Space available for cables below is reduced by 4.00 if an 800-3200A breaker is located in the bottom compartment. Reductions per not es 1 & 2 are additive. Example: cables be low + lower neutral + 2000A breaker in bottom comp artment = B - 9.20. (3) 118 inches minimum room ce iling height is required for ventilation of arc products (4) 4.10 (104) if W=2 2; 4.60 (117) if W=32. 8

Siemens Industry, Inc. Building Technologies Division 5400 Triangle Parkway Norcross, GA 30092 For Technical Support: Call us at 1.800.241.4453 or Visit www.usa.siemens.com/powerdistribution For Nearest Sales Office: Call us at 1.800.964.4114 or Visit www.sea.siemens.com/sales/salesoffices.html 2010 Siemens Industry, Inc. All Rights Reserved Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. Order # LVIM-ARCII-0310 (Siemens Internal Part Number 11-C-9887-01 Rev. 1) 9