Impact of the Niigata Chuestu-oki Earthquake on the Tokyo Electric Power Company (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station and Countermeasures

Similar documents
Thursday 1 November. Friday 2 November

TEPCO NUCLEAR SAFETY REFORM PLAN PROGRESS REPORT 1 ST QUARTER FY 2014 EXECUTIVE SUMMARY

Current Status of Fukushima Daiichi Nuclear Power Station & Lessons Learned from Experiences of the Great East Japan

Seismic Damage Information (the 120th Release) (As of 15:00 April 29, 2011)

Seismic Damage Information (the 144th Release) (As of 15:00 May 20, 2011)

Fuel removal from the spent fuel pool at Fukushima Daiichi Nuclear Power Station Unit 3

Information (15:00), December 1, 2017

Masaru Takei - The Tokyo Electric Power Company, Inc. Executive Vice President

Japan s Decontamination Efforts and its Effects

Summary. IEEJ: November 2011 All Rights Reserved. Yu Nagatomi *

EARTHQUAKE ACTIVITY IN THE YELLOWSTONE REGION. Preliminary Epicenters. April 1 June 30, 2017

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

EARTHQUAKE ACTIVITY IN THE YELLOWSTONE REGION. Preliminary Epicenters. January 1 March 31, 2014

Fukushima Nuclear Accident Analysis Report <Summary Attachment> June 20, 2012 Tokyo Electric Power Company, Inc.

The Great East Japan Earthquake and Lessons Learned ~Oil and Electricity~

Terry Blackwell Page 1 of 5. Education North Carolina State University BS, Electrical Engineering Power Systems emphasis

Updated information of Fukushima Daiichi NPP. October Ki Sig Kang 1

AP1000 European 7. Instrumentation and Controls Design Control Document

PV in Japan and Utility s activities

FRM II Converter Facility

Report regarding Collection of Reports pursuant to the Provisions of Article 106, Paragraph 3 of the Electricity Business Act

Fukushima Daiichi Accident Technical Causal Factor Analysis

Factbook. Tokyo Electric Power Company Holdings, Inc. August Tokyo Electric Power Company Holdings, Inc. All Rights Reserved.

Section 5. Crude Oil and Natural Gas Resource Development

Appendix G Examples and Recommended Methods

Next Phase of Fukushima Daiichi D&D (Enhanced institutional and technical efforts by Team Japan )

Earthquake & Smart Society

Utilization of Probe Vehicle Information in Disasters in Japan

An Overwhelmingly Solid and Advantageo

April 25, 2013 FOR IMMEDIATE RELEASE

Inventing a new type of platform gate

ADB Knowledge Partnership Week. Hirokazu Yamaguchi May, 2015

Georgia Drycleaner Compliance Calendar

Worcester Public Schools Student Transportation Contract Proposed Bid Specification Change Summary Sheet

Fukushima Daiichi Status Report 27 July 2012

Evaluating Stakeholder Engagement

Consumer Guidelines for Electric Power Generator Installation and Interconnection

US Japan Energy Opportunities. May 15, 2013 NEDO Silicon Valley Office Osamu Onodera

Statistics on Radiation Exposure Doses of Decontamination Workers and Other Items

Presented at SC-2, Meeting October 5-6, 2010,, Seattle, WA

Delaware Electric Cooperative

CSR Report Highlight CSR

Current State of the Renewable Energy in Kyushu Electric Power and Our Future Plan. Kyushu Electric Power Co. Inc. June 8, 2017

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2017 RELIABILITY SCORECARD

Chemical decontamination in nuclear systems radiation protection issues during planning and realization

Smart Grid Automation and Centralized FISR

Emerald People s Utility District RATE SCHEDULES. Rate Schedules Effective April 1, 2018

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Treatment of Uranium Slugs at the CEA Marcoule site 12026

ECE/RCTE/CONF/4/Add.1/Rev.2

City of Palo Alto (ID # 6416) City Council Staff Report

POWER SYSTEM OPERATING INCIDENT REPORT MULTIPLE CONTINGENCY EVENT IN NORTH WEST TASMANIA ON 6 APRIL 2012

POWER SYSTEM OPERATING INCIDENT REPORT SIMULTANEOUS TRIP OF 5A6 MT PIPER BANNABY 500 KV LINE AND MT PIPER NO. 2 UNIT ON 9 FEBRUARY 2012

A Guide to the medium General Service. BC Hydro Last Updated: February 24, 2012

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD

Wholesale Developer Services Charges

INSTITUTE FOR SCIENCE AND INTERNATIONAL SECURITY

Project X: Challenge to attain Zero Standby Power

STANDARD OPERATING PROCEDURES FIRE STATION MANAGEMENT FIRE HYDRANT MAINTENANCE EFFECTIVE: OCTOBER 2007

RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS NOT USED IN THE HEALING ARTS

Nuclear L.L. C. 10 CFR 50.55a

Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System

Development of Compact & High Efficiency Polymer Electrolyte Fuel Cell System for Enclosed Spaces

ELECTRICAL GROUNDING SAFETY PROGRAM

Gleason Phoenix 450 Project

RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER

SUNY GENESEO ENVIRONMENTAL HEALTH & SAFETY

Deploying Smart Wires at the Georgia Power Company (GPC)

Argo National Data Management Report Italy (2018) - MedArgo

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Core Components for Large-scale PV Generation Systems

EXHIBIT A ORDINANCE NO. O CITY OF LAURINBURG, NORTH CAROLINA SCHEDULES OPR RESIDENTIAL TIME-OF-USE SERVICE

Abstract In this paper, we developed a lateral damper to improve the running safety of railway vehicles

RULE 2260 REGISTRATION FOR EQUIPMENT SUBJECT TO CALIFORNIA S GREENHOUSE GAS OIL AND GAS REGULATION

Case study: Utility-scale battery for balancing power in Germany

Cost Reflective Tariffs

Japanese Energy Industry Transformation

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

Downtown Lee s Summit Parking Study

ABB's Energy Efficiency and Advisory Systems

Tank Farm Additional Storage Site Layout

Solar*Rewards Community Engineering Frequently Asked Questions For Garden Operators Minnesota

PART I RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS

Hartlepool power station June 2018 monthly report

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

WIPP Update. Jeffrey Carswell, Deputy Manager. Carlsbad Field Office Office of Environmental Management

HCSIS, Independent Monitoring for Quality (IM4Q) - Considerations. Date: 07/20/2011

Audit Follow-up. Fleet Fuel Operations (Report #0801, Issued October 18, 2007) As of March 31, Summary. Report #0811 June 20, 2008

North Dakota Commercial and Industrial Electric Prices

2 nd. Monitoring period: 01/01/ /12/2011. Version 2.0. June 20, Climate Bridge Ltd.

POWER SYSTEM INCIDENT REPORT: TRIP OF NO 1 AND 2 NEW OSBORNE 66 KV BUSBARS ON 26 SEPTEMBER 2010

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Spillage from a semi-buried jet fuel tank 30 December, 2005 Sainte-Marie [Reunion Island] France

<Nationwide> Improving moderately ( )

IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA TEL: IMT PART NUMBER

Revision 4, Maine Yankee s License Termination Plan

Worker Crushed by Vessel Date of Incident: August 3, 2007 Type of Incident: Fatal

Per Meter, Per Month. Effective July 1, 2018 Customer Charge Flat Charge $8.86

Creating a Lean and Productive Processing Facility

QUARTERLY REVIEW OF BUSINESS CONDITIONS: MOTOR VEHICLE MANUFACTURING INDUSTRY / AUTOMOTIVE SECTOR: 4 TH QUARTER 2016

POWER SYSTEM OPERATING INCIDENT REPORT TRIP OF 220 KV C BUSBAR AT GORDON POWER STATION ON 26 NOVEMBER 2011

Transcription:

Impact of the Niigata Chuestu-oki Earthquake on the Tokyo Electric Power Company (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station and Countermeasures September 2007 The Tokyo Electric Power Company, Inc. 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 1

1. Status of the Kashiwazaki-Kariwa Nuclear Power Station Units 2,3,4, and 7 automatically shutdown when the earthquake occurred. All 7 units, with a total capacity of 8210 MW, are in a stable shutdown condition. Upon inspection, no damage to components of high safety significance was detected. Damage mainly occurred to facilities with low seismic safety significance. 2,555 non-conformances were confirmed upon inspection, including the following 10 incidents subject to reporting according to decrees and safety agreements as of August 30 th : Leakage of water including radioactive material at Unit 6 (1 incident) Water spillage from the spent fuel pool onto the floor at Units 1 7 (7 incidents) House Transformer fire at Unit 3 (1 incident) Drive Axis Coupling breakage of the Unit 6 ceiling crane (1 incident) Visual inspection has been completed and an in-depth investigation is now in progress. In-core inspection of unit 1 started from August 21 st. No change has been observed in the monitoring post data since the occurrence of the earthquake; hence no radiation effect to the environment Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 2

2. Earthquake-related Issues (1) [Unit 3 House Transformer Fire] [Time Line] July 16 10:13 Earthquake occurs 10:15 Post-earthquake plant walk-down discovers the fire. Initial efforts to extinguish the fire (4 people). 10:27 Shift supervisor contacts the fire department but was asked to use in-house self defense fire brigade. 11:23 Shift supervisor contacts the fire department again. 11:27 The fire department enters the Kashiwazaki-Kariwa NPS. 12:10 Fire is extinguished. [Status of Damage & Causes] Water could not be sprayed from the fire hydrant due to pipe breakage. Since oil fire was suspected and difficult to extinguish with water, the workers retreated to a safe area, reported to the emergency H/Q and waited for the arrival of the fire department. The fire protection wall prevented the fire from spreading to other areas. Soil deformation is presumed to have caused a short circuit. An in-depth investigation is in progress. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 3

2. Earthquake-related Issues (1) [Unit 3 House Transformer Fire] fire protection wall Unit 3 turbine building Subsidence of the connection bus of the secondary side of the transformer relative to the transformer itself. fire protection wall House Transformer Connection bus Secondary side duct Subsidence of connection bus Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 4

2. Earthquake-related Issues (2) [Release of Radioactive Material into the Sea from Water Leakage at Unit 6] [Time Line] July 16 12:50 Identification of water puddles in the noncontrolled area of the reactor building. 18:20 Small amount of radioactivity in the puddles confirmed. 20:10 Leakage of radioactive water into the sea via the water discharge outlet confirmed. 21:45 Press release. Since the water puddle was in the noncontrolled area with an amount below reporting level, it was initially considered unnecessary to report to the authority. Afterwards, a sample was taken to detect radioactivity. Discharge was confirmed by checking possible discharge routes, operational history of the pump, and sampling and measurement of the water tank. Discharged water: 1.2m 3 Amount of Radioactivity: 9 x 10 4 Bq Radiation Dose from the above radioactivity: 2 x 10-9 msv (1/1,000,000,000 of the radiation an average person is exposed to from natural sources annually.) [Cause] It is presumed that water sloshed onto the floor from the spent fuel pool and flowed along the electric cable conduit to the non-controlled area. (There are currently no leaks). Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 5

Unit 6 Reactor Building 2. Earthquake-related Issues (2) [Release of Radioactive Material into the Sea from Water Leakage at Unit 6] Non-Controlled Area Controlled Area Water sloshed out of the spent fuel pool due to the earthquake. Electric cable conduit Leakage from the refueling machine cable. Spent Fuel Pool Sea Discharge pump has not operated since July 16 th and hence no more discharge. Cable penetration Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 6

2. Earthquake-related Issues (3) [Radioactive Materials Detected from the Unit 7 Main Stack Monitor] [Time Line] July 17 13:00 Iodine and radioactive particulate material (Cr-51, Co-60) were detected during weekly periodic measurement of the main exhaust stack. 16:00 Press release. Total radioactivity: 4x10 8 Bq Radiation Dose from the above radioactivity: 2 x 10-7 msv (1/10,000,000 of the radiation an average person is exposed to from natural sources annually.) [Cause] It is presumed that radioactive materials were sucked out from the condenser and subsequently released from the main stack due to the delay in shutting down the gland steam ventilator after automatic shutdown of the reactor. No radioactive material has been detected in measurements after July 19. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 7

2. Earthquake-related Issues (3) [Radioactive Materials Detected from the Unit 7 Main Stack Monitor] Reactor Building reactor Turbine Building Turbine conden ser ventilation Turbine gland steam ventilator Continued operation after plant shutdown Filter Filter Exhaust Stack Monitoring room of the Unit 7 Main Exhaust Stack Charcoal noble gas hold up equipment Steam from main turbine To condenser To gland steam ventilator Gland steam Gland packing atmosphere Main turbine axis Normal Operation Steam from main turbine To gland steam ventilator No gland Gland packing steam atmosphere Main turbine axis Situation After the Quake Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 8

3. Status of Other Generation Facilities Several hundred drums containing low-level waste in the solid waste storage warehouse tipped over. Access road in the site. (Close to the Unit 5 water discharge outlet.) Displacement of exhaust duct. Breakage found on the coupling of the drive axis of the Unit 6 reactor building ceiling crane. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 9

4. Improvement Issues Based on METI s order on July 20, an improvement plan was submitted on July 26. Reinforcement of the Self-Defence Fire Brigade Establish a 24-hour fire-fighting crew. Deploy a chemical fire engine. Secure an exclusive communication line with the fire department. Chemical Fire Engine & Technical Specialists Establish a prompt and accurate accident reporting system Set-up a radiation measurement organization for nights and holidays. Enhance the emergency support center including securing reliable communication facilities. Report the possibility of radioactive material leakage at the time confirmed. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 10

5. Provision of Information to the Local Community [Correspondence with the Media] Press release made daily on the status of the NPS since the earthquake occurred (about 80 times). Press conferences with the Superintendent of the NPS. (7/20, 8/2, 8/10) NPS opened to the Press. (7/21, 7/25, 7/28, 8/15, 8/28) [Transmission of Information to Local Residents] Newspaper ad on apology by the TEPCO president and update on the status of the NPS.(7/24, 7/27, 8/10) Multiple daily radio broadcasts regarding the status of the NPS. Distribution of newspaper inserts (7/26, 8/2, 8/9, 8/14, 8/23, 8/24, 8/30 roughly 39,000 copies). TEPCO employees had distributed to 60 Kashiwazaki-Kariwa evacuation centers. From July 16, TEPCO employees paid explanatory visits to over 950 people such as local politicians, the Fisheries Cooperative, Chamber of Commerce and Industry, and heads of local communities. Earthquake information was consolidated and posted on the company website. Posting of apology by the Superintendent of NPS and plant status at the TEPCO Public Relations center. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 11

6. Next Actions (1) [Inspection & Restoration] Upon visual inspection on major components, no significant damage was detected. In-depth investigation on the structural soundness of equipments is now in progress. With ongoing in-depth investigation, damaged facilities would be restored in series. Analytical verification and in-depth investigation by experts would be done on the components of high safety significance. In-core inspection of upper part of the unit 1 reactor completed on August 23rd. No damage was found. Inspection Schedule of Unit 1 Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 12

6. Next Actions (2) Seismic Safety Verification Analyze the observation data. Conduct geological surveys including sea and land areas around the site. Conduct seismic safety verification for safety significant equipments based on seismic motion derived from analyses. Take necessary countermeasures based on the results of the seismic safety verification. Submitted the Revision of the Seismic Safety Assessment Execution Plan to METI on August 20. Though a seismic safety assessment was in progress based on the former plan submitted to METI in October 2006, due to the earthquake, METI ordered TEPCO to revise the plan. The revision was carried out and submitted to METI. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 13

[Outline of the Geological Survey to be Conducted at Kashiwazaki-Kariwa] 6. Next Actions (3) Investigation and verification of active faults in the sea area surrounding the Kashiwazaki-Kariwa NPS. <Sonic Prospecting in the Sea Area> From August 27 th, 2007 to the end of October, 2007. Investigation and verification of active faults in the land area surrounding the Kashiwazaki-Kariwa NPS. <Subsurface Prospecting> <Surface Geological Survey> From the beginning of September, 2007 to the end of March, 2008. Investigation and verification of subsurface structure and ground quality including deep areas on the premises. <Boring/Geophysical Survey> From the beginning of September, 2007 to the end of March, 2008. About 140 km parallel to the coastline. About 50 km offshore. Faults/Active Faults Land Area Survey Range Sea Area Survey Range On-site Survey Range Kashiwazaki-Kariwa NPS Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 14

7. Forecast of Electric Demand and Supply (1) Initial Forecast of Electric Demand and Supply (August) Estimated Maximum Demand 61,100MW 35.3ºC Forecast of Supply (Monthly Average Supply Before the Earthquake : 65,270 MW Reduction by the Earthquake : - 7,260 MW Additional Supply Measures* : + 4,740 MW Total Supply Capacity : 62,750 MW * Additional Supply Measures Output increase : 2,360MW The power provided by other companies for emergency support : 1,660MW Purchase of electricity from In-house power generation : 720MW ( kw) 6,600 6,400 6,200 6,000 5,800 5,600 5,400 5,200 5,000 Reduction by the Earthquake Additional Supply Measures Initial Forecast of Electric Demand and Supply(August) Supply Before the Earthquake Total Supply Capacity Estimated Maximum Demand In case of ordinary summer heat, supply would be enough to cover demand. However, in case of a severe heat wave, we will secure stable supply by exercising measures such as calling our customers for more electricity conservation, reducing demand based on load management contracts (about 1,270MW), and utilizing the Shiobara Power Station (900MW) of which we acquired permit on an emergency and temporary usage. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 15

7. Forecast of Electric Demand and Supply (2) Situation of Maximum Demand on August 22nd Maximum Demand 61,470MW (37ºC Tokyo) <Major Emergency Measures> Demand reduction based on load management contracts : 140MW The contracts were set in motion since 1991, 17 years since the last one. Requested 23 customers to reduce their demand. Supply Capacity 64,000MW (reserved power 2,530MW, 4.1%) <Major Emergency Measures> Power provided by other utilities for emergency support : 1,500MW (From Hokkaido, Tohoku, and Chubu Electric Power Company) Emergency and temporary use of Shiobara Power Station (900MW) MW 64000 63000 62000 61000 60000 Load Management Contracts 140 Shiobara 900 Other utilities 1500 6147 kw Demand 6400 kw Supply (61,470MW) (64,000MW) Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 16

8. Request to Save Electricity in the Tokyo Metropolitan Area Broadcasting Denki Yoho an electricity demand forecast of TEPCO s supply areas on TV and Radio. Posting Denki Yoho on the TEPCO website. Insertion of Request to Save Electricity in newspapers. (Distribution of 16 million issues in the Tokyo Metropolitan Area on August 1st) Broadcasting Request to Save Electricity on TV and Radio from August 1 st. Distribution of leaflets to every customer by meter readers. 8/22 Denki Publicize saving electricity through the distribution of leaflets and goods. Yoho Display posters on saving electricity. Individual visitation to extra-high-voltage/high-voltage customers of over 500kW and to their head offices. Sending direct-mailers to industry groups. Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 17

( Reference 1) Earthquake Overview Date & Time of the Quake: July 16, 2007 10:13 AM Kashiwazaki-Kariwa NPS Source: Offshore of Kami- Chuestu-oki Region in Niigata Prefecture Latitude: 37 N Longitude: 138 E Depth: 17 km Magnitude M=6.8 Distance of NPS from: Epicenter: 16 km Source: 23 km Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 18

(Reference 2) Observed Seismic Data Observed seismic motion largely surpassed the design-basis seismic motion. Observed maximum acceleration at each unit / design-basis response acceleration in brackets. Observation Area North-South Direction East-West Direction Vertical Unit 1 311(274) 680(273) 408(235) Unit 2 304(167) 606(167) 282(235) Unit 3 308(192) 384(193) 311(235) Unit 4 310(193) 492(194) 337(235) Unit 5 Unit 6 Unit 7 277(249) 271(263) 267(263) 442(254) 322(263) 356(263) 205(235) 488(235) 355(235) Seismograph Measured by the base mat of each reactor building. Unit of Measurement: (Gal) The base of the turbine in Unit 3 experienced the largest acceleration of 2058 Gal in the East-West direction (2.5 times the design-basis acceleration of 834 Gal). Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 19

(Reference 3) Actual Record of Demand and Supply Supply Capacity (Weekly) Left Axis Maximum Demand this summer 61,470MW Maximum Demand & Supply Capacity 10MW Highest temperature in Tokyo Right Axis Maximum Demand Left Axis Highest Temperature Date Status of Kashiwazaki-Kariwa NPS as of August 30, 2007 2007 The Tokyo Electric Power Company, Inc. All Rights Reserved. 20