17429X.00 SERIES MODELS:

Similar documents
DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

PWP Series USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP PWP101-2 PWP101-5 PWP

USER S MANUAL

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

USER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors

MM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

USER S MANUAL. Variable-frequency drives for 3-phase and single-phase AC motors

User s Manual MMVFD SERIES MODEL: MMVFD06-D230AC. Variable-frequency drives for 3-phase AC motors

MHS Series USER MANUAL MHS MHS MHS MHS443-10

VFD Series USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC.

CONTROL FEATURES AVAILABLE OPTIONS

Excel [XL] Series USER S MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

MM03-PCM MM10-PCM. User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

Boston Gear Ratiotrol DC Motor Speed Control

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

BC141, BC142, BC142-5 & BC142-6 DC Control


Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

Installation & Operation Manual

PowerOhm Installation Manual for LG ATV Series Braking Modules

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Installation and Operation Manual. *See page 6 for CE Information

PowerOhm Installation Manual for BM R Series Braking Modules

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

KBVF Adjustable Frequency Drive

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Boston Gear Ratiotrol

Boston Gear Ratiotrol DC Motor Speed Control

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

Fincor Series 2230 MKII/2240

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

DC Variable Speed Drive Panel

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

PowerOhm Installation Manual for BM R Series Braking Modules

SAFTRONICS DF8 PLUS SERIES

Boston Gear Ratiotrol

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

KBMD-240D MULTI-DRIVE

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Filtered PWM Speed Control for Permanent Magnet DC Motors

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

TABLE OF CONTENTS STANDARD FEATURES

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

CABINET REEL OPERATING INSTRUCTIONS

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

Boston Gear Ratiotrol

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

CABINET REEL OPERATING INSTRUCTIONS

Model 1000AR INSTALLATION AND OPERATION. Regenerative Brushless DC Motor Control INSTRUCTION MANUAL

KBIC SCR DC Motor Speed Controls

MaxPak Plus Analog DC V S Drive

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

Installation and Operating Manual

Dayton DC Motor Control

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

MDC Series

Installation and Operation Manual

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

MDC Series

5001TCP SPEED CONTROLLER

Series 5 Inverter NEMA 4X, IP-65 Installation and Operating Manual

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Type ABL-3905 and ABL Volt Brushless DC Motor Controls

DORNER Conveyor Speed Control

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Transcription:

LEESON ELECTRIC MOTORS, GEARMOTORS AND DRIVES R User s Manual 17429X.00 SERIES MODELS: 174298.00 174299.00 PWM REGENERATIVE DC TO DC DRIVES

II Table of Contents 17429X.00 Drives............................................................... IV Regenerative Drives..............................................................V Specifications................................................................... 1 Dimensions..................................................................... 2 Installation...................................................................... 3 Mounting..................................................................... 3 Shielding guidelines............................................................ 4 Speed adjust potentiometer...................................................... 5 Logic Connections............................................................. 5 Heat Sinking.................................................................. 7 Connections.................................................................. 7 Fuse........................................................................ 8 Wiring....................................................................... 9 Contactor Connections (Optional)................................................ 10 Operation..................................................................... 12 Before applying power......................................................... 12 Startup and Shutdown......................................................... 12 Starting and stopping methods................................................... 13 Automatic restart upon power restoration........................................... 13 Line starting and line stopping................................................... 13 Enable/Brake/Direction......................................................... 14 Voltage follower.............................................................. 15 Calibration..................................................................... 16 MINIMUM SPEED (MIN SPD)................................................... 17 MAXIMUM SPEED (MAX SPD).................................................. 17 ACCELERATION (ACCEL)...................................................... 17 DECELERATION (DECEL)...................................................... 18 IR COMPENSATION (IR COMP)................................................. 18 MOTOR CURRENT LIMIT ()........................................... 19

III REGENERATIVE CURRENT LIMIT ().................................... 19 Application Notes............................................................... 22 Multiple fixed speeds.......................................................... 22 Adjustable speeds using potentiometers in series.................................... 23 RUN/JOG Switch............................................................. 24 Troubleshooting................................................................ 25 Before troubleshooting......................................................... 25 Status LEDs................................................................. 26 Illustrations Figure 1. Four Quadrant Operation...................................................V Figure 2. 174298.00 and 174299.00 Dimensions........................................ 2 Figure 3. TB501 Connections....................................................... 5 Figure 4. Speed Adjust Potentiometer................................................ 6 Figure 5. Speed Adjust Potentiometer Connections...................................... 6 Figure 6. Motor and Battery Connections.............................................. 8 Figure 7. Optional Coil Connections................................................. 10 Figure 8. Optional Contactor Connections............................................ 11 Figure 9. Open Collector Input..................................................... 14 Figure 10. Voltage Follower Connections............................................. 15 Figure 11. Calibration Trimpot Layout................................................ 16 Figure 12. Approximate and Settings............................. 20 Figure 13. Approximate and Settings............................. 21 Figure 14. Multiple Fixed Speeds................................................... 22 Figure 15. Adjustable Fixed Speeds Using Potentiometers in Series........................ 23 Figure 16. RUN/JOG Switch Connection to Speed Adjust Potentiometer.................... 24

IV 17429X.00 Drives Leeson s 17429X.00 Series drives are four-quadrant regenerative PWM drives for low voltage applications. These open chassis drives come with the following features: PULSE WIDTH MODULATION Lower form factor than SCR drives (1.01 versus 1.37) throughout the motor speed range. Motor runs quieter, with greater efficiency and less maintenance. FOUR QUADRANT REGENERATIVE OPERATION See the Regenerative Drives section. REGENERATIVE BRAKING No contactors required. No electromechanical components to overheat or wear out. ENABLE / BRAKE / DIRECTION TERMINALS Choose a function by simply opening or closing a dry contact or through an open collector transistor. STATUS LEDs Power and Fault LEDs provide a visual status of the drive. OVER TEMPERATURE PROTECTION Drive will fold the output power back to prevent from overheating. Drive will fault if it still remains too hot. MICROPROCESSOR BASED Allows for factory programming of 17429X.00 drives for custom drives designed for OEMs.

Regenerative Drives V Most non-regenerative variable-speed DC drives control current flow to a motor in one direction. The direction of current flow is the same direction as the motor rotation. Non-regenerative drives operate in Quadrant 1, and also in Quadrant 3 if the drive is reversible (See Figure 1). Motors must stop before reversing direction. Unless dynamic braking is used, non-regenerative drives cannot decelerate a load faster than coasting to a lower speed. Regenerative drives operate in two additional quadrants: Quadrant 2 and Quadrant 4. In these quadrants, motor torque is in the opposite direction of motor rotation. This allows regenerative drives to reverse a motor without contactors or switches, to control an overhauling load, and to decelerate a load faster than it would take to coast to a lower speed. MOTOR ROTATION MOTOR TORQUE NOTE: ARROWS IN SAME DIRECTION = MOTOR ACTION ARROWS IN OPPOSITE DIRECTION = REGENERATIVE ACTION Figure 1. Four Quadrant Operation

Specifications 1 MODEL 174298.00 174299.00 MAX ARMATURE 1 MIN. PEAK ARMATURE MAX ARMATURE DC INPUT VOLTAGE CURRENT (AMPS DC) 120* 100** CURRENT (AMPS DC) 250 240 VOLTAGE (VDC) 12 or 24 1 36 or 48 1 RANGE (VDC) 10-32 20-62 Acceleration Time Range 0.2-20 seconds Deceleration Time Range 0.2-20 seconds Analog Input Voltage Range (Signal Common must be same as battery common) 0-5 VDC Input Impedance (S1 to S2) 520 K Speed Regulation 1% Speed Range 100:1 Form Factor 1.01 Ambient Operating Temperature Range 0 C - 40 C Weight 174298.00 2.25 lbs 174299.00 2.25 lbs Vibration 0.5G max (0-50 Hz) 0.1G max (>50 Hz) * Derate by 15% when mounted horizontally. ** Derate by 20% when mounted horizontally. 1 0-100% of Input Voltage.

2 Dimensions Figure 2. 174298.00 and 174299.00 Dimensions

Installation Mounting m WARNING Do not install, rewire, or remove this control with input power applied. Doing so may cause damage or serious injury. Make sure you have read and understood the Safety Warnings section before attempting installation. Drive components are sensitive to electrostatic fields. Avoid contact with the circuit board directly. Hold drive by the chassis only. Protect the drive from dirt, moisture, and accidental contact. Provide sufficient room for access to the terminal block and calibration trimpots. Mount the drive away from other heat sources. Operate the drive within the specified ambient operating temperature range. Keep 2 of clearance on each side of the drive and 4 of clearance above and below the drive. Prevent loose connections by avoiding excessive vibration of the drive. Mount drive with its heat sink in a vertical plane. Four 0.19 in. (5 mm) wide slots in the chassis accept #8 pan head screws. If heat sink is mounted horizontally then derate the drive as specified in Specifications section.

4 Shielding guidelines m WARNING Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls. As a general rule, Leeson recommends shielding of all conductors. If it is not practical to shield power conductors, Leeson recommends shielding all logic-level leads. If shielding of logic level leads is not practical, the user should twist all logic leads with themselves to minimize induced noise. It may be necessary to earth ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield. If the drive continues to pick up noise after grounding the shield then mount the drive in a less noisy environment. Logic wires from other input devices, such as motion controllers and PLL velocity controllers, must be separated from power lines in the same manner as the logic I/O on this drive.

Speed adjust potentiometer m WARNING Be sure that the potentiometer tabs do not make contact with the potentiometer enclosure. Mount the speed adjust potentiometer through a 0.38 in. (10 mm) hole with the hardware provided (see Figure 4). Install the circular insulating disk between the panel and the 10K ohm speed adjust potentiometer. Twist the speed adjust potentiometer wire to avoid picking up unwanted electrical noise. If speed adjust potentiometer wires are longer than 18 in. (457 mm), use shielded cable. Keep speed adjust potentiometer wires separate from power leads (BAT +, BAT -, A1, A2). Logic Connections Figure 3. TB501 Connections

MOUNT THROUGH A 0.38 IN. (10 MM) HOLE CW WIPER CCW NUT STAR WASHER PANEL INSULATING DISK SPEED ADJUST POTENTIOMETER POT TAB ASSIGNMENTS Figure 4. Speed Adjust Potentiometer Figure 5. Speed Adjust Potentiometer Connections

7 Heat Sinking 174298.00 and 174299.00 drives are pre-mounted on a heat sink. For optimum heat transfer, mount the drive with heat sink fins standing vertically. Connections m WARNING Do not initially connect this equipment with power applied. Failure to heed this directive may result in damage or serious injury. Leeson strongly recommends the installation of a master power switch in the voltage input line, as shown in Figure 6. The switch contacts should be rated at a minimum of 150-200% of motor nameplate current and 150% of the input voltage. Motor Leeson drives supply motor voltage from A1 and A2 terminals. It is assumed throughout this manual that, when A1 is positive with respect to A2, the motor will rotate clockwise (CW) while looking at the output shaft protruding from the front of the motor. If this is opposite of the desired rotation, simply reverse the wiring of A1 and A2, or close the direction terminals on TB501. Connect a DC motor to terminals A1 and A2 as shown in Figure 6. Ensure that the motor voltage rating is consistent with the drive s output voltage. Power Input m WARNING This drive is not diode-protected from reverse battery voltage. You must assure that POS (+) is wired to BAT+ and NEG (-) is wired to BAT-. Connect the DC power leads to terminals BAT+ and BAT-, or to a single-throw, single-pole master power switch as shown in Figure 6 (recommended).

8 Fuse Wire a power input fuse between the stop switch (if installed) and the BAT+ terminal on the circuit board. The fuse should be rated at 150% of input voltage and 150-200% of maximum motor nameplate current. An example of a fuse we recommend would be Cooper Bussmann AMG-125, AMG-150, AMG-175, or AMG-200. Figure 6. Motor and Battery Connections

9 Wiring m WARNING Do not install, remove, or rewire this equipment with power applied. Failure to heed this warning may result in damage, explosion, or serious injury. To prevent the risk of injury or fatality, avoid direct contact with the printed circuit board or with circuit elements. Do not disconnect any of the motor leads from the drive unless power is removed. Opening any one motor lead may destroy the drive. This drive is not diode-protected from reverse battery voltage. You must assure that POS (+) is wired to BAT+ and NEG(-) is wired to BAT-. Use 18 AWG wire for speed adjust potentiometer wiring. Size the DC voltage input and motor wire according to the following chart: Table 1. Wire Gauge / Length Chart Maximum Wire Length (feet) Wire Gauge (AWG) Armature Current (amps) 8 10 10 10 10 10 14 10 8 6 4 3 0-19 20-32 60 80 100 120

10 Contactor Connections (Optional) A contactor may be connected between the battery and the drive as shown in Figure 8. The contactor and precharge circuit allow the drive to be soft charged which helps prevent sparking when the battery is being connected to the drive. Another advantage of using the contactor is that it serves as an additional safety device to protect against a run away condition, some cases of reverse polarity battery connection, and excessive charging voltages. Once the drive is enabled, the coil output will energize and the contactor will close. The contactor s coil voltage must be the same voltage rating as the battery supply to the drive. The COIL+ can source up to 1 Amp. See Figures 7 and 8 for wiring information. An example of a contactor we recommend would be White Rogers 586 or 124 type. Leave COIL+ and COIL- open if a contactor is not used. DO NOT place a jumper across COIL+ and COIL-, doing so will damage the drive. Figure 7. Optional Coil Connections

11 Figure 8. Optional Contactor Connections

12 Operation m WARNING Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. BE ALERT. High current can cause serious or fatal injury. For your safety, use personal protective equipment (PPE) when operating this drive. Before applying power Verify that no foreign conductive material is present on the printed circuit board. Verify battery pack connections to the drive. Check for proper polarity. Incorrect polarity will damage the drive. Startup and Shutdown To start the drive: 1. Turn the speed adjust potentiometer full counter-clockwise (CCW) or set the voltage signal to zero. 2. Open the brake, enable and direction switches. 3. Apply DC power to (BAT +) and (BAT -) then close the enable switch. 4. Slowly advance the speed adjust potentiometer clockwise (CW), or increase the voltage signal. The motor slowly accelerates as the potentiometer is turned CW or the signal is increased. Continue until the desired motor voltage is reached. 5. Close the direction switch to change motor direction. 6. Open the ENABLE to coast the motor to a stop. To brake the motor to a stop, close the brake switch while the drive is powered. If the motor or drive do not perform as described, disconnect the DC voltage input immediately. Refer to the Troubleshooting section for further assistance.

13 Starting and stopping methods m WARNING Decelerating to minimum speed, braking or coasting to a stop is recommended for frequent starts and stops. Do not use any of these methods for emergency stopping. They may not stop a drive that is malfunctioning. Removing the DC power to the drive is the only acceptable method for emergency stopping. Frequent decelerating to minimum speed produces high torque. This may cause damage to motors, especially gear motors that are not properly sized for the application. Automatic restart upon power restoration If the enable switch is closed all drives will automatically run to set speed when power is applied. Line starting and line stopping Line starting and line stopping (applying and removing DC voltage input) is recommended for infrequent starting and stopping of a drive only. When DC voltage input is applied to the drive, the motor accelerates to the speed set by the speed adjust potentiometer. When DC voltage input is removed, the motor coasts to a stop.

14 Enable/Brake/Direction Enable Close the enable to allow the motor to run at the speed set by the speed pot or input signal. Brake Close the brake terminals to brake the motor to the speed set by the MIN SPD trimpot. The amount of time the drive takes to brake the motor to MIN SPD is determined by the DECEL trimpot. The amount of braking Torque used to stop the motor is set by the trimpot. MIN SPD is typically set to zero speed. Direction Close the direction terminals to change the motor direction. Note: In addition to dry contact inputs, the enable, brake and direction function also accept open collector inputs. Rated at 0.5 ma or greater. See Figure 9. Figure 9. Open Collector Input

15 Voltage follower Instead of using a speed adjust potentiometer, the drive may be wired to follow a 0-5 VDC signal (Figure 10). Connect the signal input (+) to S2. Connect the signal common (-) to S1. Make no connection to S3. A potentiometer can be used as a voltage divider to scale the analog input voltage. The analog signal common must be the same common as the battery common connected to BAT-. It is acceptable to connect the negative side of the battery to Earth ground in some applications. TB501 S2 S1 + _ 0-5 VDC Figure 10. Voltage Follower Connections

16 Calibration m WARNING Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the voltage input from the drive before adjusting the trimpots. If the trimpots must be adjusted with power applied, use insulated tools and the appropriate personal protection equipment. BE ALERT. High current can cause serious or fatal injury. Each drive is factory calibrated to its maximum armature voltage. The 174299.00 is factory calibrated at 170A. The 174298.00 is factory calibrated at 200A. Readjust the calibration trimpot settings to accommodate a motor with a lower armature voltage and current rating. All adjustments increase with clockwise rotation (CW), and decrease with counter-clockwise rotation (CCW). Use a nonmetallic screwdriver for calibration. Each trimpot is identified on the printed circuit board (see Figure 11). Figure 11. Calibration Trimpot Layout

MINIMUM SPEED (MIN SPD) The MIN SPD setting determines the motor speed when the speed adjust potentiometer is turned full CCW or when the BRAKE is closed. It is factory set for zero speed. To Calibrate MIN SPD: 1. Close the BRAKE terminals. 2. Turn the MIN SPD trimpot clock-wise until the desired motor speed is reached (usually zero). 17 MAXIMUM SPEED (MAX SPD) The MAX SPD setting determines the motor speed when the speed adjust potentiometer is turned full CW. It is factory set for maximum rated speed. To Calibrate MAX SPD: 1. Set the MAX SPD trimpot full CCW. 2. Apply power to the drive and turn the speed adjust potentiometer full CW. If an input voltage signal is used instead of a speed adjust pot, set the input signal to maximum. 3. Adjust the MAX SPD trimpot until the desired maximum motor speed is reached. ACCELERATION (ACCEL) The ACCEL setting determines the time the motor takes to accelerate to a higher speed. See Specifications for approximate accelerating times. The ACCEL setting is factory set to its minimum value (full CCW). To Calibrate ACCEL: 1. Set the ACCEL trimpot full CCW. 2. Apply power to the drive and turn the main speed adjust potentiometer full CW. If an input voltage signal is used instead of a speed adjust pot, set the input signal to maximum. Note the time that the drive takes to accelerate to the desired speed. 3. Adjust the ACCEL trimpot until the desired acceleration time is reached. Turn the ACCEL trimpot CW to increase the acceleration time, and CCW to decrease the acceleration time.

18 DECELERATION (DECEL) The DECEL setting determines the time the motor takes to decelerate to a lower speed. See Specifications for approximate deceleration times. The DECEL setting is factory set to its minimum value (full CCW). To calibrate DECEL: 1. Set the DECEL trimpot full CCW. 2. Apply power to the drive and turn the main speed adjust potentiometer from full CW to full CCW. If an input voltage signal is used instead of a speed adjust pot, set the input signal from maximum to minimum. Note the time that the drive takes to decelerate to the desired speed. 3. Adjust the DECEL trimpot until the desired deceleration time is reached. Turn the DECEL trimpot CW to increase the deceleration time, and CCW to decrease the deceleration time. IR COMPENSATION (IR COMP) The IR COMP setting determines the degree to which motor speed is held constant as the motor load changes. It is factory set for no compensation. Use the following procedure to recalibrate the IR COMP setting: 1. Set the IR COMP trimpot to minimum (full CCW). 2. Rotate the speed adjust potentiometer until the motor runs at midspeed without load (for example, 900 RPM for an 1800 RPM motor). A hand held tachometer may be used to measure motor speed. 3. Load the motor armature to its full load armature current rating. The motor should slow down. 4. While keeping the load on the motor, rotate the IR COMP trimpot until the motor runs at the speed measured in step 2. If the motor oscillates (overcompensation), the IR COMP trimpot may be set too high (CW). Turn the IR COMP trimpot CCW to stabilize the motor. 5. Unload the motor.

MOTOR CURRENT LIMIT () 19 m WARNING MOTOR CURRENT LIMIT should be set to 120% of motor nameplate current rating. Continuous operation beyond this setting may damage the motor. If you intend to operate beyond the rating, contact your Leeson representative. The MOTOR CURRENT LIMIT setting determines the maximum armature current output of the drive. Recalibrate the setting when a lower current limit is required. Refer to the settings in Figure 12 or 13, or recalibrate using the following procedure: 1. With the power disconnected from the control, connect a DC ammeter in series with the armature. 2. Set the trimpot to minimum (full CCW). 3. Set the speed adjust potentiometer to maximum (full CW). 4. Carefully lock the motor armature. Be sure that the motor is firmly mounted. 5. Apply line power. The motor should be stopped. 6 Slowly adjust the trimpot CW slowly until the armature current is 120% of motor rated armature current. 7. Set the speed adjust potentiometer, or input voltage to minimum. 8. Remove the power from the drive and unlock the motor shaft. 9. Remove the ammeter in series with the motor armature if it is no longer needed and re-apply power to the drive. REGENERATIVE CURRENT LIMIT () The REGENERATIVE CURRENT LIMIT setting determines the maximum armature current available for braking. Set the based on the desired amount of braking.

20 174298.00 1/2 HP 12 VDC 1/2 HP 24 VDC 3/4 HP 12 VDC 3/4 HP 24 VDC 1 HP 12 VDC 1 HP 24 VDC 1 1/2 HP 12 VDC 1 1/2 HP 24 VDC 2 HP 24 VDC 2 1/2 HP 24 VDC 3 HP 24 VDC Note: The above settings are approximate. Your settings may be different due to tolerance in the drive and motor along with application requirements. Figure 12. Approximate and Settings

21 174299.00 1 HP 36 VDC 1 HP 48 VDC 1 1/2 HP 36 VDC 1 1/2 HP 48 VDC 2 HP 36 VDC 2 HP 48 VDC 3 HP 36 VDC 3 HP 48 VDC 3 3/4 HP 36 VDC 4 HP 48 VDC 5 HP 48 VDC Note: The above settings are approximate. Your settings may be different due to tolerance in the drive and motor along with application requirements. Figure 13. Approximate and Settings

22 Application Notes Multiple fixed speeds Replace the speed adjust potentiometer with series resistors with a total series resistance of 10K ohms (Figure 14). Add a single pole, multiposition switch with the correct number of postions for the desired number of fixed speeds. S3 S2 TOTAL SERIES RESISTANCE 10K OHMS S1 Figure 14. Multiple Fixed Speeds

23 Adjustable speeds using potentiometers in series Replace the speed adjust potentiometer with a single pole, multi-position switch, and two or more potentiometers in series, with a total series resistance of 10K ohms. Figure 15 shows a connection for fixed high and low speed adjust potentiometers. CW S3 S2 S1 HIGH SPEED LOW SPEED 5K OHM CW 5K OHM Figure 15. Adjustable Fixed Speeds Using Potentiometers in Series

24 RUN/JOG Switch Using a RUN/JOG switch is recommended in applications where quick stopping is not needed and frequent jogging is required. Use a single pole, two position switch for the RUN/JOG switch, and a normally closed, momentary operated pushbutton for the JOG pushbutton (see Figure 16). When the RUN/JOG switch is set to JOG, the motor decelerates to minimum speed. Press the JOG pushbutton to jog the motor. Return the RUN/JOG switch to RUN for normal operation. S3 CW S2 10K OHM SPEED POT S1 RUN JOG JOG PUSHBUTTON Figure 16. RUN/JOG Switch Connection to Speed Adjust Potentiometer

Troubleshooting 25 m WARNING Dangerous voltages and currents exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the drive while troubleshooting. High current can cause serious or fatal injury. Before troubleshooting Perform the following steps before starting any procedure in this section: 1. Disconnect DC voltage input from the drive. 2. Check the drive closely for damaged components. 3. Check that no foreign conductive material has become lodged on the printed circuit board. 4. Verify that all connections are correct and in good condition. 5. Verify that there are no short circuits or grounded connections. 6. Check that the drive s rated armature voltage and current is consistent with the motor ratings. 7. Verify that input voltage (battery) is within specified range. For additional assistance, contact your local Leeson distributor.

26 Status LEDs Power LED Green LED lights up when power is applied to the drive. Fault Code LED Provides a visual representation of the cause of a fault. Faults 2-5 require either the Enable or battery voltage to be cycled in order to clear the fault. Solid ON - Current Limit 2 Blinks - Under Voltage fault 1 3 Blinks - Over Voltage fault 2 4 Blinks - Short circuit on output 5 Blinks - Over Temperature Fault Over Temperature current fold back/trip: If the drive heats up because it is overloaded or it is in an undersized enclosure, the drive will scale back the current limit in an attempt to lower the temperature. If the temperature isn t reduced after a period of time, the drive will trip. 1 Under Voltage fault set at 7.5 VDC for the 174298.00 and at 16 VDC for the 174299.00 2 Over Voltage fault set at 30.5 VDC for the 174298.00 and at 62 VDC for the 174299.00.

27 Symptom Possible Causes Suggested Solutions Line fuse blows Line fuses are the wrong size. Motor cable or armature is shorted to ground. Check that line fuses are the correct size. Check motor cable and armature for shorts. Nuisance tripping caused by a combination of ambient conditions and high-current spikes. Add a blower to cool the drive components; decrease settings, or resize motor and drive for actual load demand, or check for incorrectly aligned mechanical components for jams. See the Calibration section for information on adjusting the trimpot. Damaged Drive Contact Leeson Drives Distributor Line fuse does not blow, but the motor does not run. Speed adjust pot or reference voltage is set to zero speed. MAX SPD pot is set to zero. Speed adjust pot or reference voltage connections are open. Drive is overloaded. Drive is not receiving DC line voltage. Motor is not connected. Brake terminals are closed or ENABLE is open. Increase speed adjust pot or reference voltage setting. Increase MAX SPD pot. Check that the speed adjust pot or reference voltage connections are not open. Verify that the motor is not jammed. Increase setting. Apply DC line voltage to BAT + and BAT -. Confirm power LED is illuminated. Connect motor to A1 and A2. Open the BRAKE or close the ENABLE.

28 Symptom Possible Causes Suggested Solutions Motor runs too fast at maximum speed setting or minimum speed setting. MIN SPD and MAX SPD settings are too high. Recalibrate MIN SPD and MAX SPD. Motor will not reach the desired speed. Battery voltage too low. MAX SPD setting is too low. Charge batteries. Increase MAX SPD setting. IR COMP setting is too low. Increase IR COMP setting. Motor is overloaded. Check motor load. Resize the motor and drive if necessary. Check red fault LED status. Drive is reaching over temperature trip. Check motor load. Resize the motor or enclosure. Motor pulsates or surges under load. IR COMP is set too high. Adjust the IR COMP setting slightly CCW until the motor speed stabilizes. Control is in current limit mode. Check that motor and drive are of sufficient horsepower and current rating.

29

LEESON ELECTRIC MOTORS, GEARMOTORS AND DRIVES R 2 1 0 0 Wa s h i n g t o n S t r e e t G r a f t o n, W I 5 3 0 2 4-0 2 4 1 U. S. A. P h o n e : ( 2 6 2 ) 3 7 7-8 8 1 0 ; F a x : ( 2 6 2 ) 3 7 7-3 4 4 0 D o c u m e n t N u m b e r 2 5 0 0 4 0 3, R e v i s i o n 0 P r i n t e d i n t h e U. S. A - - M a r c h 2 0 0 6