PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

Similar documents
PM300E Voltage Regulator Instruction Manual

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

MX431 Generator Automatic Voltage Regulator Operation Manual

EA07. Generator Automatic Voltage Regulator Operation Manual

Worm Gear Reducers Installation, Lubrication and Maintenance Instructions

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

I N S TA L L AT I O N G U I D E

I N S TA L L AT I O N G U I D E

Installation, Lubrication and. Maintenance. Instructions CONGRATULATIONS!

I N S TA L L AT I O N G U I D E

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

I N S TA L L AT I O N G U I D E

PANCAKE GENERATOR Installation, Operation and Maintenance Manual

2000HG NEW STYLE HELICAL GEAR RATIO MULTIPLIER. INSTALLATION AND MAINTENANCE MANUAL May 4, Indianapolis, Indiana (800)

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

Gen 2 Portal Gear Hubs for Polaris Ranger Crew 570/900

XR500B Universal Voltage Regulator

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

CONTROL FEATURES AVAILABLE OPTIONS

IVT-1260 & IVT Generator Auxiliary Excitation Booster Operation Manual. (Patent Pending)

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

VoltPro VP4 Automatic Voltage Regulator

Filtered PWM Speed Control for Permanent Magnet DC Motors

EA16. Generator Automatic Voltage Regulator Operation Manual

Ironman E Series Installation, Lubrication and Maintenance Instructions

Ironman e Series Installation, Lubrication and Maintenance Instructions

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

n Agricultural n Commercial n Telecommunications n Rental Markets n Design & Application Experience n Advanced Testing Facilities

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

DC POWER SUPPLY ALIMENTATION C.C.

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

VoltPro VPBF8 Automatic Battery Flashing Module This Manual Covers Both VPBF8-12 and VPBF8-24 Models

Switching DC Power Supply

RP-4000 Reserve Power Control

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

FAULT FINDING MANUAL. For Stamford AC Generators

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

PowerOhm Installation Manual for LG ATV Series Braking Modules

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

P445 Series Electronic Lube Oil Control

PowerOhm Installation Manual for BM R Series Braking Modules

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

TECHNICAL SPECIFICATION

Installation Manual Model 3800/3810

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

XR500D-277V Special Voltage Regulator

Operations Manual. Zero Speed Switch Sensor Model ZS09P

RVS-AX Instruction Manual

2000RA SMOOTH BODY WORM GEAR REDUCER. INSTALLATION AND MAINTENANCE MANUAL June 26, Indianapolis, Indiana (800)

Electric Motor. Owner s Manual

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

MODEL 422 Submersible Pump Controller

Pump Installation and Service Manual HRS Hydromatic Retractable System

5001TCP SPEED CONTROLLER

ESD5550 / 5570 Series Speed Control Units

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

INDUSTRIAL POWER SUPPLIES SFL-SERIES

AFM500X Automatic Flashing Module

ENGINE GOVERNING SYSTEMS

ADI-125/750 ADI-125/1500 ADI-125/2500

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

PowerOhm Installation Manual for BM R Series Braking Modules

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

5001TCP SPEED CONTROLLER

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

High Frequency SineWave Guardian TM

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

TECHNICAL SPECIFICATION

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

ELECTRIC MOTOR. Owner s Manual

P66 Series Electronic Fan Speed Controls

Phase Sequence Tester

EG3000. Generator Electronic Governor Controller Operation Manual

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

EG3002. Electronic Engine Governor Controller User Manual

PID-1500 THERMOELECTRIC & RESISTIVE HEATER TEMPERATURE CONTROLLER INSTRUCTION MANUAL

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

SE450 Static Exciter Module

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

Transcription:

PM500 Voltage Regulator User Manual A Regal Brand Scan here for other languages.

Introduction The PM500 is an encapsulated electronic voltage regulator intended for use with Marathon Generators PMG system. The PM500 controls the output of a brushless AC generator by regulating the DC current input to the exciter field. The PM500 is designed as a three phase or single phase sensing regulator that is capable of accepting analog voltage adjustment input. The PM500 is UL Recognized and UL Certified for Canada - Component per UL File E222903. The PM500 also bears the CE mark for the European Union. Specifications Sensing Input Power Input, PMG w/ capacitor Power Output, Continuous Power Output, Forcing Fuse Voltage Regulation Excitation Resistance Remote Voltage Adjustment Range Analog Voltage Input A1 & A2 Roll-Off Frequency Factory Settings Voltage Build-up Response Time Weight Operating Temperature Storage Temperature Power Dissipation Size Thermal Drift Electromagnetic Compatibility Tests 175-600Vac, 50Hz/60Hz, 3 Phase/1 Phase 200-260Vac, 40-300Hz, 7.5µƒ capacitor 170 Vdc at 3.5Adc with 220Vac input power 170 Vdc at 7Adc for 10 sec. with 220Vac input power 5 x 20mm S505-5A, Slow Blow Type ± 0.5%, with 4% engine governing 9 ohms, minimum ± 10% with 1000 ohm rheostat ± 5% with 500 ohm rheostat ± 20% with 0-10Vdc or ± 5Vdc bias 47Hz preset for 50Hz operation 57Hz preset for 60Hz operation Voltage build up from input voltage 5Vac at 25Hz. <1 Cycle 16.6 oz. -40 C to +70 C -40 C to +85 C 12 watts, maximum 5.9 L x 5.3 W x 2.2 H 0.05% / C change in AVR ambient temperature Immunity IEC61000-4-2 - Electrostatic Discharge IEC61000-4-3 - Radiated RF IEC61000-4-4 - Electrical Fast Transient IEC61000-4-5 - Surge IEC61000-4-6 - Conducted RF IEC61000-4-11 Emission EN61204-3 - Conducted RF CISPR 22 IEC61000-3-2 - Harmonic IEC IEC61000-3-3 - Flicker IEC 2

Installation TO PREVENT PERSONAL INJURY OR EQUIPMENT DAMAGE, ONLY QUALIFIED PERSONNEL SHOULD INSTALL, OPERATE OR SERVICE THIS DEVICE. DO NOT megger or high-pot the generator with the regulator connected. DO NOT high-pot the regulator. All voltage readings are to be taken with an average-reading voltmeter. MOUNTING The PM500 is mounted through a keyed hole in the generator conduit box and secured with a plastic mounting nut. The PM500 should be mounted directly to the conduit box panel with the rubber gasket positioned between the outside of the conduit box panel and the mounting nut. Protect front panel adjustment pots by installing clear or black plastic cover. Mounting nut torque is 26 43 lbf-in. Refer to the Figure 1 for dimensions. Figure 1 Wiring and Connections EXCITER FIELD POWER CIRCUIT The exciter field resistance must be 9 ohms. If the exciter field resistance is less than 9 ohms and the full load field current does not exceed 3.5 amps, add a resistor in series of sufficient wattage to increase the total resistance to 9 ohms. When the PMG system is not functional, the PM500 may be shunt powered from the generator output leads. Connect regulator terminal P1 & P2 to generator leads that will provide 240Vac output. The capacitor is not used when the PM500 is shunt powered. Refer to Figure 3 for typical connection points. Connect the generator F+ (F1) field lead to the regulator F+ terminal. Connect the generator F- (F2) field lead to the regulator F- terminal. Refer to Figure 3 for typical connection points. POWER INPUT CIRCUIT The PM500 is designed to be powered by a PMG and capacitor. A 7.5µƒ capacitor is to be connected in parallel between the PMG leads and the regulator power input terminals. The regulator power input terminals are labeled P1 and P2. Connect leads P1 and P2 to the capacitor terminals. Figure 2 3

Wiring and Connections (cont d) Figure 3a Three Phase Figure 3b Single Phase SENSING CIRCUITS Sensing input range is 175-600Vac. DIP switch SW2-1 must be set appropriately. Single Phase Sensing Connect PM500 terminal E1 to output lead L1 and E2 to output lead L2. PM500 terminal E3 is jumpered to E2. Refer to Figure 3b for typical connections. 3 Phase Sensing Connect PM500 terminal E1 to output lead L1, E2 to output lead L2 and E3 to output lead L3. If used in a paralleling application, a paralleling CT will be required in the generator B phase. Paralleling CT must be sized to provide either a 1A or 5A signal when the generator is under full load. DIP switch SW2-6 must be set appropriately. Refer to Figure 3a for typical connections. 4

Wiring and Connections (cont d) DIP SWITCH PROGRAMMING Eight DIP switches located on the back of the regulator must be set appropriately for correct generator operation. Refer to Figure 5. SW1 Sets regulator sensing range SW1-1 : OFF : SW1-2 : OFF : Volts 240Vac SW1-1 : OFF : SW1-2 : ON : Volts 440Vac SW1-1 : ON : SW1-2 : ON : Volts 600Vac SW2 Configures multiple regulator functions: Phase, Frequency, Over Excitation Protection, kw Range and Paralleling CT range. SW2-1 : OFF : Single Phase : ON : Three Phase SW2-2 : OFF : 60Hz : ON : 50Hz SW2-3 : OFF : Over Excitation Protection Enabled SW2-3 : ON : Over Excitation Protection Disabled SW2-4 : OFF : SW2-5 : OFF : < 90kW SW2-4 : ON : SW2-5 : OFF : 90-500kW SW2-4 : ON : SW2-5 : ON : > 500kW SW2-6 : OFF : 1A CT : ON : 5A CT Over Excitation The Over Excitation function protects the PM500 and generator components in the event the excitation system demands excessive levels of voltage and/or current to maintain output. The Over Excitation function will trip when excitation output exceeds 190Vdc or 7Adc for more than 10 sec. with 220Vac input power. The Over Excitation O/E LED on the front panel will be illuminated when the PM500 when the Over Excitation system has tripped. Replace the fuse on the back panel if required and inspect the generator. The PM500 will reset when power is cycled Under Frequency Under Frequency protection allows the generator voltage to decrease when the output frequency drops below the Roll-Off point. This reduces the load on the engine, allowing engine RPM to recover. This is normal operation and no reset is required. Over Voltage The Over Voltage function will trigger when excessive output voltage is detected: 240VAC 440VAC 600VAC Output (V) Trip (V) Instantaneous 240 310 330 440 560 580 600 700 720 When excessive output voltage is detected an internal SCR will short power output causing the input fuse on the back panel to blow. Over Voltage protection is a single use system. To reset the PM500 for operation without Over Voltage protection, disconnect the OVP jumper on the back panel and replace the input fuse located on the back panel. It is recommended that the PM500 be replaced as soon as feasible. Figure 5 PROTECTION FUNCTIONS The PM500 has built in protection functions for Over Excitation, Under Frequency and Over Voltage Protection. 5

Operating Adjustments Six screwdriver adjustable potentiometers are accessible on the front panel of the PM500. These are: VOLT, STAB, U/F, DIP, DROOP and TRIM. factory preset at 57Hz for 60Hz operation and 47Hz for 50Hz operation. When the U/F LED on the front panel it lit, the PM500 is operating in Under Frequency mode. To change the roll-off point, first verify that the gen-set is operating at the intended speed and voltage. Figure 6 VOLTAGE ADJUST (VOLT) Set Point Output voltage may be adjusted via the VOLT potentiometer on the front panel of the regulator. The set point range is 175-600Vac. Remote Voltage Adjust A 1000 ohm, 1 watt rheostat may be connected to VR1 and VR2 - replacing the factory jumper, providing a ±10% voltage adjustment range. Terminals A1 & A2 may not be used when a rheostat is installed. Analog Voltage Adjust Regulator terminals A1 & A2 may be connected to the analog output of a gen-set controller. The allowable voltage input range is 0-10Vdc or ± 5Vdc will provide a 20% range. Jumper VR1 & VR2 when analog voltage adjustment terminals are used. TRIM ADJUST (TRIM) The analog bias range is adjusted via the TRIM potentiometer on the front panel. Set the TRIM potentiometer fully clockwise to provide a ± 20% adjustment range. DROOP ADJUST (DROOP) Requires a 1A or 5A CT in the B Phase. DIP switch SW2-6 must be set appropriately. In a paralleling system, the PM500 adjusts the generator output voltage when the B phase current leads or lags the B phase voltage. The adjustment range may be preset via the DROOP potentiometer. The default setting is full counter clockwise for minimum range. Maximum range is ±7% at 0.7 PF lagging to 0.7 PF leading. UNDER FREQUENCY ROLL-OFF ADJUST (U/F) The Roll-Off point is the frequency at which the generator output voltage is allowed to decrease and is Fixed Engine RPM On most new engines (Tier 4i and up), the engine speed is fixed at either 1800RPM or 1500RPM. Adjust the roll-off point by block loading the generator and observing the U/F LED on the front panel. To ensure the generator maintains voltage under a given block load, adjust U/F potentiometer until the U/F LED remains off during the block load test. Adjustable Engine RPM Adjust engine speed to the new roll-off point. Verify that the output voltage still matches the intended setpoint voltage. Next, adjust the U/F potentiometer clockwise until the voltage starts to drop off, then slightly adjust the potentiometer counterclockwise until the voltage returns to rated voltage. Re-adjust engine speed to rated speed. U/F DIP ADJUST (DIP) When Under Frequency (U/F) protection is activated, the voltage dip follows a linear Volts / Hertz curve. The voltage dip ratio may be adjusted via the DIP potentiometer with an adjustable range of 3-10V/Hz. The default setting is full clockwise for 10V/Hz. STABILITY ADJUST (STAB) Stability is the ability of the generator to respond to load changes. Decreasing the stability setting allows the generator to respond faster to load changes. If the stability setting is too low, the generator voltage will tend to hunt under steady state conditions. Correct stability adjustment must be conducted while the generator is operating unloaded. Adjust the STAB potentiometer clockwise until the voltage becomes unstable, then slightly adjust counterclockwise (Approximately 1/5 turn) until the voltage becomes stable. 6

Warnings & Cautions IMPORTANT INFORMATION Please Read Carefully This document is not intended to provide operational instructions. Appropriate Marathon Electric instructions provided with the generator and precautions attached to the generator should be read carefully prior to installation, operations and/or maintenance of the equipment. Injury to personnel or generator failure may be caused by improper installation, maintenance or operation. The following and information is supplied to you for your protection and to provide you with many years of trouble free and safe operation of your Marathon Electric product: Buyer shall be solely responsible for determining the adequacy of the product for any and all uses to which Buyer shall apply the product. The application by Buyer shall not be subject to any implied warranty of fitness for a particular purpose. For safety, Buyer or User should provide protective guards over all shaft extensions and any moving apparatus mounted thereon. The User is responsible for checking all applicable safety codes in his area and providing suitable guards. Failure to do so may result in bodily injury and/or damage to equipment. Hot oil can cause severe burns. Use extreme care when removing lubrication plugs. Disconnect power and lock out drive equipment before working on a generator. Always keep hands and clothing away from moving parts. The lifting eyes on the generator are not to be used to lift the entire generator set. Only the generator may be safely lifted by the lifting eyes. Do not use the conduit box for lifting or support of the generator. Install and ground the generator per local and national codes. Discharge all capacitors before servicing the generator. Misapplication of a generator in a hazardous environment can cause fire or an explosion and result in serious injury. Never attempt to measure the temperature rise of a generator by touch. Temperature rise must be measured by thermometer, resistance, imbedded detector or thermocouple. Operation of a generator at higher than its nameplate ratings may result in fire, damage to equipment or serious injury to personnel. Do not apply any force to the generator fan when rotating the generator rotor. Generators should not be operated faster than their rated speed. The following statement is only applicable to high voltage generators (above 5000 V). A grounding strap is supplied from the generator neutral to ground. This grounding strap not only bleeds off any voltage potential on the main stator after the high potential test, but also bleeds off any static charge that can build-up on the main stator during shipment and storage. THIS GROUND STRAP IS NOT A PERMANENT PART OF THE GENERATOR CONSTRUCTION. REMOVE THIS GROUND STRAP ONLY AFTER A PERMANENT GROUND IS INSTALLED ON THE GENERATOR MAIN STATOR (not supplied by Marathon Electric), OR THE GENERATOR FINAL INSTALLATION IS COMPLETE. Mounting bolts should be routinely checked to ensure that the unit is firmly anchored for proper operation. Consult qualified personnel with questions. All electrical repairs must be performed by trained and qualified personnel only. For inverter applications, follow the inverter manufacturer s installation guidelines. Make sure the generator is properly secured and aligned before operation. When installing the generator, insure that loose parts or tools do not fall inside the generator. When connecting the generator, be sure to follow the correct wiring diagram for the desired voltage. Insure that the voltage regulator is connected per the wiring diagram. RESALE OF GOODS In the event of the resale of any of the goods, in whatever form, Resellers/Buyers will include the following language in a conspicuous place and in a conspicuous manner in a written agreement covering such sale: The manufacturer makes no warranty or representations, express or implied, by operation of law or otherwise, as to the merchantability or fitness for a particular purpose of the goods sold hereunder. Buyer acknowledges that it alone has determined that the goods purchased hereunder will suitably meet the requirements of their intended use. In no event will the manufacturer be liable for consequential, incidental or other damages. Even if the repair or replacement remedy shall be deemed to have failed of its essential purpose under Section 2-719 of the Uniform Commercial Code, the manufacturer shall have no liability to Buyer for consequential damages. Resellers/Buyers agree to also include this entire document including the cautions and warnings above in a conspicuous place and in a conspicuous manner in writing to instruct users on the safe usage of the product. This information should be read together with all other printed information supplied by Marathon Electric. For more information contact: Regal Beloit America, Inc., 100 E. Randolph St., Wausau, WI 54401 Phone: 715-675-3311 or Fax: 715-675-8026 7

100 E. Randolph Street PO Box 8003 Wausau, WI 54402-8003 U.S.A. PH: 715-675-3359 FAX: 715-675-8026 A Regal Brand www.marathonelectric.com 2015 Regal Beloit Corporation GPN056 7904J-NP/1K/11-15/FS Printed in the U.S.A.