Series Cantilever Liquid Level Control

Similar documents
CT Series Flex Tube. Displacer Type Level Controller. Specifications

MLS Meter Leveling Saddle. Parts List

Model 3200 Liquid Level Controller

Model 3201 Liquid Level Controller

Series 1001, 1001A and 1001XL Level Controllers

Mallard Control Control Valves

Mallard. Model 3200 Liquid Level Controller. Features

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Fisher L2 Liquid Level Controller

Installation Operation and Maintenance Instructions Model Contents

TK-6024, TK-6124, TK-8024, TK-8124

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

Deep Well Pump Control Valve

LEVEL CONTROL SWITCHES

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches

MOONEY FLOWGRID SLAM SHUT REGULATORS

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

8500 Series Three-Way, Two Position, High Pressure Valve

PRESSURE REDUCING VALVE

Model 5000 Level Controller

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

D1 Series Top Guided Single Seated Control Valves

1450 Control Valve. General Instructions. Table of Contents

PRESSURE REDUCING CONTROL VALVE

Fisher 2506 and 2516 Receiver Controllers

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

PRESSURE REGULATORS PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Crispin Valves Operating Guide. Crispin

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

LEVER OPERATED LIQUID LEVEL CONTROLS

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

Pilot-Operated Regulators

Bourdon Tube Pressure Switches

Temperature Sensor Series

Tool-less Hinged Closure Installation, Operation, & Maintenance

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

Series Roll Seal

CACTUS FLOW PRODUCTS

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

MECHANICAL LEVEL CONTROLS

DEMCO Resilient Seated Butterfly Valve

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

Pressure Sensor No Series

RF Point Level Control with Sensor Monitor

DRAWING INDEX 1 07/01/2013. Company Project Project Number Location Revision Date

Tuffy Liquid Level Switches

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Fisher 657 and 667 Diaphragm Actuators

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

550 Series Back Pressure, Low Pressure Valve

STYLE J COMBINATION PRESSURE AND TEMPERATURE REGULATOR

TRUNNION MOUNTED BALL VALVE INSTALLATION, MAINTENANCE, & REPAIR MANUAL

Fisher Pneumatic Controllers and Transmitters

Fisher D2T FloPro Control Valve

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

Index. Butterfly Valves

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

2-20 (50mm-500mm) SERIES 30/31 Wafer/Lug RESILIENT SEATED BUTTERFLY VALVES. The High Performance Company

Low Profile J Series Power Unit with Vane Pump

P99 Pressure Reducing Regulator

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

Powers Controls RL 147 Positioning Relay

ANDERSON GREENWOOD. Before installation these instructions must be fully read and understood.

SAE FLANGES V C. Specialists in VESCOR. Hydraulic Reservoirs and Accessories

PRODUCT NEWS CAT.NO.-70 KPC CORPORATION FLOW CONTROL DIVISION

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Adjustable Differential Relay A1

DEMCO Resilient-Seated Butterfly Valve

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

Engineered Performance

2506 Series Multi-Trol Receiver/Controllers (Types 2506, 2516, 2516F)

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

MERCER VALVE SERIES Flanged THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

SPECIFICATIONS. Installation arrow must point downward Vertical Valve For top mounting.

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Evans SN Series. Evans. Sanitary & Vacuum Ball Valves

Industrial Turbo Meters, Sizes 2" through 6"

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Jo-Bell Products. DIVISION OF DALNOR SYSTEMS, INC Sierra Vista Drive Carlsbad NM, Phone: Fax:

Set-Up Instructions. for EC-VM400. Motorized Valves

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

RP-1350 Rev. 1. Parts List. Model 441-S Regulator. Parts List. Copyright 1999 Invensys Energy Metering

Transcription:

Series Section No. 3. Application Cantilever liquid level control series offers design simplicity, easy installation, adjustment, and reliable liquid level monitoring. It is a highly efficient device for the control of liquid level in oil and gas production equipment such as: separators, dehydrators, and treaters, as well as in manufacturing plants, hazardous waste disposal, food processing, water treatment, petro-chemical facilities, or wherever fluid levels need to be monitored or controlled. sensing element design, with no moving parts exposed to the tank or vessel fluid, makes the simple installation of the control possible in various standard pipe closures such as: ANSI flanges and grooved, or union, connections. sensing element has a selection of three control head options that control pneumatic supply to control valves, alarm systems, pressure switches, solenoids, and relays, all of which may be used in response to liquid level changes. se control options are: Snap Action Throttling Throttling This throttling control head assembly provides a proportional output pressure signal as changes in vessel liquid levels are sensed by the displacers and transmitted by the sensing rod. Constant vessel liquid level can be maintained when the control outlet is connected with a properly sized pneumatic, diaphragm activated control valve. Sensing adjustment is controlled by an external adjusting screw. Snap Action snap action control head assembly provides on/off supply pressure at a specific liquid level set point established by the displacer setting. This on/off signal can be used to power pressure switches, start-up or shut-down controls, alarms, or pneumatic diaphragm activated control valves to open or close system flow lines. Features Industry Standard Design Simplicity Optional Pilot Head Throttle or Snap Acting Optional Process Connections See Chart Optional Choice of Sensing Rod See Chart Optional Choice of Displacer See Chart Optional Low-Bleed MIZER See Chart Specifications Max. Working Pressure....................... 100 Operating Temperature.................. -20 F or +200 F (higher temperature available) Process Connections.......................... See Chart Pilot Connections........................... 1/4" FNPT Supply Pressure........... 20 Minimum-30 Maximum (limited by pressure gauge) Output Pressure...................... 3-1 Throttle 0-Full Supply Snap (Pilot good to 7 ) Materials Displacer.................................. See Chart Process Connection........................ Carbon Steel Sight Glass............................. Polycarbonate Sensing Rod................................ 316 S.S. Seals.................. Buna-N Standard (others available) Hammer Union Ring...................... 4" and " WCB Others Fabricated Carbon Steel WARNING If supply gas is flammable or noxious, this product MUST be located in a well ventilated non-hazardous area or sealed and vented to a non-hazardous area. Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners. 9

Section No. 3. Series Principle of Operation This liquid level control operates on the basis of two basic physical laws: 1. A solid, heavier than a fluid (a displacer/s) will, if placed in it, descend to the bottom of the fluid, and the solid will, when weighed in the fluid, be lighter than its true weight by the weight of the fluid displaced. Archimedes' Principal 2. A Cantilever beam (sensing rod) projecting outward, anchored at one end, will flex in proportion to the weight applied, or removed, at the free end. refore, following Archimedes' Principal, a body (displacer or float) immersed in a fluid experiences a buoyant, or lift force equal to the weight of the displaced fluid. This static lift force acts vertically through the center of gravity of the displaced volume. Applying the above fundamentals to this liquid level control, we can sense and regulate levels of most gas to fluid interface applications as well as many fluid to fluid interfaces. By attaching a displacer to the free end of the sensing rod, vertical movement is achieved. rising and lowering of the fluid gives the static lift force-either up or down, which is transferred along the rod to an actuator pad extending out past the anchored end. As the actuator pad moves to the nozzle, supply pressure is diverted to output, opening a diaphragm-operated motor valve. As fluid is drained, and fluid level declines, the actuator pad moves away from the nozzle and supply pressure is relieved from the diaphragm operated motor valve, and valve closes, allowing the cycle to repeat. In a throttling mode, this procedure will continually throttle the valve to maintain the fluid level at a desired set point. In a snap-acting mode, a shuttle pilot is attached to the throttling head converting the throttling output pressure to pilot signal pressure, tripping the shuttle pilot to either full supply pressure, opening valve quickly, or to zero supply pressure, allowing valve to close. Installation Before installing this control, inspect the unit for any shipment damage or any foreign material. Visually observe that the actuator pad and rod-end are centered in the sensing rod connector. If not, the unit has been distorted and should be returned to center before placing the control in service. Check for mechanical clearance of displacer for free movement by flicking the actuator pad after installation of the unit. If vibration is observed, unit is free to work as intended. Connect suitable supply gas line to the 1/4" FNPT connection stamped "IN". 20 to 30 is recommended for proper operation (Filtered gas or air is strongly recommended for better and longer maintenance-free operation.) Connect "output" port, stamped "OUT" to unit to be controlled. Start-Up Procedure Energize the control by opening the supply gas to pilot head (20 to 30 recommended). Adjust the nozzle upward toward the actuator pad, by loosening nozzle lock nut and turning nozzle clockwise, until output pressure gauge starts to indicate a reading (1-3 ). Observing the fluid level through the level glasses for desired level, adjust the nozzle up or down to actuate the diaphragm-operated motor valve when desired level is obtained. When satisfactory fluid level is obtained, tighten nozzle lock nut to secure setting. Observe several cycles to assure that the system is properly functioning. NOTE: To increase fluid level set-point, adjust the nozzle counterclockwise away from the actuator pad. To decrease fluid level setpoint, adjust nozzle counter-clockwise toward actuator pad. Normal pilot installation is direct acting, rise in fluid level resulting in an increase of output. For indirect acting, rise in fluid level resulting in a decrease of output, simply loosen 3/4-16 jam nut behind pilot head, and rotate pilot head 180 and retighten 3/4-16 jam nut. Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 10 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners.

Series Section No. 3. Chart 1: Determining the Model Number MODEL 4C SU-RLC-AO1 2", 3", 4", ", 6" All 6" Connection H.U. Rings are ACME Thread 4" & " Connection H.U. Rings are "V" Thread Std. ACME available (specify when ordering) and add the letter "A" as a suffix to Connection Code C Cantilever F Flange G Grooved S Screwed Bushing (2" Only) U Hammer Union Blind Flange SG Grooved w/sight Glass (4" & ") SU Hammer Union w/sight Glass Y Yale Blind Flange (less H.U. Ring) SY Yale Flange w/sight Glass (less H.U. Ring) LC Pneumatic Throttling RLC Pneumatic Snap Acting LMZ MIZER Throttling RMZ MIZER Snap Acting Size Process Connection Pilot Head Displacer (Float) Flange Rating Rod Type 1 2" x 10" Delrin Screw-on 2 2" x 12" Delrin Screw-on 3 2" x 10" Phenolic Screw-on 4 2" x 12" Phenolic Screw-on 21/2" x 8" Delrin Screw-on 6 21/2" x 7" Delrin Screw-on 7 21/2" x 8" Slide-on Delrin 8 31/4" x 2 3/4" Phenolic (3)* 9 31/4" x 2 3/4" Phenolic (4)* 0 23/4" x 10" PVC Screw-on* 1 10 Class 3 300 Class 6 600 Class 0 Other Type Connection A Short (Dumpy) M Medium L Long Straight Cantilever Displacers Displacer Size Material Part No. Max. Temp. Continuous 2" DIA. X 10" SCREW-ON DELRIN 0011-182 200 2" DIA. X 12" SCREW-ON DELRIN 0011-190 200 2" DIA. X 10" SCREW-ON PHENOLIC 0600-24 27 2" DIA. X 12" SCREW-ON PHENOLIC 0600-237 27 2 1/2" DIA. X 8" SCREW-ON DELRIN 30076 200 2 1/2" DIA. X 7" SCREW-ON DELRIN 0011-084 200 2 1/2" O.D. X 8" SLIDE-ON DELRIN 0011-032 200 3 1/4" O.D. X 2 1/4 SLIDE-ON* PHENOLIC 0010-2342 400 2 3/4" DIA. X 10" SCREW-ON* PVC 300 16 *3 Displacers Required for Liquid Gas Interface *4 Displacers Required for Liquid Liquid Interface *2 3/4" x 10" Displacer Applicable for Either Liquid Gas or Liquid Liquid Interface Stainless Steel displacers available. Contact factory. 8" 2 1 /2" Dia. DELRIN & PHENOLIC SCREW-ON DISPLACERS (MEDIUM AND SHORT RODS) 10" DELRIN SLIDE-ON DISPLACERS (LONG STRAIGHT ROD ONLY) 2 3 /4" Dia. PVC SCREW-ON DISPLACER (MEDIUM AND SHORT RODS) PHENOLIC SLIDE-ON DISPLACERS ( LONG STR. & OFFSET ROD) 3 REQ'D LIQUID-GAS INTERFACE 4 REQ'D LIQUID-LIQUID INTERFACE Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners. 11

Section No. 3. Parts List for Cantilever Snap Acting Pilot Head Item Description Qty. Part No. 1 PILOT HOUSING, ALUM. ALLOY 383 1 0010-3472 2 STREET "L", MALLEABLE 2 06000-0684 3 PRESSURE GAUGE 2 06000-0700 4 ADJUSTING SCREW, 303 S.S. 1 0010-1674 NOZZLE, 303 S.S. 1 0010-1682 6 O-RING, NITRILE 2 0000-0033 7 JAM NUT, 18-8 S.S. 1 0010-2334 8 O-RING, NITRILE 1 0000-0074 9 COVER PLATE, POLYCARBONATE 1 0010-3720 10 COVER SCREW, NYLON 2 0010-3761 11 O-RING, NITRILE 2 0000-0009 12 BOOSTER BODY, ALUMINUM 1 0010-346 13 COVER, ALUMINUM 1 0010-3464 14 LOWER SEAT, ALUMINUM 1 0010-3423 1 UPPER SEAT, ALUMINUM 1 0010-3431 16 CONNECTOR, ALUMINUM 1 0010-3449 17 SCREW, STEEL PLATED 1 0000-291 18 SPRING, ASTM A-313 1 0010-3704 19 DIAPHRAGM, FAIRPRENE 1 0010-3712 20 GASKET, FAIRPRENE 1 0010-3696 21 FILLSTER HD. SCREW, STEEL 4 06000-1601 22* DAMPNER, STAINLESS STEEL 1 0010-3829 *Not Shown 1 10 20 2 10 11 2 3 Series 3 /4 APPROX. " APPROX. 10 1 20 2 9 13 1 16 12 21 19 17 14 18 20 1 6 4 8 7 1" 2 7 /8 APPROX. Parts List for Cantilever Throttling Pilot Head Item Description Qty. Part No. 1 PILOT HOUSING, ALUM. ALLOY 383 1 0010-1617 2 STREET TEE, MALLEABLE 2 06000-0676 3 PRESSURE GAUGE 2 06000-0700 4 ADJUSTING SCREW, 303 S.S. 1 0010-1674 NOZZLE, 303 S.S. 1 0010-1682 6 O-RING, NITRILE 2 0000-0033 7 JAM NUT, 18-8 S.S. 1 0010-2334 8 O-RING, NITRILE 1 0000-0074 9 COVER PLATE, POLYCARBONATE 1 0010-3720 10 COVER SCREW, NYLON 2 0010-3761 11 O-RING, NITRILE 2 0000-0009 1 10 20 2 6" APPROX. 3 7 /8 10 1 20 2 9 10 11 3 2 1 6 4 8 7 1" 2 7 /8APPROX. Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 12 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners.

Series Section No. 3. Cantilever Rods and Additional Components LOCK NUT (2) 0010-239 HEX NUT 0000-110 8 3 /16 4 7 /8 REFLECTOR (SIGHT GLASS MODELS ONLY) 3" P/N 0010-0741 4" AND " P/N 1002 SEAT 0010-1781 O-RING STD. 0000-0447 ADDITIONAL COMPONENTS FOR ALL RODS SHORT ROD ASSEMBLY 0600-0630 TRU-ARC RING (SIGHT GLASS MODELS ONLY) ADDITIONAL COMPONENTS FOR ALL RODS 12 3 /8 9 1 /8 VERTICAL FLOAT ADAPTER 0600-4301 (SHORT & MEDIUM RODS ONLY) MEDIUM ROD ASSEMBLY 0600-0036 4 FLOAT EXTENSION-0010-6970 HEX HD. SCREW 0000-2187 WASHER 06000-104 (LONG & OFFSET RODS ONLY) 19" 1 3 /4 HEX HD. SCREW-0000-1767 WASHER-06000-104 (LONG & OFFSET RODS ONLY) LONG ROD ASSEMBLY 0600-008 COLLAR W/ SCREW P/N 1009 (LONG ROD ONLY) VERTICAL FLOAT ADAPTER 0600-428 (LONG & OFFSET RODS ONLY) 19" 1 3 /4 11 3 /4 OFFSET ROD ASSEMBLY 0600-0002 Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners. 13

Section No. 3. Typical Assembly Series HEAD ASSEMBLY THROTTLING 0600-1307 SNAP ACTING 0600-131 THROTTLING MIZER 0600-6947 SNAP ACTING MIZER 0600-69 NOZZLE SEAT 0010-1781 HEX NUT 0000-110 O-RING 0000-0447 FLANGE 3" BLIND 0011-0337 3" SIGHT GLASS 0011-0667 4" BLIND 0010-766 4" SIGHT GLASS 0600-2040 " SIGHT GLASS 0600-2917 " ACME SIGHT GLASS 0600-076 TRU-ARC RING (SIGHT GLASS ONLY) 06000-0692 WARNING If supply gas is flammable or noxious, this product MUST be located in a well ventilated non-hazardous area or sealed and vented to a non-hazardous area. REFLECTOR (SIGHT GLASS MODELS ONLY) 3" 0011-0741 4"& " 1002 COLLAR (LONG ROD ONLY) 1009 WASHER (LONG & OFFSET ROD ONLY) 06000-104 SNAP ACTING HEAD JAM NUT 0010-239 WELD NECK O-RING 3" 0000-040 4" 0000-061 " STD. 0000-079 " ACME 0000-37 HAMMER UNION 3" BLIND FLG. 0600-0663 3" SIGHT GLASS 0600-0671 4" STD. THREAD 0012-670 4" ACME THREAD 0012-3702 " STD. THREAD 0012-9439 " ACME THREAD 0012-9496 WELD NECK 3" X " LG. 0011-2200 3" X 8" LG. 0010-2961 4" X " STD. 0011-468 4" X 8" STD. 0010-1799 4" X " ACME 0013-0216 4" X 8" ACME 0012-3694 " X 8" STD. 0010-4686 " X 6" ACME 0012-9470 " X 8" ACME 0013-0232 SENSING ROD ASSEMBLY SHORT 0600-0630 MEDIUM 0600-0036 LONG 0600-008 OFFSET 0600-0002 HEX SCREW (LONG & OFFSET ROD ONLY) 0000-1767 FLOAT 2" X 10" DELRIN 0011-182 2" X 12" DELRIN 0011-190 2" X 10" PHENOLIC 0600-24 2" X 12" PHENOLIC 0600-237 2 1 /2" X 8" DELRIN 0011-0311 2 1 /2" X 7" DELRIN 0011-084 2 3 /4" X 10" PVC 300 2 1 /2" X 8" DELRIN 0011-032 3 1 /4" X 2 3 /4" PHENOLIC 0010-2342 (3 REQ'D) THROTTLING HEAD SNAP ACTING HEAD PLUG 0010-709 ANSI RAISED FACE FLANGES 2", 3" AND 4" FLANGE 2"-10RF 0013-0869 2"-300RF 0012-944 3"-10RF 0011-922 3"-300RF 0011-948 3"-600RF 0011-9 4"-10RF 0010-6889 4"-300RF 0010-6897 4"-600RF 0010-690 2" MNPT PLUG Company, L.L.C. Oklahoma City, Oklahoma Tel: (40) 672-6660 Fax: (40) 672-6661 wellmarkco.com 14 2011 WellMark Company, L.L.C. Litho USA WM-11/10 All registered trademarks are the property of their respective owners.