TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

Similar documents
AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components

STANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE

Rural Water Supply Operations Seminar & Drill

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

Lakes Region Mutual Fire Aid, New Hampshire Rural Water Supply Operations Seminar & Drill. Tanker Shuttle Drill May 17, 2009 Summary Report

Driver/Operator Program Part III - Tanker

Chapter Quiz. Directions: Write the correct letter on the blank before each question.

Chapter 15. Fire Hose. Answer Key. Firefighter I

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report

Water Supply for Suburban and Rural Firefighting, First Edition Final Version December 2012

INSTRUCT-O-GRAM HOSE OPERATIONS THE HANDS ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XI, ISSUE 9 HOSE OPERATIONS SEPTEMBER 1990 INSTRUCTOR TASK

Tyger Drafting Eductors

Rural Water Supply Operations Seminar & Drill

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations

LEVEL 2 DEFENSIVE Standard Equipment Guide

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

Oconee County Emergency Services Westminster, South Carolina

Rescue Refresher: Vehicle Extrication

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

Shelby County First Ba3alion Shelby County, Alabama. LDH Relay Pumping Seminar Relay Pumping Drill May 20, 2017 Summary Report

Oconee County Emergency Services Westminster, South Carolina

Front Suction Flow Test

Table of Contents. Acknowledgments... xii Introduction... 1

TRAINING AND EQUIPMENT MANUAL PUMP OPERATOR S GUIDE EFFECTIVE: MARCH 2009

Essentials of Fire Fighting,

WATER SUPPLY AND DISTRIBUTION SYSTEMS

Lightweight Aluminum Alloy Adapters

The following is a list of guidelines that apply to all evolutions.

Relay Pumping Operations

Other significant updates include:

ESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised

Bulloch County Fire Department Bulloch County, Georgia. Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report

Ponderosa VFD Apparatus Driver Training

Innovative Firefighting Products

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

Fire Engine Information

Amenia Fire District Amenia, New York. LDH Relay Pumping Seminar Relay Pumping Drill August 26, 2018 Summary Report

ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

Essentials of Fire Fighting

Welcome to the Dover Fire Department Brian F. Bashista, Fire Chief

Background. Vehicle Specifications

West Metro Fire Protection District

Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD 2008, GBW Associates, LLC Westminster, Maryland

Gt oton Fire Department. Summary of the Boat House Road Fb e Water Supply Issues. Date of Incident: May 10, 2013

Positioning Aerial Apparatus By: Joe Kroboth, III, PE, CFPS Emergency Services Instructor MFRI, Western Maryland Regional Office

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump

Water Transfer. Performance

Head to Head Demo Comparison Sheet

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

Head to Head Demo Comparison Sheet

Preparation: Remove fuel tanks if vehicles are to be burned and chock wheels to prevent unexpected movement

Apparatus Placement. Was this fire apparatus placed properly?

Innovative Firefighting Products

Dispatching Apparatus and Personnel

Driver/Operator - Mobile Water Supply

Le Claire Fire Department Le Claire, Iowa. Rural Water Supply Opera9ons Seminar 2- hr Water Supply Drill March 29, 2015 Summary Report

Gaining Access. Exploring and alternative to drafting

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C

Basalt Fire-Rescue Engine 43 Inspection

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

SOUTH DAKOTA FIREFIGHTERS ASSOCIATION OFFICIAL EVOLUTION RULES

Turbo Draft Flow Tests

Standardization of Fire Apparatus

Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

8296 Portable Monitor Operating & Maintenance Instructions

Suction Elbow Flow Performance Tests

Certification Guide Apparatus Equipped with Fire Pump

Driver Operator Aerials: Maintenance and Testing. 4 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Lakes Region Mutual Fire Aid Meredith, New Hampshire. Rural Water Supply Opera?ons Seminar 2-hr Water Supply Drill May 6, 2018 Summary Report

DATE Updated November 30, 2007

ADO-Aerial Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

Fire Apparatus Operator: Mobile Water Supply. 9 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus. Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition)

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire

OPERATIONS / TRAINING

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER

Glendale Fire Department

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

Position Number Community Division/Region Yellowknife North Slave

Engine Company Operations

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial

High Rise Fire Pumps CM/CGV Series, CMU/CGV Series. Operation and Maintenance

SCENARIO 8. Propane Fueled Delivery Truck Fire INCIDENT OVERVIEW

RAPID INTERVENTION TEAM STANDARD OPERATING PROCEDURES

Transcription:

INSTRUCTOR GUIDE TOPIC: BACK TO BASICS: ESTABLISHING SUPPLY LINES TIME REQUIRED: THREE HOURS MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12 ================================================================= PREPARATION: MOTIVATION: One important activity on the fireground is the ability to move water from the source to where it is needed. All the water in the world will not control or extinguish a fire if it cannot be moved quickly and efficiently. In areas without a pressurized water system, this becomes more critical. OBJECTIVE (SPO): The firefighter will demonstrate a working knowledge of supplying water to the fireground and, by participation and observation, the various appliances, hose layouts, and procedures involved in supplying water at an emergency scene. OVERVIEW: ESTABLISHING SUPPLY LINES * Supply line evolutions * Supplying water from various sources

ESTABLISHING SUPPLY LINES SPO EO 1-1 EO 1-2 The firefighter will demonstrate a working knowledge of supplying water to the fireground and, by participation and observation, the various appliances, hose layouts, and procedures involved in supplying water at an emergency scene. Describe the various hose evolutions used to supply water to the fireground. Demonstrate supplying water for fireground operations from various sources. 2 2

The purpose of this drill is to review and build on basic skills with the emphasis on improving efficiency and teamwork. It is assumed that the participants have some basic knowledge of the subject matter. The focus of the drill should include personal and team safety. The drill should include minimal instruction and maximum skills practice. The drill should also be conducted with the normal staffing that would respond on an engine on a structure assignment. I. SUPPLY LINE EVOLUTIONS (1-1) A. Straight Lay 1. Supply line is laid from the water source to the emergency scene 2. If threaded couplings are used, a female connection is needed if the hose is to be connected to a hydrant 3. Hydrant valve may be connected to end of supply hose and connected to the hydrant B. Reverse Lay 1. Supply line is laid from the scene to the water source 2. If threaded couplings are used, a male connection is needed to connect to a siamese for a standpipe or sprinkler system or another engine at the scene 3. If the engine is laying hose to a hydrant, a soft sleeve, hard sleeve, or section of supply line can be used to connect to the hydrant 4. If water is being taken from a static source, it will require setting up for draft C. Split Hose Lays 1. Combination of a forward lay and a reverse lay 2. Utilizes two pumpers to complete 3. May require a double female or a double male to connect, dependent on how the supply line is loaded on the engine and the couplings at the end of each hose D. Review Various Hose Lays and Means of Obtaining Water 1. Laying a single supply line from the hydrant to the scene a. Remove the amount of hose necessary to reach hydrant along with any adapters and a hydrant wrench b. Once the hose is secured against the hydrant, signal the apparatus driver that it is safe to move the engine c. Connect to the hydrant using the 4-1/2-inch steamer connection (LDH) or one of the 2-1/2-inch connections (2-1/2-inch or 3-inch) 3 3

d. If a hydrant valve is to be used, connect the hydrant valve to the steamer connection e. Open the hydrant completely and back off one-half turn f. If a supply engine is to be used, connect the supply line to the supply engine g. At the scene, the driver or other designated person will disconnect the supply line and connect it to the intake on the pump panel 2. Laying dual lines of 2-1/2-inch or 3-inch supply line from the hydrant to the scene a. Remove the amount of hose necessary to reach the hydrant along with any adapters and a hydrant wrench b. Once the hose is secured against the hydrant, signal the apparatus driver that it is safe to move the engine c. Connect to the hydrant using the two 2-1/2-inch hydrant connections d. If a hydrant valve is to be used for one of the lines, connect the hydrant valve to the steamer connection and the other line to one of the 2-1/2-inch connections e. Open the hydrant completely and back off one-half turn f. If a supply engine is to be used, connect the supply lines to the supply engine g. At the scene, the driver or other designated person will disconnect the supply lines and connect them to the intake on the pump panel 3. Laying a single LDH line from the scene to the water source a. Remove the coupling along with sufficient hose to reach the attack pumper or siamese as well as any adapters needed b. Once the hose is secured to a fixed object, signal the apparatus driver that it is safe to move the engine c. Connect the hose to the intake on the attack engine or the siamese on the sprinkler or standpipe system d. At the water source, the engine will be set up to receive water from a hydrant or a static draft source 4. Laying dual lines of 2-1/2-inch or 3-inch supply line from the scene to the water source a. Remove the coupling along with sufficient hose to reach the attack pumper or siamese as well as any adapters needed b. Once the hose is secured to a fixed object, signal the apparatus driver that it is safe to move the engine 4 4

c. Connect the hose to the intake on the attack engine or the siamese on the sprinkler or standpipe system d. At the water source, the engine will be set up to receive water from a hydrant or a static draft source 5. Hydrant connection NOTE: Hard sleeves can be used for hydrant operations but they are designed for drafting operations and may not withstand the hydrant pressure a. Engine can connect to the streamer connection using a soft sleeve b. Engine can connect to the 2-1/2-inch connections using a section of supply line (2-1/2-inch to 5-inch) c. If a hydrant valve is used, the engine can connect to the hydrant valve using a soft sleeve (a separate supply line will be needed to connect the engine to the hydrant valve to boost the pressure in the supply line) d. If the steamer connection is used, a hydrant gate or ball valve can be connected to one of the 2-1/2-inch hydrant connections for later use as needed e. If the hydrant has plenty of water and pressure, the engine at the hydrant can connect to both the steamer and the 2-1/2-inch connections or two engines connect to the hydrant f. The hydrant should be opened and closed completely while backing off one-half turn when opening or closing 6. Setting up for draft a. Drafting can be done from any static water source including a portable tank b. Drafting involves the use of one or more sections of hard sleeve and some type of strainer device on the end of the hard sleeve c. The hard sleeve(s) should be connected and all connections are made air tight using a rubber mallet d. A strainer should be placed on the end of the hard sleeve that is to be placed in the water source (a low level strainer may be used with a portable tank) to prevent debris from damaging the pump e. The female connection on the hard sleeve should be connected to one of the steamer connections on the pumper (preferably one on either side of the pump rather than a front or rear intake) f. A rope should be attached to the strainer for later retrieval as well as to assist in keeping the strainer off the bottom of a pond, lake, or stream bed 5 5

g. If large quantities of water are needed and pumper capacity is insufficient, more than one pumper may be used at the water source with the water being pumped into a Siamese or gated Siamese 7. Water relay a. Involves the use of multiple pumpers to move water longer distances b. Begins at the water source with the supply pumper setting up at a hydrant or static source c. As each pumper to participate in the relay arrives, they begin laying hose from the supply pumper to the scene d. Each pumper participating in the relay should not generally lay more than 1,000 feet of hose to keep engine pressure down (lesser friction loss to overcome) e. The last pumper in the relay will supply water to the attack pumper f. Flow of water starts with the supply pumper g. Manifolds, water thiefs, or gated wyes may be used at the scene to provide water to more than one attack pumper 8. Rural operation with nurse tanker or portable tank a. Lay LDH, either 4-inch or 5-inch, from end of lane back to fire scene b. Manifold or wye used to distribute water at scene c. LDH supplied from portable tanks or nurse tanker d. Reduces need for extra apparatus at scene when not needed e. Provides mobility for moving water during shuttling operations II. SUPPLYING WATER FROM VARIOUS SOURCES (1-2) A. The student will perform the following evolutions using as many of the appliances described above as possible. There are other evolutions that could be considered depending on local need and capability. 1. Lay a supply line from a hydrant using LDH and hydrant valve, connect the hydrant valve to the hydrant, charge the supply line, connect another engine to the hydrant, and have the supply engine supply the attack engine through the hydrant valve. 2. Reverse lay from engine or Siamese to source and set up water supply from a pressurized source. 3. Using the reverse lay, set up water supply from a static source using LDH, to supply a second engine at the scene. 4. Using the split lay, set up water supply from a pressurized source using a single line to supply a second engine at the scene. 6 6

5. Set up water supply from a portable tank using multiple engines. The evolution should include one engine operating as the attack unit and another engine operating as the supply unit at the portable tank. One of the units will be required to set up the portable tank which can be filled from a hydrant or tanker. 6. Using a straight lay, set up water supply without a hydrant valve from a pressurized source using LDH while initiating supply from a booster tank. 7. Using a reverse lay, set up water supply from a static source to a master stream device using a single supply line while initiating supply from a booster tank. 8. Set up a relay involving at least three pumpers and using a static water source. The relay should flow at least 500 GPM. 9. Have one engine connect to the steamer connection on the hydrant while second engine connects to the 2-1/2-inch connections (a hydrant gate or ball valve may be used to avoid shutting down the hydrant to allow the second pumper to connect) B. All water will be discharged into a master stream device which is already set up or connected directly to the pump. C. These evolutions are designed to expose the student to various methods of supplying water at the fire scene. The student should already be familiar with the techniques involved in each evolution. What is being emphasized here is teamwork and operating efficiency. 7 7

REVIEW: ESTABLISHING SUPPLY LINES * Supply line evolutions * Supplying water from various sources REMOTIVATION: Some of these evolutions can be performed by a single department while others may require assistance from neighboring departments. The drill provides an opportunity for interdepartmental drill that will benefit everyone. If the movement of water is not practiced on a regular basis, it will not be quick and efficient when needed. It is also an opportunity to develop or update procedures and practice some segments of the incident command system. ASSIGNMENT: ================================================================= EVALUATION: 1