Fusible Link (replaceable) Horizontal Mount

Similar documents
Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Fire Dampers Catalogue

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

MODEL 151B FIRE DAMPER

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

HCD-230 Industrial Control Damper

CURTAIN TYPE FIRE DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

table of contents PRODUCT SUMMARY 2

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Motorized Fire Dampers

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Fire, Smoke, and Combination Fire Smoke Dampers

Model VCD-20 3V CONTROL DAMPER

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

SD-1250 and SD-1600 Series Smoke Dampers

MULTI-BLADE FIRE DAMPERS

Installation, Operation and Maintenance Instructions

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

MULTI-BLADE FIRE DAMPERS

Smoke Dampers. Installation Instructions

VCD-23. Flange Options. Size Limitations

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

SMOKE DAMPER - CLASS F MODEL BMSD

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

VCD-23 Low Leakage CONTROL DAMPER

AMD-33 Air Measuring Station with VCD-33 Control Damper

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Installation, Operation and Maintenance Manual

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

VCD-23. Low Leakage CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Part # Installation,Operation and Maintenance Instructions

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

BC 03. Fire Dampers FD-GB-30-AS LISTED

AIR DUCT ACCESSORIES

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

LLOYD INDUSTRIES INC.

CFSD Series. Product Description

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

INSTALLATION INSTRUCTIONS MODEL KFD-555

Model VCD-43 Extruded Airfoil Blade Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Standard Installation Fire Damper Models: 319, 319(SS), D39

Installation, Operation and Maintenance Manual

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F:

Propeller Hooded Roof Fans

High Capacity Ventilation

Installation, Operation, and Maintenance Instructions

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

HVAC Control & Balancing Dampers

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Nobody delivers dampers and louvers faster!

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

CEILING & INLINE/CABINET VENTILATORS

Transcription:

Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a /2 hour UL fire damper label. UL 555 classifies static rated fire dampers for use in HVAC systems that are automatically shut down in the event of fire. Ratings UL555S Fire Resistance Rating Fire Rating: /2 hours Model FD-50 Static Rated Fire Dampers /2 hour Fire Resistance Rating Construction Standard Optional Frame Material Galvanized Steel* - Frame Depth 6 in. (94mm) Blade Material Galvanized steel* - Closure Spring Stainless Steel - Fusible Link 65 F (74 C) 22 F or 286 F (00 C) or (4 C) Mounting Vertical Horizontal * in gauges required by UL listing R-7 Options Sealed transitions (sleeve required) and sleeves Security bars POC retaining angles Transitions (B, B2, C, CO, CR, R) - * These dimension are furnished approximately /4 in. (6mm) undersize. Model FD-50 meets the requirements for fire dampers established by: National Fie Protection Association NFPA Standards 80, 90, & 0 International Building Code (IBC) New York City (MEA listing #260-9-M) California State Fire Marshall (CFSM) Listing #225-98:05 for use in walls Underwriters Laboratories Standard 555 (Listing R7) See complete marking on product. UL 555 Classification R7 Stainless Steel Closure Spring Fusible Link (replaceable) K side Horizontal Mount Installation All fire damper installations require the use of sleeves, angle, and methods described in Greenheck Fire Damper Installation Instructions (included with every damper shipment). s can be field fabricated or factory furnished as a complete damper/sleeve Installation instructions available at www.greenheck.com.

Factory Option FD-50 FD-50 fire dampers are available in factory furnished sleeves. s are galvanized steel and are available in 0 thru 20 ga. (mm -.5mm) thicknesses and lengths up to 6 in. (94mm). K dimension specifies location of damper within the sleeve. Minimum is 4 in. (02mm), maximum is sleeve length (L) minus 4 in. (02mm). This allows room for mounting angle installation and duct connection at each end of sleeve. If K dimension is not specific, it will be provided as one half of sleeve length L (damper centered in sleeve. Note: If using access doors, the door should be installed on the K side of the damper. Damper K Damper CL Damper Frame Location L Overall Length When sealed option is selected, B transitions will need to be field sealed in the area where duct to sleeve connection is made. Type B corner profile Type B with sleeve

FD-50 Type A Dampers larger than maximum single section size are The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Size Limitations Inches (mm) Single Section Vertical Type A Type B & B2 Minimum Maximum Minimum Maximum 4 x 4 (02 x 02) 48 x 48 (29 x 29) 4 x (02 x 76) 48 x 42 (29 x 067) Vertical* 96 x 48, 74 x 74 or 20 x 40 (248 x 29, 880 x 880 or 048 x 06) 96 x 42, 74 x 69 or 20 x 5 (248 x 067, 880 x 75 or 2048 x 889) Single Section Horizontal Horizontal* 4 x 4 (02 x 02) *Consult factory for number of sections. 48 x 48 (29 x 29) 96 x 48 or 20 x 40 (248 x 29 or 048 x 06) 4 x (02 x 76) 48 x 42 (29 x 067) 96 x 42 or 20 x 5 (248 x 067 or 048 x 889) Maximum Single Section Dimensions 2 Multi-Section Limitations Maximum height is 74 in. (880mm) when width is less than or equal to 74 in. (880mm). (Vertical mullion provided on dampers over 7 in. (940mm) wide and 48 in. (29mm) high. 48 in. (29mm) 48 in. (29mm) Reinforcement Rods 74 in. (880mm) 74 in. (880mm)

Dampers larger than maximum single section size are Maximum Single Section Dimensions FD-50 Type B & B2 42 in. (067mm) Type B Type B2 48 in. (29mm) 5 (27) 4 (02) 6 (52) 7 (940) 42 (067) 8 (965) 44 (8) 2 Multi-Section Limitations Maximum height is 69 in. (75mm) when width is less than or equal to 74 in. (880mm). (Vertical mullion provided on dampers over 7 in. (940mm) wide and 4 in. (092mm) high. 5 (27) 7 (78) 6 (52) 8 (20) 7 (78) 9 (229) 9 (99) 45 (4) 40 (06) 46 (68) 4 (04) 47 (94) 8 (20) 0 (254) 42 (067) 48 (29) 9 (229) (279) 4 (092) 49 (245) 0 (254) 2 (05) 44 (8) 49 (245) Reinforcement Rods 69 in. (75mm) (279) (0) 2 (05) 4 (56) (0) 5 (8) 45 (4) 49 (245) 46 (68) 50 (270) 47 (94) 5 (295) 4 (56) 6 (406) 48 (29) 52 (2) 5 (8) 8 (457) 49 (245) 5 (46) 6 (406) 9 (48) 50 (270) 54 (72) 7 (42) 20 (508) 5 (295) 55 (97) 74 in. (880mm) 8 (457) 2 (5) 9 (48) 22 (559) 20 (508) 2 (584) 52 (2) 56 (422) 5 (46) 57 (448) 54 (72) 58 (47) 2 (5) 24 (60) 55 (97) 59 (499) 22 (559) 26 (660) 56 (422) 60 (524) 2 (584) 27 (686) 57 (448) 6 (549) 24 (60) 28 (7) 58 (47) 62 (575) Damper /2 in. Varies /2 in. 25 (65) 29 (77) 26 (660) 0 (762) 59 (499) 6 (600) 60 (524) 64 (626) /4" 27 (686) (787) 28 (7) 2 (8) 29 (77) (88) 6 (549) 65 (65) 62 (575) 66 (676) 6 (600) 67 (702) 0 (762) 4 (864) 64 (626) 68 (727) (787) 6 (94) 65 (65) 70 (778) K Damper CL Damper Frame Location L Overall Length Type B side view K dim. Length Varies Type B2 side view 2 (8) 7 (940) (88) 8 (965) 4 (864) 9 (99) 5 (889) 40 (06) 66 (676) 7 (80) 67 (702) 72 (829) 68 (727) 7 (854) 69 (75) 74 (880) 6 (94) 4 (04) All multiple section dampers with B or B2 transitions, will include a factory installed sleeve. * Dimension in inches (mm). These dimensions are furnished 4 in. (6mm) undersize. (All H dimensions larger than 4 in. (092mm) are two sections high. The bottom section is a Type A and the top section is a Type B & B2.)

Dampers larger than maximum single section size are The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Inches (mm) Single section Vertical Vertical** Single Section Horizontal Horizontal** 4 in. (04mm) Maximum Single Section Dimensions 46 in. (68mm) Multi-Section Limitations Type CR Type CO & C Type R* Minimum Maximum Minimum Maximum Minimum Maximum 4 (04) 68 (727) 4 (04) T ype C T ype CO 4 in. (04mm) x (76 x 76) x (76 x 76) 46 in. (68mm) 46 x 4 (68 x 04) 94 x 4, 72 x 68 or 8 x 4 (288 x 04, 829 x 727 or 2997 x 864) 46 x 4 (68 x 04) 94 x 4 or 8 x 4 (288 x 04 or 2997 x 864) * With 2 in. (5mm) offset. Sizes adjust with 0 offset & in (25mm) offset. ** Consult factory for number of sections. C, CO, CR transitions are positioned from bottom of sleeve. Type CR in. (76mm) min. 4 in. (04mm) Type R in. (76mm) min. 72 in. (829mm) All multiple section dampers with transitions, will include a factory installed sleeve. FD-50 Type CR, CO, C & R 46 (68) 72 (829) 46 (68) Type CR Type CO Type C D* D*+2 +2 +2 or D* or D* or D* 6 (52) 25 (65) 0 (762) 47 (94) 52 (2) 4 (02) 7 (78) 26 (660) (787) 48 (29) 5 (46) 5 (27) 8 (20) 27 (686) 2 (8) 49 (245) 54 (72) 6 (52) 9 (229) 28 (7) (88) 50 (270) 55 (97) 7 (78) 0 (254) 29 (77) 4 (864) 5 (295) 56 (422) 8 (20) (279) 0 (762) 6 (94) 52 (2) 57 (448) 9 (229) 2 (05) (787) 7 (940) 5 (46) 58 (47) 0 (254) (0) 2 (8) 8 (965) 54 (72) 59 (499) (279) 4 (56) (88) 9 (99) 55 (97) 60 (524) 2 (05) 5 (8) 4 (864) 40 (06) 56 (422) 6 (549) (0) 6 (406) 5 (889) 4 (04) 57 (448) 62 (575) 4 (56) 8 (457) 6 (94) 42 (067) 58 (47) 6 (600) 5 (8) 9 (48) 7 (940) 44 (8) 59 (499) 64 (626) 6 (406) 20 (508) 8 (965) 45 (4) 60 (524) 65 (65) 7 (42) 2 (5) 9 (99) 46 (68) 6 (549) 66 (676) 8 (457) 22 (559) 40 (06) 47 (94) 62 (575) 67 (702) 9 (48) 2 (584) 4 (04) 48 (29) 6 (600) 68 (727) 20 (508) 24 (60) 42 (067) 49 (245) 64 (626) 70 (778) 2 (5) 26 (660) 4 (092) 49 (245) 65 (65) 7 (80) 22 (559) 27 (686) 44 (8) 49 (245) 66 (676) 72 (829) 2 (584) 28 (7) 45 (4) 50 (270) 67 (702) 7 (854) 24 (60) 29 (77) 46 (68) 5 (295) 68 (727) 74 (880) * Dimension in inches (mm). These dimensions are furnished 4 in. (6mm) undersize except round and oval dimensions are approximately 8 in. (mm) undersize. (All H dimensions larger than single section height are two sections high. Copyright 207 Greenheck Corporation FD-50 Rev. December 207