TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

Similar documents
FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Industry Cables Special cables for industrial applications General Catalogue

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

Chemical resistance Accidental

H07RN-F TITANEX PREMIUM

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Technical attributes

ENERGY. Solar Cables

Approvals (Norm references)

CRANE, CONVEYOR, LIFT & REELING CABLES

SY PVC / BS EN Control Flexible Cable

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

Global data. Electrical parameters

H07RN-F TITANEX (industrial flexible)

Power & Control Cable IEC

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

Power & Control Cable IEC

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

Power & Control Cable IEC

N2XY IEC XLPE PVC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire

N2XSEBY 3 x (25-300) mm² 3.6/6 kv


14 HH EAC/CTP CE RoHS-II conform

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

6491B / H07Z-R / BS EN Cable

CABLES FOR A MOVING WORLD TRATOS RENEWABLE ENERGY. Mar 2010 Tt 11-14

600/1000V, XLPE Insulated Cables according to IEC

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Technical Data Sheet Unshielded (YY) PVC Control Cable

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

New TITANEX PREMIUM. No limit!

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

Cables for cable carriers and reels SYSTEMS IN MOTION

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

RFOU 0.6/1kV Power Cable

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

ÖLFLEX CLASSIC 110 H Info Benefits

Photo: HELUKABEL. Trailing Cables G 1

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

BS6724 SWA/LSZH Cable IEC /1000V

LIST OF PUBLISHED STANDARDS

CF270.UL.D.

BFOU 0.6/1kV Power Cable

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

CFRIP - tear strip for faster stripping

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

Power & Control Cables

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

FLEX-O-POWER FLEXIBLE WELDING

Technical Data Sheet Shielded (CY) PVC Control Cable

Connecting globally. TFCrane

DNV-GL HH CE RoHS-II conform

ÖLFLEX CLASSIC 110 CY

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

PRODUCT INFORMATION H07V-K

Firetec BS 7846 LPCB BASEC Approved Power Cable

Cables for Railway Technology

N2XSERY 3 x (25-300) mm² 3.6/6 kv

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

SUBMERSIBLE PUMP CABLES

Telephone Cables Fire Warning Cables

FR-3S Fire Resistant Cables

Section 8. Portable Cordage & Power Cable

BS 6724 Armoured Power Cables, 600/1000V

flame Retardant overall screened Instrumentation cables (Multicore)

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45

FTTH simplex indoor cables with semi-tight tube

PANZERFLEX TUNNELFLEX C A B L E S

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813


Transcription:

Low voltage - Energy, cabling, signalling and control TRIFLEX H07RN-F Structure and, physical, mechanical requirements: Low Directive: RoHS Directive: EN 50525-2-21 2014/35/EU 2011/65/EU Standard: Class: reaction to fire EN 50575:2014+A1:2016 E ca Classification: EN 13501-6 Flame propagation: EN 60332-1-2 Notified Body: CPR COMPLIANT REGULATION 305/2011/EU 0051 - IMQ 2017 www.latrivenetacavi.com

Description Conductor: class 5, flexible, plain copper wire Insulation: rubber compound, EI4 quality Sheath: polychloroprene or equivalent synthetic elastomer, water resistence (AD6) Colour: black Functional characteristics Rated voltage Uo/U: 450/750 V a.c. (for fixed and installation 0,6/1 kv a.c.) operating : 60 C Min. operating : -40 C (without mechanical shocks) short circuit : 200 C In the case of fixed installation, the can be used up to 85 C. Special features Good flexibility and mechanical to abrasion, shocks, crushing and lacerations. Good to atmospheric agents, grease and mineral oils. UV-resistant. Use and installation method Reference Guide EN 50565: For mobile laying: indoor use, outdoor use and in industrial and agricultural workshops. For supplying industrial and agricultural machines and appliances subject to medium mechanical stresses (e.g. heating plates, inspection lamps, electric tools such as drills, circular saws and domestic electric tools). For fixed laying: it can be used in temporary buildings or huts in building sites. Suitable for connections of constructive elements of lifting appliances and machines. Suitable for use in dry, humid or moist rooms (AD6). If used in installations such as tubes or similar closed systems, voltages up to 1000V in a.c. or 750V in d.c. to ground are allowed. Reference Construction Products Regulation 305/2011 EU and Standard EN 50575: The is suitable for the supply of electricity in buildings and other civil engineering works. Installation conditions Minimum installation : -25 C Recommended minimum bending radius: 6 times the diameter for mobile use, 4 times for static use Recommended maximum tensile stress: 15 N/mm² of the cross-section of the copper for mobile use, 50 N/mm² for static use. Colours of the cores SINGLE-CORE TWO-CORE THREE-CORE or FOUR-CORE or FIVE-CORE or The cores in multiple s for signal and control are black, numbered, with or without GREEN/YELLOW Marking LTC IEMMEQU HAR TRIFLEX H07RN-F [formation] Eca 450/750V - Protected 600/1000V [order number] [year] Made in Italy [metric]

Single-core 1 x 1,5 1,5 0,8 1,4 7,1 13,3 50 16 23 26,5 1 x 2,5 2,0 0,9 1,4 7,9 7,98 65 20 32 16,0 1 x 4 2,5 1,0 1,5 9,0 4,95 89 30 43 9,93 1 x 6 3,0 1,0 1,6 9,8 3,30 120 38 56 6,63 1 x 10 4,0 1,2 1,8 11,9 1,91 180 53 77 3,87 1 x 16 5,0 1,2 1,9 13,4 1,21 250 71 103 2,47 1 x 25 6,2 1,4 2,0 15,8 0,780 350 94 130 1,61 1 x 35 7,4 1,4 2,2 17,9 0,554 470 117 162 1,17 1 x 50 8,9 1,6 2,4 20,6 0,386 650 148 199 0,844 1 x 70 10,5 1,6 2,6 23,3 0,272 870 185 257 0,609 1 x 95 12,2 1,8 2,8 26,0 0,206 1120 222 315 0,484 1 x 120 13,8 1,8 3,0 28,6 0,161 1400 260 368 0,388 1 x 150 15,4 2,0 3,2 31,4 0,129 1425 300 426 0,325 1 x 185 16,9 2,2 3,4 34,4 0,106 2090 341 490 0,279 1 x 240 19,5 2,4 3,5 38,3 0,0801 2660 407 583 0,221 1 x 300 21,6 2,6 3,6 41,9 0,0641 3280 468 675 0,184 1 x 400 24,8 2,8 3,8 46,8 0,0486 4230 553 790 0,159 1 x 500 28,5 3,0 4,0 52,0 0,0384 5230 620 908 0,137 1 x 630 32,8 3,0 4,1 57,0 0,0287 6780 742 1044 0,122 - three-phase circuit Two-core 2 x 1 1,3 0,8 1,3 10,0 19,5 97 10 18 45,2 2 x 1,5 1,5 0,8 1,5 11,0 13,3 120 16 23 30,6 2 x 2,5 2,0 0,9 1,7 13,1 7,98 170 25 32 18,4 2 x 4 2,5 1,0 1,8 15,1 4,95 230 34 43 11,4 2 x 6 3,0 1,0 2,0 16,8 3,30 300 43 56 7,63 2 x 10 4,0 1,2 3,1 22,6 1,91 520 60 77 4,44 2 x 16 5,0 1,2 3,3 25,7 1,21 720 79 102 2,84 2 x 25 6,2 1,4 3,6 30,7 0,780 1030 105 136 1,85 2 x 35 7,3 1,4 3,7 34,3 0,554 1290 120 168 1,34 - two-phase circuit for two-core s

Three-core 3G1 1,3 0,8 1,4 10,7 19,5 120 10 18 45,2 3G1,5 1,5 0,8 1,6 11,9 13,3 145 16 23 30,6 3G2,5 2,0 0,9 1,8 14,0 7,98 205 25 32 18,4 3G4 2,5 1,0 1,9 16,2 4,95 280 35 43 11,4 3G6 3,0 1,0 2,1 18,0 3,30 375 44 56 7,63 3G10 4,0 1,2 3,3 24,2 1,91 645 60 77 4,44 3G16 5,0 1,2 3,5 27,6 1,21 890 82 102 2,84 3G25 6,2 1,4 3,8 33,0 0,780 1280 109 136 1,85 3G35 7,4 1,4 4,1 37,1 0,554 1660 135 168 1,34 3G50 8,9 1,6 4,5 42,9 0,386 2300 169 203 0,962 3G70 10,5 1,6 4,8 48,3 0,272 3060 211 254 0,691 3G95 12,2 1,8 5,3 54,0 0,206 3945 250 299 0,546 3G120 13,8 1,8 5,6 60,0 0,161 4905 290 363 0,438 3G150 15,4 2,0 6,0 66,0 0,129 6060 332 416 0,366 3G185 16,9 2,2 6,4 72,0 0,106 7330 375 475 0,220 3G240 19,5 2,4 7,1 82,0 0,0801 9500 447 575 0,210 3G300 21,6 2,6 7,7 90,0 0,0641 11750 509 665 0,180 also available without the green/yellow - three-phase circuit for three-core s

Four-core 4G1 1,3 0,8 1,5 11,9 19,5 145 10 16 39,0 4G1,5 1,5 0,8 1,7 13,1 13,3 175 16 21 26,5 4G2,5 2,0 0,9 1,9 15,5 7,98 250 20 29 16,0 4G4 2,5 1,0 2,0 17,9 4,95 345 30 38 9,93 4G6 3,0 1,0 2,3 20,0 3,30 465 37 50 6,63 4G10 4,0 1,2 3,4 26,5 1,91 790 52 68 3,87 4G16 5,0 1,2 3,6 30,1 1,21 1100 69 92 2,47 4G25 6,2 1,4 4,1 36,6 0,780 1610 92 122 1,61 4G35 7,4 1,4 4,4 41,1 0,554 2090 114 150 1,17 4G50 8,9 1,6 4,8 47,5 0,386 2900 143 182 0,844 4G70 10,5 1,6 5,2 54,0 0,272 3880 178 232 0,609 4G95 12,2 1,8 5,9 61,0 0,206 5050 210 281 0,484 4G120 13,8 1,8 6,0 66,0 0,161 6230 246 325 0,388 4G150 15,4 2,0 6,5 73,0 0,129 7720 280 373 0,325 4G185 16,9 2,2 4,2 80,0 0,106 9360 330 424 0,280 also available without the green/yellow - three-phase circuit Five-core 5G1 1,3 0,8 1,6 13,1 19,5 175 10 16 39 5G1,5 1,5 0,8 1,8 14,4 13,3 210 16 21 26,5 5G2,5 2,0 0,9 2,0 17,0 7,98 305 20 29 16,0 5G4 2,5 1,0 2,2 19,9 4,95 420 30 38 9,93 5G6 3,0 1,0 2,5 22,2 3,30 575 38 50 6,63 5G10 4,0 1,2 3,6 29,1 1,91 960 54 68 3,87 5G16 5,0 1,2 3,9 33,3 1,21 1350 71 92 2,47 5G25 6,2 1,4 4,4 40,4 0,780 1955 94 122 1,61 5G35 7,4 1,4 4,6 45,1 0,554 2520 114 150 1,17 5G50 8,9 1,6 5,2 53 0,386 3530 143 182 0,844 5G70 10,5 1,6 5,7 60 0,272 4760 178 232 0,609 5G95 12,2 1,8 6,3 67 0,206 6160 210 281 0,484 also available without the green/yellow - three-phase circuit

Multi-core / signalling and control 7G1,5 1,5 0,8 2,5 17,2 13,3 335 11 16 30,7 12G1,5 1,5 0,8 2,9 22,4 13,3 500 9 14 30,7 19G1,5 1,5 0,8 3,2 26,3 13,3 720 8 13 30,7 24G1,5 1,5 0,8 3,5 30,7 13,3 915 7 12 30,7 36G1,5 1,5 0,8 3,8 35,2 13,3 1305 5 10 30,7 7G2,5 2,0 0,9 2,7 20,0 7,98 470 15 19 18,4 12G2,5 2,0 0,9 3,1 26,2 7,98 705 12 16 18,4 19G2,5 2,0 0,9 3,5 30,9 7,98 1030 10 14 18,4 24G2,5 2,0 0,9 3,9 36,4 7,98 1320 9 13 18,4 27G2,5 2,0 0,9 4,0 37,1 7,98 1450 7 11 18,4 36G2,5 2,0 0,9 4,3 41,8 7,98 1880 7 11 18,4 also available without the green/yellow - all s are charged (except for the green/yellow).