SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Similar documents
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Publication No.: PSG

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Submersible Vacuum Fault Interrupters

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Three-Phase Pole Mounted Recloser

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Medium Voltage Metal-Enclosed Switches

University of Houston Master Construction Specifications Insert Project Name

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Underground Distribution Switchgear

Horizontal Circuit Switchers

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Switchgear Skid, C1192

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Electrical Switchgear Replacement Montgomery County Community College

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

SWITCHGEAR DIVISION PRODUCT PROFILES

Typical Specification

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Horizontal Circuit Switchers

Medium Voltage Metal-Enclosed Switches

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

SECTION III - VACUUM CIRCUIT BREAKER TECHNICAL SPECIFICATIONS TABLE OF CONTENTS 1. SCOPE PROJECT ENGINEER STANDARDS...

COOPER POWER CA280012EN

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

Type SDV7 distribution circuit breaker family

A. Submit manufacturer's literature and technical data before starting work.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Contents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

S&C Type FVR Substation Circuit Breaker

SECTION PADMOUNT TRANSFORMER - OIL FILLED

Underground Distribution Switchgear

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

SECTION III SF6 GAS CIRCUIT BREAKER TECHNICAL SPECIFICATIONS TABLE OF CONTENTS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

BGE STRATEGIC CUSTOMER ENGINEERING

Type SDV7 distribution circuit breaker family Answers for energy.

C1000 Series Automatic Cap Bank

SECTION V - TECHNICAL SPECIFICATIONS TABLE OF CONTENTS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

100 / 110 DRYWELL FUSE SPECIFICATION

Design Standard. Purpose: Design Standard:

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

University of Houston Master Construction Specifications Insert Project Name

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Solid Dielectric, Three Phase Reclosers CATALOG VS11

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Acknowledge receipt of this addendum on page one of the Bid Form.

Extensible Unit - VCE2a

City of Jacksonville Beach

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Cobra-S. Catalog Cobra-S

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

S&C Manual PME Pad-Mounted Gear

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Solid Dielectric, Single Phase Recloser

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

Solar Power Switchgear & Energy Storage Renewable Energy Systems

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

SECTION PANELBOARDS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Underground Distribution Switchgear

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

C. System Design and Performance Requirements

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Solid Dielectric, Single Phase Reclosers

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

MEDIUM VOLTAGE SWITCHGEAR SECTION

Capital Projects Group Metal-Clad Switchgears Specification

SECTION MOTOR CONTROL

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Transcription:

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities and other high demand industries. By combining the latest developments in circuit breaker technology with worldrenowned quality, the Powersub Type FVR Vacuum Substation Circuit Breakers from Myers Controlled Power are the most advanced medium-voltage circuit breakers available. Part 1: General This specification applies to an outdoor, three pole, single throw, free standing, 15.5 kv vacuum circuit breaker. A. References ANSI/IEEE C37.20.2 - Standard for Metal-Clad and Station-Type Cubicle Switchgear. ANSI/IEEE C37.04 and.06 - Standard ratings and preferred ratings for Class S2 Outdoor AC Medium-Voltage Circuit Breakers. ANSI/IEEE C37.11 - Requirements for electrical control for AC High-Voltage Circuit Breakers rated on a symmetrical current basis or a total current basis. ANSI/IEEE C37.09 - Standard Design and Production Testing ANSI Z55.1 - Gray Finishes for Industrial Apparatus and Equipment. ANSI/IEEE C57.13 - Requirements for Instrument Transformers. NEMA SG4 - Alternating Current High Voltage Circuit Breakers. B. Submittals Submit shop drawings indicating outline dimensions, enclosure construction, shipping splits, lifting and supporting points, electrical single line diagram, and equipment electrical ratings. C. Operation and Maintenance Data Include circuit breaker recommended spare parts list. D. Quality Assurance Qualified manufacturer shall be a company specializing in medium voltage substation vacuum station breakers with at least five years documented experience. The breaker shall be manufactured in a facility that is Quality Systems Registered by Underwriters Laboratories, Inc. to ISO 9001. Substation Vacuum Circuit Breaker (15KV) Page 1

E. Delivery, Storage, and Handling The items below apply to the installing contractor only. Accept equipment on site and inspect for shipping damage. If circuit breaker is stored before being put into operation, protect equipment from weather and moisture. Maintain heat within enclosure in accordance with manufacturer's instructions. Part 2: Products A. Manufacturers The vacuum station breakers shall be manufactured by Myers Controlled Power. B. Station Breaker Ratings The breaker shall meet the following ratings and electrical characteristics: Characteristic Required Maximum Voltage Insulation Level Low Frequency (Dry, 1 Minute) Impulse Crest (Fullwave) Impulse Crest (Chopped Wave, 2 Microsec.) Impulse Crest (Chopped Wave, 3 Microsec.) Rated Continuous Current Rated Short Circuit Current Rated Interrupting Time Rated Reclosing Time Rated Permissible Tripping Delay, Y Rating 15.5kV, RMS 50kV, RMS 110kV, RMS 142kV, RMS 126kV, RMS [ ]* Amps (Specify 600, 800, 1200, 2000, 3000, 3500, or 4000) [ ]*ka, RMS (Specify 12.5, 16, 20, 25, 31.5, 40, or 50) 3 cycles 18 cycles 2 seconds Max. Symmetrical Interrupting Current [ ]* ka, RMS 3-Second Short Time Current Rating [ ]* ka, RMS Duty Cycle O -.300s CO 15s - CO Closing Control Voltage [ ]V (DC)(AC) Substation Vacuum Circuit Breaker (15KV) Page 2

Characteristic Tripping Control Voltage Motor Voltage Rating (Specify 48,125,250VDC or 120,240VAC) [ ]V (DC)(AC) (Specify 24,48,125,250VDC or 120,240VAC) [ ]V (DC)(AC) (Specify 48,125,250VDC or 120,240VAC) Heater Voltage (*) Refer to rating selection table below. (**) If system application requires 20 cycles, user to specify an auxiliary timing relay C. FVR Circuit Breaker Rating Selection Table [ ]VAC (Specify 120 or 240VAC) kv BIL Ka, RMS Cont. Current Short Circuit, 3-Second & Sym. Interrupt. Close and Latch (peak) 600A 12.5 32 800A 16 43 1200A 20 54 110 2000A 25 68 3000A 31.5 85 3500A 40 108 4000A 50 130 The breaker shall be rated for an ambient temperature range of 30 degrees to +40 degrees Celsius. A 50 degrees to +40 degrees Celsius rating is optional. The breaker shall be rated for Seismic Zone 4. The breaker shall be rated to withstand a minimum wind load of 90 mph imposed upon the structure supporting the terminal connection. A 150mph rating is optional. The breaker shall be rated for use at altitudes up to 3300 ft. above sea level without derating. For altitudes higher than 3300 ft., the rated dielectric strength and rated maximum voltage and current shall be multiplied by altitude correction factors to obtain values at which applications may be made. Substation Vacuum Circuit Breaker (15KV) Page 3

D. Fabrication Mechanical construction requirements are as follows: For continuous current ratings of 2000A and below, the enclosure shall be ARC- RESISTANT design, based on EEMAC standards. The enclosure shall be weatherproof and designed in a modular construction isolating line potential components from secondary control devices. The high voltage compartment shall house the vacuum interrupter assemblies supported on standoff insulators. The enclosure shall be provided with lifting eyes for lifting the entire unit during loading and unloading. The breaker shall be shipped completely assembled. Breakers shall not be shipped with legs unattached. Ground pads, 2 x 3.5 with provisions for NEMA 2-hole connectors, shall be welded on each side of the enclosure for external ground connections. #4 cables from the roof and HV & LV compartments shall be connected internally to the ground pads to insure a solidly grounded enclosure, with negligible difference in ground potential between compartments. Enclosure grounding shall not depend on bolted connections or star washers. The breaker legs shall be painted and have an adjustable height range of 24 inches in three inch increments. Total height of breaker shall vary from 101.88 minimum to 125.88 maximum. Leg assemblies shall have a galvanized base channel. Outer doors shall have padlockable handles for preventing access to all controls in the enclosure. Doors are to be gasketless and vertically hinged. Provisions for holding all doors in the open position 180 degrees shall also be provided. It shall be documented that the breaker passed rain testing. The low voltage cabinet bottom shall have an 8 x 14 removable cover for entrance of user s control conduit. Conduit entry location shall be clearly marked on detail drawings. All external hardware shall be stainless steel. E. Components E.1 Interrupter The vacuum interrupters shall be hermetically sealed in protecting contacts from moisture and contaminated atmosphere. The interrupters shall be rated for K = 1.0 duty. The interrupters shall be maintenance free. Circuit breaker shall have readily accessible provisions for measuring the contact wear for each pole. Substation Vacuum Circuit Breaker (15KV) Page 4

E.2 Operating Mechanism The mechanism shall be spring-charged stored-energy with electrical charging motor. The mechanism and control circuits shall be located in the low voltage compartment. The mechanism shall not be mounted in a separate housing. The mechanism shall be designed with an integral, manual charging handle. Charging handle shall not be removable. The mechanism shall be mechanically and electrically trip free and non-pumping for both manual and automatic operations. The following shall be clearly visible on the mechanism when the outer door is closed: A non-resettable, mechanical five-digit operation counter which increases on each trip operation A mechanical indicator to indicate the open and closed positions of the circuit breaker. A mechanical indicator to indicate the status of the closing springs. Open and close push-buttons for operating the breaker. The standard design shall have a 12 contact auxiliary switch, of which five with DC control and six with AC control, are used for internal breaker wiring. When specified, an additional auxiliary switch with six a and six b contacts shall be provided for external use. The mechanism shall be designed with a latch-check switch as standard. When specified, the mechanism shall be equipped with a dual-trip coil. E.3 Bushings Six (6) roof bushings shall be provided. The material shall be porcelain and ANSI # 70 light gray in color. Bushing terminals shall be threaded stud type and capable of accepting either 4-hole NEMA stud to flat connectors (Type FD) or stud to cable connectors (Type NDR). Connectors shall be sized per user s cable size and # of cables per phase. Bushings shall have a minimum rating of 15.5kV, 110kV BIL. Minimum bushing creepage distance shall be 24.5. When specified, 5-tap, multi-ratio current transformers shall be supplied for each bushing. Ratio and accuracy are to be determined by the user. All secondary leads shall be terminated on short-circuit type terminal blocks in the low voltage compartment and can be accessible at all times with the breaker energized. Each bushing shall be capable of mounting three standard-accuracy, two double-accuracy, or one triple-accuracy 1200:5 multi-ratio CT. E.4 Controls Control wire shall be #14 AWG Type SIS for general control and #12 AWG Type SIS for CT circuits. Wire color shall be gray. Terminal blocks for control circuits and user s external connections shall be provided with terminal marking strips labeled in accordance with the wire diagrams. Substation Vacuum Circuit Breaker (15KV) Page 5

When required, short circuit terminal blocks shall be provided with shorting screws and common shorting bar for each individual current transformer. Control circuit shall be provided with fused switches or low voltage circuit breakers for disconnecting external low voltage supply circuits. An anti-pump relay shall be provided to inhibit multiple close-open operations in the event that a continuous close signal is applied. One pistol grip control switch, Electroswitch Series 24, engraved TRIP-CLOSE shall be supplied. Red and green indicating lamps for closed or open status of the breaker shall be supplied. Space heaters, rated 240VAC, shall be supplied to prevent moisture condensation in the breaker enclosure. Heaters shall be thermostatically controlled and located in the low voltage compartment. The heater control circuit shall be provided with fused switches or low voltage circuit breakers for disconnecting external low voltage supply circuit. An emergency manual trip, ANSI Device Number 69, shall be provided and shall be readily accessible on the exterior mechanism side of the breaker. It shall be labeled MANUAL TRIP OPEN and the actuating handle shall be painted red. The device shall be operable from the exterior of the breaker without the necessity of opening any doors, panels, etc. Actuation of the device will block any electrical closing of the breaker until the switch has been manually reset. E.5 Factory Finishing The enclosure shall be painted ANSI #70 light gray with a TGIC polyester powder coat protective paint finish. Total paint thickness on exterior surfaces shall be 3.0 mils. Production samples shall have passed 2,500 hours minimum of salt spray testing per ASTM B-117 and ASTM D-1654 Procedure A with a rating of 6 or higher. Part 3: Execution A. Examination Visually inspect circuit breaker for evidence of damage and verify that surfaces are ready to receive work. Visually inspect to confirm that all items and accessories are in accordance with specifications and drawings. Verify field measurements are as [shown on drawings] [shown on shop drawings] [instructed by manufacturer]. Verify that required utilities (e.g., control voltage for heater circuits on outdoor switchgear) are available, in proper location, and ready for use. Beginning of installation means installer accepts existing surface conditions. Substation Vacuum Circuit Breaker (15KV) Page 6

B. Installation Install in accordance with manufacturer's instructions, applicable requirements of the NEC and in accordance with recognized industry practices. C. Field Quality Control Field inspection and testing will be performed by [the installing contractor] [a separate contractor furnished by the owner]. Visually inspect for physical damage. Perform start-up tests in accordance with manufacturer's instruction manual. Perform low-frequency withstand (Hi-Pot) tests in accordance with ANSI/IEEE C37.20.2. Substation Vacuum Circuit Breaker (15KV) Page 7