QuickFit Filter Purge, Oil Evacuation & Refill System

Similar documents
CEX-32 LARGE CAPACITY, HEAVY DUTY ENGINE COOLANT EXTRACTION AND RE-FILLING SYSTEM

#9040 FUEL TANK SWEEPER

MOTORVAC. BrakeVac-II. MODEL NUMBER Brake Fluid Service System. Operator Manual MotorVac

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

STATIONARY GREASE PUMP PACKAGES. Model PM grease pump package for 120 lb kegs lb drum cover 966 Follower plate for 400 lb drum

FAULT CODE 482. Fuel Pressure Low - Data Valid but Below. Operational Range - Moderately Severe Level.

REMCO Towing Training and Service for Lube Pump Systems

High Pressure Leak Diagnostics System Part No & NA USER MANUAL LEAK DETECTION SERVICE

Operating Manual Model 3023

Lube PUMP PACKAGES. pumpmaster 3+3 and 6

CenterFlo Pumps. Air Operated Double Diaphragm (AODD) Pumps. Automotive Commercial Industrial

Every Track. Cummins Engines For Rail Applications hp ( kw)

Dynaswivel. Air Line Connectors. Ball-Swivel Plug. Never Fight an Air Tool Again! For Use with Most Air Tools THE PROBLEM THE SOLUTION

BrakeVac-II Brake Fluid Service System

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

Ultra-Matic Air Valve System

MODEL NO. TSSK GALLON SKID-MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Engine Performance Troubleshooting Tree - Signature and ISX CM870

08 WASTE OIL EQUIPMENT

Model Model 815

Sumake WH 202A Auto Transmission Exchanger

Fuel System Diagnosis

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

EVERY JOB. QSL FOR OFF-HIGHWAY APPLICATIONS

348002K/348012K Manifold Block Style Service Manual 12/2000

AEROMOTIVE Part # HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS

Troubleshooting WARNING

Solenoid Operated Block Valves A2800 Series

PF Series Thermoplastic Non-Spill Couplings and Industrial Hose Products

Engine Performance 1500 RPM

To ensure proper installation, digital pictures with contact information to before startup.

Automatic Transmission Exchange Machine

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

OPERATION MANUAL ESX-2

Automatic Lubrication Solutions Saving You Time and Increasing Productivity

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND

Crankcase Ventilation Manager (CVM) Installation Instructions

Operating Manual. High Performance Vacuum Pump Models and 15600

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

Industrial Pumping Equipment PileDriver III Series III Air Motor Features

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Technology That Transforms. High-Performance Engines For Mining Equipment.

2062 ½ NPTM x ¼ NPTF bushing ½ NPTM x 3/8 NPTF bushing ½ NPTM x 3/8 NPTF bushing

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

INDUSTRIAL DIESEL TUNE SYSTEM

Model Model Model 3650 Model 3614

Ready For More. Underground. Underground Mining Engines.

12CS/50CS Series. Coreless Spin-on Filters

Cobett Company th Street East Peru, Iowa WB1117

Tank Filling Systems. for Petroleum Products

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

MAX FLUID TEMPERATURE

Regulated Hose Supply Installation, Operation & Maintenance Manual

VACUUM PUMP P5010. Profit from new vacuum technology

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

08 general Purpose Pumps

Industrial Pumping Equipment PowerMaster III

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

OPERATOR S MANUAL FUEL TANK SWEEPER #9040PN

DPS280 / DVS280 Series

BrakeVac EBB1000 Brake Service System

FAULT CODE 132 (SSS) Accelerator Position Sensor Circuit

Bellows Pumps. The Newest Technology in Piston Pumps

Model Model Model

12CS/50CS Series Coreless Medium Pressure Filters

Combustion Technologies By-Pass Filtration Instructions

LT Series Lubricant Management System (LT-LMS)

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

12 Volt DC Diaphragm Pumps Series 400

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

BENECOR DEF CENTRIFUGAL PUMP

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SF 6 Gas Reclaimers Zero Emissions. No Substitutes.

Tank Filling Systems for Petroleum Products

91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE

Every Track. Cummins engines for rail applications hp ( kw)

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

Mobile Lube Equipment

MODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

3" Elima-Matic Pumps. Air-Operated Double Diaphragm Pumps

Cleaning Systems Inc. 2 P Rev:03

TurboWerx Spartan-series TWX V Electric Scavenge Pump

Brake Fluid Exchange

Installation Manual v2.2: Twin CP3 Fuel Injection Kit Dodge 5.9L

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

M4 Troubleshooting 42

Ultra-low sulphur diesel (15 ppm sulphur)

Installation, Operation & Maintenance Manual

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

DF-200 w/adjustable Regulator INSTALLATION MANUAL. CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH 1998

Ink Manufacturing and Printing Solutions

Doosan XHP1070WCAT Bid Specifications

P239-1 Supply Pumper Instructions

Transcription:

Specification sheet QuickFit Filter Purge, Oil Evacuation & System Description The QuickFit system transforms the way service is performed today. For most engines, a complete engine oil and filter change can be performed in under 10 minutes, with a full service change in 30-40 minutes. With the reduction in labor-hours, the system pays for itself in 1-2 services. Filters are purged to eliminate hot oil spills and automatically filled with new, fully-filtered oil for complete contamination control. Productivity goes up and the risk of spills and contamination is virtually eliminated. Benefits: - 60-70% labor savings - 80% reduction in safety hazards - Zero Spill Oil Change - Increased technician capacity - Applicable to most engine arrangements Operation Three steps for safer, cleaner and faster oil changes: Purge Connect the purge tool to the compressed air source and to the QuickFit valve to purge dirty oil from lube filters into the sump. Remove old filters without any spills for easy, clean disposal. Install new filters empty. Evacu ate Connect the suction line to the QuickFit valve to drain dirty oil from the sump directly into the waste container. - Connect the clean oil supply to the QuickFit valve to fill empty filters, removing any contamination from new oil and pre-lubricating the engine before starting. Features No Leak Solution The QuickFit system uses dual check valves and metal reinforced hoses to negate any possibility of leakage from the engine. Live Dipstick Read from Ground QuickFit process fully pressurizes engine as part of the fill process. The system delivers a "live" dipstick read without requiring the technician to climb up, start the machine, shut down the machine, then climb down to verify fluid levels. Contamination and Spill Control The QuickFit system pumps oil directly from the engine into a final waste container, which ensures that no oil touches the ground, the machine, or the PM tech. All quick disconnect fittings are flush face, drip-proof design. This eliminates environmental concerns and provides a safer work environment for the service techs. In addition, because the QuickFit system allows engine refill via the new filter(s), new oil is fully filtered for improved contamination control. Groun d Accessib ility Statistics reveal that 30-35 percent of injuries on heavy equipment occur when people climb on or off machinery. Because QuickFit components are ground accessible, technicians spend far less time climbing on or under machines during routine maintenance. Automatic Engine Lubrication After the service, the QuickFit system ensures proper oil pressure and pre-lubricates the engine during the start, before the engine is allowed to crank. Warranty This product has a five year or 5000 hours warranty, whichever comes first. NAAC-6187-EN Page 1 of 6

Specifications General Technical Data for Valve assembly Vibration Limits 5G @ 10-55 Hz * Valve body (2) Max. @ Evac Temp 250psi @ 250 F 500psi @ 150 F 700psi @ 50 F Materials & Requirements if Customer-supplied Hoses (1) & (3) Valve body(2) Check Valve (4) (1) Vacuum rated Rated for 250 F (3) Rated for refill pump s pressure Body: 6061 Alum. Valve: Polypropylene Spring & support, Coupler: Steel Steel,zinc-plated 1 psi opening.02 ml/m leakage Rated for 500 psi * For installations beyond the vibration limits, contact Industries for assistance. Quick Coupler (B) Overall Length (A) Evac Flow w/ 70 F* 15W-40 Evac Flow w/ 200 F 15W-40 Weight Coupling Force (lbs) Recommended Hose (L x ID) ½ (ISO 12.5) Flat/Flush Face 7.5 inches 5.5 gpm 10 gpm 2.6 lbs 35 lbs 3 x 0.75 1 (ISO 25) Flat/Flush Face 8.0 inches 11 gpm 25 gpm 4.1 lbs 65 lbs 3 x 1.0 Pump used to evacuate/refill oil can be a limiting factor only if its capacity is lower than the QuickFit flow capacity as mentioned above. Any pump that is above QuickFit flow capacity will not create any restrictions. *Flow listed is with 1 ID, 3 long suction line to sump. Longer or smaller line will reduce flow. Flow will be higher & drain time reduced w/ warmer, thinner oil. Engine makers suggest running engine to warm & mix oil before drain. 4 3 Existing systems on the engine 2 1 Typical QuickFit Valve Installation (to filter-head & sump) Expanded QuickFit Valve Assembly NAAC-6187-EN Page 2 of 6

Cummins Part Numbers matched to the Engine Platforms: Engine Platform 4BT3.3 QSB5 QSB7 QSL9 QSM11 QSX15 QSK19 QSK23 QST30 QSK50 QSK60 QSK60 MCRS QSK78 Cummins Power Generation Part Number A054E036 A054E034 A054E033 A054E035 A054E005 A054E004 A054E128 A054E127 A054E308 A054E121 A054E122 A054E122 A054E123 Required Tools to perform service with QuickFit : Required Tools: Lube Truck/Shop Conversion Service Tools with 1/2 inch port size (Default for all QuickFit Kits) Tool Image Description Part No. Service Shop / Convert existing service shop or truck for machines A054S255 Lube Truck: installed with QuickFit QuickFit conversion kit OR Lube Truck/Shop Conversion Service Tools with 1 inch port size (Specific Order) Tool Image Description Part No. Service Shop / Convert existing service shop or truck for machines A054S257 Lube Truck: installed with QuickFit QuickFit conversion kit Notes: By default, all the QuickFit kits come with 1/2 inch port size. The conversion kit and purge tool with 1/2 inch port size should be the default selection for a standard QuickFit Kit. The conversion kit and purge tool with 1 inch port size are only for specific orders. These would also require a special Quick Disconnect fitting in the QuickFit kit. The fittings with 1 inch port size would be useful where the flow rate is expected to be around 20-25 gallons. Spec Sheet can be referenced for more information on Flow rates. NAAC-6187-EN Page 3 of 6

Service Parts available for QuickFit : Service Parts Part Image Description Part Number QuickFit Valve Body Small Male Flush Face Quick Disconnect, #8 NPT (1/2 inch) Includes QuickFit Valve with internal parts and Flat Face Quick Disconnect Used to couple to female 103991. Used on end of hoses whips 1/2" NPT (Use to adopt existing service system) A054S490 A054U229 OEM Small Female Flush Face Quick Disconnect #8 NPT (1/2 inch) Used to couple to male 103990. Used on hoses evac bracket, other tools 1/2" NPT (Can use to adopt existing service system) A054U230 Large Female Flush Face Quick Disconnect #16 NPT (1 inch) Used to couple to male 103488. Used on hoses evac bracket, other tools 1" NPT (Can use to adopt existing service system) A054U433 Large Male Flush Face Quick Disconnect #16 NPT (1 inch) Used to couple to female 103487. Used on end of hoses whips 1" NPT (Can use to adopt existing service system) A054U434 Standard Oil filter Purge Tool (1/2 inch) Used to purge oil filter with compressed air (65 psi, 446 kpa min.) (Can be used to adopt existing truck or shop) A054U439 Large Oil Filter Purge Tool (1 inch) Used to purge oil filter with compressed air (65 psi, 446 kpa min.) (Can be used to adopt existing service system) A054U444 NAAC-6187-EN Page 4 of 6

Suggested Tools for Oil Evacuation/: QuickFit Evacuation/ Tools Tool Image Description Part No. Function OEM Handheld pump used to A054V098 Evacuation evacuate oil on machines having QuickFit plumbing. Suitable for Engine displacement of 15L and below. 2.0/2.5 gpm Flow w 75 o F Oil 2.2/4.5 gpm Flow w 150 o oil Continuous duty (<16A) Self-Contained Evacuation Tool (SCET): Dual 12/24 VDC with dedicated hose ends for Evac (Extension harness & hose available as required) Self-Contained Tool (SCReT): Dual 12/24 VDC (Extension harness & hose available as required) Handheld pump used to refill oil on machines having QuickFit plumbing. Suitable for Engine displacement of 15L and below. 3.5 gpm Flow w 95 o F oil Continuous duty (<16A) A054V099 AC Pump 115 V AC 60 HZ 3/4 HP 7.6 GPM Max Flow rate 150 psi Max pressure Recommended for Shop service A054V100 Evacuation/ DC Pump AC Pump 12V/24V DC Flow at 70 o F 8 gpm/16 gpm 120 psi Max pressure Max Run time cycle 10 minutes at recommended temperature of 70 o F 208-240/ 415-480 V AC 5.0 HP (3 phase) 35 GPM Max Flow 100 psi Max Recommended for Shop service A054V102 A042P998/ A054V103 Evacuation/ Evacuation NAAC-6187-EN Page 5 of 6

DC Pump Tool Image Description Part No. Function OEM 12/24 V DC 15/30 gpm Max Flow 100 psi Max pressure Recommended for Field service Recommended oil temperature min 70 o F One time run restriction - 15 minutes A054W130 Evacuation Air Piston Pump (Small) Air Piston Pump (Large) 450 psi/ 750 psi 3:1 / 5:1 pump ratio 2.6-4.1 / 2.0-4.8 gpm Recommended for engine displacement up to 15 litres 540 psi Max 3:1 pump ratio 13.4 gpm A054X047 A054X048 Air-operated Diaphragm pump 1" AODD size 20-67 SCFM Max Air Draw 125 psi Max pressure 20-30 gpm depending on oil temperature A054Y319 Evacuation/ AC Pump (For Preset Meter) 115 V AC 1.0/2.0 HP 2.6/3.7 gpm Max Flow 550/650 psi Max A054X050/ A054X051 NAAC-6187-EN Page 6 of 6