Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Similar documents
TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

MODEL 1100 TURBINE FLOW METER

Model 1100 Turbine Flow Meter

MODEL 1100 TURBINE METER REPAIR KITS

Turbine Flow Meter Series Turbine Meter USER MANUAL

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)

MODEL 200 MULTI-JET FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER

Model 1100 Turbine Flow Meter

MODEL 200 MULTI-JET FLOW METER

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Model 1100 Turbine Flow Meter Repair Kits

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

Liquid Turbine Flowmeter

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual

EZ-IN Series Turbine Flowmeter

C-LB45-A FUEL METER ASSEMBLY INSTALLATION & OPERATION MANUAL

Turbine Flow Meter. User Manual. Top Load 1 in. and 2 in. Meters. TRB-UM EN-01 (September 2018)

COMPANY. Liquid Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:FLOWLIQUIDMETERMAN082516

TX 115/215 Hot-tap Insertion Turbine Instructions

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Industrial Turbo Meters, Sizes 2" through 6"

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

TX101/201 Insertion Turbine Instructions

TX115/215 Hot-tap Insertion Turbine Instructions

INSTALLATION AND OPERATION

TX101/201 Insertion Turbine Instructions

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

TABLE OF CONTENTS GENERAL INFORMATION

NJK Precision Product NJK-02 Sensor Installation Guide

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

A1 Commercial Grade Meters

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

FIXED DEPTH INSERTION METER INSTRUCTIONS

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

COMPANY. Flow Rate Alarms Installation, Operating & Maintenance Manual

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

Positive Displacement Flowmeters GM020 series instruction manual

GPM Hydraulic Flow Meter User Manual

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

WARCO CHEMAG SERIES GH FILTERS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Liquid Turbine Flow Meter OwnerÊs Manual

Liquid Turbine Flowmeters

Flow Sensors & Instruments

G2 Industrial Grade Meters

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Analog Hydraulic Testers

FLOW MEASUREMENT TECHNOLOGY FOR POWER AND ENERGY

Positive Displacement Flowmeters GM007 series instruction manual

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

Flow Meters. Installation, Operation & Maintenance Manual.

BI-DIRECTIONAL INSERTION METER

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

CIRCLE SEAL CONTROLS

POSITIVE DISPLACEMENT FLOWMETERS

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

Hoffer Engineering Guide for Liquids

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

7000 Series Liquid Turbine Meters

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Positive Displacement Flowmeters GM020 series instruction manual

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

SERVICE KITS REBUILD KIT DESCRIPTION CHART MODEL DESCRIPTION CHART SPECIFICATIONS X X 1 - B X - X X X - B

flow measurement solutions RIM10 series rotor insertion flowmeters

Series 44 Installation Instructions

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Liquid Turbine Flowmeters

M SERIES Multi-Jet Cold Water Meter

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Liquid Turbine Flow Meters

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

To ensure proper installation, digital pictures with contact information to before startup.

Transcription:

COMPANY Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:SANITARYMAN16

Mechanical Specifications Measuring Accuracy ± 1.0% of reading or better Repeatability ± 0.1% Flow Measuring Range 0.6 to 400 GPM (gal/min) Turn Down Ratio 10:1 Maximum Operating Pressure ** Working pressure up to 1,000 psi Temperature Range * Fluid temperature up to 300 F Electrical Connection NEMA 6 Connector Port Connection Tri-clamp *Sensor & seal dependent. ** Depends on connection size & clamp. Note:.COP (Clean-Out-of-Place) Materials of Construction Body & Rotor Support 316L Stainless Steel Rotor Nickel Plated Stainless Steel Bearings Nickel Bindery Tungsten Carbide Electronics Model Sensor Type Temp ( F) RT-10R Battery-Powered Monitor 0 to 140 RT-30SD 15-24 VDC Powered Monitor 0 to 140 MAG-INVA Amplified Pulse Output 0 to 140 MG-300 Non-Amplified (external amplifer needed) 0 to 300 MG-450 Non-Amplified (external amplifer needed) 0 to 450 *Contact factory for additional sensor options. 2

Meter Specifications Part Number Range (gal/min) K-Factor * (Pulses/ gal) Meter Size Clamp Size TA3-75-375 0.6 to 3 20,000 3/8 3/4 1 TA3-75-500 0.75 to 7.5 13,000 1/2 3/4 1 TA3-75-750 2 to 15 2,750 1/2 3/4 1 Weight (lbs) TA3-150-500 0.75 to 7.5 13,000 1/2 1-1/2 3 TA3-150-750 2 to 15 2,750 1/2 1-1/2 3 TA3-150-875 3 to 30 2,600 7/8 1-1/2 3 TA3-150-100 5 to 50 870 1 1-1/2 3 TA3-150-150 15 to 180 330 1-1/2 1-1/2 5.5 TA3-250-200 40 to 400 50 2 2-1/2 8.5 * K-Factors given are averaged. A calibration sheet accompanies every meter sold. 3

Introduction The TA-3 Sanitary turbine flow meter is designed with wear resistant moving parts to provide trouble-free operation and long service life. The durable 316L stainless steel construction provides a cost efficient flow measurement system that offers excellent accuracy and repeatability. The TA-3 Sanitary turbine meter repair kit is designed for easy field service of a damaged flow meter, rather than replacing the entire flow meter. See Repair Kits on page 8 for information. Theory of Operation Fluid entering the meter passes through the inlet flow straightener which reduces its turbulent flow pattern and improves the fluid s velocity profile. Fluid then passes through the turbine, causing the rotor to rotate at a speed proportional to the fluid velocity. As each turbine blade passes through the magnetic field, the blade generates an AC voltage pulse in the pickup coil at the base of the magnetic pickup (see Figure 1). These pulses produce an output frequency proportional to the volumetric flow through the meter. The output frequency represents flow rate and/or totalization of fluid passing through the turbine flow meter. Output Signal Magnetic Pickup Rotor Figure 1. Theory of Operation 4

Installation WARNING: The meter should not be subjected to temperatures above 300 F (149 C), below -150 F (-101 C) or the freezing point of the metered liquid. High temperatures will damage the magnetic pickup, while lower temperatures will limit the rotation of the rotor. WARNING: Incompatible fluids could deteriorte internal parts and cause the meter to read inaccurately. Plumbing Install the flow meter with the flow arrow, which is etched on the exterior of the meter body, pointing in the direction of fluid flow. Install the meter horizontally with the magnetic pickup facing upward. The liquid being measured must be free of any large particles that may obstruct spinning of the rotor. If particles are present, install a mesh strainer. If small particles are present in the fluid, install a strainer upstream of the meter. See Table 1 for filtration recommendations. Table 1 Bore Size Ferrule Size Strainer Size Clearance 3/8 in. (9.53 mm) 0.984 in. (24.99 mm) 60 60 0.0092 in. (0.23 mm) 1/2 in. (12.7 mm) 0.984 in. (24.99 mm) 60 60 0.0092 in. (0.23 mm) 3/4 in. (19.05 mm) 0.984 in. (24.99 mm) 60 60 0.0092 in. (0.23 mm) 1/2 in. (12.7 mm) 1.984 in. (50.39 mm) 60 60 0.0092 in. (0.23 mm) 3/4 in. (19.05 mm) 1.984 in. (50.39 mm) 60 60 0.0092 in. (0.23 mm) 7 8 in. (22.23 mm) 1.984 in. (50.39 mm) 60 60 0.0092 in. (0.23 mm) 1 in. (25.4 mm) 1.984 in. (50.39 mm) 60 60 0.0092 in. (0.23 mm) 1-1/2 in. (38.1 mm) 1.984 in. (50.39 mm) 20 20 0.034 in. (0.86 mm) 2 in. (50.8 mm) 3.047 in. (77.39 mm) 10 10 0.065 in. (16.51 mm) 5

4 1647 4 1647 Severe pulsation and mechanical vibration affects accuracy and shortens the life of the meter. The preferred plumbing setup is one containing a bypass line that allows meter inspection and repair without interrupting flow. See Figure 2. If a bypass line is not utilized, it is important that all control valves be located downstream of the flow meter. See Figure 3. This is true with any restriction in the flow line that may cause the liquid to flash. If necessary, air eliminators should be installed to ensure that the meter is not incorrectly measuring entrained air or gas. Figure 2: Installation with bypass line Isolation Valve TA-3 Sanitary Turbine Flow Meter Isolation Valve 10 Pipe Diameters Minimum 5 Pipe Diameters Minimum Bypass Line It is recommended that a minimum length, equal to ten (10) pipe diameters of straight pipe, be installed on the upstream side and five (5) diameters on the downstream side of the flow meter. Otherwise, meter accuracy may be affected. Piping should be the same size as the meter bore or threaded port size. Figure 3: Installation without a bypass line TA-3 Sanitary Turbine Flow Meter Isolation Valve 10 Pipe Diameters Minimum 5 Pipe Diameters Minimum 6

Do not locate the flow meter or connection cable close to electric motors, transformers, sparking devices, high voltage lines, or place connecting cable in conduit with wires furnishing power for such devices. These devices can induce false signals in the flow meter coil or cable causing the meter to read inaccurately. WARNING: Damage can be caused by striking an emply meter with a high velocity flow stream. If problems arise with the flow meter and monitor, consult the Troubleshooting Guide on page 13. If further problems arise, consult the factory. If the internal components of the turbine flow meter are damaged, order a turbine meter repair kit. See Repair Kits on page 10. Operational Startup The following steps should be followed when installing and starting the meter. WARNING: Make sure that fluid flow has been shut off and pressure in the line released before attempting to install the meter in an existing system. 1. After meter installation, keep the isolation valves closed and the bypass valve open. Flow liquid through the bypass valve for sufficient time to eliminate any air or gas in the flow line. 2. Open upstream isolating valve slowly to eliminate hydraulic shock while charging the meter with the liquid. Open the valve to full open. CAUTION: High velocity air or gas may damage the internal components of the meter. 3. Open downstream isolating valve to permit meter to operate. 4. Close the bypass valve to a full closed position. 5. Adjust the downstream valve to provide the required flow rate through the meter. NOTE: The downstream valve may be used as a control valve. 7

Dimensions and Drawings Figure 5: Dimensions C A B Table 4: Dimensions Part Number A B C TA3-75-375 3.00 in. (76 mm) 1.5 in. (38 mm) 1 in. (25 mm) TA3-75-500 3.00 in. (76 mm) 1.5 in. (38 mm) 1 in. (25 mm) TA3-75-750 3.00 in. (76 mm) 1.5 in. (38 mm) 1 in. (25 mm) TA3-150-500 4 in. (101 mm) 2.0 in. (50 mm) 2.0 in. (50 mm) TA3-150-750 4 in. (101 mm) 2.0 in. (50 mm) 2.0 in. (50 mm) TA3-150-875 4 in. (101 mm) 2.0 in. (50 mm) 2.0 in. (50 mm) TA3-150-100 4 in. (101 mm) 2.0 in. (50 mm) 2.0 in. (50 mm) TA3-150-150 6.25 in. (158 mm) 2.3 in. (59 mm) 2.0 in. (50 mm) TA3-250-200 6.5 in. (161 mm) 2.3 in. (59 mm) 3 in. (76 mm) 8

Figure 6: TA-3 Sanitary Meters Cross Sections Rotor Assembly Sleeve Bearing Thrust Ball (Removable) Retaining Ring Magnetic Pickup Jam Nut Meter Body Rotor Support Manufacturer s Label and 3-A Symbol Meter Repair and Cleaning Repair Kits Each TA-3 turbine repair kit is factory-calibrated for accuracy throughout the entire flow range. Each kit is complete and includes a new K factor, which is the calibrated number of pulses generated by each gallon of liquid. This K factor will be used to recalibrate the monitor or other electronics to provide accurate output data. Service Procedures Turbine Repair Kits Part Numbers Table 5: TA-3 Sanitary Meters Repair Kits Bore Size Ferrule Size Repair Kit Fits Meter Part Number Repair Kit Part Number 3/8 in. (9.53 mm) 1 in. (25 mm) TA3-75-375 TA3-375 1/2 in. (12.7 mm) 1 in. (25 mm) TA3-75-500 TA3-500 3/4 in. (19.05 mm) 1 in. (25 mm) TA3-75-750 TA3-750 1/2 in. (12.7 mm) 2 in. (50 mm) TA3-150-500 TA3-500 3/4 in. (19.05 mm) 2 in. (50 mm) TA3-150-750 TA3-750 7/8 in. (22.23 mm) 2 in. (50 mm) TA3-150-875 TA3-875 1 in. (25.4 mm) 2 in. (50 mm) TA3-150-100 TA3-100 1-1/2 in. (38.1 mm) 2 in. (50 mm) TA3-150-150 TA3-150 2 in. (50.8 mm) 3 in. (78 mm) TA3-250-200 TA3-200 9

3-A Turbine Disassembly and Cleaning Procedure WARNING: High-pressure leaks are dangerous and cause personal injury. Make sure that fluid flow had been shut off and pressure in the line released before attempting to remove the meter. NOTE: Refer to Figure 7 for relative positions of repair kit components. 1. Remove the magnetic pickup from the meter body to avoid damage during procedure. 2. Remove the retaining ring from one end of the meter. 3. Keeping the meter upright (pickup port at the top), remove the rotor support from the body, taking care not to rotate it in the process. If the rotor support is jammed in the body, use a pair of pliers or vice grips to break it free. 4. Hold the rotor support over a suitable container and rotate it through 180. The thrust ball will drop out. Take care not to lose the ball. 5. Remove the rotor assembly. 6. Remove the second retaining ring from the opposite side of the meter. 7. Repeat steps 3 and 4 for the remaining rotor support. 8. Identify parts and flow direction to match with original meter body. 9. Clean and/or sanitize parts to meet appropriate sanitary standards. 10

Figure 7: TA-3 Sanitary Turbine Exploded View Meter Body A Jam Nut Magnetic Pickup Sleeve Bearing Rotor Support A SECTION A-A Retaining Ring Thrust Ball Rotor Assembly Remove Rotor Release Jam Nut and Remove Magnetic Pickup Remove Rotor Supports Do Not Rotate During Extraction Remove Retaining Rings Thrust Ball Extraction Hole Rotate Rotor Support Through 180 To Extract Thrust Ball Clean and Inspect Component Parts Per 3-A Sanitary Standards; Reverse Dismantling Procedure to Reassemble 3-A Turbine Installation NOTE: This procedure applies to installation of replacement turbine repair kits and re-installation of cleaned or sanitized turbine. IMPORTANT: Before reassembly, note there are weep holes on each rotor support. These weep holes must be facing down toward the bottom of the meter body when installed. The meter must be reassembled with the arrowheads on the rotor pointed in the direction of fluid flow. The magnetic pickup side of the body signifies the up position. This is the position that the repair kit was calibrated, and this is the position to be used to ensure meter accuracy. Due to the polished surfaces, there are no arrows on the rotor support to indicate which rotor support is to be placed 11

upstream or downstream. Please install the repair kit as it was received in the box, using the arrow on the rotor to determine the placement of the rotor support. 1. If required by process procedures, the meter should be cleaned prior to installation into the piping system. 2. Drop a thrust ball into a rotor support through the hole provided in the side. Insert rotor support into the meter body. Keep the thrust bearing hole pointed upwards to keep the ball in place. 3. Secure a retaining ring in the groove provided. Be sure that the retaining ring is completely installed in the groove. 4. Drop a thrust ball into second rotor support through the hole provided in the side. Locate the rotor in the support sleeve bearing. Insert rotor support and rotor into the meter body and the first support sleeve bearing. Keep the thrust bearing hole pointed upwards to keep the ball in place. 5. Secure the second retaining ring in the groove provided. Be sure that the retaining ring is completely installed in the groove. WARNING: Excess air pressure may damage the rotor and bearings by over-spin. 6. Check the meter by blowing air through the assembly. If the rotor does not turn freely, the meter should be disassembled and checked for anything that would obstruct movement of the rotor. 7. Install the magnetic pickup. NOTE: After installing the new repair kit, the electronics will need re-calibration. Refer to the electronics installation and operation manual. If there are any questions on re-calibration, contact AW-Lake Company at 1.800.850.6110 or contact the manufacturer of the associated electronics. 12

Troubleshooting Guide 13

14

15

COMPANY 262.884.9800 www.aw-lake.com 2440 W. Corporate Preserve Dr. #600 Oak Creek, WI 53154 2016 AW-Lake Company. All rights reserved. Doc ID:SANITARYMAN16