ConstantColor CMH PAR 20 & PAR 30 Ceramic Metal Halide Lamps 20W, 35W and 70W

Similar documents
ConstantColor CMH PAR 20 & PAR 30 Ceramic Metal Halide Lamps 20W, 35W and 70W

ConstantColor CMH MR16

ConstantColor CMH TD. GE Lighting DATA SHEET. Double Ended Ceramic Metal Halide Lamps 35W, 70W and 150W. Product information.

ConstantColor CMH Supermini

ConstantColor CMH. GE Lighting DATA SHEE T. Ceramic Metal Halide Lamps Single Ended G12 Product Information. Lamp technology. Single ended format

GE ConstantColor CMH TM CMH SuperMini 20W & 35W

ConstantColor CMH Open Rated

ConstantColor CMH Supermini

ConstantColor CMH High Wattages

ConstantColor CMH Tubular Clear

ConstantColor CMH G8.5 and G12 Ultra

ConstantColor CMH MR16

ConstantColor CMH MR16 Ultra

ConstantColor CMH Mini G8.5

ConstantColor CMH Mini G8.5

ConstantColor CMH Supermini Ultra

GE Lighting. Single Ended G8.5 Ceramic Metal Halide Lamps Product Information for Original Equipment Manufacturers

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

Multi-Vapor Metal Halide Lamps

Arcstream Double Ended

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

GE Lighting DATA SHEET. Product information. Features. Applications

Lucalox Standard. GE Lighting. Product information. Applications areas

Energy efficient low voltage dichroic mirror halogen reflector lamps

T5 Watt-Miser Linear Fluorescent lamps

HaloGLS, HaloCandle and HaloSpherical lamps

Lamps CERAMIC METAL HALIDE

Biax D and D/E. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W. GE Lighting DATA SHEET. Product information.

GE ConstantColor CMH StreetWise

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

Spiral T2 10,000 & 8,000 hours

Biax D and D/E. GE Lighting DATA SHEE T. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W

Samsung LED lighting: MR16. Samsung LED lighting: PAR. Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures.

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Infusion Module Gen2 M1000, M1500, M2000 and M3000 Series

Infusion Module M4500 Series High lumen LED lighting

Retrofit without Compromise

2D Watt-Miser. GE Lighting DATA SHEET. Applications areas. Features. Lamp technology. Application areas

Perfect sparkle, unrivalled efficiency

SHP-S/SHP-TS Super SA SHP-TS 70W/CL E27 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

Product Description. MASTER HPI-T Plus. Quartz metal halide lamps with clear outer bulb

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

Infusion Module NPM Series

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

Product Description. MASTER HPI Plus. Quartz metal halide lamps with opalized outer bulb

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

Simply irresistable. Superior light quality from start to finish

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

ELLIPTICAL REFLECTORS

18 Watt LED Spotlight with Magnetic Base - Articulating Light Head Tilting - IP65-25' Cord w/ Plug

2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

HIGH PRESSURE SODIUM. EYE Lighting Volume 6 Catalogue

MasterColor CDM-R111 70W/830 10D 1CT

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

HCI-T 35 W/830 WDL PB

LED modules LED linear / area

Infusion Module NPM Series

Bridgelux Gen 7 Vero 10 Array Series. Product Data Sheet DS90

Induction lamps and control gear

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Beautiful sparkle, reliable life

Smart Lamp Operating System

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

LED light engine / OLED LED linear / area

HCI-T 150 W/830 WDL PB

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

Solar Powered 10 Watt LED Light - 12 Hour Run Time - Day/Night Photocell or Motion Sensor

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

LED light engine / OLED LED compact

Bridgelux Vero. Product Data Sheet DS120. SE 10 Array

Product datasheets 11

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

HCI-TS 150 W/830 WDL PB

Constant wattage for high intensity discharge (HID) lamps

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt

Beautiful sparkle, reliable life

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

STATIC DAYLIGHT PAR 575 VF

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LED Floodlights. Product Features. Applications

Transcription:

GE Lighting ConstantColor CMH PAR 2 & PAR 3 Ceramic Metal Halide s 2W, 35W and 7W DATA SHEET Product information ConstantColor CMH lamps combine the HPS technology (providing stability, efficiency & uniformity) and the Metal Halide Technology (bright white quality light) to produce highly efficient light sources with good colour rendering and consistent colour performance through life. This is achieved by using the ceramic arc tube material from the Lucalox TM lamp, which minimises the chemical changes inside the lamp through life. When combined with the halide doses used in Arcstream TM Metal Halide lamps then the quality and stability of the dose maintains the colour consistency. Hence the name ConstantColor CMH. Metal halide lamps, traditionally made with quartz arc tubes, are prone to colour shift through life and lamp-tolamp colour variation. Some of the dose, e.g. sodium, (an important component of metal halide lamps), can migrate through quartz to cause colour shift and loss of light through life. The ceramic arc tube resists this material loss, can be manufactured to tighter tolerances and withstands a higher temperature to provide a more constant colour. Application areas Retail Offices Architectural floodlighting Amenity areas Hotels Features Excellent colour consistency High efficient compact source Unique 3-part ceramic arc-tube design provides higher durability resulting in better reliability Up to 13, hours Life High 8+ to 9+ colour rendering index (CRI) UV control 2W PAR 2&3 lamps operate on electronic ballast (thermal protection needed) 35W PAR 2&3 lamps operate on standard or electronic ballast (thermal protection needed) 7W PAR3 lamps operate on standard or electronic ballast (no thermal protection needed)

Specification summary Wattage Volts [V] Dimensions Cap Product Description Product Code Candela [cd] Beam Angle [ ] Colour Operating Position Average Rated Life Vertical & Horizontal [h] CMH PAR 2 2 95 E27 CMH2/PAR2/UVC/83/E27/SP1 2678 13, 1 83 U 12, 15 2 95 E27 CMH2/PAR2/UVC/83/E27/FL25 2681 3,75 25 83 U 12, 15 35 9 E27 CMH35/PAR2/UVC/83/E27/SP1 2168 22, 1 83 U 1, 15 35 9 E27 CMH35/PAR2/UVC/83/E27/FL25 21685 7,5 25 83 U 1, 15 35 9 E27 CMH35/PAR2/UVC/92/E27/SP1 89 19,5 1 92 U 1, 15 35 9 E27 CMH35/PAR2/UVC/92/E27/FL25 919 6,95 25 92 U 1, 15 CMH PAR 3 2 95 E27 CMH2/PAR3/UVC/83/E27/SP1 2697 19,8 1 83 U 12, 6 2 95 E27 CMH2/PAR3/UVC/83/E27/FL25 26518,9 25 83 U 12, 6 35 9 E27 CMH35/PAR3/UVC/83/E27/SP1 21689 39,6 1 83 U 1, 6 35 9 E27 CMH35/PAR3/UVC/83/E27/FL25 2169 11, 25 83 U 1, 6 35 9 E27 CMH35/PAR3/UVC/92/E27/SP1 939 36,7 1 92 U 1, 6 35 9 E27 CMH35/PAR3/UVC/92/E27/FL25 92 1,2 25 92 U 1, 6 7 9 E27 CMH7/PAR3/UVC/83/E27/SP15 21683 2,8 15 83 U 13, 6 7 9 E27 CMH7/PAR3/UVC/83/E27/FL 21682 1, 83 U 13, 6 7 9 E27 CMH7/PAR3/UVC/92/E27/SP15 762 33,5 15 92 U 1, 6 7 9 E27 CMH7/PAR3/UVC/92/E27/FL 7619 9, 92 U 1, 6 CMH PAR 2 A Pack Quantity B Nominal Length [mm] A Maximum Length [mm] B Maximum Diameter [mm] Bulb Glass Operating Position Fixture Rating 82 92 6 Heat Resistant Universal Open CMH PAR 3 A B Nominal Length [mm] A Maximum Length [mm] B Maximum Diameter [mm] Bulb Glass Operating Position Fixture Rating 119 12 95.5 Heat Resistant Universal Open Spectral power distribution CMH 2W 3K spectral distribution CMH 35W 3K spectral distribution 39 1 3 5 7 9 51 53 55 57 59 61 63 65 67 69 71 73 75 39 1 3 5 7 9 51 53 55 57 59 61 63 65 67 69 71 73 75 Relative Intensity Relative Intensity 2 Wavelength [nm] Wavelength [nm]

CMH 35W 2K spectral distribution CMH 7W 3K spectral distribution 39 1 3 5 7 9 51 53 55 57 59 61 63 65 67 69 71 73 75 39 1 3 5 7 9 51 53 55 57 59 61 63 65 67 69 71 73 75 Relative Intensity Relative Intensity Wavelength [nm] Wavelength [nm] CMH 7W 2K spectral distribution Current Lumens CBCP CCT Chromaticity Coordinates CRI X Y 3K 2W.211 1 13 3.36. 8+ Relative Intensity.211 1 375 3.36. 8+.211 12 198 3.36. 8+.211 12 9 3.36. 8+ 3K 35W.53 21 22 3.35.1 8+.53 21 75 3.35.1 8+.53 2 396 3.31.6 8+.53 2 11 3.31.6 8+ 2K 35W.53 195 195 2.37.363 9+.53 195 695 2.37.363 9+.53 2225 367 2.37.363 89 39 1 3 5 7 9 51 53 55 57 59 61 63 Wavelength [nm] 65 67 69 71 73 75.53 2225 12 2.37.363 89 3K 7W.98 7 3 3.36.1 8+.98 7 1 3.36.1 8+ 2K 7W.96 3 9 2.37.373 89.96 3 335 2.37.373 89 Distribution of luminous intensity 2W PAR2 3K SP1 2W PAR2 3K FL25 8 1 15 12 2 16 25 2 3 cd/klm cd/klm 3

2W PAR3 3K SP1 2W PAR3 3K FL25 6 2 8 1 3 12 cd/klm cd/klm 35W PAR2 3K SP1 35W PAR2 3K FL25 1 15 6 2 8 25 1 3 3 15 15 3 cd/klm 3 15 15 3 cd/klm 35W PAR3 3K SP1 35W PAR3 3K FL25 2 8 3 12 5 3 15 15 3 3 15 15 3

35W PAR2 2K SP1 35W PAR2 2K FL25 1 15 6 2 8 25 1 3 cd/klm cd/klm 35W PAR3 2K SP1 35W PAR3 2K FL25 2 8 3 12 5 3 15 15 3 3 15 15 3 7W PAR3 3K SP15 7W PAR3 3K FL 8 12 6 16 8 2 1 2 3 15 15 3 3 15 15 3 5

7W PAR3 2K SP15 7W PAR3 2K FL 1 25 2 5 3 75 1 5 125 6 15 7 175 8 3 15 15 3 2 3 15 15 3 Distribution of luminous intensity 2W PAR2 3K SP1 2W PAR2 3K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 51981.5 meter.87 1995.5 meter.222 12995.175 379.3 5776.262 1666.665 329.35 937.887 279 2..37 6 2. 1.18 1.525 17 1.33 161.612 36 1.552 812.7 23 1.77 62.787 185 1.995 52.875 15 2W PAR3 3K SP1.875 2W PAR3 3K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 79171.5 meter.87 19593.5 meter.222 19793.175 898.3 8797.262 2177.665 98.35 1225.887 3167 2..37 78 2. 1.18 2199.525 5 1.33 1616.612 1.552 1237.7 36 1.77 977.787 22 1.995 792.875 196 6.875

35W PAR2 3K SP1 35W PAR2 3K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 87968.5 meter.87 29989.5 meter.222 21992.175 797.3 977.262 3332.665 598.35 187.887 3519 2..37 12 2. 1.18 2.525 833 1.33 1795.612 612 1.552 1375.7 69 1.77 186.787 37 1.995 88.875 3.875 35W PAR3 3K SP1 35W PAR3 3K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 15832.5 meter.87 398.5 meter.222 39586.175 1996.3 1759.262 887.665 9896.35 279.887 633 2..37 1759 2. 1.18 398.525 1222 1.33 3231.612 898 1.552 27.7 687 1.77 1955.787 53 1.995 1583.875.875 35W PAR2 2K SP1 35W PAR2 2K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 8156.5 meter.87 278.5 meter.222 2387.175 695.3 961.262 389.665 597.35 1737.887 3262 2..37 1112 2. 1.18 2265.525 772 1.33 166.612 567 1.552 127.7 3 1.77 17.787 33 1.995 815.875 278.875 7

35W PAR3 2K SP1 35W PAR3 2K FL25 to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 16783.5 meter.87 773.5 meter.222 36696.175 1193.3 1639.262 53.665 917.35 258.887 5871 2..37 1631 2. 1.18 77.525 1133 1.33 2996.612 832 1.552 2293.7 637 1.77 1812.787 53 1.995 168.875 8.875 7W PAR3 3K SP15 7W PAR3 3K FL to Surface Angle: Nominal Beam Angle: 1 from Diameter [m] to Surface Angle: Nominal Beam Angle: 25 from Diameter [m] 171938.5 meter.87 39985.5 meter.222 298.175 9996.3 191.262 3.665 176.35 299.887 6878 2..37 1599 2. 1.18 776.525 1111 1.33 359.612 816 1.552 2687.7 625 1.77 2123.787 9 1.995 1719.875.875 7W PAR3 2K SP15 7W PAR3 2K FL to Surface Angle: Nominal Beam Angle: 13.5 from Diameter [m] to Surface Angle: Nominal Beam Angle: 28.7 from Diameter [m] 19938.5 meter.118 3883.5 meter.256 378.237 978.512 1666.355 31.768 9371.7 227 1.2 5998 2..592 1553 2. 1.279 165.711 179 1.535 36.829 792 1.791 233.97 67 2.7 1851 1.66 79 2.33 199 1.18 388 2.559 8 1.18 2.559

life The graphs show the mortality curve of statistically representative batches of lamps operated under controlled conditions of 11 hours per start. The declared lamp life is the median life, which is when 5% of the lamps from a large sample batch would have failed. life in service will be affected by a number of parameters, such as supply voltage variation, switching cycle, operating position, mechanical vibration, luminaire design and control gear. The information is intended to be a practical guide for comparison with other lamp types. The determination of lamp replacement schedules will depend upon the acceptable reduction in illuminance and the relative costs of spot and group replacement. Note: The representative curves are taken in Vertical Base Up position. Life performance can greatly increase in Horizontal Burning position survival CMH 2W 3K PAR2 and PAR3 survival CMH 35W 3K PAR2 and PAR3 1% 1% 9% 9% % lamp survival 8% 7% 6% 5% % 3% % lamp survival 8% 7% 6% 5% % 3% 2% 2% 1% 1% % 2 6 8 1 12 % 2 6 8 1 % lamp survival 1% survival CMH 7W 3K PAR3 9% 8% 7% 6% 5% % 3% 2% 1% % 2 6 8 1 12 % lamp survival 1% survival CMH 35W 2K PAR2 and PAR3* 9% 8% 7% 6% 5% % 3% 2% 1% % 2 6 8 1 1% survival CMH 7W 2K PAR3 * Life rating on conventional ballast. Testing continues to validate 12 Hours life. 9% 8% % lamp survival 7% 6% 5% % 3% 2% 1% % 2 6 8 1 9

Lumen maintenance Lumen maintenance graph shows how the luminous output decreases throughout life. All metal halide lamps experience a reduction in light output and a very slight increase in power consumption through life. Consequently there is an economic life when the efficacy of the lamp falls to a level at which is better to replace the lamp and restore the illumination. Where a number of lamps are used within the same area it may be well worth considering a group lamp replacement programme to ensure uniform output from all the lamps. Curves are representing 11 hours per start cycle, less frequent starting will improve lumen maintenance. Note: The representative curves are taken in Vertical Base Up position. 1 CMH PAR2 2W 3K 1 CMH PAR3 2W 3K 8 8 % of Initial lumens 6 2 % of Initial lumens 6 2 2 6 8 1 12 2 6 8 1 12 1 CMH PAR2 35W 3K 1 CMH PAR3 35W 3K 8 8 % of Initial lumens 6 2 % of Initial lumens 6 2 2 6 8 1 2 6 8 1 1 CMH PAR2 35W 2K 1 CMH PAR3 35W 2K 8 8 % of Initial lumens 6 2 % of Initial lumens 6 2 2 6 8 1 2 6 8 1 1 CMH PAR3 7W 3K 1 CMH PAR3 7W 2K % of Initial lumens 8 6 2 % of Initial lumens 8 6 2 2 6 8 1 12 2 6 8 1 1

Warm-up characteristics During the warm-up period immediately after starting, lamp temperature increases rapidly and mercury and the metal halides evaporate within the arc-tube. The lamp current and voltage will stabilise in less than 3 minutes. During this period the light output will increase from zero and the colour will approach the correct visual effect as each metallic element becomes vaporised. Warm-up CMH PAR2 2W 3K Warm-up CMH PAR3 2W 3K 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 1 15 2 25 P V I Lm 3 35 5 5 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 1 15 2 25 P V I Lm 3 35 5 5 CMH PAR2 35W 3K CMH PAR3 35W 3K 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 1 15 2 25 P V I Lm 3 35 5 5 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 1 15 2 25 P V I Lm 3 35 5 5 CMH PAR3 7W 3K CMH PAR2 35W 2K 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 1 15 2 25 P V I Lm 3 35 5 5 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 15 25 P V I Lm 35 5 5 CMH PAR3 35W 2K CMH PAR3 7W 2K 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 15 25 P V I Lm 35 5 5 1% 13% 12% 11% 1% 9% 8% 7% 6% 5% % 3% 2% 1% % 5 15 25 P V I Lm 35 5 5 11

Maximum temperature The table below shows the maximum temperatures on PAR lamps at different positions. The values are valid for all wattages for both PAR2 and PAR3. and PAR3 lamps. Location Base Lens seal Bulb Maximum temperature 2 C 16 C 3 C Supply voltage sensitivity The line supply voltage applied to the control gear should be as close to rated nominal as possible. s will start and operate at 1% below rated supply voltage but this should not be considered as a normal operating condition. In order to maximise lamp survival, lumen maintenance and colour uniformity, supply voltage and rated ballast voltage should be within ±3%. Supply variations of ±5% are permissible for short periods only. Where supply voltage variation is likely to occur the use of electronic control gear should be considered as this type of equipment is normally designed to function correctly for a voltage range of 22-2V. Dimming In certain cases, dimming may be acceptable, subject to further testing. Contact your GE representative for more information. Large changes in lamp power alter the thermal characteristics of the lamp resulting in lamp colour shift and possible reduction in lamp survival. Flicker With conventional ballasts there will be a line frequency (5 Hz) flicker from ConstantColor CMH lamps as with all other discharge lamps. Normally this is not of concern, but, where visual comfort and performance is critical, the use of electronic control gear should be considered. Suitable electronic ballasts for ConstantColor CMH lamps provide square wave operation in the 7- Hz range and eliminate perceptible flicker. End-of-life conditions The principal end-of-life failure mechanism for CMH lamps is arc tube leakage into the outer jacket. High operating temperature inside the arc tube causes metal halide dose material to gradually corrode through the ceramic arc tube wall, eventually resulting at normal end-of-life in leakage of the filling gas and dose. Arc tube leakage into the outer jacket can be observed by a sudden and significant lumen drop and a perceptible colour change (usually towards green). The above situation is often accompanied by the so-called rectification phenomena. This occurs where a discharge is established between two mount-frame parts of different material and/or mass, causing asymmetry in the electrical characteristic of the resulting discharge current. Rectification can lead to overheating of the ballast, therefore conventional magnetic ballasts must conform to requirements of the IEC61167 lamp standard by incorporating protection to maintain safety and prevent damage. s designated as CMH7/PAR3 do not require thermally protected ballasts. See Fusing Recommendations. End-of-life cycling A condition can exist at end-of-life whereby lamp voltage rises to a value exceeding the voltage supplied by the control gear. In such a case the lamp extinguished and on cooling restarts when the required ignition voltage falls to the actual pulse voltage provided by the ignitor. During subsequent warm-up the lamp voltage will again increase, causing extinction. This condition is known as end-of-life cycling. Normally cycling is an indication that lamp end-of-life has been reached, but it can also occur when lamps are operated above their recommended temperature. voltage at 1 hours life should not increase by more than 5V when operating in the luminaire, when compared to the same lamp operating in free-air. A good luminaire design will limit lamp voltage rise to 3V. It is good practice to replace lamps that have reached end-of-life as soon as possible after failure, to minimise electrical and thermal stress on ignitor components. The use of a timed or cut-out ignitor is not a specific requirement for ConstantColor CMH lamps, but is worth considering as a good optional safety feature which also prolongs the life of ignitor internal components, lamp holder contact surfaces, and fixture wiring. The operating period of a timed/cut-out ignitor must be adequate to allow lamps to cool and restart. A period of 1 to 15 minutes continuous or intermittent operation is recommended before the ignitor automatically switches off. Timed/cut-out ignitors, specifically offered for High-Pressure Sodium lamps, where the period of operation is less than 5 minutes, are not suitable for ConstantColor CMH lamps. See Fusing Recommendations. 12

UV and damage to sensitive materials The wall of the bulb, which is produced with specially developed UV Control material, absorbs potentially harmful high energy UV radiation emitted by the ceramic arc tube. The use of UV control material allows the lamp to significantly reduce the risk of discolouration or fading of products. When illuminating light-sensitive materials or at high light levels, additional UV filtration is recommended. Luminaires should not be used if the front glass is broken or missing. Although PET determines limits of human exposure to lamp UV, the risk of fading of merchandise due to UV can be quantified by a Damage Factor and a Risk of Fading. The risk of fading is simply the numerical product of the illuminance, exposure time and damage factor due to the light source. Finally the selection of luminaire materials should take into consideration the UV emission. Current UV reduction types on the market are optimised for UV safety of human eye and skin exposure. However, luminaire materials may have different wavelength dependent response functions. Designers must take account of emission in each of the UV-A, UV-B and UV-C spectral ranges as well as material temperatures when designing luminaires. Typical values for UV-A, UV-B and UV-C range radiation can be found in the table below. type UV-PET Performance 2W PAR2 2W PAR3 35W PAR2 35W PAR3 35W K PAR2 35W k PAR3 7W PAR3 7W K PAR3 UV-C 1 2-28nm.1.1.1.1...1.1 UV-B 1 28-315nm.29.39.5.12.1..8. UV-A 1 315-nm 7.116 7.968.5537 8.83 9.2583 6.5 5.3727 5.199 UVC/UVB.555.333.113.682...77 8.222 UVB/UVA..5.1.1.2.1.2. E eff 2 mw / (m 2 *klx).13.12..9.8.5.5.71 PET (h)±1% 63 712 1982 936 13 17 1638 2358 Risk Group IESNA RP-27.3-96 Exempt Exempt Exempt Exempt Exempt Exempt Exempt Exempt 1 μw / (cm 2 ) / 5 Lux 2 mw / (m 2 *klx) Information on luminaire design Ballasts ConstantColor CMH lamps operate from the same type of ballast as conventional quartz technology metal halide lamps of the same nominal power. IEC 61167 MH lamp standard and IEC 6235 HID lamp safety standard specify use of ballast thermal protection or equivalent protection device in the circuit, if required by the manufacturer. This safety device will protect the ballast and fixture from overheating damage at lamp end-of-life should rectification occur due to electrode imbalance or arc tube failure. The IEC61167 requirement applies to both ceramic and quartz arc tube metal halide lamps of the UV-A, UV-B, and UV-C spectral ranges as well as material temperatures when designing luminaires. ConstantColor CMH lamps are compatible with a list of approved ballasts; contact your GE representative for more information. Stray magnetic field of conventional ballasts At the design stage for fixtures incorporating the control gear, careful consideration should be given to the physical layout of the lamp and ballast. The relative positions and distance between lamp and ballast can adversely affect lamp performance and drastically reduce lamp survival. Conventional magnetic ballasts can produce a stray magnetic field and if the lamp is placed within this field, bowing of the arc in the discharge tube can occur. Since ceramic is a very rigid material, severe arc bowing can cause high thermal stress leading to cracking or rupture of the arc tube, resulting in failure of the lamp early in life. Such bowing of the arc can also affect the quartz arc tube in conventional metal halide lamps, but cracking or rupture failure is less likely since quartz softens at the resulting higher wall temperature causing the arc tube to become swollen. Excessive swelling of a quartz arc tube can however also result in cracking or rupture failure. In fixtures where the ballast is necessarily placed close to the lamp, use of magnetic shielding is essential. Another solution is to use an electronic ballast, which eliminates the need for an ignitor, simplifies wiring, reduces the risk of stray magnetic field, and eliminates light output flicker. Containment requirement ConstantColor CMH PAR lamps may be used in open fixtures. 13

Control gear and accessories Electronic ballasts A range of GE electronic ballasts have been introduced to complement the ConstantColor Ceramic Metal Halide lamps. Power controlled electronic ballasts suitable for operation of Ceramic Metal Halide lamps are available from various gear manufacturers. Advantages are: Good regulation against supply voltage variation Improved lamp colour consistency Elimination of lamp flicker Reduced weight of control gear Reduced electrical power losses Ballast noise reduced/eliminated Single piece compact unit Reduced wiring complexity in the luminaire For selecting proper ballast for CMH lamps please see separate CMH ballasts data sheet. Superimposed ignitors In many installations Ceramic Metal Halide lamps are operated from a conventional magnetic ballast in conjunction with a superimposed ignitor. These ignitors generate starting pulses independently from the ballast and should be placed close to the lamp, preferably within the luminaire. Wiring between ignitor and lamp should have a maximum capacitance to earth of 1pF (length equivalent to less than 1 Metre) - contact ignitor manufacturer for details of specific ignitor types. A typical circuit diagram is shown. Typical superimposed ignitor circuit Suitable ignitors Suitable high-energy (superimposed) ignitors are listed below recommended by gear manufacturers. Check with your supplier for their current range of ignitors. re-starting under warm lamp conditions can take up to 15 minutes. Suitable ignitors with a warm restart of less than 15 minutes include the following, however the list may not be fully inclusive. Maker Products APF SP23 BAG Turgi NI 15 SE-CM NI LE K NI LE K-TM2 ERC ASP 1.8 ASP 1.8 T22 ASP 3. Helvar L-15 LSI-15T2 Optima ZG.5 D Parmar PAE255 Philips SU2S SU2T2S Thorn G5359 G5355 Tridonic ZRM 1.8-ES/B ZRM 2.5-ES/D ZRM.5-ES/B Vossloh-Schwabe Z 25 Z 25 K D2 1

Impulser ignitors Impulser type ignitors use the ballast winding as a pulse transformer and can only be used with a matched ballast. Always check with the ballast and ignitor supplier that components are compatible. Longer cable lengths between ballast & ignitor and the lamp are possible due to the lower pulse frequency generated, giving greater flexibility for remote control gear applications. Ignitor pulse characteristics at the lamp must however comply with specified minimum values for ConstantColor CMH lamps under all conditions. Typical impulser ignitor circuit Other ignitor related considerations Timed or cut-out ignitors The use of a timed or cut-out ignitor is not a specific requirement for ConstantColor CMH lamps but it is a good optional safety feature worth considering to protect the ignitor from overheating and to prolong its life. If used, the timed period must be adequate to allow lamps to cool and restart as described in the previous section. A period of 1-15 minutes continuous or intermittent operation is recommended before the ignitor automatically switches off. Timed ignitors specifically offered for High-Pressure Sodium lamps where the period of operation is only about 5 minutes are not suitable for ConstantColor CMH lamps. Instant hot re-strike is only possible using a suitable very high voltage ignitor and double-ended lamp. GE Lighting should be consulted when considering use of an instant hot re-striking system. Hot re-strike All ratings re-strike within 15 minutes following a short interruption in the supply. Hot re-strike may be achieved using a suitable ignitor. Actual re-strike time is determined by the ignitor type, pulse voltage and cooling rate of the lamp. Warm re-starting Because of the ceramic materials and the vacuum jacket ConstantColor CMH lamps loose their heat slowly. It is possible with low energy (impulser) ignitors to reach the required breakdown voltage, but not sustain a thermionic discharge. Under these conditions the lamp can remain warm and be prevented from cooling to a temperature at which the arc can be reestablished. To avoid this, turn off the power supply for approximately fifteen minutes or change to a suitable ignitor from the list given in the superimposed ignitor section. Fusing recommendations For a very short period immediately after switch-on, all discharge lamps can act as a partial rectifier and the ballast may allow higher than the normal current to flow. In order to prevent nuisance fuse failure the fuse ratings must take account of this. Number of s 1 2 3 5 6 35W Fuse Rating (A) 6 7W Fuse Rating (A) 6 1 1 See relevant information on national installation requirements for High Intensity Discharge lighting circuits. Single fusing is recommended which gives added protection for the end-of-life condition when partial rectification can also occur. HBC or MCB (type 3 or ) fuse ratings for single and multiple lamp installations 15

Safety warnings The use of these products requires awareness of the following safety issues: Warning: Risk of electric shock - isolate from power before changing lamp. Strong magnetic fields may impair lamp performance. Do not use where directly exposed to water or outdoors without an enclosed fixture. Keep combustible materials away from lamp. A damaged lamp emits UV radiation which may cause eye/skin injury. Unexpected lamp rupture may cause injury, fire, or property damage. Use only properly rated ballast and supply voltage. Do not use beyond rated life Caution: Risk of burn when handling hot lamp. Allow lamp to cool before handling. Do not turn on lamp until fully installed. may shatter and cause injury if broken. Do not use lamp if outer glass is scratched or broken. Arc tube fill gas contain Kr-85. Dispose of lamps in accord with local regulations. Always follow the supplied lamp operation and handling instructions. www.gelighting.com/eu and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. ConstantColor CMH PAR Data Sheet February 211