Master Slave Converter [ VAC & VAC]

Similar documents
PowerAir Compressor Installation

Spring Bearing Rocker Replacement Installation [Kit # ] for Elevance Continental-Style Delivery Unit

Flex Work Station Delivery Units Installation Guide

Side Delivery Unit Installation

ClassicSeries Compressor Installation

Rock Compressors. Service and Parts Manual. Twin R22 Triple R42 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers: R42 Shown

PowerVac. Service and Parts Manual P3 P5 P7. Single Vac Units. Twin Vac Units P6 P10 P14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY.

Cylinder Rod End Replacement Kit [ ]

PowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Product Name Chair Conversion Kit (to Console Delivery Unit) Installation [Kit # xx]

PowerMax Surgical Suction Producers

Knee Crutches / Cladding [9A410 / 9A411 / 9A412 / 9A413]

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Midmark Cabinet / Wall Light Installation

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36

Technical Service Bulletin

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

Master Series Gas XPress Grill

Installation, Operation and Maintenance Manual

Emotron DCM Control Unit

ECCII to ECCIII Upgrade Kit

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Mizer Single Pump and Starter Box

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

AirStar Tandem Installation Kit Part Number 85694

255 LED Light Dual Conversion Installation [9A584001]

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

TE2010-GE Instructions manual

B to A Solenoid Adapter Kit Installation & Troubleshooting Guide

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) ES142 Spring Return Electronic Actuators

S1820 CONVEYOR OVEN REPLACEMENT PARTS MANUAL (with WIRING DIAGRAMS)

3 Phase Smart Controller

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

TT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

MODEL L-1C PARTS MANUAL. Rev 1.00A C M A D I S H M A C H I N E S K N O T T A V E N U E GARDEN GROVE, CALIFORNIA

Installation Instructions

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

MODEL GL-X PARTS MANUAL

PowerVac G. Service and Parts Manual G3 G5 G7 G6 G10 G14. Model Numbers: Single Vac Units. Twin Vac Units FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Instruction Bulletin. Jockey Pump Controller

EPB Series Battery Powered Punchdown Tool. User Manual. 134 Marbledale Road Tuckahoe NY Tel: Fax:

Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

Installation Instructions: Read these instructions in its entirety before performing any installation work.

M9216 Series Electric Spring Return Actuators

P445 Series Electronic Lube Oil Control

Junction Boxes. Common Components Air / Water Control Valves. Contoured Junction Box. Small Junction Box. Elevance Junction Box

MODEL L-1X & L-1X16 PARTS MANUAL

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

INSTALLATION INSTRUCTIONS. Timer Features

Troubleshooting Guide

MODEL CMA-180UC PARTS MANUAL Rev 1.19A

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

H20.5 Series Electric Fryers

Application Engineering

BITZER Liquid Injection Guidelines for CSH Compressors

MODEL CMA-180UC PARTS MANUAL Rev 1.19

System 350 P352AB Electronic Pressure Control Series

Installation Instructions

Power Procedures Table

POWER COLOR FAST STOP OFF SLOW. AfterDark IMPORTANT INFORMATION

Minimum 27 in-lb torque

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

KEY PARTS PS540-SERIES GAS OVEN KEY PARTS ITEM PART NO. ENGLISH DESCRIPTION QUANTITY

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Operating Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger

HLS Watt Halogen Illuminator Service Manual

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

Parts Information. Commercial Microwave Oven

Residential microinverter system

SERVICE MANUAL (INTERNATIONAL)

30-SS1203A 12,000 LB CAPACITY SCISSOR ALIGNMENT LIFT INSTALLATION AND SERVICE MANUAL P/N:

Hydrovar and Packaged Hydrovar

Minimum 27 in-lb Torque

OutdoorXUPS-600AHV-8364

Transcription:

Master Slave Converter [002-1590-00-115 VAC & 002-1590-01 230 VAC] Contents: Installation...1 Wire Diagram...4 Exploded View...6 Intended Use: To provide simultaneous operation of up to five Midmark compressors connected to a common operatory air supply line. Note: Low voltage control is required on the designated master compressor only. Language of origin: English Step 1: Install power supply. A) Select which compressor will be the master. Midmark recommends the compressor with the least amount of run hours should be the master. B) Verify voltage on master compressor matches voltage on master slave converter box. Refer to wire diagrams in this manual. C) Shut off main power supply to all compressors. D) Mount master slave converter box if desired. E) Remove compressor electrical box cover. F) Drill 13/16 hole on left side of compressor electrical box. G) Install conduit through 13/16 hole and connect to one of the on/off switches in the compressor electrical box as shown. H) Connect ground wire to ground screw in compressor electrical box. I) Install compressor electrical box cover. Note: If mounting master box is desired, mount box close enough to the compressor electrical boxes for cables and power supply conduit will reach connections. Mounting screws are not included. The compressor you connect the conduit to will be considered the master compressor. 13/16 Drilled Hole Conduit On / Off Switch Ground English-1 003-2525-00 Rev. A (7/12)

Low Voltage Wires on Back of Compressor Control Box Step 2: Install slave cables to all slave compressors. A) Remove wire nut from low voltage wires on back of compressor electrical box. B) Connect one master slave converter box cable to low voltage wires, Red to Red and Black to Blue. C) Repeat A) and B) for each compressor your connecting to the master slave converter box. D) Install a wire nut on each master slave converter box cable wire not being used. E) Turn main power supply on for each compressor. Note: Master compressor will be the only one that stays connected to remote switch (Master Control Panel) in operatory. Slave Cable from Master Slave Converter Box English-2

Step 3: Adjust slave compressor pressure switches. A) Adjust pressure switches in the slave compressors, not the master compressor, to ensure the switch stays closed through cycle. Midmark Brands... B) Remove pressure switch cover. C) Turn adjustment nut clockwise until switch stays closed through cycle. D) Install pressure switch cover. E) Restore power to compressors. Note: The master compressor is the one you connected the master slave converter conduit power supply to in step 1. Midmark PowerAir Pressure Switch Adjustment Nut Shown Note Older style Midmark compressors may only have two wires in pressure switch. English-3

Master Slave Converter Box Wire Diagram 115 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH Transformer Ground OR GN English-4

Master Slave Converter Box Wire Diagram 230 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH OR Transformer Ground GN English-5

1 040-0010-145 015-3122-00 5 4 2 62964303 3 015-1986-00 Serial Numbers / Dates: all 4 041-0010-04 Service Parts Item Description Qty. 1 Screw, Panhead, (.190-24 x.500) 4 2 Dim, Rail 1 3 Transformer, 240V / 115V 50/60/HZ 1 4 Nut Keps with tooth lock washer, (.190-21) 4 5 Contactor 1 English-6